Tender Value
Refer Docs
Closing Date
10 Nov 2021, 3:00 pmClosed
EE(SP)
O/o Executive Engineer (SP) DTTDC Ltd Lajpat Nagar Site Office Near Cambridge School Ring Road Sriniwaspuri New Delhi 110065
Designing, Supplying, Installation, Testing, Commissioning of Modular Clean rooms including renovation of Micro lab (Room Number 7), Center Instrumentation Lab (Room Number 8) and Plant Tissue Culture lab (Room number 407) at DPSARU
2021_DTTDC_210561_1
05/DTTDC/EE(SP)/2021-22
Open Tender
Composite Works
Item Rate
120 days
DTTDC Ltd. Sriniwaspuri Lajpat Nagar Site Office
Please refer Tender documents.
11 documents required · 11 mandatory
₹0
Exempted
20 Nov 2021
2 Nov 2021
10 Nov 2021
2 Nov 2021
10 Nov 2021
2 Nov 2021
Amount
Preparation and repairing of area/ surfaces for designing of clean room/various labs by • Dismantling and demolishing and accessories and others unserviceable by mechanical transport including loading, unloading and proper stacking within 300 mtr. lead as per direction of Engineer incharge. • Demolishing R.C.C. Slab/ Granite counter with brick masonry support by manual including stacking of steel bars and disposal of unserviceable material. • Demolishing brick work brick masonry wall including stacking of serviceable material and disposal of unserviceable material. Shall be done with the consultation of Structure Engineer • Dismantling of ceramic floor tiles and as well as wall tiles as per site. • Dismantling of gypsum board false ceiling or partition walls including stacking of serviceable materials.
• Dismantling/ removal of aluminium partitions, doors, windows, fixed glazing including disposal of unserviceable material and stacking of serviceable material as directed by Engineer-in-charge. • Dismantling/ taking out existing water supply line and drainage system or C.I. or G.I pipes including excavation and refilling trenches. • Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge. • Cutting of Hole for AHU duct as per HVAC drawing as well as same to be Repair with brick masonry work. • Repairs to cement plaster of required thickness in patches of area after removal of wall tiles or damp proof area or any other space if required, including cutting the patch in proper shape, and preparing and plastering the surface of the walls complete, as per direction of Engineer-in-Charge. • Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: • Construction of RCC foundation/ cement concrete work etc. for AHU and other outsider equipment cooling systems as per approved drawing and design NOTE : The Surface wall area/floor area/Ceiling area shall be considered for the payment purpose. (The contractor shall visit of site and study the scope in detail work before submitting tender)
AHU SHED - Making, providing and fixing steel structural shed of minimum size [2700mm(L)X1500mm(W)X1500mm(H)] in built up tubular (4"/3"/2"/ round, square or rectangular hollow tubes etc.) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. and painting complete. Fixing in precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-incharge) 0.50 mm (+ 0.05 %) on top roof, side cover with angle iron support, welded mesh and related other allied work desired by Engineer -in- charge
Wall Puff Panel (PPGI )- Design, Supply, Installation,Testing ,Commissioning of modular partion sandwiched ceiling panels with Pre Coated Sheet on both sides of 0.5 mm thick POLYEURATHINE FOAM as an infill material of density not less than that of 40±2kg/m3 with/without tongue & ggroove arrangement and all ceiling panel joints are filled with good grade of silicon sealant.
Supply & Installation of modular partion sandwiched ceiling panels with Pre Coated Sheet on both sides of 0.5 mm thick POLYEURATHINE FOAM as an infill material of density not less than that of 40±2kg/m3 with/without tongue & ggroove arrangement and all ceiling panel joints are filled with good grade of silicon sealant.
Thickness: 80 mm- WALL
Thickness: 60 mm- WALL
Built In Riser PUF Panel (PPGI ) -Supply,Installation,Testing & commissioning of bulit in riser PCGI puf panel of 80 mm thick for return air damper & Al. powder coated Grill.
Thickness: 80 mm
Ceiling Puff Panel (PPGI ) - Design, Supply, Installation,Testing ,Commissioning sandwiched ceiling panels with Pre Coated Sheet on both sides of 0.5 mm thick POLYEURATHINE FOAM as an infill material of density not less than that of 40±2kg/m3 with/without tongue & ggroove arrangement and all ceiling panel joints are filled with good grade of silicon sealant.
Supply & Installation of modular partion sandwiched ceiling panels with Pre Coated Sheet on both sides of 0.5 mm thick POLYEURATHINE FOAM as an infill material of density not less than that of 40±2kg/m3 with/without tongue & ggroove arrangement and all ceiling panel joints are filled with good grade of silicon sealant.
Thickness: 60 mm
Thickness: 50 mm
Door - Supply & Installation of Aluminium Powder coated Door with 50mm thickness suitable to fix in PUF wall mounted made with GLASS/ACP/WOODEN PANELS and PCGI Powder coated door frames totally flush with all acessories such as Door Closer, Handles, View Glass Etc.
Single door (D1)750x2100mm
Single door (D1)900x2100mm
Single door (D1)1500x2100mm
Accessories of Aluminum powder coated such as door closer handles view glass
Powder Coated Aluminium Coving -Supply & installation of PVC Coving of R60 is being used to fill the gap between wall panel to false ceiling and also between wall panel to wall panel at corners.No coving considered for Floor to wall corners.
Horizontal Coving for wall to ceiling
Vertical Coving
Horizontal Coving for wall to floor
GI METAL CEILING TILES -Supply & installation of GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm, Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
Epoxy Flooring Coating
Supply and Application of EPOXY Flooring 2+3mm thickness, complete with all necessary hardware,accessories,fittings and fixture,Epoxy Resin & Hardneer (Berger/Fosroc/Aditya Birla or equivalent) as per the approved by the Engineer Incharge. Supply and apply of one coat of ware based Epoxy primer Florprime WB or EP followed by 2 mm thick self levelling Epoxy self levelled screed florscreed SL+ topcoat 1 mm thick Epoxy self levelling florgard SL and surface prepration.
CROSS OVER BENCH -Supply,installation,testing & commissioning of cross over bench made SS-304, both side shoose storing rack and blocking cross contemination to unclassified to classified area .
Size:- 1500X350X610
DYNAMIC PASS BOX -Supply,installation,testing & commissioning of SS-304 Dynamic Pass box having Hepa filter 0.3 micron, pre filter 10 micron, both double door having electromagnectic interlocking with Touch Control Human Machine Interface , One time one side only open to controll cross contamination with having UV light as well fluorescent light .
Size:- 610X610X600-DIGITAL DISPLAY
Garment Cabinet - Supply,installation,testing & commissioning of Ms Powder Coated static garment cabinate having double door having UV light as well fluorescent light .
Size:-900X750X1550 mm
Wall Bench as per SEFA 8M and SEFA 10 Norms OEM Should have SEFA member from last 5 years
Dimension L (mm) X B(mm) X H (mm) = (1500+3000+3000+3600) X 750 X 900, Material of construction - SS 304, along with sink, Electrical raceway and under benches on castors. As per Approved drawing by the Engineer -in- charge.
L(mm) X B(mm) X H (mm) = (3300+3600+3000+2100+2100+4200+3000) X 900 X 900, , along with Electrical raceway, Underbenchs on plinth and sink as per approved drawing by the Site Engineer
CO2 Incubator - • Temperature range Ambient +5°C to 45°C . • Temperature Uniformity ±0.3 °C at 37 °C. • Interior Volume: Minimum 110 liters and must not be higher than 200 liters • CO2 control range: 0-20%. Control: Better than ±0.1%, measures with T/C sensor • Readability and Satiability at least 0.1%. • Stainless steel shelves and supports should be readily removable without tools for easy cleaning, autoclaving or adjustment. • Heat sterilization cycle of at least 140:C for 12 hours to safely kill all organisms within the chamber. • Built in system audible alarm should be activated if the outer door is opened during the Heat Sterilization cycle and the temperature is 60°C or greater to ensure safety in the lab. • The Microprocessor Control System should give clear cut written message for the errors, should guide through the cycle with start-up and cycle status messages during decontamination phase. • Post decontamination process, the system should return to normal operating status without the need for manual cleaning. • HEPA filtered chamber airflow. • 100% filtration of chamber air every 60 seconds to clean room particulate and air borne contamination to best air quality standards thereby providing constant protection against contaminations. • Built-in system with adjustable timeframe to notify the user when it’s time to replace the filter and should be easily removable without tools. • Uniform distribution of direct heat at every part of the inner chamber. • There should be microbiological filters on all gas inlets and outlets and sample ports to reduce the potential contamination sources. • Programmable tracking alarms for temperature and CO2. Alarms should be custom configurable. • All probes and sensors located inside the chamber should be easily located. • System should be compatible to 230V/50-60 Hz. • Machine must be EN ISO/IEC 17050-1:2010 and CE certified
Biosafety Cabinet - • Class II Bio-safety Cabinet Type A2 design. • Should include a germicidal UV lamp, set of arm rest, an electrical outlet and a support stand provided with levelling bases. • Size 4 feet width and the front window must have 8/ 10” sash opening with working surface of stainless steel 304. • Motor should be DC or ECM & must automatically adjust the airflow speed (balancing inflow and down flow) without the use of a damper to ensure continuous safe working conditions. • The microprocessor must display the inflow and down flow air velocities in real-time on an LED/LCD display with touch screen. • HepaFilter should be 99.995% MPPS(Most Penetrating Particle Size) • UV light must be programmable to allow for specific exposure times from 0 to 24 hours. Lightening power should >1100 lux(100fc);cabinet noise level must be less than 65 dB(A) • Cabinet should be EN 12469/ NSF (National Sanitation Foundation) certified and certificate of the quoted model should be attached. • Power Consumption in Normal mode :200W ±10% • The supplier should have at least 5 installations Base of Bio-safety in India.
• Class II Bio-safety Cabinet Type A2 design. • Should include a germicidal UV lamp, set of arm rest, an electrical outlet and a support stand provided with levelling bases. • Size 4 feet width and the front window must have 8/ 10” sash opening with working surface of stainless steel 304. • Motor should be DC or ECM & must automatically adjust the airflow speed (balancing inflow and down flow) without the use of a damper to ensure continuous safe working conditions. • The microprocessor must display the inflow and down flow air velocities in real-time on an LED/LCD display with touch sceen. • HepaFilter should be 99.995% MPPS(Most Penetrating Particle Size) • UV light must be programmable to allow for specific exposure times from 0 to 24 hours. Lightening power should >1100 lux(100fc);cabinet noise level must be less than 65 dB(A) • Cabinet should be EN 12469/ NSF (National Sanitation Foundation) certified and certificate of the quoted model should be attached. • Power Consumption in Normal mode :200W ±10% • The supplier should have at least 5 installations Base of Bio-safety in India.
Glass Partition Work
Supply Installation and commissioning of Glass work partition 10 mm toughed glass with SS 304 or better frame,fittings,fixtures with all accessories, hardware from dorma,haffle, hettich make or as per the approval by Engineer Incharge.
Glass Door Supply & Installation of 10 mm toughed glass with SS 304 Door Fittings, Closer, Handles, View Glass Etc. or as per the approval by Engineer Incharge
Single door (D1)1000x2100mm
Vinyl Flooring Supply,installation of vinyle flooring 2mm, self leveling and 2 mm is seamless finishing having property antibacterial, antifungle and anticorossion of the approved make by the Engineer Incharge.
Thickness:- 2 mm
GI METAL CEILING TILES -Supply & installation of GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm, Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
Laboratory Cabinet -Internal Dimensions (mm) -900(L)X550(D)X2090(H), As per SEFA standards
Overhead Cabinets- Internal Dimentions (mm) - 600(L)X500(D)X600(H), As per SEFA standards
Supply & Installation of Magnehelic guage with inbuilt Digital Feedback Output port and Analog Output Dial , Unit Fixed Inside SS-304 Box.
Clean Room Validation which includes velocity test,partical count test, DOP test and tests as per ISO, Federal Standard 209E/IP 2010 etc.c/w all documentation of IQ,DQ,PQ etc.
Air Handling Unit - Design, Supply, Installation,Testing ,Commissioning of Single Decker type double skin (with High density Puff insulation ) Draw through/Blow thru type AHUs complete with thermal break profile consisting of mixing air plenum section, blower sections with imported PLUG type/DIDW blowers(supply blower), DX type coil, G-4 (pre filters) & F-7(Fine filters) (The velcoity across filter & coils should not exceed 500 FPM), 'Zero leak/ very low leakage' Aluminium Supply Air dampers, Return Air damper,Unit base frame with VI pads, motor suitable with variable frequency drive(VFD excluded) .Supply Air Plenum section, access doors across each section as per approved design, drive set with coupling guard, vibration isolators,internal lights, limit switches, necessary instruments. Motor shall be of IE.2 rating. All gasket shall be food grade neoprene. With Temperature and RH data can be recorded on cloud in realtime of the room,ducts and AHU. ISO, Federal Standard 209E/IP 2010
Supply, installation, testing and commissioning of Single Decker type double skin (with High density Puff insulation ) Draw through/Blow thru type AHUs complete with thermal break profile consisting of mixing air plenum section, blower sections with imported PLUG type/DIDW blowers(supply blower), DX type coil, G-4 (pre filters) & F-7(Fine filters) (The velcoity across filter & coils should not exceed 500 FPM), 'Zero leak/ very low leakage' Aluminium Supply Air dampers, Return Air damper,Unit base frame with VI pads, motor suitable with variable frequency drive(VFD excluded) .Supply Air Plenum section, access doors across each section as per approved design, drive set with coupling guard, vibration isolators,internal lights, limit switches, necessary instruments. Motor shall be of IE.2 rating. All gasket shall be food grade neoprene. With Temperature and RH data can be recorded on cloud in realtime of the room,ducts and AHU. Data for cleanroom :- Inside Temperature: 22 +/- 2°C Relative humidity: less than 60% Positive Pressure gradient: As per tender zoning plan ACPH in BSL Lab : More than12 Filtration : HEPA Filter Supply Air in BSL. HEPA Filter Exhaust Air inBSL-2. Ventilation : 30% FA system for BSL. Other areas with only FA & EA System. Exhaust Fan location for BSL: Minimum 10ft from AHU intake. Air velocity at exhaust discharge: 15-20 m/s (3000-4000 fpm) forBSL Labs
Capacity :- 4000(125 SP,6 Row) - 11.5 TR
AIR COOLED -DIRECT EXPANSION TYPE Outdoor Type-Supply, installation, testing & commissioning of condensing units with Scroll Compressor for Temperature control with Green refrigerent , Motor, Air cooled Cooled condenser ,control wiring and all accessories as required and called for, microprocessor based automatic and safety controls, all mounted on a steel frame complete as per specifications. Motor shall be suitable for 415+ 10% 50 cycles. 3 phase AC supply. Isolator and starter shall be provided in the Control Panel which shall be compatible with BMS system as per of specifications. Lifting,shifting,connection,fixing chiller including spring type vibration isolator, Dryer , Expansion Valves , Sight Glass to be included in quoted price.
Supply, installation, testing & commissioning of condensing units with Scroll Compressor for Temperature control with Green refrigerent , Motor, Air cooled Cooled condenser ,control wiring and all accessories as required and called for, microprocessor based automatic and safety controls, all mounted on a steel frame complete as per specifications. Motor shall be suitable for 415+ 10% 50 cycles. 3 phase AC supply. Isolator and starter shall be provided in the Control Panel which shall be compatible with BMS system as per of specifications. Lifting,shifting,connection,fixing chiller including spring type vibration isolator, Dryer , Expansion Valves , Sight Glass to be included in quoted price.
Capacity : 11.5 TR
AIR COOLED -DUCTABLE UNIT-Supply, installation, testing & commissioning of Air Colled Type Ductable unit s with Scroll Compressor for Temperature control with Green refrigerent , Motor, Air cooled Cooled condenser ,control wiring and all accessories as required and called for, microprocessor based automatic and safety controls, all mounted on a steel frame complete as per specifications. Motor shall be suitable for 415+ 10% 50 cycles. 3 phase AC supply. Isolator and starter shall be provided in the Control Panel which shall be compatible with BMS system as per of specifications. Lifting,shifting,connection,fixing chiller including spring type vibration isolator, Dryer , Expansion Valves , Sight Glass to be included in quoted price.
Supply, installation, testing & commissioning of Air Colled Type Ductable unit s with Scroll Compressor for Temperature control with Green refrigerent , Motor, Air cooled Cooled condenser ,control wiring and all accessories as required and called for, microprocessor based automatic and safety controls, all mounted on a steel frame complete as per specifications. Motor shall be suitable for 415+ 10% 50 cycles. 3 phase AC supply. Isolator and starter shall be provided in the Control Panel which shall be compatible with BMS system as per of specifications. Lifting,shifting,connection,fixing chiller including spring type vibration isolator, Dryer , Expansion Valves , Sight Glass to be included in quoted price.
Capacity : 3 TR
Capacity : 5.5 TR
Capacity : 8.5 TR
Ducting -Supply,lubrication,installation and testing of GI Square/rectangular/triangle ducting complete in all respect along with Gasket , food grade silicon sealant , hanging arrangement .
Supply,lubrication,installation and testing of GI Square/rectangular/triangle ducting complete in all respect along with Gasket , food grade silicon sealant , hanging arrangement .
22Gauge
24 Gauge
Insulation-Supply and application of Nitrile Rubber insulation from outer or inside. All joints of insulation should be cover with aluminium tape on A/C Duct.
Supply and application of Nitrile Rubber insulation from outer or inside. All joints of insulation should be cover with aluminium tape on A/C Duct.
Thickness:- 13 mm
Thickness:- 9 mm
Thickness:- 6 mm
Supply, installation commissioning of control dampers with proper fasteners and gasket. multi blade box type GSS construction damper for ducts
Housing ,Hepa filter, Al Grill With Damper(S.A)-Supply,installation,testing & commissioning of MS powercoated housing perforated supply air grills made out of extruded Al sheet,0.3 micronhepa filter and volume control damper.
Supply,installation,testing & commissioning of MS powercoated housing perforated supply air grills made out of extruded Al sheet,0.3 micronhepa filter and volume control damper.
Size:- 610X610X150 HEPA
Size:- 450X450X150 HEPA
Size:- 305X305X150 HEPA
Return Air Grills with Dampers -Supply,installation,testing & commissioning of powercoated perforated (65%) supply air grills made out of Powder Coated extruded aluminium sheet and volume control damper with Pre Filter of 10 Micron.
Supply,installation,testing & commissioning of powercoated perforated (65%) supply air grills made out of Powder Coated extruded aluminium sheet and volume control damper with Pre Filter of 10 Micron.
Size:- 600mm x 300 mm
Diffusers-Supply,installation,testing & commissioning of powercoated Aluminium Diffusers with/without Dampers made out of Powder Coated extruded aluminium sheet and volume control damper .
Supply,installation,testing & commissioning of powercoated Aluminium Diffusers with/without Dampers made out of Powder Coated extruded aluminium sheet and volume control damper .
Size:- 600mm x 600 mm
Size:- 450mm x 450 mm
Size:- 300mm x 300 mm
Copper Piping-Supply and Installation of Copper piping with Nitrile Sleeves insulation , Proper Fixing Arrangement .
Supply and Installation of Copper piping with Nitrile Sleeves insulation , Proper Fixing Arrangement .
Dia 9/8inch
Dia 7/8 inch
Ms Supporting Fixtures for Ductings with Proper Threaded rod , Anchor Fasteners and Wooden base etc
Electrical Panel ( HVAC ONLY)-Supply,installation,testing & commissioning of Electrical Control Panel for Ductable Units that includes panel along with thermostat controlling module which can be integrated with Controller feedback signals .3phase and Single Phase electrical points will be direclty connected with buiding main Power Panel.
Supply,installation,testing & commissioning of Electrical Control Panel for Ductable Units that includes panel along with thermostat controlling module which can be integrated with Controller feedback signals .3phase and Single Phase electrical points will be direclty connected with buiding main Power Panel.
PANEL 01
PANEL02
PANEL03
Supply,installation,testing & commissioning of Electrical Control Panel for Ductable Units that includes panel along with thermostat controlling module which can be integrated with Controller feedback signals .3phase and Single Phase electrical points will be direclty connected with buiding main Power Panel.
16sq.mmx4Core (Power Cabling )
10sq.mmx4Core (Power Cabling )
6sq.mmx3Core (Power Cabling )
4sq.mmx4Core (Power Cabling )
2.5sq.mmx3 Core (Structure Cabling )
1.5sq.mmx2 Core (Structure Cabling )
1 sq.mmx6 Core (communication Cabling)
Supply & installation of Perforated Galvanized Covered cable tray or Race way for Laying Power cables/control cables or Cooper pipes Respectively .
Size :200mm x 25mm x 150mm
LIGHT FITTINGS -Clean room compatible Ceiling Mounted, Bottom openable type light fixtures , with Wiring and Swtich.
Clean room compatible Ceiling Mounted, Bottom openable type light fixtures , with Wiring and Swtich.
610 mm x 610 mm , 45 watt
300 mm x 300 mm , 18 watt
Clean Room Compatible Elec. Fixtures
Supply & installation of Industrial Grade Electrical switch & socket.(1 Ph- 2 points )
Supply & installation of Industrial Grade Electrical switch & socket ( 3 Ph - 1 Point )
FIRE ALARM SYSTEM-Design, supply ,installation testing and commissioning of the following items in FIRE ALARM SYSTEMS. As per technical specifications as well as drawing to cover each area of Biosafety lab. Fire smoke detectors, Fire alarm panel, Battery, Audible visual devices sounder(hooter),Heat sensor, Manual Call point, FRSL Amoured cable (Make Gloster), 25 mm PVC conduit including all accessories complete as required, pipe with all necessary Fittings (Jindal), Fire Extinguisher including all accessories required.
Design, supply ,installation testing and commissioning of the following items in FIRE ALARM SYSTEMS. As per technical specifications as well as drawing to cover each area of Biosafety lab. Fire smoke detectors, Fire alarm panel, Battery, Audible visual devices sounder(hooter),Heat sensor, Manual Call point, FRSL Amoured cable (Make Gloster), 25 mm PVC conduit including all accessories complete as required, pipe with all necessary Fittings (Jindal), Fire Extinguisher including all accessories required.
ACCESS CONTROL SYSTEM-Design, Supply, Installation, Testing, Commissioning & Handing over the Access Control System as follows: Supply, Installation , Testing and Commissioning of Micro processor based access 1 Door controller engineered with 32 bit CPU having capacity of 1 door to integrate with 4 Readers at Multiple locations, Expandable, Net workable. TCP/IP protocol compatible distributed Intelligence and inbuilt flash memory, having data base upto 40000 cards and support transaction buffer of 10000 transaction, 2 supervised inputs and 1 Nos of relay outputs for easy and reliable interface with the 3rd party systems. Complete with Digital Power supply etc as required. Can read both biometric and card.
Design, Supply, Installation, Testing, Commissioning & Handing over the Access Control System as follows: Supply, Installation , Testing and Commissioning of Micro processor based access 1 Door controller engineered with 32 bit CPU having capacity of 1 door to integrate with 4 Readers at Multiple locations, Expandable, Net workable. TCP/IP protocol compatible distributed Intelligence and inbuilt flash memory, having data base upto 40000 cards and support transaction buffer of 10000 transaction, 2 supervised inputs and 1 Nos of relay outputs for easy and reliable interface with the 3rd party systems. Complete with Digital Power supply etc as required. Can read both biometric and card.
CCTV System-Supply Installation, Testing & Commissioning of Network Video Recorder Supply Installation Testing & Commissioning of 42" LED Monitor, Full HD, , HDMI Port, Supply Installation, Testing & Commissioning of wall mounted 42U rack (for Control Room) Supply Installation, Testing & Commissioning of FRLS PVC conduit 25 mm Supply Installation, Testing & Commissioning of 4 pair Cat-6 Cable Supply Installation, Testing & Commissioning of 24 port loaded jack panel for CCTV cable termination in rack Supply Installation, Testing & Commissioning of 1.5mtr RJ-45 CAT-6 Patch cord for jack panel to switch connectivity 1. CAMERA DOME 2MP IP CAMERA WITH AUDIO - 6.00 Nos 2. IP CAMERA BULLET 2MPIP CAMERA WITH AUDIO -2.00 Nos 3. POE SWITCH 4CH NETGEAR ALL PORT GEGY AND 2 UPLINK ( or Equivalent make)- 4.HARD DISC 1 TB SURVEILLANCE 5.CONNECTER 6 NVR 4 CH WITH AUDIO 7.CCTV Camera Installation
Instruction for bidder:- 1. The Manufacture certificate/Test certificate/Guarantee/Warranty certificate of the material/equipments etc. supplied at site shall be submitted by the bidders as per approved make and as per direction by the Engineer-in-charge.
2. The quantities given are tentative may be more or less the payment shall be made as per actual measurement of work done satisfactorily.
3. The quoted rates by bidders shall be inclusive with all taxes, liabilities, GST Taxes, Service Tax, Designing, Supplying, Transportation Installation labour charges, Material Testing/Other Testing, Commissioning charges any other charges involved to the carry out and complete the entire work. Nothing extra shall be paid on this account.
USD ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .