Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹12.0 L+₹1.5 L (14.8%)Rejected-Finance | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | L3₹12.2 L+₹1.7 L (16.6%)Rejected-Finance | L3 | Rejected-Finance Other than lowest quoted tenderer | |
| 4 | L4₹13.5 L+₹3.1 L (29.4%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L4 | Rejected-Finance Other than lowest quoted tenderer | |
| 5 | L5₹20.2 L+₹9.7 L (93.1%)Rejected-Finance | L5 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
27 Apr 2021, 6:00 pmClosed
CWE Allahabad
HQ CWE New Cantt Allahabad
REPAIR/MAINT OF HT VCBS, RMUS AND ALLIED WORKS AT FAIZABAD UNDER GE FAIZABAD.
2021_MES_429542_1
81566/FZD/E8
Open Tender
Civil Works
Item Rate
180 days
Faizabad
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Faizabad
₹40,000
Yes
9 Jun 2021
10 Mar 2021
29 Apr 2021
11 Mar 2021
27 Apr 2021
1 Apr 2021
Amount
Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles, stays or for taking out/laying of cables and getting out in soft/loose soil complete all as specified and directed.
Returning filling in with approved excavated soil including spreading, levelling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for sand cushioning in trenches for protection of under ground cable provided in layers of sand 8cm deep before laying the cable and 15cm deep after the cable(Punned down to 18 cm) complete all as specified and directed. (Note:- Punned thickness as 18 cm shall be measured and paid)
Supply and laying Un-reinforced precast concrete cable cover 'factory made' of class HPV, Type 1 with peak of size 300 mm x 180 mm x 40 mm complete all as specified and directed by Engr-in-Charge.
M&L for complete servicing of HT Switch Gear (Vaccum Circuit Breaker) of capacity (400 Amp Ser No. 1077R & 630 Amp Ser No. 2865 VR), 11 KV (Make- Crompton Greaves Ltd) including replacing/repairing of unserviceable parts comprising the following complete all as directed by Engr-in-Charge. Note :- Spare parts will be measured and paid under separate items of this schedule as supply only. Supply only of the following spares for servicing/replacement of unsv parts of HT switch gear of capacity 400 to 630 Amps :-
Supply only following spares for servicing/replacement of unsv parts of HT switch gear of capacity 400 to 630 Amps :- Note :- items covers supply only will be suitable to equipment mentioned at Ser No. 6.00 and as specified and recommended by the OEM and directed by the Engr-in-Charge.
Complete wiring with copper wiring and suitable for equipment.
Supply only spout plain. Make : CG/L&T.
Supply only spout Thread type. Make : CG/L&T.
Supply only spout flat type. Make : CG/L&T.
Supply only bus bar spout. Make : CG/L&T.
Supply only bus bar spout contact with NUT BIG. Make : CG/L&T.
Supply only copper Jaw arm small (4 finger). Make : CG/L&T.
Supply only spout contact female. Make : CG/L&T.
Supply only trip coil all size. (Make- L&T/CG).
Supply only vaccum interrupter 34599 M3+. (Make- L&T/CG).
Supply only tripping Relay. (Make- L&T).
Supply only housing for vaccum interptor. (Make- L&T/CG).
Supply only C.T. I/G. (Make- L&T/CG).
Supply only P.T. (Make- L&T/CG).
Supply only Thermostat switch. (Make- L&T/CG).
Supply only Motor Timer. (Make- L&T/CG).
Supply only Heater. (Make- L&T/CG).
Supply only O/C E/F Relay. (Make- L&T).
Supply only spring charging motor. (Make- L&T/CG).
Supply only AUX switch. (Make- L&T/CG).
M&L for complete servicing of HT Switch Gear of capacity 1250 Amps Ser No.9923 VP (Make- Crompton Greaves Ltd) including calibration of all meters and replacing/repairing of unserviceable parts including testing comprising of following complete all as directed by Engr-in-Charge. Note :- Spare parts will be measured and paid under separate items of this schedule as supply only.
Supply only following spares for servicing/replacement of unsv parts of HT switch gear of capacity 1250 Amps :- Note :- items covers supply only will be suitable to equipment mentioned at Ser No. 8.00 and as specified and recommended by the OEM and directed by the Engr-in-Charge.
Supply only tripping Mechanism. (Make- L&T/CG).
Supply only spring charging motor. (Make- L&T/CG).
Supply only TNC switch for tripping mechanism. (Make- L&T/CG).
Supply only closing coil for making and breaking mechansm. (Make- L&T/CG).
Supply only triping coil. (Make- L&T/CG).
Supply only heater for controlling. (Make- L&T/CG).
Supply only copper Jaw arm small (4 finger).
Supply only coppr Jaw arm BIG (16 finger).
Supply only coppr Jaw arm small (16 finger).
Supply only spout contact female.
Supply only trip shaft Medium (3 slot)
Supply only trip shaft small (3 slot).
Supply only triping Relay. (Make- L&T).
Supply only housing for vaccume intreptor. (Make- L&T/CG).
Supply only Motor Timer. (Make- L&T/CG).
S&F repair /Cheking the HT 11KV , Make- ABB , Capacity (630 Amps Ser No. IVYNO40115000598 & 630 Amp Ser No. IVYNO40117000710) out door type, Ring main unit (RMU) tripping circuit and resetting trip values and the nuemerical relays and checking tripping machnism serviceing the LBS fully by engaging well experianced technicians as per manufacturer recommendation and all as directed by the Engineer-in-Charge.
Supply only of the following spares for servicing/replacement of unsv parts of RMU 630 Amp :-
Supply only complete wiring
Supply only trip shaft medium (3 slot). (Make - ABB).
Supply only master Relay. (Make - L&T).
Supply only motor timer. (Make- L&T/CG).
Supply only power Pack. (Make- L&T/CG). Notes : (Item No 07 to 11) - The rate quoted shall be deemed to include for necessary T&P, minor spares like nuts, bolts, washers, insulation tape, lugs, compound, copper wire etc. to put in to the HT Switch Gear (VCB)/RMU in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge.
M&L for danger notice plate of 1.6mm thick mild steel sheet with vitreous enamelled with letter figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT, 25 x 20cm complete all as directed and as specified.
M&L for lightning arresters for outdoor use expulsion type suitable for HT complete with all fittings, transmission class, dis-charge capacity 33 KV, 65 KA including taking down existing lightening arresters of any type and size complete all as specified and directed.
Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6 mm thick buried directly under ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised iron earth strip 32 x 6 mm by means of bolts, nuts, check nuts, washer including test point by means of bolts, nuts, check nuts, and washers of galvanized iron and connected to main switch / control board up to 7.5 metre away from earth electrode and including GI pipe light grade 15mm bore protection pipe & necessary excavation and earth work in any strata, PCC chambers in PCC 1:3:6 type B1, RCC 1:2:4 type B1 cover slab 50mm thick with 8mm dia TMT bars at 140mm C/C both ways, with lifting handle, watering pipe of GI medium grade 20mm dia, wire mesh, funnel, lugs and charcoal, salt etc all as applicable and as per plate No 3 of SSR Part-I and all as specified.
M&L for replacement of galvanised iron strip 32 x 6mm buried in ground or fixed on pole with all accessories including dismantling old one complete all as specified and as directed.
Supplying, laying, commissioning & testing HT cable 95 Sqmm 3 core, 11000 Volts grade (Earthed), XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098 (Part-I) 1998, underground laid in trenches, ducts, pipes or on poles, etc including taking out old unserviceable cables, protection pipes/bricks or precast concrete cable cover etc complete all as specified and directed by Engr-in-Charge.
Supply & laying steel tubing, galvanized light grade bores, for passing HT cable under road or PCC floor or fixed on wall/on pole or drain etc or whenever protection is required including necessary clamps and nut bolts with GI fitting complete all as directed and specified as follows:-
(a) GI Pipe 100 mm dia.
(b) GI Pipe 80 mm dia.
Hiring of cable fault detector, to detect exact position of fault for XLPE/PVC HT cable, 11000 volts grade heavy duty aluminium conductor of any size complete all as specified and directed by Engineer-in-Charge
M&L for horizontal boring under roads/soft/loose soil of any width by manual arrangements for inserting GI pipe upto 100mm bore for laying UG cable complete all as specified and directed.
Supply and fixing in replacement cable jointing kit for 11 KV (earthed) grade cable for cable end termination indoor type cold shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm, complete all as specified and directed.
Supply and fixing in replacement cable jointing kit for 11 KV ( Earthed grade cable for cable end termination outdoor type cold shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm, complete all as specified and directed.
S&F in replacement of Cable termination cold shrinkable jointing kit for 11 KV straight through type suitable for HT cable XLPE insulated aluminium conductor of size 95 Sqmm 3 core complete all as specified and directed by Engr-in-Charge.
Aey Key Enterprises
Khan Brothers
Unnati Engineers
ENVIRO TECH SERVICES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .