| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹34.5 LAccepted-AOC | L-1 | Accepted-AOC Award of contract | |
| 2 | L-2₹28.1 L+₹7.3 L (35.3%)Rejected-Finance 201 GANAPATI SANKUL AGASHIVNAGAR MALKAPUR KARAD SATARA MAHARASHTRA 415539 | SATARA | MAHARASHTRA | 415539 | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹28.2 L+₹7.4 L (35.7%)Rejected-Finance | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹30.0 L+₹9.3 L (44.5%)Rejected-Finance SIMBAL CAMP WARD NO 5 NEAR GURUDWARA SAHIB R S PURA DISTT JAMMU J K 1812104 | R S PURA | JAMMU | J K | 1812104 | L-4 | Rejected-Finance Other than lowest bidder | |
| 5 | L-5₹31.1 L+₹10.3 L (49.7%)Rejected-Finance | L-5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
26 Jun 2023, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-900277
REPAIR, MAINT AND REPLACEMENT OF CEILING FANS, EXHAUST FANS, GEYSER, LIGHTENING CONDUCTOR, BUILDING SECURITY LIGHTS, ARRESTOR ETC AT DAMANA UNDER GE JAMMU
2023_MES_599483_1
GEJC-26/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
GE Jammu
₹80,000
Yes
4 Aug 2023
31 May 2023
28 Jun 2023
31 May 2023
26 Jun 2023
14 Jun 2023
Amount
Labour for repair/servicing of ceiling fan of any capacity complete with strip opening the ceiling fan for repair/washing/varnishing and removing of old lubricating substatances from bearing/ bush by using Kerosine oil, carrying out fresh lubrication , greasing and to make the ceiling Fan noise free and smooth functioing, including replacement of worn out/unserviceable minor spare parts split pin,fan body bolts,spring washer,fan rod bolt etc and PVC insulated, unsheathed stranded twin twisted copper conductor cable of size 1.5 Sqmm up to 1.0 M long, assembling the repaired ceiling fan and testing to the entire satisfication of engineer in charge and depositing in MES Store yard . (Replacement of Spares flexible wire etc/rewirding of ceiling fan/shall be measured and paid seperately under respective item for material and labour cost .)
Description all as per item No. 1 above but for exhaust Fan of any type mm sweep complete all as specified and directed
Description all as per item No. 1 above but for wall mounting Fan of any size/ type complete all as specified and directed
Rewinding of ceiling fan, of any make/type and size (1200 sweep) with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per manufactures specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stater/rotor, connection & testing complete all as specified and directed.
Rewinding of ceiling fan, of any make/type and size (1400 sweep) with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per manufactures specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stater/rotor, connection and testing complete all as specified and directed
Description all as per item No. 4 above but for exhaust fan of any make/type and size complete all as specified and directed.
Description all as per item No. 4 above but for wall mounting fan of any make/type and size complete all as specified and directed.
Labour for remetalling of worn out shaft of fan, cutting, brazing, machining and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in replacement of bushing system in ceiling fan and assembling the same and testing to the engineer satifaction of Engineer-in-Charge to ensure smooth and noise free operation (bearing shall be measured and paid separately).
Supply and fixing ball bearing of any size and type, suitable for any type/make/size of ceiling fan complete all as specified and directed.
Supply and fixing ball bearing of any size and type, suitable for exhaust fan of any type/make and size complete all as specified and directed.
Supply and fixing ball bearing of any size and type, suitable for wall mounted fan of any type/make and size complete all as specified and directed.
Supply, fixing in replacement of capacitor 230 Volt AC 50 Hz, conforming to IS-1709 and rated capacity 2.5 MFD for ceiling fan, exhaust fan and wall mounted fan complete all as specified and directed.
Supply, fixing in replacement of capacitor 230 Volt AC 50 Hz, conforming to IS-1709 and rated capacity 4 MFD for ceiling fan, exhaust fan and wall mounted fan complete all as specified and directed.
Supply and connection including replacement of PVC insulated, unsheathed multi stranded, three core twisted copper flexible cable of size 1.5 Sqmm complete all as specified and directed.
Supply and fixing in repair only bush of suitable size for exhaust fan of any type / size as per existing type complete all as specified and directed.
Description all as per item No. 15 above but suitable for wall mounted fan of any type / size as per existing type complete all as specified and directed.
Supply and fixing in repair of PVC connector 4 way 6 Amps with connection screws, nuts complete all as specified and directed.
Supply and fixing in repair of PVC clamps with fixing screws for holding capacitor of any type and size complete all as specified and directed.
Supply and fixing in repair of GI / MS anodized bolts with anodized nuts, spring washers, split pin etc size 50 mm long 10 mm dia half threaded type with split pin hole complete all as specified and directed.
Supply and fixing in replacement of MS clamp for down rod of suitable size including gromet / reel type rubber pad with bolts, nuts, split pin and washers suitable for housing ceiling fan complete all as specified and directed.
Supply and fixing in replacement of ceiling fan down rod 12 mm dia and 30/45 cm long complete with MS Clamp Rubber reel, split pin nut bolts etc complete all as specified and directed.
Supply and fixing in replacement of louver shutter made out of MS sheet metal 1.2 mm thick for round base and 0.8 mm thick for flaps, comprising of mounting legs frames made of MS flat strips of size 25mm x 3mm including heavy duty rust proof passivated bolts of size 50 mm long 8 mm dia to be fixed on wall at ground/First/Second floor etc complete with using fastener bolt, drilling for exhaust fan up to 400 mm sweep including taking down old one complete all as specified and directed. Notes: - (i) Rates are deemed to be including charges for hiring any type of T&P ladder, cutter etc. (ii) Contractor shall be responsible for life care of staff deployed for fixing louver shutter.
Cleaning of ceiling fan assembly of any type/size and carrying out two coats of spray painting with first quality synthetic enamelled paint of approved colour, including writing of MES number in black paint complete all as specified and directed.
Description all as per item No. 23 above but for exhaust fan upto 450 mm complete all as specified and directed.
Supply and fixing in replacement PVC canopy set of two pieces for ceiling fans of any size complete all as specified and directed.
Repair to oscillation moving part of wall mounted fan including replacement of all wornout components, bearing, lubrication and assembling complete all as specified and directed.
Supply and fixing in repair ceiling fan blade set of three pieces suitable for 1200/1400 mm sweep of White/Brown/Ivory colors complete all as specified and directed.
Taking down old unserviceable copper/aluminium point wiring concealed / batten (light, fan, socket or power) complete including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type of switch board wooden/iron, round block etc making good disturbed surfaces of walls, floors complete all as specified and directed.
Material and labour for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLS, PVC insulated (unsheathed) drawn into existing concealed PVC rigid/steel conduit and into existing CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified. Note : (a) wiring shall be done by using proper colour coding (b) Earth wire shall be of green colour (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge.
Supply and fixing in replacement for switch piano, flush type single pole one way 5Amp, 240 volts complete all as specified and directed.
Supply and fixing in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and directed
Material and labour in replacement for Sub main wiring with proper colour coding , insulated , unsheathed , multistranded ,copper conductor FRLS, cable of 2 run 4 Sqrmm for phase and neutral and one run of 2.5 Sqrmm for earth wire unsheathed , multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note : Wiring shall be done in proper colour coding.
Supply and fixing in replacement MS hooks for hanging ceiling fan with down rod and fix the same down the roof of suitable size complete all as specified and directed.
Taking down and strip opening to geyser of any make and capacity 25 / 35 / 50 ltrs including disconnection of all water pipe connection and taking out water inlet / outlet assembly, removing glass wool, the inner tank, descaling the assembly and tank, detecting the leakage, welding / brazing the defective parts, repacking the glass wool and refixing the same after making it functional including replacement of worn out nuts, bolts, washers etc complete all as specified and as directed. Note: - Cost of material and labour for providing new items shall be measured under relevant items of Schedule 'A'.
Material and labour for replacement of water inlet and outlet geyser assembly of existing make as required at site with rubber gasket suitable for geyser of 25 / 35 ltrs capacity electric driven water storage heater with provision of housing for thermostat assembly, heating element fixing arrangement nuts, bolts and washers etc complete all as specified and as directed.
Material and labour for replacement of water inlet and outlet assembly of existing make as required at site with rubber gasket suitable for geyser of 50 ltrs capacity electric driven water storage heater with provision of housing for thermostat assembly, heating element fixing arrangement nuts, bolts and washers etc complete all as specified and as directed.
Material and labour for replacement thermostat, switch for electric water heater storage type of capacity 25 / 50 ltr, 230 Volts of existing make of geyser complete all as specified and as directed.
Material and labour for replacement heating element with triangular base / round base, single phase, 230 Volt, capacity 2 KW of existing make complete all as specified and as directed.
Material and labour for replacement heating element with triangular / round base, single phase, 230 Volt, capacity 1.5 KW of existing make complete all as specified and as directed.
Material and labour for replacement pressure release valve conforming to relevant IS 15mm bore suitable for fixing with GI pipe / tubing 15mm bore complete all as specified and as directed.
Material and labour for replacement of heavy duty PVC connection (For Hot water) nylon threaded 450mm large (18") 15mm bore including brass nuts, rubber washers complete on both ends complete all as specified and as directed.
Material and labour for replacement of heavy duty PVC connection (For Cold water) nylon threaded 450mm large (18") 15mm bore including brass nuts, rubber washers complete on both ends complete all as specified and as directed.
Material and labour for replacement of indicator lamps round / rectangular type 230 Volt AC suitable for geyser of any capacity including providing electric connections complete all as specified and as directed.
Material and labour for replacement water storage inner tank of stainless steel heavy duty confirming to ISI 25 ltrs capacity geyser, with provision for fixing 15mm dia galvanized air release valve complete all as specified and as directed.
Material and labour for replacement water storage inner tank of stainless steel heavy duty confirming to ISI 35 ltrs capacity geyser, with provision for fixing 15mm dia galvanized air release valve complete all as specified and as directed.
Supply and fixing in replacement MCB SPN 32 Amps, 240 Volts, rupturing capacity 10 KA, 'C' series complete all as specified and as directed.
Supply and fixing in replacement plug top 15 Amps, 3 pins complete all as specified and as directed.
Material and labour for painting of geyser of capacity 25 / 35 / 50 ltr complete with superior quality synthetic enamel white paint by spray painting after scrapping old paint and making surface clean complete all as specified and as directed.
Material and labour for replacement of Non return Valve 15mm dia complete all as specified and as directed.
Material and labour for replacement split bottom cover (two pieces) suitable for 25 to 50 ltrs geysers complete with fixing arrangements etc as required at site complete all as specified and as directed.
Material and labour for replacement rubber gasket heavy duty of water inlet outlet assembly suitable for 25 Ltrs capacity geyser complete all as specified and as directed.
Material and labour for replacement water storage inner tank of stainless steel heavy duty confirming to ISI 25 ltrs capacity geyser with heating element assembly 1.5 KW triangular type, thermostat, indicators, 15mm dia galvanized air release valve, suitable to fix any type of water heating geyser of capacity 25 Ltrs complete all as specified and as directed.
Material and labour for replacement outer shell suitable for 25 ltrs geyser made out of GI sheet heavy duty confirming to ISI, incl new filling of glass wool and heat loss resist packing before inserting inner tank into outer tank, as suitable for existing make of geyser inner tank complete factory manufactured paint complete all as specified and as directed.
Supply and fixing in replacement glass wool suitable for geysers complete all as specified and as directed.
Repair / maintenance / servicing to solar water heater system having a capacity100 to 200 LPD complete with descaling / cleaning to flat plate, collector plate, solar heater water tanks, toughened solar glass panels, welding / breazing to solar tanks, Repair / rectification of leakage in inlet / outlet water tubing GI, checking and repair to electric system, Repair of water make up tank and make the system function cable after repair / servicing and rectification of the fault complete with and including replacement of minor spare parts complete all as specified and as directed. Note: - Spare shall be measured and paid separately.
Supply only union medium grade 25mm dia complete all as specified and as directed.
Supply only union medium grade 20mm dia complete all as specified and as directed.
Supply only rubber hose pipe with MS clamp of suitable size complete all as specified and as directed.
Supply only gun metal gate / globe valve 20mm dia complete all as specified and as directed.
Supply only rubber gasket of toughened glass complete all as specified and as directed.
Supply only painting to steel structure base frame complete all as specified and as directed.
Supply only float valve PVC 20 mm dia complete all as specified and as directed.
Supply only toughened glass panel suitable for 200 LPD solar water heater complete all as specified and as directed.
Material and labour for replacement of electrical heating element threaded type 3 KW, single phase suitable for solar water heater complete all as specified and as directed.
Material and labour for replacement of toughened collector glass of size 1.5 M X 1.0 Mtr complete all as specified and as directed
Material and labour for fasteners 80 -100mm long for fixing of geyser of capacity upto 50 ltrs including grouting completed works in wall as per site requirement with the floor complete all as specified and as directed.
Supply and fixing in replacement chromium plated CP Bib cock 15mm dia conforming to ISI complete all as specified and as directed.
Supply and fixing in replacement gun metal glove / gate valve 15mm dia internal threaded with iron wheel head conforming to ISI complete all as specified and as directed.
Supply and fixing in replacement of unserviceable bolt 16mm dia X 6" long fully threaded with counted head nuts and washer heavy duty conforming to ISI for MS column pipe / CI flanged pipe complete all as specified and as directed.
Material and labour for replacement of tubing GI "medium grade" with all fittings laid in floor or trenches including taking out old unserviceable pipe of size 15mm dia complete all as specified and as directed.
Material and labour for replacement of tubing GI "medium grade" with all fittings laid in floor or trenches including taking out old unserviceable pipe of size 20mm dia complete all as specified and as directed.
Material and labour for fixing in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB, fixing on wall suitable for geyser connection complete all as specified and as directed.
Material and labour for replacement of Rotational moulded polyethylene water storage tanks of 1000 ltr(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed.
Material and labour for replacement of submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required 2x4.0 sq. mm + 1x 4.0 sq. mm earth wire complete all as specified and as directed.
Material and labour for replacement of submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required 2x6.0 sq. mm + 1x 6.0 sq. mm earth wire complete all as specified and as directed.
Material and labour for replacement of earthing complete with galvanised steel earth plate electrode 60x60cmx6.3mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed.
Description all as per ser item No 76 here in before but using galvanised iron strip of 32X6 mm as earthing lead complete all as specified and as directed.
Supply and fixing in replacement earthing test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex head screw complete all as specified and as directed.
Material and labour for replacement of unserviceable aluminium earth strip size 25X3 mm thick complete with replacement of MS saddle/Clamp,fixing screw etc for roof conductor and down conductor above ground and on wall complete all as specified and as directed.
Description all as per ser item No 79 here in before but 25X4 mm GI strip burried in ground and fixed on wall complete all as specified and as directed.
Supply and fixing in replacement GI tubing light grade complete with fitting and fixed to wall/ceilling floor 40 mm dia complete all as specified and as directed.
Material and labour for replacement of Air termination single pointed aluminium rod 12 mm dia and 300 mm long complete all as specified and directed.
Labour for repair to existing unserviceable/Loose/Hanging GI or aluminium earth strip fix on and around the RCC reservoir complete with an including MS saddle/clamps,nut bolt,screw as per site requirement and fix the strip properly with RCC reservoir wall complete all as specified and as directed.(Note: Rates are deemed to be including charges for hiring T&P and Life insurence of person deputed at site.)
Material and labour for PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in pole foundation, stay pits etc including provision of necessary form work to aachieve fair finishes surfaces, complete all as specified and directed.
Material and labour for replacement of Lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amps, 11000 volts complete all as specified and directed.
Material and labour in replacement of Sub main wiring with proper colour coding , insulated , unsheathed , multistranded ,copper conductor FRLSH, cable of 2 run 1.5 Sqrmm for phase and neutral and one run of 1.5 Sqrmm for earth wire unsheathed , multistranded , copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed.
Material and labour in replacement of Sub main wiring with proper colour coding , insulated , unsheathed , multistranded ,copper conductor FRLSH, cable of 2 run 2.5 Sqrmm for phase and neutral and one run of 2.5 Sqrmm for earth wire unsheathed , multistranded , copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed.
Supply and fixing in replacement of ceiling rose 3 terminal surface type complete all as specified and as directed.
Supply and fixing in replacement of Bldg security light bracket made out of GI tubing suitable for 25/30/35/45 watt LED light light grade upto 0.6 mtr length, bend to shape suitable for security light fitting with necessary MS clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc and including taking out unserviceable bracket and removing from site of work complete all as specified and as directed.
Material and labour in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable flat or circular of size 10 sqmm 2 core complete all as specified and as directed.
Material and labour in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable flat or circular of size 6 sqmm 2 core complete all as specified and as directed.
Material and labour in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable flat or circular of size 4 sqmm 2 core complete all as specified and as directed.
Dismantling and taking down old unserviceable street/security lights and Material and labour for new LED street light fittings of 25 watt, suitable for upto 40 mm OD holder fixed on wall, system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection ,SMD led array with lense, cool white 6500 K, LED efficacy >90 lm/W and system efficacy 90 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC, complete all as specified and as directed.
Dismantling and taking down old unserviceable street/security lights and Material and labour for new LED street light fittings of 30 watt, suitable for upto 40 mm OD holder fixed on wall, system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection ,SMD led array with lense, cool white 6500 K, LED efficacy >90 lm/W and system efficacy 90 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC, complete all as specified and as directed.
Dismantling and taking down old unserviceable street/security lights and Material and labour for new LED street light fittings of 35 watt, suitable for upto 40 mm OD holder fixed on wall, system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection ,SMD led array with lense, cool white 6500 K, LED efficacy >90 lm/W and system efficacy 90 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC, complete all as specified and as directed.
Dismantling and taking down old unserviceable street/security lights and Material and labour for new LED street light fittings of 45 watt, suitable for upto 40 mm OD holder fixed on wall, system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection ,SMD led array with lense, cool white 6500 K, LED efficacy >90 lm/W and system efficacy 90 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC, complete all as specified and as directed.
Prakash Trading Corporation
DARVESH ENGINEERING WORKS
M/s Sahib Construction and engineers
Hi Tech Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .