Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.6 LAccepted-AOC | ₹16.6 L Quoted ₹17.2 L | 1 | Accepted-AOC Being lowest |
| 2 | 2₹18.8 LRejected-Finance SHIV NIWAS DHANDA P O TOTU DISTT SHIMLA HP 171011 | SHIMLA | SHIMLA | HIMACHAL PRADESH | 171011 | ₹18.8 L | 2 | Rejected-Finance Not being lowest |
| 3 | 3₹18.9 LRejected-Finance | ₹18.9 L | 3 | Rejected-Finance Not being lowest |
| 4 | 4₹19.5 LRejected-Finance | ₹19.5 L | 4 | Rejected-Finance Not being lowest |
| 5 | 5₹19.8 LRejected-Finance 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | ₹19.8 L | 5 | Rejected-Finance Not being lowest |
| Sl No | Description | Qty | Unit | M/S CHAUHAN ELECTRIC WORKS L7 | M/S J.B.AND SONS L6 | Vishvani Electricals L3 | Jain Traders L5 | M/S SRI JAGDAMBE TRADERS L4 | Pal Engineering Services L8 | M/S BEE ESS ENTERPRISES L9 | LARSEN AIR CONDITIONING & REFRIGERATION L1 | M/s Dinesh Kumar L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | S & F in replacement cable PVC insulated and PVC sheathed three core 1.5 sqmm copper conductor multistranded complete all as specified and directed. | 600 | RM | 71 ₹42,600 | 50 ₹30,000 | 40 ₹24,000 | 69 ₹41,400 | 35 ₹21,000 | 91 ₹54,600 | 99 ₹59,400 | 30 ₹18,000 | 20 ₹12,000 |
| 2.00 | M & L for DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 sqmm 3.5/4 core and fixed to the PCC/Steel Poles by means of suitable size of clamps with nut and bolts and all specified and directed. | 68 | Each | 800 ₹54,400 | 400 ₹27,200 | 400 ₹27,200 | 749 ₹50,932 | 670 ₹45,560 | 1,600 ₹1.1 L | 199 ₹13,532 | 400 ₹27,200 | 850 ₹57,800 |
| 3.00 | S&F in replacement LED street light 60 W made up of preessure die cast aluminium housing with polycarbonate cover and high power LEDs and secondary lenses with IP 65/66 protection 10 KV SPD included efficacy 110 LM/ 5700 K complete all as specified and directed. | 70 | Each | 2,500 ₹1.8 L | 2,800 ₹2.0 L | 2,400 ₹1.7 L | 1,249 ₹87,430 | 2,600 ₹1.8 L | 2,150 ₹1.5 L | 2,499 ₹1.7 L | 2,500 ₹1.8 L | 2,300 ₹1.6 L |
| 4.00 | S&F in replacment LED street light 70 W made up of preessure die cast aluminium housing with polycarbonate cover and high power LEDs and secondary lenses with IP 65/66 protection 10 KV SPD included efficacy 110 LM/ 5700 K complete all as specified and directed. | 70 | Each | 2,700 ₹1.9 L | 3,300 ₹2.3 L | 3,100 ₹2.2 L | 1,349 ₹94,430 | 2,800 ₹2.0 L | 2,300 ₹1.6 L | 2,999 ₹2.1 L | 3,000 ₹2.1 L | 2,600 ₹1.8 L |
| 5.00 | S&F in replacEment LED street light 90 W made up of preessure die cast aluminium housing with polycarbonate cover and high power LEDs and secondary lenses with IP 65/66 protection 10 KV SPD included efficacy 110 LM/ 5700 K complete all as specified and directed. | 50 | Each | 2,900 ₹1.4 L | 5,000 ₹2.5 L | 3,500 ₹1.8 L | 1,649 ₹82,450 | 3,700 ₹1.9 L | 3,050 ₹1.5 L | 3,499 ₹1.7 L | 3,500 ₹1.8 L | 3,800 ₹1.9 L |
| 6.00 | S&F in replacement LED Flood light 120 W made up of preessure die cast aluminium housing with polycarbonate cover and high power LEDs and secondary lenses with IP 65/66 protection 10 KV SPD included efficacy 110 LM/ 5700 K complete all as specified and directed. | 12 | Each | 7,000 ₹84,000 | 5,500 ₹66,000 | 2,050 ₹24,600 | 1,749 ₹20,988 | 5,200 ₹62,400 | 4,900 ₹58,800 | 3,999 ₹47,988 | 4,000 ₹48,000 | 5,300 ₹63,600 |
| 7.00 | S&F in replacment Post Top for 360 Degree 40W indirect light IP-65 protection Resistant to impact and coorrosion. Glare free and better uniformity complete all as specified and directed. | 5 | Each | 6,000 ₹30,000 | 5,800 ₹29,000 | 4,500 ₹22,500 | 4,449 ₹22,245 | 5,900 ₹29,500 | 2,850 ₹14,250 | 1,499 ₹7,495 | 5,000 ₹25,000 | 4,200 ₹21,000 |
| 8.00 | S & F in replacement pole mounted enclouser made of UV stabilized, FR grade special moulding compound having facility duriation base switching ON / OFF of capacity 5 KW, Three phase, with suitable size of FI clamps 02 Nos with the following accessories and all as directed. Make:-
(i) M & L for contactor 40 amps. = 01 No.
(ii) S & F in replacement of MCB 40 Amps(SP),10 KA ,240 volts. = 03 Nos
(iii) NATURE SWITCH-01
(IV) Digital time switch crono-01 Nos | 2 | Each | 25,000 ₹50,000 | 18,000 ₹36,000 | 11,000 ₹22,000 | 17,449 ₹34,898 | 16,000 ₹32,000 | 3,800 ₹7,600 | 4,999 ₹9,998 | 10,000 ₹20,000 | 14,500 ₹29,000 |
| 9.00 | M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth strip 32x6 mm by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown iln electrical plate No. 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) complete all as directed. | 4 | Each Job | 3,800 ₹15,200 | 3,500 ₹14,000 | 2,000 ₹8,000 | 3,449 ₹13,796 | 4,000 ₹16,000 | 4,250 ₹17,000 | 6,999 ₹27,996 | 5,000 ₹20,000 | 3,800 ₹15,200 |
| 10.00 | Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth and getting out soft loose soil complete all as specified and as directed for foundation of stay etc. | 110 | Cum | 110 ₹12,100 | 50 ₹5,500 | 90 ₹9,900 | 79 ₹8,690 | 120 ₹13,200 | 150 ₹16,500 | 499 ₹54,890 | 250 ₹27,500 | 150 ₹16,500 |
Updated dates
Tender Value
₹24.3 L
EMD Value
₹48,580
Closing Date
11 Dec 2025, 6:00 pmClosed
HQ CWE Agra
112, Taj Road, Agra Cantt
REPAIR / MAINT OF STREET LIGHT, GARDEN LIGHTS, GATE LIGHT FITTING, DG SET AND CONNECTED WORKS AT FATEHGARH
2025_MES_739545_1
86259/E8
Open Tender
Electrical and Maintenance Works
180 days
Fatehgarh
MES contractors enlisted for Class E and above and category b(i) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹500
Yes
₹48,580
Yes
21 Jan 2026
13 Nov 2025
18 Dec 2025
13 Nov 2025
11 Dec 2025
27 Nov 2025
13 Nov 2025 - 20 Nov 2025
Amount
S & F in replacement cable PVC insulated and PVC sheathed three core 1.5 sqmm copper conductor multistranded complete all as specified and directed.
M & L for DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 sqmm 3.5/4 core and fixed to the PCC/Steel Poles by means of suitable size of clamps with nut and bolts and all specified and directed.
S&F in replacement LED street light 60 W made up of preessure die cast aluminium housing with polycarbonate cover and high power LEDs and secondary lenses with IP 65/66 protection 10 KV SPD included efficacy 110 LM/ 5700 K complete all as specified and directed.
S&F in replacment LED street light 70 W made up of preessure die cast aluminium housing with polycarbonate cover and high power LEDs and secondary lenses with IP 65/66 protection 10 KV SPD included efficacy 110 LM/ 5700 K complete all as specified and directed.
S&F in replacEment LED street light 90 W made up of preessure die cast aluminium housing with polycarbonate cover and high power LEDs and secondary lenses with IP 65/66 protection 10 KV SPD included efficacy 110 LM/ 5700 K complete all as specified and directed.
S&F in replacement LED Flood light 120 W made up of preessure die cast aluminium housing with polycarbonate cover and high power LEDs and secondary lenses with IP 65/66 protection 10 KV SPD included efficacy 110 LM/ 5700 K complete all as specified and directed.
S&F in replacment Post Top for 360 Degree 40W indirect light IP-65 protection Resistant to impact and coorrosion. Glare free and better uniformity complete all as specified and directed.
S & F in replacement pole mounted enclouser made of UV stabilized, FR grade special moulding compound having facility duriation base switching ON / OFF of capacity 5 KW, Three phase, with suitable size of FI clamps 02 Nos with the following accessories and all as directed. Make:- (i) M & L for contactor 40 amps. = 01 No. (ii) S & F in replacement of MCB 40 Amps(SP),10 KA ,240 volts. = 03 Nos (iii) NATURE SWITCH-01 (IV) Digital time switch crono-01 Nos
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth strip 32x6 mm by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown iln electrical plate No. 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) complete all as directed.
Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth and getting out soft loose soil complete all as specified and as directed for foundation of stay etc.
Returning, filling in, including spreading, levelling, watering and well remmining in layers not exc 25 cm.
Removing excavated material n.exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point all as directed.
Supply and laying DWC high density polyethelene pipes having dia 63/50 mm, inner dia as per site having corrugation on the wall and plain surfaces on the inner wall conforming to IS-14930 (Part-I & II) for protection of under ground cable laid along pole/along wall/ in PCC/GL Roof and including all fittings as required at site complete all as specified and directed.
Boring holes horizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI machenical equipments for insersion of tubing not exc 80 mm bore(dia) for passing UG cable, complete all as specified and as directed. NOTE : - GI Pipe laid will be measured and paid separately under respective item
S&F in replacement of 40 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified and directed .
Taking out unserviceable LT UG cable from trenches 6 Sqmm to 10 Sqmm size 2/4 core complete all as specified and as directed.
Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 10 Sqmm 4 core complete all as specified
Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 6 Sqmm 2 core complete all as specified
Repair & comprehensive maintenance of 180 KVA capacity DG set of any make of the following capacities which include replacement of worn out spares such as fuel filter, oil filter, engine oil, hoses, V- belt, Oil pipes, fuel pipe, water pump, cut out and tightening of nut bolts, washers etc and testing on completion of repair complete all as specified and directed.
All as per item No.19 here-in-before but Repair & comprehensive maintenance of 100 KVA capacity DG sets
All as per item No.19 here-in-before but Repair & comprehensive maintenance of 82.5 KVA capacity DG sets
All as per item No.19 here-in-before but repair & comprehensive maintenance of 40 to 62.5 KVA capacity DG sets
All as per item No.19 here-in-before but repair & comprehensive maintenance of 20 to 35 KVA capacity DG sets
Supply only the following spare parts for 180 KVA DG Set of Make: Greaves Cotton
(a) Air Filter inner and outer
(b) Fuel Filter
(c) Lubricating Oil Filter
Supply only the following spare parts for 100 KVA of Make: Kirloskar/Greaves Cotton/ cumins
(a) Air Filter inner and outer
(b) Fuel Filter
(c) Lubricating Oil Filter
Supply only the following spare parts for 82.5 KVA of Make: Kirloskar/Greaves Cotton/Ashok Leyland
(a) Air Filter inner and outer
(b) Fuel Filter
(c) Lubricating Oil Filter
Supply only the following spare parts for 40 to 62.5 KVA of Make:- Kirloskar / Greaves Cotton
(a) Air Filter inner and outer
(b) Fuel Filter
(c) Lubricating Oil Filter
Supply only the following spare parts for 20 to 35 KVA of Make:- Kirloskar / Greaves Cotton
(a) Air Filter inner and outer
(b) Fuel Filter
(c) Lubricating Oil Filter
Dismantling and taking down radiator assy from engine of any capacity for repairs including de-scaling, brazing as necessitated to plug leakages and for transporting of the radiator of capacity 20-35 KVA and repair/maintenance to the radiator fins with the help of cleaning coil solution and cleaning to the radiator complete and repair to the leakage places by means of gas welding and including initial filling up coolant and re fixing after repairs including replacement of worn out nut bolts, washers etc; and testing complete all as directed.
Ditto as above but of capacity 100-180 KVA
Dismantling and removing Fuel injection pump (FIP) from DG set of 20 to 35 KVA capacity for repairs including calibration at authorised service centres, replacement of necessary spare parts such as delivery valves, plunger, 'O' ring, springs etc and refixing, testing complete all as specified & directed.
All as per item No.31 here-in-before but DG sets of for 40 to 62.5 KVA capacity
S&F in replacement of Fuel Injection pump of DG sets of 20 to 35 KVA capacity
S&F in replacement of Fuel Injection pump of DG sets of 40 to 62.5 KVA capacity
M&L for cleaning of fuel tank of DG sets of any make and capacity including replacement of fuel level indicating tube and markings all as specified
M&L in replacement of engine Oil Grade 20 W 40 ( Make :- Castrol / Servo )
S & F Self Starter 12 V DC suitable for DG Set 20 to 35 KVA
S & F Self Starter 12 V DC suitable for DG Set 40 to 62.5 KVA
Repair / Overhauling of self starter 12 / 24 Volt of any make / capacity including replacement of minor items such as carbon brushes, nuts, bolts etc and replacement of defective/unserviceable parts all as necessary to make the self starter functional and testing on completion NOTE : (i) Spares required/parts replaced shall be measured and paid seperately under respective items of this Schedule as supply only. (ii)The labour & fixing charges for the items replaced are deemed to be included in the rates quoted for above items.
Supply only of Field coil of self starter 12 / 24 V
Supply only of Armature of self starter 12 / 24 V
Supply only of Clutch assembly of self starter 12 / 24 V
Servicing of alternator of battery charging unit (12 Volt) including replacement of worn out parts such as bearings, winding, auto cut unit , mounting clamps etc complete to made functional to charge 12 V DC Battery
Supply only of battery lead, copper conductor 25 Sq mm, multi stranded, PVC insulated with suitable copper lugs/terminals at both ends all as specified and directed.
Supply & fixing in replacement battery terminls of brass suitable for 12V, 180/92 AH battery all as specified and directed.
S & F in replacement of Battery charger suitable for charging 1 x 12 V Battery with external wiring with 2 x 1.5 sqmm copper conductor not more than 5 mtr, complete all as specified and directed.
S&F in replacement of unservieable Fan belts as per existing sample for 100/180 KVA capacity DG sets complete all as specified and directed.
S&F in replacement of unservieable Fan belts for DG sets of 20 / 35 / 40/ 45/50/ 62.5 KVA capacity complete all as specified and directed.
S&F in replacement of fuel flexible pipe, heavy duty with check nuts for DG sets of any make/capacity complete all as specified and directed.
Dismantling of alternator assembly 20/ 35 / 40 / 45 /50/62.5 KVA DG Sets and taking out regulating transformer carefully and rewinding of regulating transformer including refitting and testing complete all as specified and directed.
S&F in replacement of only oil pressure gauge as per sample complete all as specified and directed.
S&F in replacement of only water temperature gauge as per sample complete all as specified and directed.
S&F in replacement of unserviceable water pump of DG sets of 20 /35 KVA capacity complete all as specified and directed.
S&F in replacement of unserviceable water pump of DG sets of 40 / 62.5 KVA capacity complete all as specified and directed.
S&F in replacement of Coolent additive concentrate pack suitable for DG Set complete all as specified and directed.
Supply only Distilled water in 5 ltr PVC Container complete all as specified and directed.
S&F in replacement of alternator cutout assembly suitable for 82.5 - 180 KVA DG Set complete all as specified and directed.
S&F in replacement of alternator cutout assembly suitable for 20/ 35 KVA D G set complete all as specified and directed.
S&F in replacement of alternator cutout assembly suitable for 40/ 45 /50/62.5 KVA D G set complete all as specified and directed.
Supply and fix in replacement of Engine Safety unit suitable for 40 to 100 KVA DG Set complete all as specified and directed.
Supply and fix in replacement of Thermostate suitable for 20 to 35 KVA DG Set complete all as specified and directed.
Supply and fix in replacement of Thermostate suitable for 40 to 62.5 KVA DG Set
Supply and fix in replacement of Thermostate suitable for 82.5 to 180 KVA DG Set complete all as specified and directed.
Supply and fix in replacement of alternator 12 Volt DC suitable for battery charging including mounting clamp, nut bolts washers etc complete all as specified and directed.
Supply and fix in replacement Battery 12V,180AH heavy duty complete suitable for DG sets. Make :- Exide or equivalent as approved by AGE(I).
Supply and fix in replacement Battery 12V,120 AH heavy duty complete suitable for DG sets. Make :- Exide or equivalent as approved by AGE(I).
S & F Retrofit Emission Control Device suitable for controlling of emission as per CPCB Norms 2022 on 62.5 KVA DG Set complete all as specified and directed
All as per item No. 67 here-in-before but for 50 KVA DG Set
S & F in repair of MCCB 100 Amps, 4 pole, 415 volts, 50 Hz 25 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides complete all as specified and directed
S & F in repair of Off load Changeover switch 200 Amps 4 pole complete all as specified and directed
M/s Dinesh Kumar (BID ID -3495479)
Vishvani Electricals (BID ID -3489321)
M/S SRI JAGDAMBE TRADERS (BID ID -3494688)
Jain Traders (BID ID -3490719)
M/S J.B.AND SONS (BID ID -3489097)
M/S CHAUHAN ELECTRIC WORKS (BID ID -3488962)
Pal Engineering Services (BID ID -3495485)
M/S BEE ESS ENTERPRISES (BID ID -3489544)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.12 MB
BOQ_828082.xls
BOQ • 9.20 MB
TENDER.pdf
Tender Documents • 0.39 MB
AppxG.pdf