Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAdmitted-Finance | ₹12.6 L | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | JABBAR FAYAS L1 |
|---|---|---|---|---|
| 1.00 | OPENWELL SUBMERSIBLE PUMPSET AS PER IS 14220 / 2002 WITHOUT
PANEL BOARD
Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as
amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all
causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed
type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as
per IS 613/1984 with ISI mark. The pump suitable for installation in sump with 1.1KV grade 3
core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The
non-return valve located at the top of the pump in the discharge outlet connection is to be designed
with minimum friction. The pump should be directly coupled to 2880 RPM, three phase,
50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP,
Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP
starting and for continuous operation. 1500 LPM X 40m Head TWAD 2025-2026 Page.no:125 | 3 | No | 1,24,088.33 ₹3,72,264.99 Lowest |
| 2.00 | THREE PHASE PANEL BOARD STAR- DELTA WITH TWO LEVEL GUARD
AND AUTO START
Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended
thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V
(+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated
Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch,
Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard
higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button
switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin
proof box, including the capacitor (the cost of capacitor is to be taken separately). TWAD 2025-2026 Page.no:134 | 3 | No | 27,418.46 ₹82,255.38 Lowest |
| 3.00 | 200 A Fues carrier | 3 | No | 513.18 ₹1,539.55 Lowest |
| 4.00 | Earth plate | 1 | No | 3,447.5 ₹3,447.5 Lowest |
| 5.00 | 4 core 50 sqmm UG Copper cable | 50 | Rm | 2,072.44 ₹1,03,622 Lowest |
| 6.00 | 4 core 25 sqmm UG Copper cable | 200 | Rm | 1,009.62 ₹2,01,925 Lowest |
| 7.00 | 50 sqmm lugs | 6 | No | 29.55 ₹177.3 Lowest |
| 8.00 | 50 sqmm cable gland | 20 | No | 57.13 ₹1,142.6 Lowest |
| 9.00 | 25 sqmm lugs | 15 | No | 24.62 ₹369.38 Lowest |
| 10.00 | 25 sqmm cable gland | 60 | No | 44.33 ₹2,659.5 Lowest |
Tender Value
₹16 L
EMD Value
₹16,000
Closing Date
13 Aug 2026, 3:00 pmClosed
The Commissioner Dharmapuri Municipality
The Commissioner Dharmapuri Municipality
Supply and fixing of 30 HP Submersible motor with 200 Amps panel board and electrical works at ward 29 Salem Main Road Nethaji Byepass roadBooster B1 Police Station in Dharmapuri Municipality
2026_MAWS_691042_1
1605/2026/E1_8
Open Tender
Civil Works - Water Works
Works
Dharmapuri Municipality
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹16,000
14 Aug 2026
5 Aug 2026
13 Aug 2026
5 Aug 2026
13 Aug 2026
5 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | OPENWELL SUBMERSIBLE PUMPSET AS PER IS 14220 / 2002 WITHOUT
PANEL BOARD
Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as
amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all
causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed
type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as
per IS 613/1984 with ISI mark. The pump suitable for installation in sump with 1.1KV grade 3
core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The
non-return valve located at the top of the pump in the discharge outlet connection is to be designed
with minimum friction. The pump should be directly coupled to 2880 RPM, three phase,
50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP,
Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP
starting and for continuous operation. 1500 LPM X 40m Head TWAD 2025-2026 Page.no:125 | 3 | No | - | - |
| 2 | THREE PHASE PANEL BOARD STAR- DELTA WITH TWO LEVEL GUARD
AND AUTO START
Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended
thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V
(+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated
Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch,
Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard
higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button
switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin
proof box, including the capacitor (the cost of capacitor is to be taken separately). TWAD 2025-2026 Page.no:134 | 3 | No | - | - |
| 3 | 200 A Fues carrier | 3 | No | - | - |
| 4 | Earth plate | 1 | No | - | - |
| 5 | 4 core 50 sqmm UG Copper cable | 50 | Rm | - | - |
| 6 | 4 core 25 sqmm UG Copper cable | 200 | Rm | - | - |
| 7 | 50 sqmm lugs | 6 | No | - | - |
| 8 | 50 sqmm cable gland | 20 | No | - | - |
| 9 | 25 sqmm lugs | 15 | No | - | - |
| 10 | 25 sqmm cable gland | 60 | No | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.70 MB
BOQ_830891.xls
BOQ • 0.28 MB
Biddocument13.pdf
Tender Documents • 0.30 MB
30HP.pdf
PDF • 1.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .