| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 LAccepted-AOC | ₹18.7 L | L1 | Accepted-AOC THE LOWEST TENDERER |
| 2 | L2₹20.1 L+₹1.4 L (7.35%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | ₹20.1 L+₹1.4 L (7.35%) | L2 | Rejected-Finance NOT THE LOWEST TENDERER |
| 3 | L3₹20.2 L+₹1.5 L (7.98%)Rejected-Finance | ₹20.2 L+₹1.5 L (7.98%) | L3 | Rejected-Finance NOT THE LOWEST TENDERER |
| 4 | L4₹22.4 L+₹3.7 L (19.7%)Rejected-Finance | ₹22.4 L+₹3.7 L (19.7%) | L4 | Rejected-Finance NOT THE LOWEST TENDERER |
| 5 | L5₹29.6 L+₹10.9 L (58.2%)Rejected-Finance | ₹29.6 L+₹10.9 L (58.2%) | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
14 Sept 2024, 6:00 pmClosed
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
REPAIR REPLACEMENT TO VARIOUS DBs INTERNAL LIGHT FIXTURES AND CERTAIN RERPAIR TO CEILING FANS EXHAUST FANS AND GEYSERS AT MD ACCN OF DGQA ORG UNDER GE MH AND RH KHADKI
2024_MES_667881_1
8578/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹54,000
29 Oct 2024
25 Jul 2024
17 Sept 2024
25 Jul 2024
14 Sept 2024
8 Aug 2024
25 Jul 2024 - 15 Aug 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking into credit (credit for above items shall be made as per condition laid down under schedule of credit seprately ) and making good disturbed surfaces of walls, floors etc all as specified.
M&L for point wiring using approved colour coding as per IS ( Red, black and green for single phase circuits), with multi stranded copper conductor 1.5 Sqmm nominal cross sectional area,single core, PVC insulated and sheathed FRLS cable1100 volts grade , ISI-694 (1990) marked with valid CML No in and including medium grade,PVC casing & capping of suitable size on walls/roof/floor etc, ISI marked with suitable accessories , mild steel/ pressed steel sunken box of 1.2 mm thick and 60 mm deep ( with earth dolly ) duly painted with two coat of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide externally , covered with 3 mm thick plasticlaminated sheet cover for fixing of switches, sockets and fan regulator etc, including PVC insulated multistranded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engr-in-charge for the following :- Make: polycab /Finolex/ RR
One fan/light /bell point controlled by one switch/bell push
One switch socket outlet 5 Amps on independent board
One socket outlet 5 Amps on the same board
All as per Item No 2 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated but sheathed copper conductor FRLS cable 1100Volts grade and 2.5 sqmm as earth continuity conductor for one switch socket outlet 15 Amps on independent board complete all as specified and directed by Engr- in - Charge.
All as per Item No 2 here-in-before but with 4.0 Sqmm PVC insulated multistranded copper conductor cable including 4.0 sqmm PVC insulated but unsheathed copper conductor FRLS cable 1100Volts grade and 4 sqmm as earth continuity conductor for power socket on independent board complete all as specified and directed by Engr- in - Charge.
M&L for point wiring using approved colour coding as per IS ( Red, black and green for single phase circuits), with multi stranded copper conductor 1.5 Sqmm nominal cross sectional area,single core, PVC insulated and unsheathed FRLS cable1100 volts grade , ISI-694 (1990) marked with valid CML No in and including medium grade,PVC Conduit of suitable size on walls/roof/floor etc, ISI marked with suitable accessories , mild steel/ pressed steel sunken box of 1.2 mm thick and 60 mm deep ( with earth dolly ) duly painted with two coat of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide externally , covered with 3 mm thick plasticlaminated sheet cover for fixing of switches, sockets and fan regulator etc, including PVC insulated multistranded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engr-in-charge for the following :- Make polycab /Finolex/ RR
One fan/light /bell point controlled by one switch/bell push
One switch socket outlet 5 Amps on independent board
One socket outlet 5 Amps on the same board
All as per Item No 5 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated but unsheathed copper conductor FRLS cable 1100Volts grade and 2.5 sqmm as earth continuity conductor for one switch socket outlet 15 Amps on independent board through medium PVC conduit complete all as specified and directed by Engr- in - Charge.
All as per Item No 5 here-in-before but with 4.0 Sqmm PVC insulated multistranded copper conductor cable including 4.0 sqmm PVC insulated but unsheathed copper conductor FRLS cable 1100Volts grade and 4 sqmm as earth continuity conductor for power socket on independent board through medium PVC conduit complete all as specified and directed by Engr- in - Charge.
M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into PVC Cassing capping of suitable size including 4.0 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including chislling/cutting of wall, floor, making hole through wall & making good disturbed surfaces of wall/floor/ceiling to match with existing surface including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note: Two single core cable, earth wire and PVC conduit shall be measured as one length.
All as per item no 08 above but of 6 Sqmm
Supply and fix in repair ceiling rose surface bakelite with three terminals type in all as specified and directed.
Supply and fix in repairs switch piano type one way 6 Amps flush type ,240volt AC all as specified and directed.
Supply and fix in repairs socket outlet 2 in1,3 pin 5 Amps all as specified and directed.
Supply and fix in repairs switch socket combination(SSC) 2 in 1, 3 pin, 5 Amps flush type ,240volt AC all as specified and directed.
Supply and fix in repairs switch piano type 16 Amps flush type ,240volt AC all as specified and directed.
Supply and fix in repairs socket outlet 2 in 1, 3/ 5 pin 16 Amps flush type all as specified and directed.
Supply and fix in repairs switch socket combination(SSC) 2 in 1, 3/5 pin, 16 Amps flush type ,240volt AC all as specified and directed.
Supply and fix in repairs Bell push, flush type, 6 Amp flush type ,240volt AC all as specified and directed.
Supply and fix in repairs switch piano type two way 6 Amps flush type ,240volt AC all as specified and directed.
Supply and fix in repairs Bell push, Modular type, 6 Amp flush type ,240volt AC all as specified and directed.
Supply and fix in repair modular switch 1 way 6A 1 module complete all as specified and directed.
Supply and fix in repair modular switch 2 way 6A 1 module complete all as specified and directed.
Supply and fix in repair modular socket 6A 2/3 pin combined 2 module complete all as specified and directed.
Supply and fix in repair modular socket 6A /16A 2/3 pin combined 2 module complete all as specified and directed.
Supply and fix in repair modular fan regulator,120 watt - 2 module complete all as specified and directed.
S & Fix in repair stepped type electronic fan regulator 120 watt ,240 olt flush type on the existing phenolic laminated sheet
Supply and fix in repair electric bell Ding Dong, AC 230 volts complete all as specified and directed.
Supply and fix in repair Modular white cover plate with frame of following size complete all as specified and directed.
1 module
2 module
3 module
4 module
6 module
8 module
Supply and fixing replacement of RCCB 63 A , four pole, 30 mA all as specified and directed by Engr-in-chrge. Make: Hager/L & T/Standard
Supply and fix in industrial wall mounted plug socket suitable fotr IP 44 degree of protection of 32Amps rating 3p+N +E all as specified and directed. Make: L&T cat part DBPPS563SD or other equivalent make all as specified and directed
S & F sheet metal enclosures for double door distribution board factory made duly painted of following capacity with 200 amps rated bus bar , suitable for fixing MCB /Isolators all as specified Make:L & T/legrand/Havells or equivalent.
12 way SPN , 240V
8 way SPN 240V
4 way TPN ,415V
8 way TPN ,415V
S & F MCCB 125 Amps, 4 pole, Breaking capacity 16 KA, 415 V adjustable type all as specified of capacity Make: L &T /Legrand/Indoasian/standard.
All as per item no 31 Above but of capacity 100 Amps.
Supply and fixing miniature circuit breaker (MCB) of following current carrying capacity, in the MCB DB complete with connection testing and commissioning. Make L &T /Legrand/Havells
SP 5/6 to 32 AMP,240V, 10 KA 'B' curve
SP 40 AMP,240V, 10 KA 'B' curve
SPN 32 Amps,240V, 10 KA 'B' curve
SPN 40 Amps ,240V, 10 KA 'B' curve
TPN 63Amps,240V, 10 KA 'B' curve
Taking down old unserviceable fitting and S & F wall mounted extruded aluminium housing high quality indoor batten of following capacity colour temperature 6500 K (4' long) lumen 2000 -3000, PF> 0.9, THD less 15% diffused connecting with three core flexible copper wire from connecto to ceiling rose/angle holder as per existing site requirement as directed by Engr-in-charge. Make : Havells/wipro/Halonix
LED tubelight fitting of 20 watt/22 watt , 4 Ft long
LED tubelight fitting of 10watt, 2 Ft long
Taking down old unserviceable Tube light fitting of any type and S & F wall/ceiling mounted Inverter LED tube light fitting 4' feets long with opal diffuser and having aluminium body. Energy efficient high quality invertor batten should have Lithium ion battery of 3.7V, 19 WH having inbuilt battery backup upto 2Hrs with high power brightness having BIS certification, LED fitting should be LM 80 certified with system efficacy greater than 100 lumens/watt, including LED tube 20/22 watt having colour temperature 6500 K , PF> 0.95, THD less 10%, with IP20 protection having open and short circuit protection, having input voltage range 90V to 300V connecting with three core flexible copper wire from connector to ceiling rose/angle holder as per existing site requirement as directed by Engr-in-charge. Make : Havells/Jaquar/Halonix/Crompton . Note :- The rates are inclusive of cost of square box-02 nos including suitable size of clamps and screws etc.
Taking down old unserviceable fitting and S & F Recess mounting LED flat panel light fitting of following wattage and size with efficient LEDs lumen 2000 -3000, PF> 0.9, THD less 15% including taking down unserviceable fitting of any type and make all as specified and directed. Make : Havells/wipro/Halonix
36 watt, 2 x 2 , 600mm x 600 mm size
18/20 watt, (1x1 )ft
Circular in size 18/20 watt not less then 6 '' dia
Taking down old unserviceable fitting and S & F wall mounted high quality indoor wall bracket light cylinderical/oval shape aesthetically designed fitting with B22D lamp holder and 12 Watt bulb temp range 4000k to 6500 K as per site requirement connecting with three core flexible copper wire as directed by Engr-in-charge. Make : Halonix cat No: HLWB-01-B22 or evivalennt Havells/wipro
Taking down old unserviceable Bldg security light S&F fix high efficent LEDbuilding security light 30 watt , 230 V , lumen 2000 -3000, PF> 0.9, THD less 10%, made of pressutre cast aluminuim housing with high power LEDs, lens and touughned glass IP 66 connecting with three core flexible copper wire from connecto to ceiling rose. Make : Halonix ,Bajaj,Havells or equivalent.
S & F in repair bracket for mounting building security light made out of 40 mm dia Light Grade GI pipe bend in angle with holding MS clamps two nos each bracket ox size 25x3 mm including screw etc for fixing all as specidfied and directed by Engr-in-charge
M & L for earthing complete in repairs with galvanised steel earth plate electrode 600 mm x 600 mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to 4.0 mm dia galvanised earth lead wire by means of nuts bolts check nuts and GI washers including PCC pit in PCC 1:2:4 type B-1 RCC cover 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical plate No 3 as specified, GI wire suitable size and length for continuity earth wire from test point to main distribution Board and all as directed. Note: (i) Rate for achieving required depth by compressor machine if required is deemed included in item unit rate. (ii) After earthing contractor should test the earth value and submit register for earth resistance result to Engr-in-Charge.
M & L for repairs /re-fixing on exiting or new location to storage type electric water heater (geyser) of storage capacity 25/35/50 ltrs of any make comprising of the following works mentioned here under againt Ser Nos (a) to (f) at different locations (a) Inspection, taking down, opening ( dismantling ) descaling, brushing, cleaning of storage tank (b) Examine water tightness of storage tank after cleaning. (c) Carry out operation of all stop cocks, pressure reducing valves etc. to ensures free movement of the working parts. (d) S & F Replacement of the rubber / PVC gasket to ensure water tightness. (e) Checking of safety valve (f) Testing of geysers after repairs.
S & F in repairs thermal cutout ISI marked temp range 50-80/90 degree as required at site for geyser of capacity 25/35/50 Ltr of any make all as directed by Engr-in-charge
S & F in repairs of safety valve/high pressure valve ISI marked as per site requirement or all as per directed by Engineer-in-Charge.
S & F in repairs heating element of following rating as required at site including rubber washers all as specified and directed by Engr-in-charge..
1/1.5 KW,240 volt
02 KW ,240 volt
S & F in repairs of PVC pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 60 cm long for cold water connection all as specified and directed by Engr-in-Charge
S & Fixing in repairs metal braided PVC/CP pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 45 CM long for hot water connection all as specified and directed by Engineer-in-charge.
S & Fixing in repairs, non return valve 15 mm dia of brass, ISI marked all as specified and directed by Engineer-in-charge.
S & F stop valve , cast copper alloy screw down high pressure crutch handle, screwed both end for iron pipe suitable for 15 mm bore all as specified and directed by Engr-in-Charge
M & L for repairing and replacment of unserviceable copper container of capacity 25/50 Ltrs of solar water heater of any type after completion of work testing the heater all as specified and directed by Engr-in-Charge
Copper container 50/100 ltr
Copper container capacity 25 Ltrs of water heater (gyeser)
M & L for rewinding of Ceiling Fan, Exhaust Fan and Air circulator of any type/make by split opening the fan carrying cutting the burnt winding and cleaning the slots and rewinding with super enamelled copper winding wire appropriate gauge including connection,capacitor base and testing complete all as specified and directed by Engr-in-Charge. Note: (a) Bearing ,fan canopy, capacitor, down rod etc will be measured and paid separately under relevant item of schedule.
Ceiling fan of 1200/1400 mm sweep
Exhaust Fan of sweep 275-300 mm
Exhaust Fan of sweep 350-450 mm
Air circulator of sweep 350-450 mm
Supply only ball bearing (DE/NDE) to match the existing make suitable for 1200/1400 mm sweep ceiling fan including greasing complete all as specified and directed by Engr-in-Charge. Make: SKF/NBC
Supply only ball bearing suitable for 275-450 mm exhaust fan complete all as specified and directed Make : SKF/NBC or equivalent
Supply only fan capacitor of following capacity
capacitor 2.5 mfd
capacitor 4 mfd
Supply only , rubber yoke, MS Clamps, bolts nuts with split pin suitable for ceiling fan 1200 /1400 mm sweep complete all as specified and as directed by Engr-in-charge.
Supply only gunmetal bush suitable size for ceiling fan 1200 /1400 mm sweep complete all as specifed and directed by Engr-in-Charge.
supply only fan down rod of following length with white enammbeled painted with both side hole for hanging fan of sweep 1200/1400mm sweep all as specifeied and directed by Engr-in-charge
1 ft long
2 ft long
Supply only stator for ceiling fan of 1200/1400 mm sweep with silicon coating, anti rust coating, size and slot as per sample, feasible to fix in exisiting rotor size all as specified and directed
Supply only rotor for ceiling fan of 1200/1400 mm sweep with silicon coating, anti rust coating, size and slot as per sample, feasible to fix in exisiting stator size all as specified and directed
Supply only fan canopy set off white /white coloured as per colour of ceiling fan of sweep1200/1400mm all as specified and directed.
Taking down old/new electric meter three phase/single phase, taking it to testing lab as approved by State electricity board or NABL approved lab calibarating it and reparing it if rejected in testing parameters of the testing authorities . Refixing the meter back to the site with proper nut bolts, washers/fastners and suitable size of connecting pvc copper wire as per reqd length. Note:- (i) Test certificate/calibration report of the electric meters to provided by the contractor (ii) The meter is to be fixed on wooden board of thickness not less than 8 mm of size as per the site requirement. (iii) The rates are all inclusive of dismantling, transporting, repairing , calibrating and refixing back on wooden board of thickness not less than 8 mm to its original place. (iv) Contractor has to install new meter issued from the dept before dismantling the old meter. (v) The meters will not be given in complete lot , meters will be given as and when required basis or as directed by the Engr-in-charge. (vi) All minor spares such as CT's power convertor, circuit board,(PCB), resistors, terminal covers etc as required are included in quoted rates.
Supply and replace hylum sheet 3 mm thick for Junction boxes, circuit boxes for various size and refixing the existing switches, sockets, regulators cut in to requied sizes including fixing with new cadmium plated screws and cup washers complete all as specified and as directed.
M & L for replacement of PVC polycarbonate rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of following size make cutting for fixing existing switches, sockets, regulators and make necessary connection and testing complete all as specified and directed by Engr-in-Charge.
100 x 100 mm and 50 mm deep
200 x 150 x 50 mm deep
250 x 200 x 50 mm deep
150 x 150x 50 mm deep
Decarbonizing of indoor MCB DB's / Meter box panel and distribution panel of bldgs by dismantling the old MCCB's, old Bus bars , cable connections, old Amps meter and old voltmeter and cleaning the panel with ctc sovent, and removing the old/burnt control wiring, replacing the old/burnt bus bar of any size if any and fixing properly the hanging/loose front and rear opening doors of the panels, by welding of hinges including welding of broken MS sheet using extra sheets of required size also replacing burnt thimbles with new existing size thimbles, indicator lamps, including powder coating painting of panel with suitable 'U' type gasket to make it dust and vermin proof, providing fancy locks incluidng dismantling the existing connected cables and re-connecting the same cables complete all as specified and directed by Engr -in- charge.
ONKAR ELECTRIC AND GENERAL STORE (BID ID -3096270)
ANUSHKA BUILDERS (BID ID -3095553)
SHREE VAIBHAV ELECTRICALS (BID ID -3090408)
PURVA ELECTRICALS AND ENGINEERS (BID ID -3091216)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .