Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.9 LAccepted-AOC 1074 BAGYALAKSHMI STREET VENKATESAPURAM ARAKKONAM 631002 | ARAKKONAM | RANIPET | TAMIL NADU | 631002 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹53.7 L+₹2.4 L (4.64%)Rejected-AOC 03 PATEL STREET GANDHI NAGAR AVADI TIRUVALLUR TAMIL NADU 600054 | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹53.7 L+₹2.4 L (4.75%)Rejected-AOC NO 51 TOWN HALL 3RD STREET ARAKKONAM TAMIL NADU 631 001 | ARAKKONAM | RANIPET | TAMIL NADU | 631001 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹57.0 L+₹5.7 L (11.1%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹57.1 L+₹5.8 L (11.3%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹99,600
Closing Date
9 Jan 2021, 6:00 pmClosed
Garrison Engineer (M) NAS Arakkonam
Garrison Engineer (M) NAS Arakkonam-631006
OUTSOURCING OF SERVICES FOR OPERATION OF DG SET INSTALLATION AND MAINTENANCE INCLUDING REPAIRS TO DG SETS OF VARIOUS CAPACITIES INSTALLED AT VARIOUS LOCATIONS UNDER GE M ARAKKONAM
2020_MES_407490_1
8959E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Arakkonam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer (M) NAS Arakkonam
₹99,600
Yes
13 Jan 2021
29 Dec 2020
11 Jan 2021
29 Dec 2020
9 Jan 2021
2 Jan 2021
30 Dec 2020 - 1 Jan 2021
Amount
Outsourcing of services for operation of DG Set installation Round the clock (including Sunday and Holiday) at Wire less Transmissionwith following tradesmen for Installations as mentioned below complete all as specified and as directed by Engineer-in-Charge:- (A). WIRELESS TRANSMISSION (a) FGM ( Skilled) - 03 Nos ( 01 No per shift) for 3 shifts per day. (b) Each shift shall be 08 hours as directed. DETAILS OF PLANTS (i) Diesel Generating set 100 KVA Capacity , Make: Ashok Leyland -1 No. (ii) Diesel Generating set 15 KVA Capacity , Make: kirlosker -1 No. (iii) Genset Control Panel for 100 KVA - 1 No,LT panels, APFC panel,Change over switch of any capacity/type,LT stabiliizer.
Outsourcing of services for operation of DG Set installation round the clock (including Sunday and Holiday) at Magazine (Sub- station-J) as mentioned below complete all as specified and as directed by Engineer-in-Charge:- (A). MAGAZINE (a) FGM ( Skilled) - 03 Nos ( 01 No per shift) for 3 shifts per day. (b) Each shift shall be 08 hours as directed. DETAILS OF PLANTS (i) Diesel Generating set 200 KVA Capacity,Make:Kirloskar Green - 1 No (ii) Diesel Generating set 400 KVA Capacity,Make:Kirloskar Green - 1 No (iii)Diesel Generating set 62.5 KVA Capacity,Make:Cummins/Powerica - 1 No (iv)DG Set AMF Panel - 3 Nos, APFC panel,Change Over Switch of any capacity/type and LT panels
Outsourcing of services for operation of DG Set installation round the clock (including Sunday and Holiday) at Localizer Building as mentioned below complete all as specified and as directed by Engineer-in-Charge:- (A). LOCALIZER (a) FGM ( Skilled) - 03 Nos ( 01 No per shift) for 3 shifts per day. (b) Each shift shall be 08 hours as directed. DETAILS OF PLANTS (i) Diesel Generating set10 KVA Capacity, Make:Kirloskar Oil engines -1 No (ii) Diesel Generating set 15 KVA Capacity ,Make:Kirloskar Oil engines -1No (01 No Stand by)
Outsourcing of services for operation of DG Set installation for Two shifts per day(including Sunday anfd holiday) at Processing unit sub station as mentioned below complete all as specified and as directed by Engineer-in-Charge:- (A). Processing unit substation (a) FGM ( Skilled) - 02 Nos ( 01 No per shift) for 2 shifts per day. (b) Each shift shall be 08 hours as directed. DETAILS OF PLANTS (i) Diesel Generating set 500 KVA Capacity, Make: Kirloskar Green -01 No (ii) Diesel Generating set 400 KVA Capacity , Make:Cummins/Powerica-01 No (iii) fire fighting pump set incld all accessories, LT panels and AMF Panels
Outsourcing of services for operation of DG Set installation round the clock (including Sunday and Holiday) at SICK BAY (Sub- station - I) as mentioned below complete all as specified and as directed by Engineer-in-Charge:- (A). SICK BAY S/S I (a) FGM ( Skilled) - 03 Nos ( 01 No per shift) for 3 shifts per day. (b) Each shift shall be 08 hours as directed. DETAILS OF PLANTS (i) Diesel Generating set 62.5 KVA Capacity, Make:Kirloskar Cummins -1 No (ii) Diesel Generating set 30 KVA Capacity , Make:Kirloskar Cummins -1 No Notes for srl item No. 1 to 5 (i) Diesel for DG Sets will be issued by department as free for filling only from MTsection / MES store yard.Arakkonam No transport and labour will be provided by department for shifting of POL and the Contractor shall arrange labour,Transport , materials, tools and operating staffs etc., for collection and shifting of POL to the sites. (ii) Operator must be skilled and must have knowledge of Operation and general maintenance of DG Sets and attending minor faults whenever arise. (iii) Operator must have knowledge to maintain the daily log sheet as per proforma for DG Set. Rate qouted includes supply of necessary by log sheets as per profarma given by Engg-in-charge. (iv) The Contractor/Operator must ensure the cleanliness in and around the surrounding of installation complete, The amount of Rs. 500/- for each installation will be recovered for Non-cleaning of installation etc. (v) Generator is to be operated during power failure from supply agency( TNEB) or as and when required by user/Department.
Notes for srl item No. 1 to 5 (Contd/....) (vi). The tradesmen/Operator employed by the contractor must wear the uniform with name plate with name of contractor, under whom he is working. The amount of Rs. 1000/- for each installation per month will be recovered in case of Non-wearing the uniform with name plate. (vii) Common Mobile phone with sim and without camera, Torch light, rain coat and gum boot to be provided to the duty Operator by the contractor in all the locations. viii) Responsibility of contractor to provide reliver and No additional cost shall be claimed by the contractor. The rate quoted deemed to include the pay and allowences of the reliver.Contractor must make payments to the employed personnel through AADHAR linked bank account only. Details of accounts with name shall be submitted along with the RAR Claims. (ix) Insurance cover for the Employed people is must and it is the responsibility of the contractor. Documentary evidence shall be submitted by the contractor to the department. (x) Cleaning of the DG set plant room and surrounding area of DG Set installation area from its perimeter upto 10 RM including removal of the debris away from the installations including repairs/replacement of internal fittings & fixtures through out the contract period (From Commencement to Completion of the work). (xi) If penalty imposed for low power factor by TNEB for WTS location shall be recovered from the contractor during RAR payment.It is the responsibility of the Contractor to maintain Power Factor above 0.90
Periodical maintenance of DG set as per manufacturer recommendation of the following DG sets (i) to (xxvii) installed at various locations and various capacity complete all as specified and as directed . (i) DG set 500 KVA installed at 4-IN-HANGAR (PEB HANGAR) Substation -K, Make:KOEL- Model : KV-10 (SL.NO. DVO104571420010, Set to work-11/2015) (ii) DG set 500 KVA installed at 4-IN-HANGAR (PEB HANGAR) Substation -K, Make:KOEL- Model : KV-10 ( SL.NO. DVO1045/1420014, Set to work-11/2015) (iii) DG set 320KVA installed at ATC Substation - E, Make: Kirloskar Green - Model: D8 (S.L.NO. 8101/1620180 Set to work - 06 FEB 2017) (iv) DG set 320KVA installed at ATC Substation - E, Make: Kirloskar Green- Model :D8 (S.L.NO. 8101/1620178 Set to work-06 FEB 2017) (v) DG set 250 KVA installed at P8I Maint Hanger, Make: Kirloskar cummins- Model: QLS9-G156 (SL.NO. 84501884, Set to work-07/2016) (vi) DG set 250 KVA installed at LRMR Substation - F, Make: Kirloskar cummins- Model : KT -1150 G ( SM.No. 149597, Set to work-07/1992)
Srl item No. 6 (Contd/....) (vii)DG set 250 KVA installed at LRMR Substation - F, Make: Kirloskar cummins- Model NTA 855G ( SM.No. 149598, Set to work-07/1992) (viii)DG set 200KVA installed at ATC Substation E, Make: Kirloskar cummins- Model NTA 743-G (SM.No. 149596, Set to work-07/1992) (ix) DG set 200 KVA installed at Magzine, Make: Kirloskar green (SM.No. NA Set to work-12/2013) (x) DG set 160KVA installed at Thirmalpur pump House, Make:Ruston 'V' type engine (SM.No. 149594, Set to work-07/1992) (xi)DG set 100 KVA installed at Wireless Transmission at Poigaipakkam, Make: Ashok leyland Model ALG 680 (SM.No. 149642 Set to work-01/1993) (xii) DG set 100 KVA located near watch tower No.7, (Engine Sl.No.4H-7906/ 1721952, set to work-04/2018) (xiii) DG set 100 KVA located near Main guard Room, (Engine Sl.No.4H-7906/ 1721946, set to work-04/2018) (xiv) DG set 82.5 KVA installed at Main pump house, Make: Kirloskar Oil engines Model - ATV RB-66 (SM.No. 149592, Set to work-07/1992) (xv) DG set 82.5 KVA located near STP 'A', Make: Kirloskar (Engine Sl.No.4H-8905/ 1721430, set to work-04/2018) (xvi) DG set 82.5 KVA installed near STP 'B', Make:Kirloskar (Enginre Sl.No.4H-7906/ 1721946, set to work-04/2018) (xvii) DG set 62.5 KVA installed at Thiruparkadal pump hosue, Make: Ashok leyland (SM.No. 149594, Set to work-07/1992) (xviii) DG set 62.5 KVA installed at Sub station 'I', Sick Bay, Make: Kirloskar cummins Model - NTA -743 (SM.No. 149601Set to work-07/1992) (xix)DG set 62.5KVA installed at NORA 3rd gate, Make: KirloskarOil engines, Model RV-66 (MES.No. MES/825/6001/DG/05, Set to work-9/2005) (xx) DG set 62.5KVA installed at Authur gate, Make: KirloskarOil engines, Model - RV -66 (MES.No. MES/825/6002/DG/05, Set to work-9/05)
Srl item No. 6 (Contd/....) (xxi) DG set 62.5 KVA located near LRMR sub station, Make: Kirloskar (Engine Sl.No.T-4-8907/1723723) sub station, set to work-04/2018) (xxii) DG set 62.5 KVA located near watch tower No.16, Make:Kirloskar (Engine Sl.No.T-4-8907/1723672,set to work-04/2018) (xxiii) DG set 15 KVA installed at Pump House, Make: Kirloskar Oil engines, (SM.No. 149645, Set to work-06/1992)
Srl item No. 6 (Contd/....) (xxiv) DG set 400 KVA installed at Magzine, Make: Kirloskar green (SM.No. NA ) (xxv) DG set 62.5 KVA installed at Magzine, Make: Kirloskar green (SM.No. NA ) (xxvi) DG set 400 KVA installed at New Magzine, Make: Kirloskar green (SM.No. NA ) (xxvii) DG set 500 KVA installed at New Magzine, Make: Kirloskar green (SM.No. NA )
Periodical maintenance of DG set as per manufacturer recommendation of the following DG sets (i) to (xvii) installed at various locations and various capacity complete all as specified and as directed . (i) DG set 100 KVA installed at ASR, Make: Kirloskar Oil engines RB-66 (SM.No. SM-162409 Set to work-02/1999) (ii) DG set 160 KVA installed at Substation C, Make: Kirloskar cummins Model NTA 743 G (SM.No. 149593, Set to work-07/1992) (iii) DG set 12.5 KVA installed at DVOR/DME building, Make: Kirloskar Oil engines, (SM.No.199895, Set to work-10/1995) (iv) DG set 10 KVA installed at WTS Perimeter lights at Poigaipakkam, Make: Kirloskar Oil engines, (SM.No. 149642, Set to work-09/2005) (v) DG set 6 KW installed at Main guard room building, Make: Kirloskar Oil engines, (SM.No. 199898, Set to work-04/1998) (vi) DG set 4 KW installed at Sub guard room building, Make: Kirloskar Oil engines, (SM.No. 199897, Set to work-04/1998) (vii) Portable genset 500 watts kept with BLD, Make: Shriram Honda Petrol start kerosene running (SM.No.199899, Set to work-04/1998) (viii) Portable genset 500 watts kept with BLD, Make: Shriram Honda Petrol start kerosene running (SM.No. 199891, Set to work-04/1998) (ix) IC Engine Make: Kirloskar Oil Engines installed at BSF Hanger (Fire Fighting) Bearing S F69623 1300043 Date of installation 06/2013 (x) IC Engine 50 BHP installed at P8I maint hanger, Make : Kirloskar Oil Engines, Ser. No. 3H-2121-22/1620045 (xi) IC Engine 50 BHP installed at PEB hanger (4-in hanger), Make : Kirloskar Oil Engines, Ser. No. 1622505072164
Srl item No. 7 (Contd/....) (xii) IC Engine 8 BHP installed at Magzine fire fighting pump house Make : Kirloskar Oil Engines (xiii) IC Engine 8 BHP installed at Magzine complex Make : Kirloskar Oil Engines (xiv) DG set 21.5 KVA Trolley mounted Genset, Make: KirloskarOil engines Model - RV-22 (SM.No. 142165 Set to work-04/1989) (xv) DG set 15 KVA installed at Glide path, Make: KirloskarOil engines Model - TV -2 (SM.No. 199896 Set to work-10/1995) (xvi) DG set 82.5 KVA installed at PAR Building, Make:Ashok leyland Model - ALV (SM.No. 151191 Set to work-01/1993) Note: Item No. 6 and 7 (a) Checking the fanbelt and adjusting tension. (b) Checking the fuel and oil filter ascertaining its condition. (c) Checking the Air filter and cleaning the Air filter. (d) Checking of FIP performance and oil level. (e) Checking the tappet clearance and maintaining the valve distance. (f) Checking the fuel pump timing and adjusting if required. (g) Tightening the base bolt and nuts and mounting bolts and nuts. (h) Checking the coupling bolts and adjustment checking the self starter and dynamo. (j) Checking the battery distilled water level and topping up to the required level. (k) Checking the loose connections if any in the panel board and tightening the same. (l) Checking the anti vibration mounting adjusting the bolt. (m) Checking the radiator and radiator hose and arresting small leaks. (n) Service engineer report shall be submitted for every check about the performance and maintenance of DG sets. (o) Highly skilled labours and tools for maintenance/ checks repairs /replacement is deemed to be included in the rate quoated by the contractor. (p) Coolant, distilled water shall be measured under relevant items (q) Engine Oil shall be measured under relevant items (r) Replacement of fuel /Oil/ Air filter shall be measured under relevant items.
Srl item No. 7 (Contd/....) (s) Replacement of spares shall be measured under relevant items. (t) The tradesmen employed must wear the uniform with name plate with name of contractor, under whom he is working. The amount of Rs.1000/- will be recovered in case of Non-wearing the uniform with name plate. (u) Insurance cover for the Employed people is must and sole responsibility of the contractor. Documentary evidence shall be submitted by the contractor to the department.
Srl item No. 7 (Contd/....) (v) The amount of Rs. 500/- for each installation will be recovered for Non-greasing of water pump, alternator bearings cleaning of DG set and Non-replacement of fanbelt, radiator hose, diesel pipe and spare parts DG sets etc., (w) Mechanic, Supervisor and Maintenance Engineer must be skilled and must have knowledge of maintenance of DG sets and attending minor and major fault when it arise.
Disconecting the existing battery of capacity 12V, 92/100 AH from the DG set, taking it to battery workshop, draining out the complete unserviceable sulphuric acid from the battery, filling up with new sulphuric acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to DG set, start the engine for satisfactory function complete all as specified and as directed .
All as per item No.08 here-in-before but 12V, 180AH.
Material and labour for replacing the old unserviceable battery lead with copper terminals approximately 2m length including applying jelly over the battery pole and terminals complete all as specified and as directed .
Supply and fix free maintenance battery against BER wet type battery 12V 100Ah initial charged with guarantee complete all as specified and as directed . Make: EXIDE EXPRESS / KIRLOSKAR / AMARON / AMAR RAJA
Supply and fix free maintenance battery against BER wet type Battery 12V 180Ah initial charged with guarantee complete all as specified and as directed . Make: EXIDE XPRESS/ KIRLOSKAR/ AMARON/ AMAR RAJA
Material and labour for replacing the worn out carbon brushes slipring type in alternator of the following capacity DG set including all necessary connected works complete all as specified and as directed .
4/6 KW Capacity
7.5 to 15 KVA Capacity
21.5/40 KVA Capacity
62.5 to160 KVA Capacity
Disconnecting, removing and dismantling radiator assembly from the following capacity DG sets and descaling the radiator throughly with CTC solution/ any other chemical solvent agent as approved by the Engineer-in-charge, stopping of leakage at place to copper cores and tubes by brazing scrapping the existing oil paint, dusting and painting the radiator with enamelled paint etc., re-installing and commissioning complete all as specified and as directed .
7.5 to 30 KVA capacity genset
62.5/82.5/100 KVA capacity genset
160/200 KVA capacity genset
250/320/500KVA capacity genset
Taking down the existing defective self starter from genset 12V capacity installed at various installation and replacement of work out spares like bendex drive, carbon brush, solinoid coil, armature including rewinding starter, refixing in same position and testing complete all as specified and as directed .
All as per item No.15 here-in-before but 24V.
Draining out the existing diesel from the tank from the following capacity DG set, kept aside for repouring, taking down the complete fuel tank of any capacity from its position after disconnecting all the fuel lines, carryout cleaning work with solutions, removing the dust and foreign materials from the tank, drying the tank, blow with air painting and carry out recaliberation of diesel tank to the specified level including replacement of PVC level pipe, refix the tank in its original position, connecting all the removed fuel connections, refilling the kept diesel back to the tank carefully, remove air from the fuel connections, start the engine and test for satisfactory function complete all as specified and as directed .
4/6 KW capacity
7.5/10/12.5/15 KVA capacity
30/40/62.5 KVA capacity
82.5/100 KVA capacity
160/200/250 KVA capacity
Meterial and labour for disconnecting electrical and mechanical connections of the following capacity alternator, 415 volts 50 HZ removing from foundations/ diesel engine coupling and transporting private work shop, dismantling the alternator in parts and carrying out servicing ,varnishing and applying the bactol on the excitor coils/ winding with super varnish, heating the windings at appropriate tempeature to achieve required insulation resistance without damaging the other parts, replacement of driving and non driving end bearings, cleaning, greasing, reassembling/ installing/ connecting and testing with megger for insulation resistance etc., complete all as specified and as directed .
4/6 KW capacity
7.5/10/12.5/15 KVA capacity
30/40/62.5 KVA capacity
82.5/100 KVA capacity
160/200/250 KVA capacity
Material and labour for disconnecting electrical and mechanical connections of the following capacity altrernator, 415V, 50 HZ removing from foundation/ diesel engine coupling and transporting private work shop, dismantling the alternator in parts and removing the burn out copper winding coil carefully, cleaning slots and replacing the insulation paper and winding 'F' class copper conductor winding wire of existing size/ shape, glass sleeves of connecting leads, binding/ tightening loose coils with binding cloths, varnishing and applying the bactol on the excitor coil/ winding with supper varnish, heating the windings at appropriate tempeature to achive required insulation resistance with out damaging the other parts, replacement of driving and non-driving end bearings, cleaning, greasing, reassembling/ installing/ connecting and testing with megger for insualtion resistance etc., complete all as specified and as directed .
7.5/10/12.5/15 KVA capacity
30/40/62.5 KVA capacity
82.5/100 KVA capacity
160/200/250 KVA capacity
Matertial and labour for disconnecting electrical and mechanical connections of the following capacity alternator, 415V, 50 Hz removing excitor coil from alternator, transporting private work shop dismatling, removing the burt out winding coil care fully, cleaning the slots and replacing the insulation paper and winding the 'F' Class insulation copper winding wire of existing size/ shape/ glass sleeves of connecting leads, binding/ tighting loose coils with binding cloths, varnishing and applying the bactol on the excitor coil, varnishing and applying the bactol on the excitor coil/ winding with supper varnish, heating the windings at appropriate tempeature to achive required insulation resistance with out damaging the other parts including replacement of positive and negative doides, greasing, reassembling/ installing/ connecting and testing with megger for insualtion resistance etc., complete all as specified and as directed .
4/6 KW capacity
7.5/10/12.5/15 KVA capacity
62.5/82.5 KVA capacity
100 / 160 KVA capacity
200/250 /320/500 KVA capacity
Servicing to AMF panels cleaning with blower, cleaning with CTC, replacement of damaged lugs, replacement of deteriorated copper wiring, check the power contactors, rectifying of loose connections, removing contactors and cleaning the points, refixing it in its original position complete all as specified and as directed .
Material and labour for replacing the existing damaged/ bulged radiator flexible rubber hose for the following capacity DG sets installed at various installation and replaced with new radiator flexible hose with circular hose clips complete all as specified and as directed.
7.5/10/12.5/15 KVA capacity
30/40/62.5 KVA capacity
82.5/100 KVA capacity
160 to 500 KVA capacity
Supply and fix in replacement of the following spares during 'B' check complete all as specified and as directed .
Oil filter capacity 1/2 litre with 'O' ring
Oil filter capacity 1 litre with 'O' ring
Diesel filter capacity 1/2 litre with'O' ring (Pre & Micro)
Diesel filter capacity 1 litre with 'O' ring (Pre & Micro)
Sump packing from the DG set capacity 12.5/15/21.5/40 KVA
Sump packing from the DG set capacity 62.5/82.5/100 KVA
Sump packing from the DG set capacity 160/200/250/320 KVA
Air filter suitable for 7.5/10 KVA capacity
Rocker cover packing from the DG set capacity 12.5/15/21.5/40 KVA
Rocker cover packing from the DG set capacity 62.5/82.5/100 KVA
Rocker cover packing from the DG set capacity 160/200/250 KVA
Engine Oil 20W-40. Make : BP/Indian Oil/HP
Oil filter suitable for 62.5/82.5/100 KVA capacity genset as per the existing make.
Fuel filter suitable for 62.5/82.5/100 KVA capacity genset as per the existing make.
Oil filter suitable for Kirloskar cummins engines 160 to 500 KVA capacity genset as per the existing make.
Fuel filter suitable for kirloskar cummins engines 160 to 500 KVA capacity genset as per the existing make.
Self starter solinoid switch 12V capacity.
Self starter solinoid switch 24 V capacity.
Radiator coolant
Distilled water
Electrolite
Taking down the existing worn out fan belt (V Belt) for the following capacity of DG set installed at various installation and replaced with new fan belt complete all as specified and as directed .
7.5 to 30 KVA
40 to 82.5 KVA
82.5 to 100 KVA
160 to 200 KVA
250 to 500 KVA
Taking down the existing unserviceable water pump assembly for the following capacity DG sets installed at various installation and replaced with new water pump assembly complete all as specified and as directed .
40 to 62.5 KVA
82.5 to 100 KVA
160 to 200 KVA
250 to 500 KVA
Taking down the existing defective radiator cap from the radiator and replaced new radiator cap complete all as specified and as directed
Taking down the existing unserviceable bridge rectifier from the panel and replaced with new bridge rectifier complete all as specified and as directed
Taking down the existing unserviceable relay from the AMF panel and replaced with new relay complete all as specified and as directed
Taking down the existing unserviceable power contactor from the panel and replaced with new Contactor complete for the folowing capacity all as specified and as directed
3 phase power contactor, 440 volts, 50Hz, 230 Amps
3 phase power contactor, 440 volts, 50Hz, 160 Amps
Taking down the existing unserviceable on load change over switch of capacity 4 pole, 440 Volts, 50Hz, 200 Amps from the panel and replace with new ON LOAD Change Over Switch complete all as specified and as directed
Material and labour for removing and replacing defective AVR from alternator upto 100 KVA DG sets complete all as specified and as directed . Make: Kirloskar/ Krishna
All as per item No.31 here-in-before but alternator capacity 160 to 500 KVA Capacity. Make : kirloskar/ Krishna
Taking down the existing defective oil pressure gauge from the panel and replaced with new oil pressure gauge along with metal flexible pipe complete all as specified and as directed . Make: AE/ MECO
Taking down the existing defective oil temperature gauge from the panel and replaced with oil temperature gauge along with connected links complete all as specified and as directed . Make: AE/ MECO
Taking down the existing defective injector and fuel injection pump (FIP) for the following capacity DG set installed at various installation and replacement of work out spares like delivery valves, nozzles, bearings, fly weight, packing kit, and copper washer kit and recalibration of FIP and refixing in same position and testing of full load checking of pressure complete all as specified and as directed .
7.5 to 10 KVA
12.5 to 15 KVA
62.5 to 100 KVA
160 to 500 KVA
Taking down the existing defective DC ammeter and volt meter from the panel and replaced with new combined DC ammeter and Volt meter including necessary wiring and wiring material complete all as specified and as directed .
Taking down the existing turbo charger unit from the following capacity engine, Transporting to private work shop. Dismantling opening including replacement of worn out bearing, bushes, fanblade, gaskets, seal etc., and reassembling testing/ connecting complete all as specified and as directed .
62.5 to 82.5 KVA capacity
100 KVA to 160 KVA capacity
200 to 500KVA capacity
Taking down the existing defective Air Filter inner and Outer replaced with new Air Filter inner and Outer for the following capacity Genset including replacement of connector etc., complete all as specified and as directed .
160 KVA capacity
200 KVA capacity
250 to 500 KVA capacity
Taking down the existing defective water temperature gauge from the panel and replaced with water temperature gauge along with connected links complete all as specified and as directed .
Taking down the existing defective/ rusted radiator copper core from the DG set and replaced with new copper core for the following capacity diesel generating set complete all as specified and as directed .
7.5 to 10 KVA capacity
30 to 62.5 KVA capacity
82.5 to 200 KVA capacity
Material and labour for scraping down the old faded existing paint from the following capacity DG Set of making the surface smooth by filling up the uneven surfaces with putty and scraping with emery sheet, applying two coats of synthetic enamel paint over one coat of red oxide primer, painting the details of panel over the panel complete all as specified and as directed .
4/6 KW capacity
7.5/10/12.5/15 KVA capacity
30/40/62.5 KVA capacity
82.5/100 KVA capacity
160/200/250 KVA capacity
Taking down the existing Over load relay and replaced with new one suitable for the following capacity including replacement of connector etc., complete all as specified and as directed .
Suitable for upto 7.5 HP/15 Amps
Suitable for upto 15 HP/27 Amps
Suitable for upto 25 HP/34 Amps
SIVA ENTERPRISES
C SRINIVASAN
BALA BUILDERS
SUSII CONSTRUCTIONS
N SRINIVASAN
VKR ENTERPRISES
Banyan Engineers and Contractors
HRML CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .