Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹14.5 L+₹1.1 L (8.47%)Rejected-Finance | L2 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 3 | L3₹14.7 L+₹1.3 L (9.94%)Rejected-Finance | L3 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 4 | L4₹15.3 L+₹2.0 L (14.7%)Rejected-Finance KHAWASNIWAS NEAR POLICE QTRDEORALI GANGTOK SIKKIM | L4 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 5 | L5₹16.4 L+₹3.0 L (22.7%)Rejected-Finance | L5 | Rejected-Finance HIGHER THEN L1 BIDDER |
Tender Value
₹13.3 L
EMD Value
₹27,000
Closing Date
22 Feb 2025, 6:00 pmClosed
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
REPAIR / MAINT OF VOLTAGE STABILIZER, APFC PANEL, AMF PANEL AND MISC WORKS UNDER AGE(I) DARJEELING. (2nd Call)
2024_MES_690661_2
CWE/136-WE/95 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Darjeeling
Class E, Category b(I)
8 documents required · 8 mandatory
₹500
AGE(I) Darjeeling
₹27,000
27 Feb 2025
8 Feb 2025
24 Feb 2025
8 Feb 2025
22 Feb 2025
16 Feb 2025
8 Feb 2025 - 11 Feb 2025
Amount
Disconnecting input and output supply from voltage stabilizer any type oil /air cooled and dismantling the same for repair checking/testing all component complete repairing for efficient functioning checking / tightening of all connections resetting / recalibration of all PCB's, servo motors, voltmeter, cleaning of tappng, joints of dimmer stat including replacement of minor carbon brushes button and other minor parts etc. complete all specified and directed for following capacity of stabilizer:-
Voltage stabilizer of capacity 75 KVA capacity
Voltage stabilizer of capacity 100 KVA capacity
Voltage stabilizer of capacity 400 KVA capacity
Supply only servo motor 10 kg torque of make of existing motor
Supply only servo motor 20 Kg torque of make of existing motor
Supply only servo motor 40 Kg torque of make of existing motor
Supply only dimmerstate for 75 KVA unbalanced servo stabilizer
Supply only dimmerstate for 100 KVA unbalanced servo stabilizer
Supply only PCB control Cards for Servo voltage stabilizer upto 100 KVA
Supply only PCB control Cards for Servo voltage stabilizer 400 KVA
Supply only Trigger transformer for 100 KVA for balanced type voltage stabilizer
Supply only Trigger transformer for 400 KVA for balanced type voltage stabilizer
Supply only Push button
Supply only auto manual switch
Supply only rotary switch for RYB phases
Supply only Carbon bush
Supply only PCB holder for balanced type voltage stabilizer upto 100 KVA
Supply only PCB holder for balanced type voltage stabilizer for 400KVA
Material & Labour for on line dehydration / filteration of Servo Voltage Stabilizer oil including filteration using automatic centrifuging machine minimunm three cycles to achieve dielectric strength 40 to 60 KV breaking capacity at 2.5mm gap by absorbing and abolishing all aludge particles as per BS-66-1960 including topping up with new transformer oil as required complete all as specified and as directed. Note:- (i) Centrifuging Machine with all T&P testing machine of oil required for dehydration shall be arrange by contractor (ii) Oil required for topping up the stablizer wil be measured & paid separately as supply only under respective items of this Schedule (BoQ)
Supply and filling/topping up transformer oil low viscocity, dielectric strength 35 to 40 KV breaking voltage for topping up servo voltage duly centrifuging including filter action by using automatic centrifuging machine to achieve min 35 to 40 KV breaking capacity at 4 mm gap by absorbing and adolishibg all sludge particles for use as per BS-B-66-1983 complete all as specified and directed.
Dismantling of the complete APFC of 125/100 KVAR 415 Volts from its position, opening for repair, preventive maintenance, servicing, including wiring, replacement of worn parts to make it fully functional, reassembling after repair, installation to its original position, connection with input/output supply, testing to it's full load capacity complete all as specified and directed. Notes:- (a) Spares/ parts except minor repairs required for replacement shall be measured and paid separately (b) Necessary wiring with 1.5 Sqmm Single Core FRLSH included in the above cost.
Supply only 05 KVAR capacitor double metalised (Extra low loss) suitable for APFC panel, ccomplete all as specified and directed. Make : L&T/Schnider/ABB
Supply only 10 KVAR capacitor double metalised (Extra low loss) suitable for APFC panel, complete all as specified and as directed. Make : L&T/Schnider/ABB
Supply only 15 KVAR capacitor double metalised (Extra low loss) suitable for APFC panel, complete all as specified and as directed. Make : L&T/SIEMENS(EPCOS)/ BCH ELECTRIC/ SCHINDER/ NEPTUNE SYSTEMS PVT LTD (BRAND NEPTUNE/ DUCATI)
Supply only 20 KVAR capacitor double metalised (Extra low loss) suitable for APFC panel, complete all as specified and as directed. Make : L&T/SIEMENS(EPCOS)/ BCH ELECTRIC/ SCHINDER/ NEPTUNE SYSTEMS PVT LTD (BRAND NEPTUNE/ DUCATI)
Supply and fixing in repair capacitor contactors for 20 kVAr capacitor, 415 Volts, complete all as specified and directed. Make : L&T (MO C20)/ SIEMENS(EPCOS)/ BCH ELECTRIC/ SCHINDER/ NEPTUNE SYSTEMS PVT LTD (BRAND NEPTUNE/ DUCATI)
Supply and fixing in repair capacitor contactors for 15 kVAr capacitor, 415 Volts, complete all as specified and directed. Make : L&T (MO C15)/ SIEMENS(EPCOS)/ BCH ELECTRIC/ SCHINDER/ NEPTUNE SYSTEMS PVT LTD (BRAND NEPTUNE/ DUCATI)
Supply and fixing in repair capacitor contactors for 10 kVAr capacitor, 415 Volts, complete all as specified and directed. Make : L&T (MO C10)/ SIEMENS(EPCOS)/ BCH ELECTRIC/ SCHINDER/ NEPTUNE SYSTEMS PVT LTD (BRAND NEPTUNE/ DUCATI)
Supply and fixing in repair capacitor contactors for 5 kVAr capacitor, 415 Volts all as specified and as directed by the Engineer-in-charge. Make : L&T (MO C5)/ SIEMENS(EPCOS)/ BCH ELECTRIC/ SCHINDER/ NEPTUNE SYSTEMS PVT LTD (BRAND NEPTUNE/ DUCATI)
Supply and fixing in repair control relay (auxiliary contractor), 415 Volts, complete all as specified and directed. Make : L&T (MX0-22E4P)/ SIEMENS/ SCHINDER/ ABB
M &L for complete checking of AMF panel , finding the fault servicing complete including replacement of unserviceable spares and testing complete for manual and auto operation all as specified and directed. Note: Supply only new items required for repalcement shall be measured and paid sepreately under respective items of this schedule (BoQ).
Supply only single phase preventer relay, all as specified and directed.
Supply only Thermal over load relay MN2 Type 1.4 - 2.3 Amps, all as specified and directed.
Supply only 3 Pole power contactor Type ML 100 A, 415 V, ML 4, all as specified and directed.
Supply only 3 Pole power contactor Type ML 125 A, 415 V, ML 6, all as specified and directed.
Supply and fixing in repair Perforated type cable tray of size 100 mm width and 50 mm height 16 SWG with Cover for protection of UG Cable of any size fixed to wall /ceiling with fitting accessories such as nuts, bolts, crosses and brackets etc., complete all as specified and directed.
Supply and fixing in repair Perforated type cable tray of size 150 mm width and 50mm height 16 SWG with Cover for protection of UG Cable of any size fixed to wall / ceiling with fitting accessories such as nuts, bolts, crosses and brackets etc., complete all as specifeid and directed.
Supply and fixing in repair Perforated type cable tray of size 200 mm width and 50mm height 16 SWG with Cover for protection of UG Cable of any size fixed to wall /ceiling with fitting accessories such as nuts, bolts, crosses and brackets etc., complete all as specifeid and directed.
Supply and Fix in repairs MCCB FP 63 Amps 415 Volts 25KA fixing in LT panel, complete with all accessories, including taking down of old unserviceable MCCB switch and reconnecting the cables with proper proper lugs complete , all as specified and directed. Conforming to IS Cat part no 4200 53 of Legrand or equivalent model from Siemens/Schneider/Lauritz Knudsen/ABB
Supply and Fix in repairs MCCB FP 100 Amps 415 Volts 25KA fixing in LT panel, complete with all accessories, including taking down of old Unsv MCCB switch and reconnecting the cables with proper proper lugs complete all as specified and directed by Engineer in Charge. Conforming to IS Cat part no 420055 of Legrand or equivalent model from Siemens/Schneider/Lauritz Knudsen/ABB
Supply and Fix in repairs MCCB FP 125 Amps 415 Volts 25KA fixing in LT panel, complete with all accessories, including taking down of old Unsv MCCB switch and reconnecting the cables with proper proper lugs complete , all as specified and directed. Conforming to IS Cat part no 420056 of Legrand or equivalent model from Siemens/Schneider/Lauritz Knudsen/ABB
Supply and Fix in repairs MCCB FP 200 Amps 415 Volts 36 KA DPX3 250 Thermal magnetic protection fixing in LT panel, complete with all accessories, including taking down of old Unsv MCCB switch and reconnecting the cables with proper proper lugs complete , all as specified and directed. Conforming to IS Cat part no 4202 48 of Legrand or Equivalent from Siemens/Schneider
Supply and Fix in repairs MCCB FP 250 Amps 415 Volts 36 KA DPX3 250 Thermal magnetic protection fixing in LT panel, complete with all accessories, including taking down of old Unsv MCCB switch and reconnecting the cables with proper proper lugs complete, all as specified and directed. Conforming to IS Cat part no 4202 49 of Legrand or Equivalent from Siemens/Schneider
Supply and Fix in repairs MCCB FP 400 Amps 415 Volts 36 KA DPX3 630 Thermal magnetic protection fixing in LT panel, complete with all accessories, including taking down of old Unsv MCCB switch and reconnecting the cables with proper proper lugs complete, all as specified and directed. Conforming to IS Cat part no 4220 07 of Legrand or Equivalent from Siemens/Schneider
Supply & fix in Replacement street light fitting LED type 110 watts with Pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and including driver unit etc and taking down old unsv any size/watt of security light all as directed by Engineer in charge all conforming to Cat No - ENDURASUNBEAMSL110WLED757SASYTOPC of Havells or equivalent model from Crompton/Surya/Philips
Supply & Fix in replacement LED Flood light fitting 120 Watt JETA ADORN energy saving and environmental friendly long life pressure die-cast aluminium housing flood light with PC diffused lens enclouser over LED for glare free light and taking down old unsv any size/watt of flood light , all as specified and directed conforming to Cat No JETAADORNFLS120WLED757SSYMTOTG of Havells or equivalent model from Crompton/Surya/Philips
M&L for preparing old painted surfaces by scraping and removing old paints, rust, etc. from Steel Tubular Poles (above the Planting Depth and PCC Copings of 9.0/11 Metre length Pole) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying one Coat of alternate Yellow & Black Strips Painting (4 No. Each Strip 300 mm wide) and remaining portion of Pole and Cross Arms, Cable Protection Pipe, Brackets, etc. treated with One Coat of Aluminium Paint, including writing of pole numbers with black synthetic enamel paint, complete all as specified and as directed.
Material and Labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Pt I including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, lugs, complete in all respect, GI earth strip protected by 40 mm bore (light grade) galvanized iron pipe and other end connected with main switch board or earthing test point as directed including proper lugs, including disposal of soil to a distance not exceeding 50 mtr and necessary testing on completion complete all as specified and as directed.
Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and general condition of contracts before entry / quoting the rates. Note 2:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
SANJAY KAUSHIK (BID ID -3244451)
TSHERING WANGYAL BHUTIA (BID ID -3243745)
M/S S. S CHETTRI AND SONS (BID ID -3243374)
HIRA SINGH (BID ID -3246198)
GEETA CONSTRUCTION (BID ID -3244396)
Janata Enterprises (BID ID -3246121)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .