| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.1 LAccepted-AOC | L1 | Accepted-AOC 1ST LOWEST | |
| 2 | L2₹48.7 L+₹1.8 L (3.90%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹48.7 L+₹1.8 L (3.91%)Rejected-Finance | L3 | Rejected-Finance 3RD LOWEST | |
| 4 | L4₹49.0 L+₹2.2 L (4.60%)Rejected-Finance | L4 | Rejected-Finance 4TH LOWEST | |
| 5 | L5₹49.3 L+₹2.5 L (5.29%)Rejected-Finance | L5 | Rejected-Finance 5TH LOWEST |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
26 Jun 2021, 6:00 pmClosed
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR REPLACEMENT TO GALVALUME SHEET ROOF TREATMENT ETC IN CERTAIN BLDGS OF ZONE A AREA INCLUDING REPAIR REPLACEMENT OF ELECTRIC FITTINGS AND FIXTURES WIRING AT AD COLLEGE SUPPLY DEPOT ARO MES ADM REGT AND JCOs ORS MD ACCN AND OTHER CONNECTED WO
2021_MES_448221_1
8000/47/21-22/0946/E8
Open Tender
Civil Works
Item Rate
180 days
GOPALPUR ON SEA
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹90,000
Yes
9 Aug 2021
3 Jun 2021
29 Jun 2021
3 Jun 2021
26 Jun 2021
19 Jun 2021
Amount
S&F pre- painted galvalume aluminum zinc corrugated steel based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping serews complete all as specified and directed.
Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings including ridges complete all as specified and directed.
M&L for Fe 410-W (Gde E-250 quality A) Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
M&L for Fe 410-W (Gde E-250 quality A) Framed work as in doors or gates of angle or other section with gusset plates,rails,braces etc complete,drilled for fixing of steel sheeting or other covering. Doors,etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening anf fixing complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for complete all as specified & directed.
M&L for PCC 1:3:6 Type C-2 using 40 mm graded stone aggregate in foundation filling and mass concrete complete all as specified and directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamelled paint over a coat of red oxide primer area over exc 10cm in width or girth complete all as specified and directed.
M&L for preparation of new steel surfaces of any description n exc 10cm in width or girth and priming with red oxide zinc chrome and applying two coat of synthetic enamel paint complete all as specified and directed.
M&L in repair Water proofing treatment on "Non approachable / non accessible and approachable roof" surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer including taking down of existing roof treatment, properly cleaning & drying the concrete surfaces complete all as specified and directed. (i) Applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg / Sqm (ii) Applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 kg/ Sqm incl cleaning surfaces. (iii) Laying unrolled over the bitumen coated surface, polymeric water proofing membrane Hyperplas standard wt not less than 3kg /Sqm with 100 mm over laps shall be sealed by flame as per manufacturers instruction. (iv) Applying two coats of bituminous aluminium paint including preparation complete
M&L for PCC 1:1.5:3 type A-0 (Using 12.50 mm graded stone aggregate) in roof padding/kerbs/sunken slab etc complete all as specified and directed.
M&L for 10 mm thick rendering on roof surfaces/ concrete surface in CM 1:3 finishing even and smooth complete all as specified and directed.
S & F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 500 litres capacity hoisted and fixed in position including dismantling of old u/s water tank and removing to store complete all as specified and directed.
S & F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 1000 litres capacity hoisted and fixed in position including dismantling of old u/s water tank and removing to store complete all as specified and directed.
S&F ball valves for 20 mm bore of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed.
S&F ball valves for 25 mm bore of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed.
S&F in repair ball valves for 20 mm bore of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed.
S&F in repair ball valves for 25 mm bore of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed.
M&L for Disconnecting existing tanks 500 litres capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified and directed.
M&L for Disconnecting existing tanks 1000 litres capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified and directed.
S & F in repair PVC Tank cover for 500 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed.
S & F in repair PVC Tank cover for 1000 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed.
Demolition of brickwork built in cement or cement lime mortar including all quoins, arches pillar etc complete all as specified and directed.
M&L Brick work with flyash bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Demolition of RCC of any description and in any position not other wise specially provided for reinforcement cut as required to facilitate demolition complete all as specified and directed.
M&L for pre cast cement concrete 1:1.5:3, type A-1, using 20mm graded stone aggregate as in cover slabs (for manholes etc) and similar articles with plain faces, set in CM 1:4 complete all as specified and directed.
M&L for Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Taking down cement or cement lime plaster, of any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying three coat of white wash complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections including cleaning if refixing required for complete all as specified and directed.
Taking up or down 20 mm bore steel tubing and connections including cleaning if refixing required complete all as specified and directed.
Taking up or down 25 mm bore steel tubing and connections including cleaning if refixing required complete all as specified and directed.
S & F 15 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed.
S & F 20 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed.
S & F 25 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed.
Making connection of PPR distrubtion branch with PPR main of outer dia of pipe 16 to 40mm size by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
Refixing 15 mm bore old steel tubing and connections in new or old position (wall, floor, ceiling etc) complete all as specified and directed.
Refixing 20 mm bore old steel tubing and connections in new or old position (wall, floor, ceiling etc) complete all as specified and directed.
Refixing 25 mm bore old steel tubing and connections in new or old position (wall, floor, ceiling etc) complete all as specified and directed.
Taking down cement or cement lime plaster, of any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for rendering 5 mm thick in CM 1:3 on RCC ceiling surface and finished even and smooth with out using extra cement complete all as specified and directed .
M&L for applying 2mm thick Birla / JK Putty in two layers on newly plastered walls surfaces making absolutely even and smooth, rubbing with sand paper complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall or concrete surfaces and applying two coats of oil bound distemper over & including a coat of primer including, rubbing with sand paper complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying three coat of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceilings and applying three coat of white wash complete all as specified and directed.
M & L for preparation of newly plastered surfaces of wall and applying two coats of cement based paint over a coat of primer complete all as specified and directed.
M&L for applying 2mm thick Birla / JK Putty in two layers on old wall surfaces including complete removal of existing wall finish of any type with wire brush, brooming, dusting and finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, rubbing with sand paper complete all as specified and directed.
M&L for preparation of old painted surfaces of wall and applying two coats of oil bound distemper over & including a coat of primer including, rubbing with sand paper complete all as specified and directed.
M & L for preparation of old painted surfaces of wall and applying two coats of cement based paint over a coat of primer complete all as specified and directed.
M&L for preparation of old painted surfaces of wall and applying one coat of acrylic exterior weather proof emulsion paint complete all as specified and directed.
M&L for preparation of old painted surfaces of wall and applying one coat of oil bound distemper complete all as specified and directed.
M&L for preparation of old painted surfaces of wall and applying one coat of white wash complete all as specified and directed.
M&L for preparation of old painted surfaces of ceiling and applying one coat of white wash complete all as specified and directed.
M&L for preparation of old painted surfaces of wall and applying one coat of cement based paint complete all as specified and directed.
M&L for preparation of old decorated wooden painted surfaces of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old decorated Steel painted surfaces of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Taking down carefully old UNSV aluminium point wiring with wooden batten /concealed and all accessories of(light, fan, socket or power) such as switches socket ceiling rose, fan regulators, light fitting, main switches DB’s etc and making good disturbed surface complete all as specified and directed.
M&L for point wiring with cable PVC insulated but unsheathed, 1.5 Sqmm, stranded copper conductor in and including PVC conduit duly concealed continuous earthing with cable PVC insulated 1.5 Sq mm copper conductor cable for earth continuity wire and MS box including laminated top sheet cover,washer & screw complete all as specified and directed.for One light/Call bell point controlled by one, one way switch.
All as per Item No.61 above but One fan point controlled by one, one way switch.
All as per Item No.61 above but One exhaust fan point controlled by one, one way switch.
All as per Item No.61 above but One 5 Amp socket point controlled by one switch on independent board
All as per Item No.61 above but One 5 Amp socket point controlled by one switch on same board
All as per Item No.61 above but with cable PVC insulated 4.0 Sq mm in and including PVC Conduit incl continuous earthing with cable PVC insulated 2.5 Sq mm copper conductor for power socket 15Amps complete all as specified and directed.
M&L for point wiring with cable PVC insulated but unsheathed, 1.5 Sqmm, stranded copper conductor in and including PVC casing caping duly fixed on walls continuous earthing with cable PVC insulated 1.5 Sq mm copper conductor cable for earth continuity wire , MS box including laminated top sheet cover,washer & screw complete all as specified and directed. for One light point controlled by one, one way switch.
All as per Item No. 67 above but One fan point controlled by one switch.
All as per Item No. 67 above On 3 pin 5 Amps socket outlet point on independent board
All as per Item No. 67 above On 3 pin 5 Amps socket point on the same board
All as per Item No. 67 above One light point controlled by two way switches
All as per Item No. 67 above but with cable 4 sqmm including 2.5 sqmm cable as earth wire for 15/16 amp socket.
M&L for point wiring in existing conduit with PVC insulated, unsheathed, single core multistandard copper conductor cable 1.5 Sqmm, stranded copper conductor in and including PVC insulated 1.5 Sq mm copper conductor cable for earth continuity wire and MS box including laminated top sheet cover,washer & screw complete all as specified and directed. for One light point controlled by one, one way switch.
All as per Item No. 73 above but One fan point controlled by one switch.
All as per Item No. 73 above but On 3 pin 5 Amps socket outlet point on independent board
All as per Item No. 73 above but On 3 pin 5 Amps socket point on the same board
All as per Item No. 73 above but One light point controlled by two, two way switches
All as per Item No. 73 above but with cable 4 sqmm including 2.5 sqmm cable as earth wire for 15/16 amp socket.
S&F switch socket combination 2-in-1, 5 pin 5 Amp complete all as specified and directed.
S&F switch socket outlet 5 pin 5 Amp complete all as specified and directed.
S&F switch socket combination 2-in-1, 5 pin 5 and 15 Amp complete all as specified and directed.
S & F switch piano (Flush type) 5 amps, 240 Volts, single pole one way complete all as specified and directed.
S & F switch piano (Flush type) 5 amps, 240 Volts, single pole two way complete all as specified and directed.
S&F modular socket 6A , 2/3 pin combined 2 module complete all as specified and directed.
S&F modular switch6A complete all as specified and directed.
S&F modular switch 1 way 16A, 1 module complete all as specified and directed.
S&F modular socket 6A / 16A , 2/3 pin combined 2 module complete all as specified and directed.
S&F modular 6A 1 module 2 way switch complete all as specified and directed.
S & F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and directed.
S & F for Bell push modular 6 Amps single module complete all as specified and directed.
S&F modular Ceiling rose 3 termianl complete all as specified and directed.
S&F modular white cover plate with frame for module 3 incl modular metal flush box complete all as specified and directed.
All as per Item No. 92 above but for 6 module complete all as specifed and directed.
All as per Item No. 92 above but for 8 module complete all as specifed and directed.
All as per Item No. 92 above but for 12 module complete all as specifed and directed.
All as per Item No. 92 above but for 18 module complete all as specifed and directed.
S&F Bakelite Sheet cover plate of size (5x5) complete all as specified and directed.
S&F Bakelite Sheet cover plate of size (8x5) complete all as specified and directed.
S&F Bakelite Sheet cover plate of size (11x13) complete all as specified and directed.
S & F in replacement of PVC Gang box Square type for fittings complete all as specified and directed.
S & F in replacement of PVC Board box of (4x4) Size complete all as specified and directed.
S & F in replacement of PVC Board box of (6x8) Size complete all as specified and directed.
S & F in replacement of PVC Board box of (8x10) Size complete all as specified and directed.
S&F ceiling rose, bakelite three terminal complete all as specified and directed.
S & F bell ding dong electric single phase 240 Volt. complete all as specified and directed.
S & F ceiling fan regulator electronic step type socket mounting type. complete all as specified and directed.
S & F in repair LED light fitting 18/ 20 Watt T5 batten type,PVC extruded batten with decorative end caps complete with polycarbonate /glass tube 4Ft White , internally pre-wired and including connecting up with suitable twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S & F in repair of light fittings (2Ft) with wall mounted LED pattern with polycarbonate housing & integrated electronic driver of 9W cap T5(max lenght upto 600mm) complete all as specified and directed. (Note : Contractor shall submit warratny for 03 yrs)
S&F in repair LED Porch light/surface mounting downlighter type with round surface,PDC Al housing light fittings of 10 W cap 3000K incl taking down the old unsv complete all as specified and directed. (Note : must for warrenty of 3 yrs to 5 yrs)
S&F in repair recess mounting LED low forfole slim fit downlights with high lumin out put of 12 wats cap with celing cutout 160mm oval/round of ht 25mm complete prewired incl necessary electrical connections complete all as specified and directed.
S & F in repair recess mounting LED Endura slim pro plus ceiling light suitable for armstrong/grid ceiling complete capacity 36W, sIze 2'x2' including taking down the old rusted tube light fitting complete all as specified and directed.
S & F in repair recess mounting LED Endura slim pro plus ceiling light suitable for armstrong/grid ceiling complete capacity 24 W, sIze 1'x2' complete all as specified and as directed including taking down the old rusted tube light fitting complete all as specified and directed.
S & F in repair recess mounting LED Endura slim pro plus ceiling light suitable for armstrong/grid ceiling complete capacity 24 W, sIze 1'x1' including taking down the old rusted tube light fitting complete all as specified and directed.
S&F in repair Globe Decorative wall light fixture made up of Polycarbonate,suitable for LED incl LED Bulb 10W B-22 Series complete all as specified and directed.
S&F in replacement of bldg security light fitting LED type of 20 watt New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 luminaire with high power LEDs as light source and electronic driver. mounting bracket suitable to house the light fittinhg , with its Galvanised Flat Iron clamps conntected nuts bolts etc complete all as specified and directed. (Note : must for warrenty of 3 yrs to 5 yrs)
M&L for replacement of 2 Runs of cable PVC insulated but unsheathed 4.0 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 2.5 Sq mm, stranded copper conductor complete all as specified and directed.
M&L in replacement of 2 Runs of cable PVC insulated but unsheathed 1.5 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 1.0 Sq mm, stranded copper conductor complete all as specified and directed. Note :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre.
M&L in replacement of 2 Runs of cable PVC insulated but unsheathed 2.5 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 1.5 Sq mm, stranded copper conductor complete all as specified and directed. Note :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre.
M&L for replacement of 2 Runs of cable PVC insulated but unsheathed 6.0 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 4.0 Sq mm, stranded copper conductor complete all as specified and directed. Note :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre.
M&L for replacement of 2 Runs of cable PVC insulated but unsheathed 10 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 6.0 Sq mm, stranded copper conductor complete all as specified and directed. Note :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre.
S & F in replacement of 3 core 1.0 Sqmm round Sheathed copper wire complete all as specified and directed.
S & F in replacement of sheet metal enclosure vertical DBs with provision for FP MCCB frame upto 100A in 16,KA as incomer 4 way double door made complete all as specified and directed.
S & F in replacement of sheet metal enclosure double door MCB DB, SPN 12 way complete all as specified and directed.
S & F in replacement of sheet metal enclosure double door MCB DB, SPN 8 way complete all as specified and directed.
S & F in replacement of sheet metal enclosure double door MCB DB, TPN 4 way complete all as specified and directed.
S & F in replacement of MCCB 100 Amps 4 Pole 25 KA 415 Volts complete all as specified and directed.
S & F in replacement of MCCB 63 Amps 4 Pole 16 KA 415 Volts complete all as specified and directed.
S & F in replacement of of TPN 40 Amps 415Volts complete all as specified and directed.
S & F in replacement of TPN 63 Amps 415Volts complete all as specified and directed.
S & F in replacement of MCB SPN 16 TO 32 Amp 10 KA 240 Volts complete all as specified and directed.
S & F in replacement of MCB, SP 6 to 30 Amp 240 Volts rating complete all as specified and directed.
S & F in replacement of exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified and directed.
S & F in minor repairs to FTL fittings by replacing bi-pin holders, connectors , tube rods chokes of any type and capacity etc complete all as specified and directed. Note : Tube rods and chokes are measured separately
Supply only Electronic Ballast suitable for 36/40 watts FTL conventional light fittings complete all as specified and directed.
supply only Electronic Ballast suitable for 28 watts FTL conventional light fittings complete all as specified and directed.
Supply only tube rod 36/40watt for 4 feet tube light fittings complete all as specified and directed.
Supply only tube rod 28 watt for 4 feet tube light fittings complete all as specified and directed.
S&F in replacement of single pole and neutral enclosure with a two pin and earth plug socket 240 V with one MCB SP ‘C’ series rating 20 to 30 Amp complete all as specified and directed.
M&L in replacement for earthing with galvanized steel earth plate electrode 600 x 600 x 6mm thick, buried directly in ground(earth pit not less than 2.25 mtrs deep below ground level)with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers protected with & including 15 mm dia light grade GI pipe necessary excavation and earth works, charcoal and common salt filling, watering arrangement with 20 mm GI pipe light grade including PCC pit with Pre cast RCC (1:2:4) cover, GI funnel with mesh test point, testing & commissioning complete all as specified and directed.
Supply testing and commissioning AC three phase ,3x 240V ,50Hz, digital,electronic tamper proof energy meter of rating 10 to 60 Amps covered with PVC transparent cover with optical communication port incl taking down the unsv meter complete all as specified and directed.
Supply testing and commissioning AC single phase,50Hz, digital,electronic tamper proof energy meter of rating 5 to 30 Amps covered with PVC transparent cover with optical communication port incl taking down the unsv meter complete all as specified and directed.
M/s Bapujee Builders and Traders
R K Traders
ABC CONSTRUCTION COMPANY
M/s MAA BHAIRABI ENTERPRISES
HARAGOURI SUPPLIERS
Likitha Enterprises
M/S. KISHAN ENGINEERING
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .