| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC E 27 CWE WELLINGTON | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹33.0 L+₹3.5 L (11.7%)Rejected-Finance EY 04 PODA WC CHANDIGARH A I A II B I | CHANDIGARH | CHANDIGARH | 160001 | L2 | Rejected-Finance Being Not Lowest Tenderer | |
| 3 | L3₹34.4 L+₹4.8 L (16.4%)Rejected-Finance NO 12 25 26 KATHIRAVAN NAGAR MAHALINGAPURAM PO POLLACHI COIMBATORE 642 002 | COIMBATORE | TAMIL NADU | 642002 | L3 | Rejected-Finance Being Not Lowest Tenderer | |
| 4 | L4₹39.3 L+₹9.8 L (33.0%)Rejected-Finance DUDH LINE NAYAGAON VILL SHADIPUR POST SRI VIJAYA PURAM TEHSIL SOUTH ANDAMAN 744106 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744106 | L4 | Rejected-Finance Being Not Lowest Tenderer | |
| 5 | L5₹39.8 L+₹10.3 L (34.9%)Rejected-Finance | L5 | Rejected-Finance Being Not Lowest Tenderer |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
7 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Wellington, Barracks Post, The N
Garrison Engineer Wellington, Barracks Post, The Nilgiris.
PROVISION OF VEHICLE RAMP WITH HARD STANDING AND WATER WASH FACILITIES NEAR BLDG No T-28 OF 110 INFANTRY BATTALION (TA) MADRASAND CERTAIN SANCTIONED AND MINOR WORKS AT ARMY AREA COIMBATORE AND MADUKKARI UNDER GE WELLINGTON
2023_MES_580931_1
8783/E8
Open Tender
Civil Works
Item Rate
180 days
GE Wellington
As per tender document
5 documents required · 5 mandatory
₹500
GE Wellington
₹73,000
Yes
10 Apr 2023
14 Feb 2023
14 Mar 2023
14 Feb 2023
7 Mar 2023
28 Feb 2023
Amount
Dismantling of asbestos cement corrugated, semicorrugated sheeting, any gauge and thickness in roof coverings including Nainital or similar pattern roof covering complete all as specified and as directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws all as specified and directed.
Pre- painted galvalume aluminum zinc coating GI based Plain steel sheet as in ridge of 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering and on chajjas fixed with self tapping screws all as specified and directed.
Dismantling of timber scantling 40 sqcm and over in sections in any position in unframed works all as specified and directed.
Steel woork in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 all as specified and directed.
Dismantling of wall/ ceiling boards (fibre, pulp, insulation, etc) or insulation boards/ slabs/ blankets, any thickness, including cover fillets and frame work all as specified and directed.
False ceiling using GI snap grid system with roll-formed out of hot-dip galvanised steel capping (powder coated), main runner 38x24mm, cross Tee 29x24mm and wall angle 24x24mm and thickness not less than 1 mm, members suspended with Hangers 4 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long , with 4mm thick designer ceiling board of any texture (Lake & hill, Oceanic, cascade or Electra) as approved by GE, all as per Everest Ceiling grid system "Regular T-2430" or its equivalent make of "Ramco/ Charminar/ Armstrong" Note: Suspenders of GI wire 4mm dia shall be provided at 1200mm centre to centre alongwith telescopic adjustable fastening system (nut & bolt) of minimum 6mm dia.
Taking down chowkats or frames exceeding 1.5 Sqm and not exceeding 4Sqm each with shutters (without taking off shutters from the frames) all as specified and directed.
Anodised aluminium frame for partition (63mm x 38mm x 1mm size channel) with one or more rebates including 25mm x 25mm beading, joining cleat for fixing etc complete all as specified and directed.
Anodised aluminium door shutters, aluminium section weighing 0.55 Kg/m including joining cleats glazing clips, rubber neoprene packing handles 2 Nos in each door, hinges anodised aluminium snap beading screws etc complete all as specified and directed.
Prelaminated particle board, 9mm thick interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws all as specified and directed.
Plain sheet glass 4.0mm thick ordinary quality and glazing with oil putty in square exceeding 0.5 Sq.m in each pane complete all as specified and directed.
Door closer aluminium (extruded section) body hydraulically regulated designation No.3 universal type suitable for door shutters of 851 to 1000 mm in width and weight between 61 to 80 kg and fixed complete all as specified and as directed.
Second class HW plain, framed, panelled shutters 30mm thick (any No of panels) with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers supplied and fitted to chowkats all as specified and directed.
Butt hinges, 150 mm size medium weight, cold rolled mild steel, and fixed complete all as specified and directed.
150mm long aluminium anodised barrel tower bolt of extruded section all as specified and as directed.
Extruded aluminium alloy handles 150 mm size, fabricated type, anodised complete all as specified and as directed
300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
Floor door stopper of aluminium alloy body and tongue, anodized, with hard drawn steel pin fixed to door, over all length 140mm all as specified and directed.
Taking down chowkats or frames not exceeding 1.5 Sqm each with shutters (without taking off shutters from the frames) all as specified and directed.
Solid PVC door frame of size 50 mm x 47 mm made out of 5mm plain color PVC sheet reinforced with MS Square tube, fixed in opening as per specification all as specified and directed.
Factory made solid panel PVC door shutter 30 mm thick (stile) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding all as specified and directed.
Screed bed or bedding layer of cement mortar 15mm thick (1:6) for laying floor finishes all as specified and directed.
Non-skid coloured ceramic tiles 6 to 7mm thick, area of each tile exceeding 0.06 Sqm and not exceeding 0.11 Sqm in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
Backing coat / screed 10mm thick in cement mortar 1:4 on fair faces of brick / stone wall surfaces all as specified and directed.
Coloured glazed ceramic tiles 300 x 250 x 8-10mm thick as in skirting / dado set and jointed in neat cement slurry and pointed in coloured cement to match colour of the tile complete all as specified and directed.
Taking down existing drain / soil / waste / vent pipes of any description and in any position of any size all as specified and directed
110mm bore PVC (SWR) pipes single socketed, with rubber ring joints in any length, fixed to walls / laid in floors all as specified and directed.
PVC (SWR) bends any radius, 110mm bore all as specified and directed.
110mm dia PVC (SWR) junction single, (Single T) equal or unequal with access door all as specified and directed.
75mm bore PVC (SWR) pipes single socketed, with rubber ring joints in any length, fixed to walls / laid in floors all as specified and directed.
PVC (SWR) bends any radius, 75mm bore all as specified and directed.
40mm bore PVC (SWR) pipes single socketed, with rubber ring joints in any length, fixed to walls / laid in floors all as specified and directed.
Cast iron nahani trap 75mm outer dia with grating including jointing with solvent cement all as specified and directed.
PVC (SWR) gully traps 125 x 110mm, setting and jointing with solvent cement including concrete pedestal etc complete all as specified and directed.
Vitreous China, wash down water closet pan (Pedestal pattern), white (excluding flushing cistern and flush pipe) including fixed in repairs of flushing cistern complete all as specified and directed.
PVC valveless syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets of 10 litre capacity, fixed in repairs all as specified and directed.
Vitreous china wash basin, white, flat back, size 550 x 400mm including cutting for and pinning in ends of brackets but exclusicve of fixing of and waste pipe complete fixed in repairs all as specified and directed.
Pillar taps, fancy type, 15mm dia cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe all as specified and directed.
PVC connections 15mm size of length 600mm with PTMT nuts all as specified and directed.
Angular Stop valves 15mm dia bore, cast copper alloy screwed down high pressure fancy type, chromium plated screwed both ends for iron pipe or unions complete all as specified and directed.
Two in one combination of bib tap, cast copper alloy, chromium plated, fancy type screwed down screwed for iron pipe or for brass ferrule for 15mm dia of pipe complete all as specified and directed.
Health faucet (Jet Spray ) Brass CP, 15mm dia with flexible pipe 1m long and fixing nut etc complete all as specified and directed.
Tubular towel rail 20mm dia, brass chromium plated fancy type with brackets all as specified and directed.
Demolition of Brickwork, stone / boulder masonry built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc ,complete all as specified and as directed.
Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:6) all as specified and directed.
Brick work with sub class 'B' bricks, old size, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 all as specified and directed.
Rendering 15mm thick in cement mortar 1:6 on brick work or concrete surfaces , finished even and smooth without using extra cement all as specified and directed.
Rendering 15mm thick in cement mortar 1:4 on brick work or concrete surfaces , finished even and smooth without using extra cement all as specified and directed.
Taking down steel / PVC tubing and connections including cleaning etc dia up to 15mm bore all as specified and directed.
Taking down steel / PVC tubing and connections including cleaning etc dia up to 20mm bore all as specified and directed.
15mm bore unplasticised PVC pipes including fittings of pressure rating 10 Kgf/cm² laid and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Applying two coats of oil bound distemper over a coat of primer on newly plastered surfaces including preparation of surfaces complete all as specified and directed.
Applying one coat of wall care putty to cover old uneven plastered surfaces in wall / ceiling up to 1mm to cover undulations and finished even and smooth using emery paper all as specified and directed.
Preparing surfaces of wall and applying two coats of oil bound distemper including washing rubbing down and stopping of distempered and painted surfaces on old plastered wall surface complete all as specified and directed.
Preparation of old wall surfaces and applying two coats of white wash including complete removal of existing treatment complete all as specified and directed.
Preparing old plastered wall surfaces and applying two coats of cement base paint including removal of existing treatment complete all as specified and directed.
Preparing surface of wall and applying two coats of cement based paint on newly plastered wall surface complete all as specified and directed.
Preparation of new wood surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed.
Preparation of old painted wooden surfaces exceeding 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
Preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
Preparation of old steel surfaces over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
Preparation of old surface of wood and wood based materials, new or old of any description and grith not otherwise described and treated with creosote complete all as spcified and directed.
Surface dressing not exceeding 30cm deep and averaging 15cm deep and getting out in hard / dense soil all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.50M in depth; for foundation, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed.
PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundations filling and mass concrete all as specified and directed.
Pre-cast cement concrete block masnory with solid block exceeding 10cm in width and setting in mortar 1:6 type C1, 1:3:6, 20mm graded stone aggregate with compressive strength of 50 Kgs/ Sqcm as per IS 2185 (part I) complete all as specified and directed
Preparation of newly plastered surfaces of walls and applying three coats of white wash all as specified and directed.
Use and waste of form work to sides and bottom of beams with rough finished surface of concrete complete all as specified and directed.
Mild steel TMT bars 10mm dia of grade Fe-500/500D and over cut to length, bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
Mild steel TMT bars 6mm to 8mm dia of grade Fe-500/500D and over cut to length, bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
Reinforced cement concrete (nominal mix) Type B1, 1:2:4, using 20mm graded stone aggregate for beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in soft / loose soil complete all as specified and directed
Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
Hardcore of broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface all as specified and directed.
100mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base of flooring / hard standing and finished even and fair complete all as specified and directed.
Sand filing under floors or in foundations including watering and consolidation all as specified and directed.
Machine Pressed precast concrete interlocking paver block rubberised any shape and size conforming to IS- 15658 - 2006 of 60 mm thickness M-40 Grade with grey cement and no pigment complete all as specified and directed.
Plain cement concrete type B1, 1:2:4 (using 20mm graded stone aggregate) in lintel upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified and directed.
Galvanised steel tubing 15mm bore medium grade with screwed and socket joints together with all galvanised steel fittings such as sockets, elbows, bends,tees, reducers, short pieces, unions, caps, plugs etc. laid in trenches including connection, cutting, screwing, drilling etc all as specified and directed
Gun metal globe or gate valve, heavy duty conforming to IS-778 with iron wheel head screwed both ends sitable for fixing to GI pipe including dismantling taking out old unserviciable Gun metal globe or gate valve of size 25mm bore all as specified and directed
Car washer unit of capacity 5HP Kirlosker Pump set with brass water wash Gun including 10RM rubber hose and L&T DOL starter complete all as specified and directed.
Seamless calcium silicate ceiling made out of 1800 x 1200mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25mm long self drilling and tapping screw having phillips head with under head cutter at 200mm centre to centre inluding finishing the joint of face board with specially formulated jointing compound and 48mm wide fibre tape to provide seam less finish all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors , aprons etc laid, bedded and pointed in any mortar, complete all as specified and directed.
40mm thick cement concrete type B1 1:2:4 (20mm graded stone aggregate) as in sub floor, sub base, floors and pavings etc complete all as specified and directed.
Providing precast cement concrete set in cement mortar 1:6 type B1 1:2:4 using 20mm graded stone aggregate for shelves all as specified and directed.
Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations all as specified and directed.
Granite 20mm thick machine cut, as in floor bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing all as specified and directed.
Vitrified coloured ceramic tiles 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white cement slurry to match the surface complete all as specified and as directed.
Coloured ceramic tiles (350x250x7 / 450x350x7mm thick as in skirting / dado set and jointed in neat cement slurry and pointed in coloured cement to match colour of the tile complete all as specified and directed.
Brick wall cladding edge cut (2030mm x 0.075mm) all as specified and directed.
BWR ply 18mm thick with laminated finish used for rear storage cabinet, bar area door, front cabinet finishing including wall edeges all as specified and directed.
Mild steel works for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drill and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts all as specified and directed.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete including tube light fittings, switches, ceiling roses, pendants, fan regulators, sockets etc and making good to the disturbed surfaces of walls, floors, roof etc all as specified and directed.
Point wiring with multistranded copper conductor 1.5 sq mm nominal cross-sectional area single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No. in and including medium grade, PVC conduit and accessories on wall/roof/floor etc, ISI marked with mild steel/pressed steel sunken box (with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally. and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, including PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth duly One light point controlled by one switch 5 Amp one way complete all as specified and directed.
All as per item No 99 hereinbefore but one fan point controlled by one switch 5 amps and regulator all as specified and directed.
All as per item No 99 hereinbefore but one socket outlet 3 pin 5 amps on independent board all as specified and directed.
All as per item No 99 hereinbefore but for 4 Sqmm PVC insulated and PVC unsheathed copper multi stranded conductor cable and 4 Sqmm multi stranded copper conductor for earth wire for 3 pin 15 Amps power points all as specified and directed.
Modular switch one way 6A 240V AC 50 HZ SP one module all as specified and directed.
Modular socket 2/3 pin combined 6A 240V AC 50 HZ SP two module all as specified and directed.
Modular socket outlet 2/3 pin combined 6/16A 240V AC 50 HZ SP two module all as specified and directed.
Modular fan regulator 2 module all as specified and directed.
Modular white coverplate with frame 3 module all as specified and directed.
Modular white coverplate with frame 4 module all as specified and directed.
LED light fitting 1 x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specifie and directed.
LED luminaire 600mm x 600mm, 40 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holder and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specifie and directed.
2ft LED light fitting 1 x 16W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specifie and directed.
MCB DB SPN 8 way suitable for single phase 240 volts with 200 amps rated bus bar double door type suitable for mounting incoming and outgoing MCB's single / double pole including dismantling of old existing complete all as specified and directed.
MCB's SPN 32 Amps, 240 Volts all as specified and directed.
MCB's single pole 6 to 32 Amps, 240 Volts all as specified and directed.
Taking down sub main wiring of any size in any type all as specified and directed.
Taking down unserviceable main switch / DB with MCB of any type and capacity complete all as specified and directed.
Sub main wiring with two runs of single core 4 Sqmm copper conductor FRLS cable PVC insulated unsheathed multistanded 1100V grade drawn through PVC casing and capping with all accessories, fixed to wall ceiling etc including 4 Sqmm single core copper conductor FRLS cable PVC insulated, unsheathed multistranded 1100V grade as earth continuity conductor connected to common earth dolly complete all as specified and directed. Note: 2 runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as one unit length.
Sub main wiring with two runs of single core 6 Sqmm copper conductor FRLS cable PVC insulated unsheathed multistanded 1100V grade drawn through PVC casing and capping with all accessories, fixed to wall ceiling etc including 6 Sqmm single core copper conductor FRLS cable PVC insulated, unsheathed multistranded 1100V grade as earth continuity conductor connected to common earth dolly complete all as specified and directed. Note: 2 runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as one unit length.
Earthing complete with GI earth plate electrode 60x60cmx6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI earth wire 4mm dia protected by GI pipe light grade 15mm dia and connected to panel board / DB by means of bolts and nuts washers made out of GI all as shown in Electrical plate No 3 of SSR part I including necessary earth work and excavations in any type of soil, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type B1 cover slab, reinforcement with 6mm dia MS bars at 100mm dia both ways, MS hook 6mm dia MS bars etc complete all as specified and directed.
Exhaust fan, steel body AC single phase 230V of size 300m sweep with blades and frame and louvers complete all as specified and directed.
Taking down fan, ceiling cable end, dismantling blades and removing fan and blades to store complete all as specified and directed.
Hanging only ceiling fan and connecting up including provision of flexible cable from ciling rose or connector to fan complete all as specified and directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20A MCB all as specified and directed.
Well burnt bricks sub class 'B' as in protectiion of cable laid dry, flat abutting each other width wise all as speciifed and directed.
XLPE insulator armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section 6 Sqmm 4 core laied in ground / fixed in wall complete all as specified and directed.
cutting the existing road / hard standing made of concrete or premix carpet WBM soling and moorum filling including excavating for laying the cable/ pipe width 0.5 mtr and depth 0.7 Mtr all as directed and making good the road / hard using all old /new materials as required at site to match with the existing surface all as specified and directed.
GI tubing light grade 32mm dia bore for protection of cable fixed in wall or laid in trenches including taking up or down old unserviceable tubing all as specified and directed.
MCB TPN 32 Amps, 440 volts complete all as specified and directed.
MCB TPN 16 Amps, 440 volts complete all as specified and directed.
Electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, PVC connection piece etc. all as specified and directed.
Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one 20A SP MCB all as specified and directed.
Sub main wiring with two runs of PVC insulated multistranded copper conductor cable 4 sqmm with one run of 2.5sqmm as earth continuity conductor including 25mm dia PVC casing caping and taking down existing submain wiring complete all as specified and directed. Note: 2 runs of cable, one run of earth continuity conductor and one run of PVC casing caping shall be measured as one unit length.
Supply and laying of 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings intrenches / roof for solar geyser line complete all as specified and directed.
Supply and fix CPVC ball valve complete all as specified and directed.
Bib taps of cast copper alloy fancy type chromium plated screwed down, screwed for iron pipe or for brass ferrule and fixed 15mm bore, fixed in repairs all as specified and directed.
Point wiring using with multistranded copper conductor cable 1.5 sqmm nominal cross-sectional area single core PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No. in and including PVC conduit pipe and accessories on wall / roof/ floor etc, ISI marked with mild steel / pressed steel sunken box (with earth dolly) duly painted with two coats of anti corrosive paint/ aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, including PVC insulated multistranded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth duly completed for One fan point controlled by one switch 5 amps all as specified and directed.
Modular white cover plate with frame 1 module all as specified and directed.
Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed.
Cutting the wall for fixing the 250mm sweep exhaust fan and to make the surface in good condition by painting the wall with existing colour complete all as specified and directed.
Taking down the existing panel board and connected accessories all as specified and directed.
PVC insulated water proof multi stranded copper conductor cable 3 core 6 Sqmm 1100 volt grade ISI marked from LT panel to submersible pump moter set in bore well all as spcified an directed.
GI tubing light grade 40mm dia bore for protection of cable fixed in wall or laid in trenches including taking up or down old unserviceable tubing all as specified and directed.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth in soft /loose soil and taking out for laying of pipe line all as specified and directed.
Supplying and laying of CPVC pipes SDR 11 and palin CPVC SDR 11 fittings in trenches for bore of pipe 50mm dia all as specified and directed.
Supplying and laying of CPVC pipes SDR 11 and palin CPVC SDR 11 fittings in trenches for bore of pipe 40mm dia all as specified and directed.
Supplying and laying of CPVC pipes SDR 11 and palin CPVC SDR 11 fittings in trenches for bore of pipe 25mm dia all as specified and directed.
Taking up or down old PPR pipes and connections, including cleaning for refixing or removing complete for bore of pipe 50mm dia all as specified and directed.
Taking up or down old PPR pipes and connections, including cleaning for refixing or removing complete for bore of pipe 40mm dia all as specified and directed.
Taking up or down old PPR pipes and connections, including cleaning for refixing or removing complete for bore of pipe 25mm dia all as specified and directed.
25mm dia Gunmetal, globe or gate valves with iron wheel head, screwed both ends for iron pipe all as specified and directed.
40mm dia Gunmetal, globe or gate valves with iron wheel head, screwed both ends for iron pipe all as specified and directed.
50mm dia Gunmetal, globe or gate valves with iron wheel head, screwed both ends for iron pipe all as specified and directed.
K C ASSOCIATES
Rajapriyaconstruction
M/S SHAJAHAN BUILDERS
SKM CONSTRUCTION
Narendran Enterprises
M/S NS CONTRACTOR
U P ENTERPRISES
M Govindarajan
WELTRONENGINEERINGSERVICES
TECKXPERT ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .