Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1Accepted-AOC K 796 ASHIYANA LUCKNOW UTTAR PRADESH 226012 | LUCKNOW | UTTAR PRADESH | 226012 | ₹1 | L1 | Accepted-AOC L1 |
| 2 | L1₹1Accepted-AOC 238 L G F SANT NAGAR EAST OF KAILASH NEW DELHI DELHI 110065 | SOUTH EAST DELHI | DELHI | 110065 | ₹1 | L1 | Accepted-AOC L1 |
| 3 | L1₹1Accepted-AOC PLOT NO 63 UDYOG VIHAR PH IV GURUGRAM 122015 GURGAON HARYANA 122001 | GURUGRAM | HARYANA | 122015 | ₹1 | L1 | Accepted-AOC L1 |
| 4 | L1₹1Accepted-AOC 5TH FLOOR SATYANARAYAN PRASAD CO MM CENTRE DAYALDAS LANE OFF NEHRU ROAD VILE PARLE EAST MUMBAI MAHARASHTRA 400057 | MUMBAI SUBURBAN | MAHARASHTRA | 400057 | ₹1 | L1 | Accepted-AOC L1 |
| 5 | L1₹1Accepted-AOC TULIP BLOCK GITANJALI DR REGO BAGH ALTO SANTACRUZ BAMBOLIM GOA 403202 | NORTH GOA | GOA | 403202 | ₹1 | L1 | Accepted-AOC L1 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
7 Aug 2024, 11:00 amClosed
THE DY. DIRECTOR OF HEALTH SERVICES (E and S)
Central Medical Stores 141, A J C Bose Road, Kolkata 700014
RE E TENDER FOR PROCUREMENT OF SOME KITS, CHEMICALS AND REAGENTS FOR TWO YEARS FROM THE DATE OF AWARD OF CONTRACT (AOC) AND ITS EXTENSION, IF REQUIRED
2024_HFW_709891_1
HST/4T-94-2024/KITS-RT(292) /2024/304
Open Tender
Medicines
Item Wise
730 days
KOLKATA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1 L
Yes
5 Dec 2024
9 Jul 2024
7 Aug 2024
9 Jul 2024
7 Aug 2024
23 Jul 2024
HIV and Syphilis Rapid Diagnosis dual Test Kit Technical Specification of the Kit: 1. The assay should have synthetic and/or recombinant type of the following a. Multiple Treponema pallidum antigens and b. Antigens of HIV 1 (including gp41) and HIV 2 (including gp36) 2. The Kit should be able to individually detect antibodies to HIV 1 & 2 and anti-Treponema pallidum antibodies in human serum/plasma/whole blood (finger prik). 3. The assay may be based on any of the rapid test principles such as flow-through (immunoconcentration) or lateral flow (immunochromatography). 4. The assay should be able to detect all antibodies to all sub types of HIV 1 , HIV 2 & Treponema pallidum for serological diagnosis of syphilis. 5. The assay should have an in-build control for testing the validity of the test procedure. 6. Specifications: a. For HIV, the assay should have sensitivity of 100% and specificity of greater than or equal to 98%. b. For Syphilis, the assay should have sensitivity of greater than or equal to 85% and specificity of greater than or equal to 93%. 7. The kit (indigenous or imported) licensed by the competent authority defined under Drugs and Cosmetics Act at 1940 & Rule 1945 and/or Medical Device Rules 2017. 8. Imported rapid kit should have approval of the statutory authority for in-vitro diagnostics in its country of origin. 9. Total procedure time should not be more than 30 minutes. 10. The kit should have a shelf life of at least 18 months at the time of receipt by the consignee. 11. The manufacturer/ authorized agent should ensure maintenance of cold chain i.e. 2-8 degree Celsius during storage and transport of the kits. Indicator should be provided on the exterior of each kit box to track the cold chain maintenance. 12. The test kit should be packed such that there is provision to conduct single test at a time. 13. The test kit should be available in pack size of 20 test per kit (minimum pack size) to 50 test per kit (maximum pack size) . 14. Adequate literature detailing the principle, components, methodologies, validity criteria, biosafety, performance characteristics, storage conditions, limitation of assay, items required but not provided in the kit, manufacture and expiry dates and methods of disposal should be provided with each kit. 15. The kit should be supplied with sufficient amount of capillaries to deliver the required amount of specimen specified in the kit literature.
ANTI CCP ELISA KIT
Anti DSDNA-(Elisa kit)
ANTI TPO ELISA KIT
Bile Esculin Disc
CEA ELISA KIT
Cefdinir Antibiotic Disc
Cefuroxime Sodium Antibiotic Disc
Estradiol Elisa Kit
FERRITIN- Elisa
fPSA - Elisa
FSH - Elisa
Furazolidone Antibiotic Disc
Hepatitis A test Kit
Hepatitis E test Kit
LH kit - Elisa
Multistrips- 8 Parameter (Alb,Glucose, pH, Ketone, Blood, Bilirubin, Urobilinogen & Nitrite)
O.T.sterilization solution for fumigation/ mopping, in powder form, Composition :-Potassium Mono per Sulphate (Triple Salt ) - 40% to 50 %, Sodium C 10-13 Alkyl benzene Sulphate - 10% to 20% and Sodium Chloride - 1% to 5%.
Progesterone Elisa Kit
PROLACTIN - Elisa
Roxithromycin Antibiotic Disc
Sabouraud Dextrose Agar (SDA) with CC
Solution for instrumental sterilization in powder form, Composition : Sodium Perborate Monohydrate 50% w/w (0.26% per acetic acid)
Surface & Equipment Disinfectant 2% Solution:Each 100 gm contains : (Ethylenedioxy) dimethanol -14.1 gm, Glutaraldehyde- 5.0 gm
Total PSA Elisa Kit
Vitamin D Elisa Kit
Whole Blood Finger prick HCV card test kit for detection of HCV antibodies Specification 1) The assay should be able to detect antibodies to HCV by chromatographic immuno assay or any other principle. 2) Test should have a sensitivity of 99% -100% and a specificity of 99%-100%. 3) The total test procedure up to the result will not exceed 30 minutes 4) The packing should be in a manner enabling performance of a single test at a time. 5) Storage of the test kits at room temperature should be possible upto 40 degrees celsius 6) Pack size should be for 50 tests. 7) Shelf Life- minimum 18 months from manufacture.
Note : - 1. Quality of the product supplied / to be supplied, may be ascertained by testing / physical examination by the experts at any stage of the tender period. 2. The Items should be US FDA/CE/ ICMR/NIB/CDSCO approved (US FDA/ CE certificate will be applicable only when the Indian Standards like ICMR/NIB/CDSCO is not available). 3. In case of imported items NABL/NIB/NIV/CDL or equivalent authorized Lab accredited by Parent country will be considered. 4. If every supplied batch of the approved vendor contains test report from NIB/NIV/NARI/ICMR then the 2% testing charge will not be deducted from the bill(s).
Medsource Ozone Biomedicals Pvt. Ltd
Nulife
Q-line Biotech Private Limited
SD Biosensor Healthcare Pvt. Ltd
Sirmaxo Chemicals Pvt. Ltd.
BIOGENIX INC
TULIP DIAGNOSTICS PRIVATE LIMITED
Sirmaxo Chemicals Pvt. Ltd.
Medsource Ozone Biomedicals Pvt. Ltd
SD Biosensor Healthcare Pvt. Ltd
BIOGENIX INC
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .