| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC 7 4 DNYANESH SOCIETY WARJE MALWALDI PUNE 411 058 | PUNE | MAHARASHTRA | 411058 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹11.0 L+₹75,825 (7.43%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹12.3 L+₹2.1 L (20.2%)Rejected-Finance S NO 7 3 FLAT NO 4 HILL VIEW RESIDENCY LOHEGAON PUNE 411047 | PUNE | MAHARASHTRA | 411047 | L3 | Rejected-Finance High Rate | |
| 4 | L4₹12.9 L+₹2.7 L (26.2%)Rejected-Finance 20 1 CHANDRA NIVAS APPLEBY ROAD WELLINGTON COONOOR NILGIRIS 643 232 | COONOOR | NILGIRIS | TAMIL NADU | 643232 | L4 | Rejected-Finance High Rate | |
| 5 | L5₹12.9 L+₹2.7 L (26.9%)Rejected-Finance | L5 | Rejected-Finance High Rate |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
4 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Central) Pune
Garrison Engineer (Central) Pune Arjun Marg Pune 411001
8259 REPAIRS/REPLACEMENT AND CLEANING TO SEWAGE LINE, SEPTIC TANKS, SOAKAGE PITS AND COVER SLAB/MAN HOLE COVERS AT AFMC UNDER GE (CENTRAL) PUNE
2021_MES_486577_1
8259 REPAIR REPLACEMENT AND CLEANING TO SEWAGE LIN
Open Tender
Civil Works
Item Rate
270 days
GE (Central) Pune
As per Tender
9 documents required · 9 mandatory
₹500
GE (Central) Pune
₹50,000
Yes
18 Jan 2022
6 Nov 2021
6 Dec 2021
6 Nov 2021
4 Dec 2021
20 Nov 2021
60 days
Amount
Scooping & taking out sludge, sullage and foreign materials by mechanical means from septic tank, soak wells of any description and depth including removing and refixing of accessories and appliances required for safe disposal of sludge, sullage and foreign materials either by carrying the same in covered van/trolley outside defence land and it should be disposed off at such place which is not determinated to public health. (Note :- Depth shall be measured for payment after bailing out water and the rate quoted inclusive of cost required for bailing out water).
Demolition and breaking up RCC, SWG drain pipes set in cement mortar for the following sizes and removing debris from the site complete all as directed by Engr-in-Charge :-
(a) 150 mm bore
(b) 200 mm bore
(c) 250mm dia
(d) 300mm dia
Excavation in trenches not exc 1.5m wide and n.exc 1.5m in depth for foundations, manholes etc and getting out in in soft/loose soil complete all as specified and directed.
All as per item No 3 here-in-above but in hard/dense soil upto 1.5 mtr in depth
M&L 150mm dia RCC pipes class NP-2 with collars laid in treches with cement joint and tested complete all as specified and directed . (Note :- Laying of sewage line in running sewage water & temporary diversion /plugged of existing sewage line & bailing of sewage water is the responsibility of contractor and the rate for the same is seems to be included in the contract)
All as per item above but 200mm dia.
All as per item above but 250mm dia.
All as per item above but 300mm dia.
M&L for PCC 1:4:8 type D2 using 40mm graded agg as in bed to drain pipes including forming cradles for 150mm pipe.
All as per item above but 200mm dia.
All as per item above but 250mm dia.
All as per item above but 300mm dia.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm in soil.
Removing the excavated surplus soils exceeding 50mtr but n.exc 250 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point
S&F in repairs PVC floor trap with steel grating including jointing with solvent cementof 75 mm dia complete all as spd and directed
S&F in repairs PVC gully traps, square 125/110mm size with grating including jointing to waste pipe in cement joint, dia of outlet 100mm complete all as specified and directed.
Cleaning and rodding the blocked sewage line to any depth till the smooth flow of sewage line is restored including plugging of manholes temporarily as and when required and washing down complete sewage line with water including removing sludge and foreign materials from manholes in line and removing and refixing manhole covers and rodding complete all as directed by Engineer-in-Charge for following dia of pipes
(a) 150 mm bore
(b) 200 mm bore
(c) 250 mm bore
(c) 300 mm bore
Cleaning of manholes n.exc. 1.5m deep including desludging and dewatering either by mechanical pump or manually and taking out solids/ sei solids, well flushing with water, removing to a distance exc. 100m but n.exc. 250m and depositing in ditches including necessary excavation and earth work in soft/loose soil for maing ditches over after the sludge are deposited spreading and levelling of excavated soil in the ditches over sludge and removing surplus soil to a distance exc. 50m and sprinkling bleaching powder (including supply of bleaching powder) in a preiphery of one metre around manhole complete all as specified and directed.
All as per item No 18 here-in-before but depth exc. 1.5 mtr and n.exc. 3.00 mtr.
S&F in repairs viterous china wash down water closet pan (squat pan) "Orissa Pattern" white of size 580 x 440 mm including integral foot rests including provn of cement concrete bedding complete all as specified and directed.
S&F in repairs vitreous China wash down water closet pan (pedestal pattern) white excluding flushing cistern and flush pipe complete all as specified and directed.
S&F in repairs vitreous China valveless, symphonic action type flushing cistern 10 ltrs capacity low level white with brackets complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
M & L Non skid ceramic tiles flooring 7 to 8 mm thick area of each tile exceeding 0.06 sqm and not exc 0.11 sqm (300x300mm) with joint free tiles set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15mm thick cement screed bed in CM 1:6 complete.
M & L glazed ceramic tiles in vertical surface 300x200x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick cement screed plaster in CM 1:4 complete
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 Section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required, for the following size of pipe :-
(a) 150mm bore
(b) 200 mm Bore
(c) 250 mm bore
(c) 300 mm bore
Day to day maintenance and petty repair of sewage line (complaints pretaining to safaiwala) by attending daily complaints lodged by the users through IVRS/mobile/sms/ or email and manual registratering of complaints at B/R complaint cell at AFMC Pune on all working days( except sunday, National holidays and closed holidays) by deploying 02 (Two) safaiwala per day, complete all as specified and directed by Engr-in-charge. Note : i) Each job shall consists of 3 complaints and shall be completed with in 24hours. ii) If safaiwala not attended complaint within time frame mentioned above 50 % shall be deducted job completed by him. iii) The contractor will be responsible to maintain daily job completed by the safaiwala deputed by him in the sub work and obtained signature of I/C complaint cell/Engr-in-Charge daily at 1700 hours on all working days.
Demolition of cement concrete in ground floors and paving not exc 15cm thick (below or above ground level) un-reinforced.
M&L for providing precast RCC (1:2:4) type B1 using 20 mm graded stone aggregate in Manholes covers set in CM 1:4 complete including demolition of old existing cover slab all as specified and directed.
M&L for mild steel TMT bars upto 8mm dia cut to length, bent to shape required, bending and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.
M&L PCC (1:4:8) type D-2 as in foundations, filling in mass concrete etc complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar complete all as specified and directed.
M&L for precast cement concrete block masonry exceeding 10cm in width with solid blocks of PCC (1:5:8) grade D-5 and setting in CM 1:6 complete all as specified and directed.
M&L PCC (1:2:4) type B-1 using 20 mm stone graded aggregate as in coping etc complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
Rendering 15mm thick in cement mortar 1:4 on brick/concrete surfaces finished even and smooth using extra cement complete all as specified and directed.
Rendering 15mm thick in cement mortar 1:4 on brick surfaces finished even smooth with spong finish.
Supply only integral water proofing compound
Demolition and breaking of drain pipes AC /CI/PVC set in cement mortar or adhensive all as directed of 75mm to 110 mm dia
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in floors/in earth of 110 mm dia.
All as per item No 38 here-in-above but 75mm dia.
Refixing of old PVC pipes single socketed in any length with rubber ring joints fixed to walls or laid in floors of 110mm dia.
Refixing of old PVC pipes single socketed in any length with rubber ring joints fixed to walls or laid in floors of 75mm dia.
S&F PVC (SWR) bends plain 110 mm bore
S&F PVC(SWR) bends plain 75mm bore
S&F PVC (SWR) bends with oval access door of 110 mm bore
S&F PVC (SWR) bends with oval access door of 75 mm bore
S/F PVC SWR Branch piece single (Single Y) equal or unequal 110mm dia with door access.
S/F PVC SWR Branch piece single (Single Y) equal or unequal 75 mm dia with door access.
S&F PVC (SWR) of 110mm dia junction single (single 'T') equal or unequal with door access.
S&F PVC (SWR) of 75 mm dia junction single (single 'T') equal or unequal with door access.
S/F PVC SWR Branch piece double (double 'Y') equal or unequal 110mm dia with door access.
S/F PVC SWR Branch piece double (double 'Y') equal or unequal 75mm dia with door access.
S&F for 110 mm dia PVC SWR vent cowl
S&F for 75 mm dia PVC SWR vent cowl.
Dismantling stone slab/tiles of any description or thickness, laid, bedded & pointed in cement mortor in floors, hard standing, apron etc
M&L for 75mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base / flooring complete;
M&L for precast coloured, chequered cement concrete tiles, glossy finish of size 305 x 305mm x 25mm thick, conforming to IS-1237 (2006) set jointed and pointed in neat cement slurry in floor laid over and including 20mm thick screed bed in CM (1:6).
M&L for PCC 1:3:6 type C-2, (using 40mm graded stone aggregate) of 75mm thick, laid in alternate bays including in subbase finishing the surfaces even and smooth without using extra cement.
M&L for PCC 1:2:4 type B-1, (using 20mm graded stone aggregate)as in surface channels and drains incl all moulds and forms all as spd and directed.
Extra forming fair finished drain or channel inner girth n.exc 30 CM in cement, concrete using extra cement including forms, moulds, mitred/stopped ends etc complete.
Surface dressing n.exc 15cm deep including cleaning grass vegetation saplings shrubs , bush wood, ungrowth roots and trees not exc 30cm girth including disposal of spoils , in any type of soil all as directed by Engr-in-Charge.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/ loose soil all as specified and directed.
M&L for Machine pressed coloured Glossy finish precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 60mm thickness, M-35 Grade including 30 mm thick grit/stone dust cushioning all as specified and directed.
Fixing only interlocking tiles of any thickness and size including 30 mm thick sand cushoning complete all as spd and directed.
M/L for PCC 1:2:4 type B1 using 20mm graded aggreages as in hardstanding/approaches of 75mm thick
S&F high density 40mm bore polythylene pipes (HDPE) of pressure rating 6 kg/cm2 fixed complete to wall or in floors with necessary socket, elbo & bend etc complete fixed to wall or in floors etc all as complete and directed.
M&L for applying three coats of white washing on new plastered surfaces complete all as spd and directed.
M&L for mild steel clamps, bands straps, supports or stays for soil waste pipe & rain water pipes including fixing clamps with coach screws etc complete all as spd and directed.
L.T Associate
R K CONSTRUCTION AND ENGINEERING
p k enterprises
Mourya Enterprises
Takshashila electricals
shiva traders
M/s Omkar Associates
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .