Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC SCO 26 SEC 30 KURUKSHETRA 136118 | KURUKSHETRA | HARYANA | 136118 | ₹1.3 Cr | L1 | Accepted-AOC accepted |
| 2 | L2₹1.4 Cr+₹3.7 L (2.84%)Rejected-AOC | ₹1.4 Cr+₹3.7 L (2.84%) | L2 | Rejected-AOC rejected |
| 3 | Rejected-Technical | - | - | Rejected-Technical rejected |
| 4 | Rejected-Technical | - | - | Rejected-Technical rejected |
| 5 | Rejected-Technical PLOT NO 729 INDUSTRIAL AREA PHASE 2 | - | - | Rejected-Technical rejected |
Tender Value
₹1.5 Cr
EMD Value
₹3.0 L
Closing Date
26 Apr 2024, 5:00 pmClosed
VISHWNATH KHICHI
ED - Rohtak
The Provision of VRV / VRF System Outdoor, Indoor Unit, Refrigerant piping for VRV / VRF System, Drain piping, Air Distribution System, Acoustic lining of supply Air Duct, Thermal Insulation, Mechanical Ventilation with other accessories have been ta
2024_HRY_369297_1
20241522E3C1 D72E 4CBD 9CB7 A6A7F3494167667BAR
Open Tender
Electrical Works
Works
120 days
Rohtak
Technical documents as per approved DNIT conditions.
3 documents required · 3 mandatory
₹15,000
₹3.0 L
Yes
25 Apr 2025
15 Mar 2024
29 Apr 2024
15 Mar 2024
26 Apr 2024
15 Mar 2024
Amount
HSR Items
[23.22.1.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 125 to 160 amp, 25 KA
[23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA
[23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA
[23.22.4.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.8. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 12 way ( 8 incoming 3phase*12 outgoing)
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole
[23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
[24.1.11]EARTHING AND LIGHTENING ARRESTOR 11. Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required.
[24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required.
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required.
[24.2.7.6]LT CABLE 7.6. Supply and erection of suitable compression type brass cable glands for underground Cable :- 240 sqmm to Cable 3 to 32 Core
NS Items
Supply and erection of 240 Sqmm 3.5 core underground Armd. cable loose in existing pipe or trenches complete in all respect upto the entire satisfaction of Engineer in charge of the work. Make: Havells / Polycab / RR
Supply and erection of 25 Sqmm 4 core underground Armd. cable loose in existing pipe or trenches complete in all respect upto the entire satisfaction of Engineer in charge of the work. Make: Havells / Polycab / RR
SITC of Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. (Insulation Make: K-Flex / Armacell/ Aerofoam ) (Pipe Make: Rajco / Mandev / Totaline / Hariom) (i) 41.3 mm OD (19mm insulation)
SITC of Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. (Insulation Make: K-Flex / Armacell/ Aerofoam ) (Pipe Make: Rajco / Mandev / Totaline / Hariom) (i) 34.9 mm OD (19mm insulation)
SITC of Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. (Insulation Make: K-Flex / Armacell/ Aerofoam ) (Pipe Make: Rajco / Mandev / Totaline / Hariom) (i) 28.58 mm OD (19mm insulation)
SITC of Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. (Insulation Make: K-Flex / Armacell/ Aerofoam ) (Pipe Make: Rajco / Mandev / Totaline / Hariom) (i) 22.2 mm OD (19mm insulation)
SITC of Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. (Insulation Make: K-Flex / Armacell/ Aerofoam ) (Pipe Make: Rajco / Mandev / Totaline / Hariom) (i) 19.05 mm OD (19mm insulation)
SITC of Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. (Insulation Make: K-Flex / Armacell/ Aerofoam ) (Pipe Make: Rajco / Mandev / Totaline / Hariom) (i) 15.88 mm OD (19mm insulation)
SITC of Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. (Insulation Make: K-Flex / Armacell/ Aerofoam ) (Pipe Make: Rajco / Mandev / Totaline / Hariom) (i) 12.7 mm OD (13 mm insulation)
SITC of Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. (Insulation Make: K-Flex / Armacell/ Aerofoam ) (Pipe Make: Rajco / Mandev / Totaline / Hariom) (i) 9.52 mm OD (13 mm insulation)
SITC of Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. (Insulation Make: K-Flex / Armacell/ Aerofoam ) (Pipe Make: Rajco / Mandev / Totaline / Hariom) (i) 6.35 mm OD (13 mm insulation)
Supply, installation testing and commissioning of Rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation complete in all respect upto entire satisfaction Engineer in charge of work. Make: AKG / BEC / Diplast / Norpack / MK (i) 25 mm dia
Supply, installation testing and commissioning of Rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation complete in all respect upto entire satisfaction Engineer in charge of work. Make: AKG / BEC / Diplast / Norpack / MK (i) 32 mm dia
Providing, Fixing and Running of Touch Type Centralized Controller (capable of at least to control 128 indoor units) for all VRV/VRF /AHU Indoor /Outdoor Units and Must Be Compatible with BMS complete in all respect upto the entire satisfaction of Engineer in charge of the work
SITC of Control cabling of size 1 Sqmm 2 Core Copper cable complete in all respect upto entire satisfaction Engineer in charge of work. Make: Polycab / Havells / RR (i) 1 Sqmm 2 Core Copper wire
Civil Work (Including Holes, Chisseling, Repair and Foundations) complete in all respect upto entire satisfaction Engineer in charge of work.
SITC of 16 Sqmm 4 Core Cable Copper Unarmd. Power Cable, loose/ in existing pipe complete in all respect with petty material and necessary connections upto the entire satisfaction of engineer in charge of work. Make: RR / Polycab / Havells
SITC of 25 Sqmm 4 Core Cable Copper Unarmd. Power Cable, loose/ in existing pipe complete in all respect with petty material and necessary connections upto the entire satisfaction of engineer in charge of work. Make: RR / Polycab / Havells
Supply, installation testing and commissioning of Air Cooled VRV/VRF units with Rotary /scroll Compressor capable of modulating capacity ,i,e it should be able to vary speed of the compressor as per the varying load conditions and works on R410A with heating and cooling both.The outdoor unit shall be a factory assembled unit housed in a sturdy weather proof casing constructed form rust-proofed mild steel panels coated with powder coated finish. Each ODU should have variable compressors. Each unit shall be equipped, with an oil separator to ensure stable operation with long refrigerant piping.Note:- Variable refrigerant flow modular type air- conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor Outdoor unit having minimum COP at 100% Load to be )3.85 as per ARI Conditions complete in all respect upto entire satisfaction Engineer in charge of work. The manufacturer of ODU and compressor shall be same. i.e the make of compressor shall be identical of the ODU complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. . Makes: Mitsubishi Electric / Daikin / Toshiba / LG / O General / Voltas / Samsung. Outdoor units. (i) 42 HP
Supply, installation testing and commissioning of Air Cooled VRV/VRF units with Rotary /scroll Compressor capable of modulating capacity ,i,e it should be able to vary speed of the compressor as per the varying load conditions and works on R410A with heating and cooling both.The outdoor unit shall be a factory assembled unit housed in a sturdy weather proof casing constructed form rust-proofed mild steel panels coated with powder coated finish. Each ODU should have variable compressors. Each unit shall be equipped, with an oil separator to ensure stable operation with long refrigerant piping.Note:- Variable refrigerant flow modular type air- conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor Outdoor unit having minimum COP at 100% Load to be )3.85 as per ARI Conditions complete in all respect upto entire satisfaction Engineer in charge of work. The manufacturer of ODU and compressor shall be same. i.e the make of compressor shall be identical of the ODU complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Makes: Mitsubishi Electric / Daikin / Toshiba / LG / O General / Voltas / Samsung. Outdoor Units. (i) 68 HP
SITC of Cassette type indoor air conditioner units complete with evaporator coil, fan and fan motor drain pump drain pan and Grille panel interconnecting it with refrigerant piping insulation cabling earthing necessary galvanized steel supports etc. as per specification and drawing . The units shall be of following capacities complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Makes: Mitsubishi Electric / Daikin / Toshiba / LG / O General / Voltas / Samsung. (i) 4.0 TR
SITC of Cassette type indoor air conditioner units complete with evaporator coil, fan and fan motor drain pump drain pan and Grille panel interconnecting it with refrigerant piping insulation cabling earthing necessary galvanized steel supports etc. as per specification and drawing . The units shall be of following capacities complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Makes: Mitsubishi Electric / Daikin / Toshiba / LG / O General / Voltas / Samsung. (i) 3.2 TR
SITC of Cassette type indoor air conditioner units complete with evaporator coil, fan and fan motor drain pump drain pan and Grille panel interconnecting it with refrigerant piping insulation cabling earthing necessary galvanized steel supports etc. as per specification and drawing . The units shall be of following capacities complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Makes: Mitsubishi Electric / Daikin / Toshiba / LG / O General / Voltas / Samsung. (i) 2.6 TR
SITC of Cassette type indoor air conditioner units complete with evaporator coil, fan and fan motor drain pump drain pan and Grille panel interconnecting it with refrigerant piping insulation cabling earthing necessary galvanized steel supports etc. as per specification and drawing . The units shall be of following capacities complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Makes: Mitsubishi Electric / Daikin / Toshiba / LG / O General / Voltas / Samsung. (i) 2.0 TR
SITC of Cassette type indoor air conditioner units complete with evaporator coil, fan and fan motor drain pump drain pan and Grille panel interconnecting it with refrigerant piping insulation cabling earthing necessary galvanized steel supports etc. as per specification and drawing . The units shall be of following capacities complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Makes: Mitsubishi Electric / Daikin / Toshiba / LG / O General / Voltas / Samsung. (i) 1.6 TR
SITC of cassette type indoor air conditioner units complete with evaporator coil, fan and fan motor drain pump drain pan and Grille panel interconnecting it with refrigerant piping insulation cabling earthing necessary galvanized steel supports etc. as per specification and drawing . The units shall be of following capacities complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Makes: Mitsubishi Electric / Daikin / Toshiba / LG / O General / Voltas / Samsung. (i) 0.8 TR
SITC of cassette type indoor air conditioner units complete with evaporator coil, fan and fan motor drain pump drain pan and Grille panel interconnecting it with refrigerant piping insulation cabling earthing necessary galvanized steel supports etc. as per specification and drawing . The units shall be of following capacities complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Makes: Mitsubishi Electric / Daikin / Toshiba / LG / O General / Voltas / Samsung. (i) 1.0 TR
SITC of cassette type indoor air conditioner units complete with evaporator coil, fan and fan motor drain pump drain pan and Grille panel interconnecting it with refrigerant piping insulation cabling earthing necessary galvanized steel supports etc. as per specification and drawing . The units shall be of following capacities complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Makes: Mitsubishi Electric / Daikin / Toshiba / LG / O General / Voltas / Samsung. 1.6 TR
SITC of 2.3 TR indoor units with evaporator coil, fan and fan motor drain pan complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Makes: Mitsubishi Electric / Daikin / Toshiba / LG / O General / Voltas / Samsung. (i) 2.3 TR
SITC of Corded Remote Controls with cord for ductable / Cassette ACs complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work Makes: Mitsubishi Electric / Daikin / Toshiba / LG / O General / Voltas / Samsung
SITC of fitting REFNETS / T / Y - Joints etc. as per specifications complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Makes: Mitsubishi Electric / Daikin / Toshiba / LG / O General / Voltas / Samsung.
SITC of 2.3 Ton indoor units with evaporator coil, fan and fan motor drain pan complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Makes: Mitsubishi Electric / Daikin / Toshiba / LG / O General / Voltas / Samsung. 2.3 TR
Supply and Erection of 12 MM thick toughned transparent glass, including of Silicon fixtures, handles, locks, doors, Machine Sets, L Chanel Big and Small, U Chanels and material required to complete the job in all respect upto the Entire Satisfaction of the Engineer-in-Charge of the work Make: - AIS / Saint Gobain
modern cooling solution
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .