Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.5 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹30.3 L+₹3.6 L (13.5%)Rejected-Finance | L2 | Rejected-Finance Other than being lowest | |
| 3 | L3₹31.8 L+₹5.1 L (19.2%)Rejected-Finance FLAT NO A 102 ASHOKVAN RAJSHIV CO OP HSG SOC SHIV VALLABH ROAD DAHISAR EAST MUMBAI 400 068 | MUMBAI SUBURBAN | MAHARASHTRA | 400068 | L3 | Rejected-Finance Other than being lowest | |
| 4 | L4₹32.6 L+₹5.9 L (22.1%)Rejected-Finance SIDDHARTH CO 24 PADMAVATI SOCIETY VALLABH NAGAR BHURAVAV GODHRA GUJARAT 389001 | PANCH MAHALS | GUJARAT | 389001 | L4 | Rejected-Finance Other than being lowest | |
| 5 | L5₹32.9 L+₹6.2 L (23.2%)Rejected-Finance | L5 | Rejected-Finance Other than being lowest |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
3 Feb 2022, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR REPLACEMENT OF UNSERVICEABLE LOFT TANKS PVC WATER STORAGE TANK OF VARIOUS CAPACITY CLEANING AND ALLIED WORKS AT OLD AND NEW NAVY NAGAR AREA UNDER GE NW NAVY NAGAR COLABA MUMBAI
2022_MES_500816_1
8261/CWE(NW)MUMBAI/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) Navy Nagar
Class D
7 documents required · 7 mandatory
₹500
Yes
GE (NW) Navy Nagar
₹76,000
Yes
8 Mar 2022
11 Jan 2022
5 Feb 2022
11 Jan 2022
3 Feb 2022
27 Jan 2022
11 Jan 2022 - 25 Jan 2022
Amount
Cleaning of underground sump of any capacity cleaning the floors, wall and ceiling portion of sump etc by Mechnical high pressure spray and steel wire brush to remove Algae/dirt/foreign dirt completely and soaking out the water/dirt with a high pressure wet vaccum pump and removing spoils out side of MoD land and distance exc 5 KMs & n.exc 10 KMs and applying spray of approved chemical etc. complete all as specified and as directed by Engineer-in-charge . Note :- 1. Rates deemed to be included for pumping out water left below foot valve. 2. Rate include the painting of two coats of enamal paint with visible colour and capacity of sump about date of cleaning and due date for cleaning complete all as specified.
(a) Sump capacity of approximately 9,20,000 liters
(b) Sump capacity of approximately 16,00,000 liters
(c) Sump capacity of approximately 14,00,000 liters
(d) Sump capacity of approximately 4,50,000 Liters
(e) Sump capacity of approximately 3,20,000 Liters
(f) Sump capacity of approximately 2,00,000 Liters
(g) Sump capacity of approximately 2,50,000 Liters
(h) Sump capacity of approximately 1,50,000 Liters
Cleaning of PVC and RCC water storage tank in low and high rising buildings(G+14) by mechanical high pressure spray and remove all foreign matter completely and soaking out the water/dirt with a high pressure wet vaccum pump and removing spoils out side of MoD land and complete all as specified and as directed by Engineer-in-charge . Note: Rate include the painting of two coats of enamal paint with visible colour about date of cleaning and due date for cleaning complete all as specified and as directed
a) OH Tank of capacity 5000 Litres
b) OH Tank of capacity 3000 Litres
c) OH Tank of capacity 10000 Litres
Cleaning the vegetation including grass, bushes small trees and all vegetation growth complete including uprooting of bushes and small trees around the installation/sump/OH reservoir, valve chamber etc. filling the rough holes with earth and levelling the surfaces by removing all debris to a distance n.exc.50m complete all as specified and as directed.
Supply and fixing in repairs FRP lid cover for PVC water storage tank complete accessory for closing and locking arrangement suitable for various capacity as approved by BMC complete all as specified and as directed
a)For capacity of 5000 litres
b) For capacity of 3000 litres
Demolition of cement concrete(unreniforced) and removing debries away from MoD land complete all as specified and as directed
Material and labour cement concrete 1:2:4 ,type B-2 (using 40mm graded stone aggregate) of any height of foundation for suporting PVC tank complete all as specified and as directed
Fixing in repairs CP stop cock, brass, screwed down with crutch or butterfly handle suitable for GI or PVC tubing 15 mm dia bore including necessary clamp & saddles complete all as specified and as directed
Fixing in repairs long body CP bib cock brass with crutch or butterfly handle screwed both ends for GI or pvc tubing 15 mm dia bore including necessary clamp & saddles etc complete all as specified and as directed
Fixing in repairs Ball valves 15 mm bore high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete all as specified and as directed
Fixing in repairs Ball valves 25 mm bore high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete all as specified and as directed Note:- Materials against item Nos 7 to 10 shall be issued under scheduled 'B' free for fixing only.
Supply and Fixing in repair/replacement of internal steel water tubing, galvanised, Medium grade with all fittings in shafts such as nipple, union, socket, elbow, bends, fixed to wall including necessary & capacity up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge. NOTE:Clamping of above line with suitable size of stainless steel saddles at 2 meter apart and work should be done in shaft of high rise building(G+14) and quoted rate should be include necessary Scaffolding and clamping materials
(a) 40 mm bore
(b) 50mm bore
(c) 80mm bore
(d) 100 mm bore
Supply and Fixing in repair/replacement of internal steel water tubing with CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings including union, socket, elbow, bends fixed in wall and shafts including necessary saddling and and work to be done in high rise building up to 15 th floor short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge of the following size :-.
(a) 20 mm Nominal outside dia
(b) 25mm Nominal outside dia
Supply and fixing stainless steel mosquito net(corrision resistance ) for Air vent pipes on various OHT and sumps complete all as specified and as directed
Supply & Fixing in repairs Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc with Fe 410 -W (Gde- E- 250) including making paint with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M& L for Cleaning of loft tanks of capacity 170 to 275 ltrs in existing position by mechanised pressure, cleaning using PVC tank cleaning solution and draining out the water by wet vaccum pump, rinsing with clean drinking water complete all as specified and as directed Note : Any damage to pipe and PVC tank during cleaning shall be made good by the contractor at his own cost.
Supply and fixing in repairs PVC water storage Tank with cover triple layer pure anti microbial round type and dismantling of existing pipeline and making connections including replacement of new GI fittings i.e. tank nipple, washers , Pipes for connecting the existing delivery lines complete all as specified and directed for the following capacity :- Note :- Pipes if reqd only shall be paid under relevant item of Schedule 'A' remaining items shall be deemed to be included in the item rate.
(a) 5000 Ltr capacity
(b) 3000 Ltr capacity
Supply and fixing in repairs MS pipe heavy grade for vent pipe including making hole on tank necessary fitting including welding, Bending as per sample and providing necessary PCC support, painting with two coats of synthetic enamel paint over a coat of red oxide primer all as specfied and directed by Engineer-in-charge of following sizes :-
(a) 100mm dia
(b) 80mm dia
Supply & fix in replacement of unserviceable PVC loft tank (HDPE) of capacity 275 ltrs with complete fitting including 03 Nos adopter with washer for inlet/outlet over flow as per manufactureres instructions complete all as specified and directed by Engineer-in-Charge
Supply and fixing replacement PVC profile suitable for 275 ltr loft tank including fixing of aluminium channel around the profile complete all as specified and directed by Engg-In- Charge.
Supply and fixing in repairs Flow meter of size 300 mm dia flanged class B type including cutting of existing pipe, welding, DI fittings, Nut bolts as reqd at site and testing complete all as specified and directed.
Supply and fixing in repairs Flow meter of size 200 mm dia flanged class B type including cutting of existing pipe, welding, DI fittings, Nut bolts as reqd at site and testing complete all as specified and directed.
Supply and fixing in repairs Flow meter of size 150 mm dia flanged class B type including cutting of existing pipe, welding, DI fittings, Nut bolts as reqd at site and testing complete all as specified and directed.
Supply and fixing in repairs Flow meter of size 80 mm dia flanged class B type including cutting of existing pipe, welding, DI fittings, Nut bolts as reqd at site and testing complete all as specified and directed.
M/S V N ENTERPRISES
BOB ENTERPRISES
siddharth and company
Angrahit Services Trading Co
vikas construction
Unitech Enterprises
Shetty Construction Co
SHRI SAI ENTERPRISES
SHREE JAGDISH FURNITURE CO.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .