Loading…
Loading…
Tender Value
₹26.4 L
EMD Value
₹52,800
Closing Date
23 Sept 2026, 1:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
12 conditions · 1 needing a document upload
Clause Regarding GST: (a) All the Bidders/tenderers should ensure that they are GST Compliant and their quoted tax Structure are as per GST LAW.(b) Tenderer Should Furnish their GSTIN numbers representing the States in Which they are registered GST, along with address of Registered Office.(c)The Contract is under GST Act and rules as applicable time to time.
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
34 conditions · 6 needing a document upload
Check List: The tenderer(s) would fill up the check list, as per Annexure-XXIII to ensure that they are submitting the complete tender offer.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Electrical work for Water treatment plant, provision of water efficient fixtures, improvement of drainage system, development of green areas, etc. at various colonies under ADEN/DBRT.
LV-T-14-958~NFR
LV-T-14-958
Open
Works - General
12 Months
Tinsukia, Assam
₹0
₹52,800
1 Sept 2026
1 Sept 2026
9 Sept 2026
55 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 26,40,778.37 | ||
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of energy efficient 7.5KW/10 HP multistage submersible pumping set, discharge capacity: ( 500-1100) LPM for a head of (54-27) Mtrs , outlet pipe size: 80 mm. | — | — | — | 1,21,000 | |
| — | 2.00 | — | — | ||
| Supply of energy efficient 7.5KW/10 HP multistage submersible pumping set, discharge capacity: ( 500-1100) LPM for a head of (63-16) Mtrs , outlet pipe size: 80 mm. | — | — | — | 1,21,000 | |
| — | 4.00 | — | — | ||
| Supply, installation, testing & commissioning of Automatic Star Delta Starter in sheet steel enclosure For 20HP/15 KW pump with Robust 4 pole contactor, Overload relay with built in single phase preventor, Relay Amps 14-22 Amps with Electronic Star delta timer suitable for 415 V. 50Hz. AC supply made out of 16 SWG CRCA sheet. The panel shall be totally enclosed, dust & vermin proof, neoprene gasket of thickness not less than 2 mm shall be used between all adjacent units & beneath all covers so that the joints are effectively dust vermin proof. The panel shall have uniform height & depth with insulated & spring loaded thumb screws. The busbar chamber shall have 3 phase & neutral Cu. busbar. The panel shall be complete with PVC insulated Cu. wire & shall be ready for connection to the equipments. | — | — | — | 79,160 | |
| — | 12.00 | — | — | ||
| a) Supply and erection of Double Arm type Hot Dip Galvanized in single deep to average 65 micron DFT 5 mtr. long octagonal pole with sectional dia 130x70 mm, overall sectional thickness 3 mm complete with base plate size 200x200x12 mm, 4 Nos. 600 mm long foundation bolt of 16 mm dia with all other accessories as per direction of Engineer in charge at site. b) Supply and erection of PCC/RCC/shallow foundation 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) M15 Grade of size and depth as per recommendation and drawing of the manufacturer (approx. 1.6 mtr.x 0.6 mtr.x0.6 mtr.) with excavation of earth for foundation of all depth and all places, nature and condition of soil including de-watering, shoring, shuttering, batching, mixing, placing, leveling, carrying etc and re-filling the pit after completion of foundation work from excavated earth or borrowed pit by contractor's own arrangement for octagonal poles. | — | — | — | 2,52,612 | |
| — | 2.00 | — | — | ||
| Supply Installation, testing and commissioning of of Horizontal Centrifugal Mono block Pump 7.5 HP/5.5 KW, Three Phase, 50 HZ, Head Range: 28-42 Mtrs, Discharge: 10-5.5 LPS, Suction/ Delivery pipe Size: 80 mm/65 mm, IP 55 Protected, Insulation: F class. The work includes construction of required foundation for securing the pump and all required accessories. | — | — | — | 92,417.6 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing & commissioning of Automatic Star Delta Starter in sheet steel enclosure For 12.5HP/9 KW pump with Robust 4 pole contactor, Overload relay with built in single phase preventor, Relay Amps 9-14 Amps with Electronic Star delta timer suitable for 415 V. 50Hz. AC supply made out of 16 SWG CRCA sheet. The panel shall be totally enclosed, dust & vermin proof, neoprene gasket of thickness not less than 2 mm shall be used between all adjacent units & beneath all covers so that the joints are effectively dust vermin proof. The panel shall have uniform height & depth with insulated & spring loaded thumb screws. The busbar chamber shall have 3 phase & neutral Cu. busbar. The panel shall be complete with PVC insulated Cu. wire & shall be ready for connection to the equipments. | — | — | — | 35,000 | |
| — | 70.00 | — | — | ||
| Supply, laying, connection of GI pipe 80 mm dia(Heavy Gauge) as per IS : 1239 with necessary GI flange and including welding of GI flanges as required as per direction of Engineer Incharge at Site. | — | — | — | 90,370 | |
| — | 2.00 | — | — | ||
| Supply, fitting, fixing of exhaust fan 300 mm sweep metallic type | — | — | — | 2,945.48 | |
| — | 100.00 | — | — | ||
| Supply of Flat Three Core 6 SQ mm PVC Insulated & PVC Sheathed Industrial Cable for Submersible Pump Motors 1100 Volt, conforming to IS 694 | — | — | — | 33,920 | |
| — | 2.00 | — | — | ||
| Supply, fitting, fixing of CI Non return valve(Flanged) 80 mm dia, PN 1.6 as per IS 5312(Part 1): 2004 | — | — | — | 7,200 | |
| — | 10.00 | — | — | ||
| Erection of earth by 50 mm dia 3 Mtrs. long (3.6 mm thickness) GI pipe and 32x6 mm GI strip-5 Mtrs,GI nuts, bolts including masonry materials for earthing pit, salt, charcoal etc. and construction of earth pit covered with RCC cover slab 12.7 mm thickness and watering pipe per Drawing No PCEE/ELG/DRG/2024/1 Dtd 30.09.2024 | — | — | — | 43,535.4 | |
| — | 50.00 | — | — | ||
| Supply, Laying of PVC Pipe(Medium Gauge) , 32 mm dia. | — | — | — | 4,500 | |
| — | 12.00 | — | — | ||
| Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type wiring of light point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A, ceiling rose, GI box with suitable modules for fixing switches . | — | — | — | 7,853.64 | |
| — | 1.00 | — | — | ||
| Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type wiring of Fan Point/Exhaust fan point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A, ceiling rose,Modular regulator 100W, Modular GI metal box with suitable modules for fixing switches & Regulators and 1.0 sq mm multistrand FRLS copper Cable in green for earth contuinity wire . | — | — | — | 945.33 | |
| — | 6.00 | — | — | ||
| Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type wiring 5 A plug point from main/sub-main board to the points by 1.5 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 5 A ,GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire. | — | — | — | 2,566.02 | |
| — | 6.00 | — | — | ||
| Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type wiring 15 A plug point from main/sub-main board to the points by 4 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 15 A , GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire. | — | — | — | 7,378.02 | |
| — | 180.00 | — | — | ||
| Supply, drawing and connection of single core 6 sq. mm PVC insulated & unsheathed multistrand FRLHS copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site rigid PVC conduit pipe 32 mm dia concealed through walls/surface as required. | — | — | — | 19,188 | |
| — | 270.00 | — | — | ||
| Supply, drawing and connection of single core 4 sq. mm PVC insulated & unsheathed multistrand FRLHS copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site rigid PVC conduit pipe 32 mm dia concealed through walls/surface as required. | — | — | — | 15,298.2 | |
| — | 360.00 | — | — | ||
| Supply, drawing and connection of single core 2.5 sq. mm PVC insulated & unsheathed multistrand FRLHS copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site. through rigid PVC conduit pipe 32 mm dia concealed through walls/surface as required. | — | — | — | 13,957.2 | |
| — | 12.00 | — | — | ||
| Supply, fitting, fixing, testing, and commissioning of LED batten light, 20 Watt, 4 feet long, with extruded aluminium housing for effective heat dissipation, complete with high-efficiency LEDs, integral electronic driver, uniform glare-free illumination, and long service life, suitable for surface mounting, operating on 230 V AC, 50 Hz supply, with minimum IP20 protection, complete with all mounting accessories, internal wiring, connectors, testing, and commissioning, inclusive of all materials, labour, tools, complete in all respects as per directions of the Engineer-in-Charge | — | — | — | 3,013.56 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of VTPN Distribution Board System type 4 way double door, IP 43 Protection,Shrounded Neutral Bar and as per assembly with flexible connecting link., cement spill protector, door earthing with the following: (i) MCCB, 4 pole, 100 Amps, 16 KA BC= 1 No (ii) MCB , SP, 63 Amps, 'C' series, Icn =10KA BC=4 Nos. (iii) MCB, SP, 32 Amps, 'C' series, Icn =10KA BC=3 Nos | — | — | — | 58,740 | |
| — | 300.00 | — | — | ||
| Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 25 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024 | — | — | — | 2,77,524 | |
| — | 600.00 | — | — | ||
| Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 16 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024 | — | — | — | 4,95,576 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of Sewage Submersible Dewatering Pump, 3 Phase, 415 Volts, 50 Hz, 15 HP (11 kW), 4 Pole, closed-coupled construction, suitable for sewage pumping application, complete with K-type non-clog channel impeller. Pump shall have 100 mm minimum discharge outlet with head of 14 metres, discharge capacity of minimum 4750 LPM at 8 metres head, speed 1440 RPM, with Cast Iron impeller and pump casing/body, Carbon Steel pump shaft, IP68 protection, suitable for continuous duty operation, including all accessories required for satisfactory operation, complete as specified and as directed by the Engineer-in-Charge. | — | — | — | 3,49,634 | |
| — | 4.00 | — | — | ||
| Supply, fitting, fixing of 200 Amps outdoor type cable junction box, angle frame mounted, dust & vermin proof, complete with rain cap, aluminium basbar of suitable size for TPN, 200 Amps, 415 V made out of 16 SWG CRCA sheet duly painted, Cable Junction Box Size: (lxbxh=450x 450x600 mm). The base of the fedder pillar junction box to be provided with CC foundation of propotion 1:1.5:3( cement, sang,Chips) after connection of Ug cables. | — | — | — | 35,756 | |
| — | 24.00 | — | — | ||
| Supply, fitting, fixing of LED Street Light 45 W to be fixed on octagonal pole. Specification of 45 W Street light : Housing: Pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management, sturdiness & excellent corrosion resistance. Cable gland is used for maintaining ingress protection, Finish: Epoxy powder coated siemens grey after phosphochromate treatment,Light source :High efficiency long life LED chip in modules with lumen efficacy of 100 lm/W with PC lens to ensure better uniformity of light distribution. Cover: Tempered protective toughened glass, thermal, shock and impact-resistant, fixed to the housing with SS screws. Electronic Driver: Built-in potted electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection & other safety tests as per IS 15885 Part-2/Sec with IP 65,IK07 protection. | — | — | — | 1,13,287.92 | |
| — | 12.00 | — | — | ||
| Supply, installation, testing and commissioning of LED Pole Lamp, 2400 mm height, comprising 3 x 8 Watt COB LED modules, complete with integrated driver, having minimum luminous flux of 2700 lumens, beam angle of 100°, ingress protection rating IP65, impact resistance IK07, suitable for outdoor landscape/pathway lighting applications. The luminaire shall be fabricated from corrosion-resistant material with powder-coated finish, complete with all mounting accessories, foundation hardware, internal wiring, termination, and all other accessories required for satisfactory operation, complete as specified and as directed by the Engineer-in-Charge. | — | — | — | 3,56,400 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCAPRIL2022WITHALLACS.pdf
ATTACHMENT
AnnexuresSectionVII.pdf
ATTACHMENT
TenderDocument958corrected.pdf Tender Document958
ATTACHMENT
TenderDocument958corrected.pdf
ATTACHMENT
TenderDocument958corrected.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .