| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.4 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹9.5 L+₹2.1 L (28.4%)Rejected-Finance | 2 | Rejected-Finance Not Lowest | |
| 3 | 3₹8.4 L+₹1.0 L (13.6%)Rejected-Finance | 3 | Rejected-Finance Not Lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
14 Aug 2020, 6:00 pmClosed
Garrison Engineer Abohar
Garrison Engineer Abohar Pin 152116
Repair / maint of internal wiring including fitting and other connected items in Md area at Mil Stn Fazilka
2020_MES_358882_1
GE ABH-21/20-21
Open Tender
Civil Works
Item Rate
240 days
Fazilka Mil Stn
MES Registered Contractor enlisted in class E Category b (i) having deposited standing security of Rs 50000 with departments. Contractors not registered in MES should meet the MES enlistment criteria corresponding to appropriate class and category
5 documents required · 5 mandatory
₹500
Garrison Engineer Abohar
₹30,000
Yes
17 Sept 2020
7 Jul 2020
17 Aug 2020
7 Jul 2020
14 Aug 2020
22 Jul 2020
Amount
Taking down aluminium / Copper point wiring (light, fan, socket or power, bell complete fittings such as sockets, ceiling roses, pendants, battens/ conduits (as required), holders, regulators and making good the disturbed surfaces of walls, floors, ceiling etc all as specified and directed by Engineer - in - Charge.
Taking down unserviceable main switches and MCB distribution boards single phase all as specified and directed by Engineer - in - Charge.
M & L point wiring (CONCEALED) complete with 1.5 Sqmm (nominal area) PVC FRLS insulated unsheathed copper stranded conductor cable with colour code in and including medium grade rigid PVC conduit with tees, bends, elbows, couplers, MS junction boxes concealed after cutting chases in wall, floor etc and making good to match with existing surface including sunken iron terminal box, 3mm thick bakelite sheet cover, clips, pipe hooks, brass screws, washers and 1.5 Sqmm single core stranded / solid copper conductor 1100 volts grade PVC insulated and unsheathed cable as earth continuity conductor to common earth and connecting to earth dolly for One light /bell point/ fan point controlled by one, one way switch all as specified and directed at site by Engineer – in – Charge.
All as per item No. 03 here in before but for socket out let 3 pin 5 amp on same board all as specified and directed by Engineer - in - Charge
All as per item No. 03 here in before but for socket out let 3 pin 5 amp on independent board all as specified and directed by Engineer - in - Charge
All as per item No. 03 here in before but One light point controlled by two 2 - w a y s w i t c h e s , with cables 1.5 sq. mm size all as specified and directed by Engineer - in - Charge
All as per Srl item No. 03 here-in-before but with 2.5 Sqmm single core multi stranded copper conductor of 1100 volts grade PVC FRLS insulated and unsheathed cable for one multipurpose switch socket outlet 6 pin, 15 Amps on independent board including 2.5 Sqmm single core stranded / solid copper conductor 1100 volts grade PVC insulated and unsheathed cable as earth continuity conductor to common earth and connecting to earth dolly.
M & L point wiring complete with 1.5 Sqmm single core multi stranded copper conductor of 1100 volts grade PVC FRLS insulated and sheathed cable drawn through in existing conduit with and including sunk type MS pressed steel terminal box for mounting fittings like switches, sockets, fan regulators etc with 3mm thick plastic laminated sheet top cover including 1.5 Sqmm single core stranded / solid copper conductor 1100 volts grade PVC insulated and sheathed cable as earth continuity conductor to common earth and connecting to earth dolly for One light/ bell point/ fan point controlled by one, one way switch all as specified and directed at site by Engineer - in- charge.
All as per item No. 08 here in before but for socket out let 3 pin 5 amp on same board all as specified and directed by Engineer - in - Charge
All as per item No. 08 here in before but for socket out let 3 pin 5 amp on independent board all as specified and directed by Engineer - in - Charge
M & L point wiring complete with 2.5 Sqmm single core multi stranded copper conductor of 1100 volts grade PVC FRLS insulated and sheathed cable drawn through in existing conduit with and including sunk type MS pressed steel terminal box for mounting fittings like switches, sockets, fan regulators etc with 3mm thick plastic laminated sheet top cover including 2.5 Sqmm single core stranded / solid copper conductor 1100 volts grade PVC insulated and sheathed cable as earth continuity conductor to common earth and connecting to earth dolly for One light/ bell point/ fan point controlled by one, one way switch all as specified and directed at site by Engineer - in- charge.
S&F lamp holder, PVC / polycarbonate type with back plate for batten fittings all as specified and directed by Engineer - in - Charge.
Fixing only as in repairs lamp holder, PVC / polycarbonate type with back plate for batten fittings all as specified and directed by Engineer - in - Charge.
S & F switch piano flush type single pole one way 5 Amp all as specified and directed by Engineer - in – Charge.
Fixing only as in repairs switch piano flush type single pole one way 5 Amp all as specified and directed by Engineer - in – Charge.
S & F switch piano flush type single pole one way 15 Amp all as specified and directed by Engineer - in – Charge.
Fixing only as in repair switch piano flush type single pole one way 15 Amp all as specified and directed by Engineer - in – Charge.
S & F bell push flush type, single pole, one way, 5 Amp all as specified and directed by Engineer - in – Charge .
S&F electric bell, AC, 230 volts, single pole, complete all as specified and as directed by Engineer-in-Charge.
S&F socket outlet 2 in 1 , 3 pin, 5 Amps, flush type all as specified and directed by Engineer-in –Charge.
S&F socket outlet 2 in 1, 6 pin, 5 and 15 Amps, flush type complete all as specified and as directed by Engineer-in-Charge.
Fixing only as in repairs socket outlet 3 pin, 5 Amps, flush type all as specified and directed by Engineer-in –Charge.
S&F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal all as specified and directed by Engineer-in –Charge.
S & F MCB distribution board of sheet metal single pole and neutral 8 way, double door, with 200 Amp rated bus bar 240 volt all as specified and directed by Engineer-in- Charge.
S & F sheet metal enclosure distribution board triple pole and neutral 4 way, double door, with 200 Amp rated bus bar 440 volt all as specified and directed by Engineer-in- Charge.
S & F MCB single pole & neutral 6 to 32 Amp 240 volt with rupturing capacity not less than 10 KA all as specified and directed by Engineer – in – Charge .
S & F MCB single pole 6 to 32 Amp 240 volt with rupturing capacity not less than 10 KA all as specified and directed by Engineer – in – Charge .
S & F MCB triple pole 63 Amp 440 volt with rupturing capacity not less than 10 KA all as specified and directed by Engineer – in – Charge .
S&F MCCB, (AC 415 V), fixed thermal & magnetic setting, triple pole, 100 Amps, breaking capacity 16 KA complete all as specified and as directed by Engineer-in-Charge.
S&F MCCB, (AC 415 V), fixed thermal & magnetic setting, triple pole, 63 Amps, breaking capacity 25 KA complete all as specified and as directed by Engineer-in-Charge.
S & F ceiling rose 65 x 50mm three terminals PVC/ polycorbonate, isolated body all as specified and directed by Engineer - in - Charge .
Fixing only as in repairs ceiling rose surface bakelite 65 x 50mm three terminals all as specified and directed by Engineer - in - Charge .
S&F fan regulator electronic stepped heavy duty flush type 230 volt AC single phase fixed on laminated sheet top cover (laminated sheet top cover is included in rates under respective items of point wiring) and connecting up complete all as specified and directed by Engineer-in-Charge.
Fixing only as in repairs fan regulator electronic stepped heavy duty flush type 230 volt AC single phase fixed on laminated sheet top cover after cutting necessary chases to required size complete connections all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to and including galvanized earth lead wire 4mm dia by means of GI bolts, nuts, check nuts and washers and connected other end to main board duly protected by GI pipe 15mm bore, medium grade, earth plate surrounded by packed layer of coal dust and common salt 15cm thick all around bottom and top watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate No. 3 of SSR Part – I and connecting to earthing test point, main switch board and testing on completion including CI cover, frame and PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in earthing pit with CI cover and frame including necessary earth works etc, all as specified and directed by Engineer - in – Charge. Note:- 1. PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode of the earth pit and pipe for watering shall be provided in slanting manner.
M & L as in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 6 Sqmm multi stranded copper conductor drawn through existing conduit/ casing and capping with and including PVC FRLS insulated 6 Sqmm multi stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge.Notes : 1 PVC casing capping/ conduit, if required extra, shall be measured separately under relevant item. 2. PVC cables two single core and one single core of sizes as mentioned will considered as one unit.
M & L as in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 4 Sqmm multi stranded copper conductor drawn through existing conduit/ casing and capping with and including PVC FRLS insulated 4 Sqmm multi stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge. Notes : 1 PVC casing capping/ conduit, if required extra, shall be measured separately under relevant item. 2. PVC cables two single core and one single core of sizes as mentioned will considered as one unit.
M & L as in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 10 Sqmm multi stranded copper conductor drawn through existing conduit/ casing and capping with and including PVC FRLS insulated 10 Sqmm multi stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge.Notes : 1 PVC casing capping/ conduit, if required extra, shall be measured separately under relevant item. 2. PVC cables two single core and one single core of sizes as mentioned will considered as one unit.
Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4 core,Complete all as spd and directed.Make: Havells/Paragon/Finolex
Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 4 core,Complete all as spd and directed.Make: Havells/Paragon/Finolex
S&F Batten type LED light fitting 1x18/20 Watt 4 feet long including LED tube driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior fininsh and without any cracks or through holes. The system wattage of fitting should not be more than 18 watt = 10%, surge protectionof minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Colrelated colour should be minimum 6000 degree Kelvin complete all as specified and directed by Engineer - in – Charge. Make : Havells/C&S/Philips
M&L for LED 10W bulkhead fitting with IP-65 engineering plastic housing eith clear, single phase 240V, including 1.0 sqmm copper flexible cable twisted three core alongwith flexible PVC condiut from ceiling rose to fitting testing complete all as specified and directed by Engineer - in – Charge. Make : C&S/Bajaj cat part No BIBWP 10W LED/Havells/Philips
S&F LED Mirroe Tube light of 1X09/12 W 1 or 2 feet long complete all as specified and directed by Engineer - in – Charge. Make : Havells/Bajaj/Philips
S&F Rigid non-metallic PVC conduit of external dia 20mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engg-in-Charge.
S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed by Engg-in- Charge.
S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175 x 100 x 50 mm deep complete all as specified and directed by Engg-in- Charge.
S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 200 x 150 x 50 mm deep complete all as specified and directed by Engg-in- Charge.
S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 250 x 200 x 50 mm deep complete all as specified and directed by Engg-in- Charge.
S&F of LED Bulb of 7W complete all as specified and directed by Engineer - in – Charge.
S&F of LED Bulb of 9W complete all as specified and directed by Engineer - in – Charge.
S&F of LED Bulb of 12W complete all as specified and directed by Engineer - in – Charge.
M&L surface mountaed LED down light 36 W (2" x 2") luminaries to enhance the delight of occupants with classic design & glare free soft illumination with optimized heat sink for effcient heat dissipation complete with and including three core flxible wire for connection complete all as specified and directed by Engineer - in – Charge. Make : Bajaj cat part No BZSSQL 36W LED WH/Havells/Cromption
ROYAL BUILDERS
KATARIA CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .