Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.4 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹44.2 L+₹1.5 L (3.61%)Rejected-AOC | L2 | Rejected-AOC Rejected |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
22 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Provn of Ploughing and Certain repairs/maint works at LBT PBT Four Line area at KK Range AF under AGE B/R II at GE (N) Ahmednagar
2023_MES_590992_1
8731 / E8
Open Tender
Miscellaneous Works
Item Rate
335 days
Garrison Engineer North Ahmednagar
Class D Cat a(i)
8 documents required · 8 mandatory
₹500
Garrison Engineer(North) Ahmednagar
₹96,000
Yes
1 Jul 2023
24 Apr 2023
24 May 2023
24 Apr 2023
22 May 2023
8 May 2023
Amount
Demolition of brickwork or stone bouilder masonary built in cement mortar or lime mortar complete all as specified
M&L for Walling of random rubble,uncoursed well bonded, bedded and solidly hearted built in CM 1:6 complete all as specified
M&L for brickwork with fly ash bricks straight or curved on plan exc 6m mean radius,built in CM 1: 6 complete all as specified
Taking down cement mortar plaster on brick or stone walls, raking out joints, hacking for key complete all as directed
Chipping ,removing ,carefully Loose plaster by low impact Hammer without damaging the structure and cleaning and disposal of malba out side the MD land etc.
Clean existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. complete, Applying two coats of alkaline rust converting primer confirming to ASTM-B- 117, on the rebars, including cleaning the reinforcement,wirebrushing to remove loose rust spalls, with time interval of 1 hour between the coats.
Anticorrosive apoxy zinc primer to Reinforcement by Application of two coats on exposed reinforcement with time interval of minimum 4 hours between each coat. The application shall be by brush. Make: Dr Fixit, Fosroc or equivalent, Note:- mode of measurement superficial area of concrete will be measured.
M&L for rendering, 15 mm thick on stone/brick / concrete surfaces in cement mortar 1:6 including M S chiken wire mesh fixed with nails or screws for brick work or concrete surfaces of wall and ceiling finished even and fair without using extra cement complete all as specified and directed.
M&L for rendering, 10 mm thick on brick / concrete surfaces in cement mortar 1:6 surfaces finished even and smooth without using extra cement
M&L for rendering, 15 mm thick on stone/brick / concrete surfaces in cement mortar 1:4 finished even and fair without using extra cement complete all as specified and directed.
M & L for preparation of newly plastered surface of wall and apply two coats of OBD over a coat of primer complete all as directed.
M & L for preparation of new plastered surfaces of wall and applying two coats for cement based paint complete all as directed.
M & L for preparing old plastered surfaces of walls and apply one coat of OBD, finished with roller finish on plastered surfaces of wall etc complete all as specified and directed
M & L for preparation of old plastered surface of wall and applying one coats of cement base paint.
M & L for preparation of old wooden surface and applying one coat of synthetic enamel paint.
M & L for preparation of old steel surface and applying one coat of synthetic enamel paint.
M&L for preparation of old plastered or unplastered surfaces of walls including cornices etc by brooming down or steel wire brushing scraping down smook soot, moulds, moss and efflorescent salt, trading oil and greasy spots and applying one coat of white lime wash at any height including scaffholding etc complete all as specified and directed by Engineer-in-charge.
All as per item No 17 (here-in-before) but on ceiling.
M&L for preparation of old plastered treated surfaces of walls by brooming down and and applying one coat of weather proof 100 % acrylic exterior emulsion apex ultima paint of any tint as approved by GE after cleaning the surfaces complete all as specified and as directed.
M&L for 2 mm thick wall care putty etc complete all as specified and directed
S&F fix in repairs wash hand basin vitreous China white , flat back or angle type of size 500 X 400 mm incl pillar tap 15mm dia CP, waste chain and plug and porcelain stopper , waste pipe, a pair of brackets, or erecting stand and PVC connection etc complete all as specified and directed by Engineer-in-Charge
S&F in repairs vitreous China white squatting pan, Orissa pattern of size 580 X 440 mm width with integral foot rest set in cement concrete including flush pipe and connecting to trap / flushing cistern etc complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 10 ltr capacity PVC valve less, symphonic action type, flushing cistern, low level, all accessories etc complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, chromium plated shower rose with shower arm etc complete all as specified and directed by Engineer-in-Charge.
S&F in repairs vitreous china wash down water closet (Pedestal pattern) white including fixing bolts with and including plastic water closet seat cover closed pattern with flat bottom and cover and MSCP almn hinges device etc complete all as specified and directed by Engineer-in-Charge connecting to 'P' or 'S' trap etc complete all as specified and directed by Engineer-in-Charge.
S&F in repairs looking mirror of size 800 mm X600 mm, etc complete all as specified and directed by Engineer-in-Charge
M&L for 32 mm Mild steel Chromium plated curtain rods with end brakets and fixing stand/globe of choice, of same material, haevy duty all as directed by engineer in charge
Taking up or down 15 mm bore steel tubing and connections
Ditto all as per item No 28 above but 20 mm bore tubing
Ditto all as per item No 28 above but 25 mm bore tubing
Supplying and laying 16 mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings complete all as specified.
Ditto all as per item No 31 above but 20 mm bore tubing
Ditto all as per item No 31 above but 25 mm bore tubing
S & F in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified.
S&F in repairs stop cock/ anglecock/ two waycock cast copper alloy, Chromium plated fancy type screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fix of size 15 mm bore etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in repairs tubular towel rail, brass chromium plated 20 mm dia `D' type, 60 cm long between flanges including a pair of brackets all as directed.
M&L for Towel Ring of CP fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms)
S&F in repairs bib tap, 15 mm dia, CP cast copper alloy with crutch or butterfly handle screwed down for iron pipe or for brass ferrule etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair PTMT bib tap 15 mm dia, screwed for iron pipe complete all as specified and directed (Minimum weight for 15 mm 90 gms) make :- Prayag or equivalent.
S&F in repairs 15 mm dia pillar tap, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe all as directed.
Taking down chowkhats or frames not exc. 1.5 Sqm each with shutters (without taking off shutters from the frames) etc complete all as specified and directed by Engineer-in-Charge
Taking down chowkhats or frames exc. 1.5 sq. m and n exc 4.00 Sqm each with shutters (without taking off shutters from the frames) etc complete all as specified and directed by Engineer-in-Charge
Taking down shutters of any description exc 1 Sqm but exc 2 Sqm each etc complete all as specified and directed by Engineer-in-Charge
S&F 35 mm thick IInd C/L H/W glazed & skeleton shutters open rebated and prepared to receive glass gauge, divided into square or rectangles with plain chamfered or rounded mitered & rebated slash bars including beads mitered for securing glass wire gauge etc all as specified
M&L for 35 mm thick plain framed, paneled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial plywood. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated
S&F 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides
Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded
S & F Pressed steel door frame of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hings, lock strike plate, etc, complete all as specified,
S & F pressed steel door frame of size 100 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified,
M & L for preparation of new wooden surface and applying two coats of synthetic enamel paint over a coat of pink primer complete all as directed.
S&F Solid PVC Door frame size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing
S&F factory made solid PVC moulded Door shutter with particle board core, 28 to 30mm thick (stiles) with 2,4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back space, supplying and fixing in frame at site as per specification & drawing.
S&F butt hinges medium weight cold rolled mils steel 100mm long.
S&F aluminium anodised barrel tower bolts of extruded section 150mm long.
S&F aluminium anodised handle of extruded section 150mm long.
S&F aluminium alloy, anodised, sliding door bolt with hasp, staple and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy 300mm long.
S&F 300 mm mild steel ordinary rat tail rod pattern door spring including roller and roller plate complete all as specified and directed.
S & F in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40 mm and fixed in any position any type of opening with and including wooden beads complete all as directed by Engr-in-Charge.
S & F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40 mm and fixed in any position any type of opening with and including wooden beads complete all as directed by Engr-in-Charge.
M & L for 3 mm thick sheet frosted/pin headed glass ordinary quality and glazing with oil putty or wooden beads in squares n.exc 0.50 sqm in each pane.
M & L in repairs for 3 mm thick sheet frosted/pin headed glass ordinary quality and glazing with oil putty or wooden beads in squares n.exc 0.50 sqm in each pane including hacking out.
M & L in repairs for 4 mm thick plain sheet glass ordinary quality and glazing with oil putty or wooden beads in squares n.exc 0.50 sqm in each pane including hacking out..
M & L in repairs for 3 mm thick plain sheet fibre glass ordinary quality and glazing with oil putty or wooden beads in squares n.exc 0.50 sqm in each pane including hacking out..
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 500 litres capacity, triple layered, hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe, tank nipple and connected complete all as directed.
S&F in repair 20mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball and high density plastic ball screwed to iron pipe, tank nipple and connected (Minimum weight 15mm-142Gms/20mm-210Gms) complete all as directed.
Material and labour for sun dried brick work in mud mortar including removing the mud debris of old target out of target area complete all as specified and as directed.
Material and labour for mud plastering, 25 mm thick on walls / floors wherever required complete all as specified and as directed.
Cross ploughing over areas, ranging from 20 to 30 cms deep including removing of shrubs, roots, bushes upto 15cm girth picking up stones exceeding 1" in overall size coming up while ploughing and removing the shrub, bushes, roots , stones etc. to a distance exceeding 200 m and not exceeding 250 m complete all as specified and as directed.
Filling in depression formed in the area during exercise of rocketing and gunnery and levelling the surfaces to match with the adjoining surface all as specified and as directed . Note :- 1)The soil shall not be digged from outside MD land and the soil spread from adjoining area to be collected, filled and levelled as directed, Crusher dust shall also be provided to fill the depression of bombings wherever found necessary to make the surface even, the crusher sand wherever required shall be paid separately, complete all as per specified and directed by Engineer in charge ii) The stones/pebbles poped out during the bombing shall be collected and to be filled in deep pits formed during the bombing, durig the filling of the same. iii) Mode of measurement will be plan area of the depression formed (Item No a,b,c)
a) Depth upto 1.5 mtr
b) Depth 1.5 mtr to 3.00 mtr
b) Depth 3.00 mtr to 4.50 mtr
Supply and laying bamboos / ballies 6.5 m in length, dia not less than 8 cms at one end and not less than 6cm at other end complete all as specfied and as directed.
Cutting the bushes / vegetation / shrubs / thorny plants / trees of any type and not exc 30 cm in girth including roots growing up in the line of sight from watch tower to gunnery area and watch tower to target area and removing to a distance exceeding 150 m but not exceeding 200 m from the area and disposed off complete all as specified and as directed.
Supply only Sand filling in floor or paving laid in layer not exc 15cm thick spread, levelled and rammmed including watering etc complete all as specified and directed.
Supply only empty polypropylene bags white in colour of 50 kg (1.25 cft) capacity, which is generally used for storing cement.
Supply of crushed stone sand including filling in empty polypropylene bags and placed in circle wise position of required size and shape including stitching of polypropylene bag complete all asspecified and directed.
M&L for preparation of old plastered or unplastered surfaces of walls including cornices etc by brooming down or steel wire brushing scraping down smook soot, moulds, moss and efflorescent salt, trading oil and greasy spots and applying two coat of white lime wash at any height including scaffholding etc complete all as specified and directed by Engineer-in-charge.
Dismantling carefully the existing LT overhead line ACSR conductor of any size from its position by necessary disconnecting of conductor and removing complete all as specified and as directed
Dismantling of unserviceable insulator of any type complete from its position and removing all as specified and as directed
Dismantling of unserviceable existing cross arms made from channels, angles and unserviceable FI clamps, nuts, bolts etc from OH line and removing complete all as specified and as directed
Dismantling of existing LT poles carefully of any size and type from its position carefully and removing from the site and necessary excavation and earth work in any type of strata, demolition of concrete, disconnecting of conductor etc all as specified and as directed .
S&F stay assembly complete with accessories as shown in Electrical Plate No 1 of SSR 2009 (Part I) using stay rod 20mm dia, including clamps made out of 50 x 6mm MS flat, MS galvansied stay plate 300mmx 300mm x 6mm and galvanised thimble including insulator 90x140mm all as specified and as directed. (loop type insulator, stay clamps, excavation and concrete shall be measured and paid separately
M&L for prunning and removing of tree branches touching to electric over head lines wild growth around LT /HT over head lines and around pole and stay complete to make clear span of 2 Mtr of tree both side of the OH line with JCB, Cutter and all tools, plants etc all as directed by Engineer-in-Charge. Note : (i) Distance between pole to pole will be measured and paid. (ii) Contractor has to take upmost care to avoid damage to existing lines/structures if Any breakdown of line caused during punning shall be made good without any extra cost. (ii) Prunning of tree to be done twice a year (before & after rainy season) (iii) The contractor has to ensure the proper safety of the tradesmans to avoid any mishappening. If any mishappening occures the contractor will be solely responsible for it.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers etc welding bending cold or hot, drilling holes for bolts , in any shape or size as indicated or directed and inclusive of one coat of red oxide primer, one under coat and one inishing coat of aluminium paint all as specified and as directed.
M & L for replacement of Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade
M & L for replacement of shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers,insulator bolts, washers and nuts, 100mm height and 115mm dia including two nos of galvanised steel strap of size 31x5mm fitted with 14mm dia bolts and nuts all as per directed.
Labour for restringing of LT over head line consisting of 4/5/6 conductors retrive from ser item no-01 by dismantling taking down,unserviceable , damged ACSR conductor, repairing wherever required including cutting, re-joining and restringing in, with proper sag, binding to insulator with and including aluminium binding wire complete all as specified and directed. Note : (i) Only good and serviceable conductors are used, unserviceable conductors will be credited to contractor under schedule of credit. (ii) Rate of Transporting of conductor from one site to another site is included this rate.
Supply, fixing and stringing ACSR conductor (Weasel/ Ferret) for over head line securing on pole complete including binding wire, jointing sleeves aluminium tap and PG clamp etc of any size all as specified and as directed. (Note :- (a)jumper on cutout point/2 pole structer/4 pole structure shall be provided with PVC insulated sleeve. (b) Rate is inclusive of jumpers materials & tree branch cutting to make a safe distance from over head line.)
Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on soft/ lose soil and added additional 1.5 m or part thereof in depth beyond the first 1.5 mtr.
All as per ser item no 90 above but hard/ dense soil
Returning, filling in, including spreading , levelling , watering and well ramming in layers not exc 25cm of any soil.
Removing excavated materials(soils) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point.
Supply & lay HDPE pipe 63 mm bore for laying of LT cables etc complete with all accessores all as specified and directed
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:-
(a) 50 Sqmm 31/2 core, Make: Polycab/CCI/Havells
(b) 95 Sqmm 31/2 core, Make: Polycab/CCI/Havells
(c)120 Sqmm 31/2 core, Make: Polycab/CCI/Havells
M/L for GI pipe light grade 100 mm dia Tubes, with all fitting and fixed complete to walls and ceilings or laid in floors complete for protection of cables
M & L for making good the damaged Tar Road by using additional stone metal, PCC etc
Demolation of u/s cement concrete in coppings all as directed.
M&L cement concrete (1:3:6 ) type C2 using graded stone aggregate as in Copping of pole including demolation of existing damagable cooping necessary form work all as specified & directed.
Taking out Old existing security leight (HPSV/Tube light fitting) and Supply and fix in replacement of LED Street light Luminaries 45 watt, with inbuilt surge protection 10 KV, Lumans output 4500 with pressure die-cast aluminium housing with toughtened glass & IP 66 protection and impact resistance IK07 fixed with suitable size of GI Bracket of length 1.2 Mtr,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box to streeght light and 4 sqmm 3 core aluminium service cable pvc insulated 2.5 RM per fitting where over head line existing for connection of street light to over head conductor complete all as specified and directed. Make : Philips /Havells/Bajaj/Surya
Supply only in replacemet LED Drivers for 60/65 watt LED Fittings any type and any make as per sample.
Supply only in replacemet LED surg protectors for 45/60 watt LED Fittings any type and any make as per sample.
Supply and replacement of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension GI wire, twin core cable flat or circular with size 10 sqmm.
Supply and fix in replacement of timer switch Astronomical, 240volt, 50/60 Hz 16 amp/250VAC resistive of Make : L&T , Indoassian and standard.
Supply, fix in replacement of Contactor 3 pole AC -1 40 Amps Main Pole Confugration 2 No 2 NC 415 volt fixing with Existing Box by suitable size of copper cable with suitable size of lugs. make L&T Cat Part No-SS90701 or equivalent in Indoasian and C&J.
Supply only three pole contactor coil suitable for L&T contactor,240V,50 Hz cat part No CS94980/CS94105 or as per existing on site. Make: L&T
Lifting the Highmast pole 16 mtr height by crane from its own location with opening the nut boltt and washers , greasing the steel wire rope and fixing with pulley and reassembling and refixing at its orginal location, including reconnections and testing commissioning complete for smooth operations all as specified and directed. Note: (i) Rate for Crane and labours is being to be includes in Quoted rates. (ii) Rate of sundry items like grease, cotton waste, nut , bolt and washers are deemed to be quoted rates.
M & L for repair of LT Panel board of any size with replacing the unserviceable MCCB,MCB,switch fuse unit , change over ,Busbar,etc jointig cable with proper lugs ,nut , bolt and washers, cleaning the panel by using of CRC Soluation and repairing thhe panel door by using hinges and repairing the lock system, welding etc painting the LT Panel wit one coat of primer & two coat of synthetic enamel paint as approved or as per direction of Engr-in-Charge. Note:(i) MCCB,MCB,Switch fuse unit and change over switch measured and paid separately. (ii) Labour for MCCB, MCB, Switch fuse unit and change over switch measured and paid separately. (iii)Rate of new Busbar, lugs,CRC Solution,nut,bolt, painting etc and washers are deemed to be included in quoted rates.
Supply and fixing in replacement of MCB TPN 63 Amps with breaking cap 16 KA and connecting all as directed . Make : Legrand / L&T/Siemens.
Supply and fixing in replacement of MCB DP, 40 Amps with 10 KA breaking / rupturing capacity including neccssary connection complete all as directed. MAKE: Legrand/ L&T/Siemens.
Supply and fix in for replacement rewirable switch fuse unit,of sheet metal , triple pole and neutral, 415 Volts grade, 63 Amps capcity including neccssary connection with suitable size of copper cable complete all as directed. MAKE: L&T/Legrands/Siemens.
All as Per item No 115 above but 100 Amps capacity. MAKE: L&T/Legrands/Siemens.
Supply and fixing in existing panel board for replacement MCCB, 4 Pole, 400 Amps , with breaking capacity 36 KA , fixed type(HBC Series),adjustable type thermal setting 70-100% and magnetic adjustable 5-10 times AC 415 volt ,50 HZ conforming to IEC:60947-II/IS:13947-II and connecting all as directed. MAKE: L&T/Siemens/legrand
All as per item No 117 here in above but 200 Amps 25 KA breaking capacity. MAKE: Legrand /L&T/Siemens.
All as per item No 117 here in before but 100 Amps 25 KA breaking capacity. MAKE: Legrand / L&T/Siemens.
M & L for replacement of existing Amp meter (0-300Amp) along with CTs from existing LT Panel of any size
M & L for replacement of existing Volt meter 0 to 600 volt , digital type from existing LT Panel of any size, Make" L&T, CG
Material and labour for spray painting the LT Steel tubular pole,11/9 mtr long with two coats of synthetic enamel paint including prepartion of surfaces,Scraping the old paint and writing pole No in Black letter under yellow circle all as directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to GI strip 32 x 6 mm , by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion complete all as specified and directed. Note:- i) Cost of GI strip 32 x 6 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii) Excavation and returning filling of Soil any type is deemed to be included in rates.
Supply and spreading in electrical outdoor installation yard, stone aggregate of size 20 mm at 11KV substations / Near DP structures after through cleaning, anti grass treatment etc all as per pecified and as directed.
Supply and spreading in electrical outdoor installation yard, stone aggregate of size 40 mm at 11KV substations / Near DP structures after through cleaning, anti grass treatment etc all as per pecified and as directed.
S&F in replacement of drop out fuse unit, explusion type for out door air break gang oprated switch, single pole mounted on and including insulators for 11 KV working pressure fixed to and including MS channel with nuts, bolts and washer etc synthetic bounded fuse tube complete with line capcity suitable for current carrying capacity upto 100 Amps all as directed including taking down old one all as specified and as directed
M&L Outdoor type bus bar LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos aluminium bus bar, of capacity 400 Amps fabricated in factory having modern fabrication facility duly powder coated painting, dust and vermin proof, degree of protection not less than IP-55, the panel shall be made out of 3.00mm thick CRCA mild steel sheet, front door (01 layer) and rear door (01 layer) opening facility and 4 side slanting canopy type roof on top and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level including installation, commissioning, testing and necessary PCC work Make: Supreme & Co Pvt Ltd Sanjay casting and Engineers, Mahalaxmi cable & Conductor.
Repair / Overhauling of air break switch by replacing stationary and moving contacts, flexible copper chord, GI nuts, bolts etc including alingment for smooth functioning from ground level all as required at site and all as specified & directed.
Supply & fix LT line seperator 3/4 lines made of high quantity PVC material to provide 300 mm distance between phase to phase and neutal or as per sit reuirement as directed by Engineer-in-charge
Repairs/rectification of GI Pipe leakage by replacing short piece length up to 0.50 mtr in wall/floors etc and excavation upto 1 cum as in trenches and including providing unions, reducers,nipples etc and making necessary connections to make it functional complete all as specified and as directed for following pipe of dia.
Taking up or down GI steel tubing and connections from trenches / walls / floors etc cleaning for re-fixing for following pipe of dia complete all as specified and as directed.
(a) 100mm bore
(b) 80mm bore
(c) 50mm bore
(d) 40mm bore
(e) 25mm bore
(f) 20mm bore
(g) 15mm bore
Supply and fix GI pipes, medium grade including necessary fittings such as sockets, elbows, tees, reducers, unions, nipples etc laid in trenches / walls / floors etc for following pipe of dia complete all a s specified and as directed. Make:- Tata/Swastik//Jindal
(a) 100mm bore
(b) 80mm bore
(c) 50mm bore
(d) 40mm bore
(e) 25mm bore
(f) 20mm bore
(g) 15mm bore
All as per serial item No 144 above but using old retrieved pipe from srl item No 6 with new GI fittings for following pipe of dia.
(a) 100mm bore
(b) 80mm bore
(c) 50mm bore
(d) 40mm bore
(e) 25mm bore
(f) 20mm bore
(g) 15mm bore
Material and labour in repairs gun metal gate valve/brass stop valve, high pressure both ends screwed down with crunch or butterfly handle with suitable size sockets on both ends nipples, unions, etc suitable for following GI pipe of dia complete all as specified and as directed. Make:- TATA/ZOLOTO/Leader
Taking up cast iron / ductile iron water mains with Spigot and socket ends having lead / tyton joints including all fittings and burning out joints, removing lead for following pipes of dia complete all as specified and as directed.
(a) 80 mm bore
(b) 100 mm bore
Supply and laying ductile iron pipes with flanges both end centrifugally K-9 , in any length, laid in trenches for following pipes of dia complete all as specified and as directed. Make:- Kesoram/Kalinga/Tisco/Electro steel NOTE: Flanges,nuts,bolts,washers included in rate Quoted. Tyton joints required are deemed to be included in the unit rate quoted.
(a) 80 mm bore
(b) 100 mm bore
All as per serial item No 169 above but using old retrieved pipe from srl item No 10 with new tyton joints of following pipes of dia.
(a) 80 mm bore
(b) 100 mm bore
Material and labour for cast iron / ductile iron specials such bends of any type, radius and angle, tapers any type, straight, bend, increasing, decreasing or double socket etc, tail pices single branch, "Y" junctions, double branch, cross (all sockets or socket and spigot) collars, caps and plugs etc suitable for CI / DI pipes class LA upto 300 mm more pipes complete all as specified and as directed.
Material and Labour for Run lead joint complete and pressure testing complete all as specified and directed or the following sizes:-
(a) 80 mm bore
(b) 100 mm bore
Material and labour for Caulking lead joints including run lead for arresting the leakages for following pipes of dia complete all as specified and as directed.
(a) 80 mm bore
(b) 100 mm bore
Supply and fixing in repairs mechanical joints, non extendable type with rings, nuts , bolts & washers etc for 80 mm bore CI / DI pipes complete all as specified and as directed.
(a) 80 mm bore
(b) 100 mm bore
Material and labour for opening of unserviceable sluice valves, cleaning the serviceable parts, adjusting of moving parts , greasing , re-assembling of valve and fixing to the desired position with and including replacement of rubber gaskets, nuts ,bolts, washers , gland packing,Brass Checknuts and SS Spindle suitable for following dia of sluice valve complete all as specified and as directed.
(a) 80 mm bore
(b) 100 mm bore
Supply and fix in repairs cast iron sluice valve , Class PN1, ISI marked with stainless steel spindle, both ends flanged including rubber gasket, nuts, bolts and washers complete all as specified and as directed for following pipes of dia Make :- Kirloskar/BIR/Upadhyay
(a) 80 mm bore
(b) 100 mm bore
Supply and fixing in repairs of graphite gland packing for sluice valve for following dia bore complete all as specified and as directed.
(a) 80 mm bore
(b) 100 mm bore
Dismantaling old valve chamber & M & L for Construction of PCC solid block valve chamber including earth work described as under complete all as specified for the following internal size as under : (a)100 mm thick hard core, (b)PCC foundation 1:4:8 type D2 (using 40 mm graded stone aggergate) (c) 200 mm thick block masonary graded C-5 built in CM 1:6, (d)15 mm internal and external plaster in CM 1:4, (e)3mm thick MS sheet chamber cover and 50 x 50 x 6 mm thick angle iron frame including painting with two coats of synthetic enamel paint over one coat of red oxide primer on all exposed surface including locking arrangments.
(a) Internal Dimension 1500 mm x 1100 mm x 1000 mm
S& F in repairs high pressure polythelene float valve with PVC ball suitale for fixing to GI pipe of 20 mm dia all as specified
Cutting cast iron / ductile iron pipes in position for taking out branch connection by inserting new tee etc for following bore pipe complete all as specified and as directed
(a) 80 mm bore
(b) 100 mm bore
Drilling and tapping cast iron / ductile iron water mains, in position, for branch connections of the internal dia 20 to 50 mm all as directed.
Supply & Fix, CI foot valve complete suitable as per existing of the 80 mm size including taking down old U/S all as specified & directed.
NOTE for item nos 79 to 202 :- (i) The contractor/his supervisor will report the office on 09.00 clock morning every day including any holidays to collect the complaints from JE and will render the completion within 12 hours failing which 500 Rupees per day will be charged as an penalty & the same will be recovered from contractor. (ii). The contractor and his supervisor will provide the mobile number so that they can be communicated about the complaints, the SMS will be sent on those mobile and will be treated as an official complaints. The contractor will render the completion in writing to the department within 12 hours hours failing which 500 Rupees per day charged as penalty .
An amount of Rs 22,326.00 shall be deducted from BOQ on account of schedule of credit
M/s.D.K.ALKUTE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .