The Executive Engineer, Kolkata Electrical Div
The Executive Engineer Kolkata Electrical Division P.W.Dte. BlockI (1st Floor) Writers Buildings, Kolkata 700 001
Temporary Electrical installation work in respect of Durga Puja Idol Immersion Ceremony 2025 at Red Road PART F PA system For ASL Programme and Working light.
2025_WBPWD_879406_1
WBPWD/EE-KED/eNIQ-16Q/25-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Maidan
Please refer Tender documents.
5 documents required · 5 mandatory
₹23,000
O/O The Executive Engineer Kolkata Electrical Divi
25 Sept 2025
16 Jul 2025
6 Aug 2025
16 Jul 2025
4 Aug 2025
29 Jul 2025
28 Jul 2025
Amount
Providing on hire basis 500V, 200A on load change over switch on angle iron frame erected on the ground / wall with necessary support incl. interconnection wiring,socketing, earthing arrangement & dismantling the same after completion of the program.(with PWD / E.I.C. approved materials) (Hiring upto 20 days)
Providing on hire basis 500V, 100 A on load change over switch on angle iron frame erected on the ground / wall with necessary support incl. interconnection wiring,socketing, earthing arrangement & dismantling the same after completion of the program.(with PWD / E.I.C. approved materials) (Hiring upto 20 days)
Providing on hire basis 415V, 200A TPN SFU in SS enclosure with Rewirable / HRC fuses on wooden plank board or suitable angle iron frame incl. Providing interconnection wiring with socketing, earthing attachment etc. and dismentaling at the of end function (with PWD / E.I.C.approved materials)(Hiring upto 20 days)
Providing on hire basis 415V, 100 A TPN SFU in SS enclosure with Rewirable / HRC fuses on wooden plank board or suitable angle iron frame incl. Providing interconnection wiring with socketing, earthing attachment etc. and dismentaling at the of end function (with PWD / E.I.C.approved materials)(Hiring upto 20 days)
Providing on hire basis 415V, bus bar chamber comprising of 4 nos. copper bars of 500 A capacity, fixed on angle iron frame including necessary interconnection wiring along with termination by socketing the cable/wire ends and 2 nos earthing attachment and dismantling the same after completion of the programme..(with PWD / E.I.C. approved materials)(Hiring upto 20 days)
Providing on hire basis 415V, bus bar chamber comprising of 4 nos. copper bars of 200 A capacity, fixed on angle iron frame including necessary interconnection wiring along with termination by socketing the cable/wire ends and 2 nos earthing attachment and dismantling the same after completion of the programme..(with PWD / E.I.C. approved materials)(Hiring upto 20 days)
Providing on hire basis 415V, Upto 8 Way 100 amp,VTPNDB With 100 amp MCCB As Incoming 8 No. - 63 amp FPMCB as Outgoing including necssary interconnection wiring in a outdoor type pillar box along with necessary termination by socketing the cable/wire ends including 2 nos earthing attachment and dismantling the same after completion of the programme.(with PWD / E.I.C. approved materials)(Hiring upto 20 days)
Providing on hire basis 415V, Upto 6 Way TPNBDB With 1 No. - 63 amp FPMCB as Incoming & 18 No. 6-32 amp SPMCB as Outgoing including necssary interconnection wiring in a outdoor type pillar box along with necessary termination by socketing the cable/wire ends including 2 nos earthing attachment and dismantling the same after completion of the programme.(with PWD / E.I.C. approved materials)(Hiring upto 20 days)
Providing on hire main wiring with 1.1 KV grade Aluminium Conductor PVC / XLPE armoured cable of following sizes including laying in trench (at least 230 mm below ground) including dismantling the same and mending good the damages.(Hiring upto 20 days)
4 core 16 sq mm
4 core 50 sq mm
Supplying & Drawing on Hire Basis following size single core PVC insulated, unsheathed, multistrand copper/Al wire including necessary termination by socketing the wire ends & dismantling the same after completion of the program.(with PWD / E.I.C. approved materials)(Hiring upto 20 days)
7/0.064(7/16) Single Core
7/0.036(7/20) single core
Providing and Fixing on hire basis following LED Flood light fittings complete with bracket & clamp on the pole incl. accessories and dismantling as directed by EIC after the programme(Hiring upto 20 days)
Minimum 200 Watt LED Flood fittings.(Crompon/Philips/Bajaj/Nordusk)
Supplying & providing on Hire basis 1 no Seperate 6 amp plug and Switch with 150X100X65mm MS/TW switch Board including necy. wiring in 3 x1.5 sq mm single core PVC insulated, unsheathed, multistrand copper wire (avg. Length 5 mtr) & dismantling the same after completion of the program.(Hiring upto 20 days)
Supplying & providing on Hire basis 1 no Seperate 20 amp plug and Switch with 150X100X65mm MS/TW switch Board including necy. wiring in 3 x2.5 sq mm single core PVC insulated, unsheathed, multistrand copper wire (avg. Length 5 mtr) & dismantling the same after completion of the program.(Hiring upto 20 days)
Supplying & providing on hire basis 1200mm sweep ceiling fan complete set with hanging arrangement incl.3 x 1.5 sqmm copper wire connection & dismantling the same after completion of the program.(Hiring upto 20 days)(PWD/EIC approved materials).
Supplying & providing on hire basis 40V A. C. 600 mm / 24" sweep Air Circulater Pedestal Fan with 3 pin plug top and dismantling the same(Hiring upto 20 days)
Supply & Providing Earthing on hire basis with 50 mm dia GI Pipe 2.5 to 3 mtrs. Long and 6/8 SWG GI wire with galvanized nuts and bolts washer etc. below ground level on hire basis and dismantling the same.(Hiring upto 20 days)
Supplying & providing on hire basis following items for 01 Day with carrying cost at the sites including necessary connecting cables.
Speaker box of 1000 Watt (make: Crown/Crest Audio/Equivalent of same spcification.
Power Amplifier system sufficient to speakers and microphones of approve make.The agency needs to provide the amplifiers as required at site. (make: Crown/Crest Audio/Equivalent of same spcification).
S & D Cordless Microphone(Make-Shure/Samson/Sennheiser/Equivalent of same spcification)
S & D Corded gooseneck Microphone (Make-Shure/Samson/Sennheiser/Equivalent of same spcification)
Deployment of 03 no. Skilled Technician & 03 no. Helper per shift per day (i.e. Total 9 nos Electrician & 9 nos Helper per day for 24 Hrs) for carring out all kind of EI maintenance ,DG operations including PA system & proper upkeepment and preventing any unwanted incidents like theft, willful damage etc. (no additional charge will be paid for any unwanted incidents)
Supplying & providing on hire basis CPCB approved following ratings soundless Diesel Generator Set (DG set Without diesel) with mobil including one operator, appropriate size of cable upto 120 Mtrs including necessary interconnection, socketing & dismantling as directed by EIC after the program.If the DGs are not placed at site on time, pro rata rate will be reduced from bill.
62.5 kVA 1 Set
25 kVA 1 Set
18 % GST on the total amount from item no 1 to 20.02.
Supply & Pouring of HSD for the hired DG set incl handling cost.(the measurement will be done after considering all technical aspect, original invoice & log book)
Special Terms and conditions for Temporary E.I. Work - 1) Earthing should conform to IS specification. Earth Continuity wire should not be broken / Jointed. Single Earth continuity wire should be used from Earth Bus-Bar to the installation. 2) All 3ɸ Electrical Panel Should be earthed by two nos. of separate earthing and 1ɸ panel should be earthed by one no earthing. 3) MCB / Rewirable Fuse type Distrubution Board should be installed with proper Trip Current setting / fuse wires. However, MCB type DBs are preferable. 4) No Part of the Electrical Circuit in the pandal / Structure shall be within 12 inches of any decorative cloth / paper. 5) Ordinary Flexible wires should not be used. Only new PVC insulated & sheathed wires (Bearing ISI mark) or PVC insulated wires of FRLS (Fire Resistant Low Smoke) type (ISI Marked) are allowed. 6) All cable ends should be properly socketed. 7) All joints shall be made with porcelain insulated connectors. Twisted & lapped joints shall be avoided. But Joints are strictly not allowed in the dias. 8) Cables / Wires should run along outside the Dias. 9) Ceiling fan (s) / Electrical fittings must not be suspended from the ceiling of Dias. Pedestal fans are not allowed on the Dias. However, Pedestal fans may be installed outside dias, but the body of the fan must be properly earthed.
10) T/L fittings shall be of box type (Indoor commercial type). Any kind of open type fittings must be avoided. 11) Each A.C. Machine should be connected with a separate circuit and earthing should be provided by separate single earth contunuity wire from Earth Bus-bar. 12) P.A. System and Microphone shoud be earthed. 13) Sufficient quantity of Fire Extinguishers and First Aid Box should be provided. 14) If the DGs are not placed at site on time pro rata rate will be reduced from bill. 15) The guarding /security arrangement of all the hired products /installation has to be made by the successful bidder at his/their own cost and responsibility. No additional charge will be paid for any unwanted incidents like theft, damage due to natural calamities or any other reasons whatsoever. 16) During entire hiring period any fault to the hired installation shall be rectified/faulty items replaced, at the cost of agency. Suitable man power for attending and rectification/replacement of damaged items has to be provided by the agency at their own cost. Rectification time is 1 hour for the event day and upto 2hrs for other days. 17) A test certificate cum safety certificate is to be provided by the agency, duly signed by the Supervisor of the agency after completion of installation. 18) A performance guarantee of hired DG sets and AC machines has to be provided by the agency after completion.
GHANASHYAM ELECTRIC STORES (BID ID -6801929)
SHREE GANESH ENTERPRISE (BID ID -6797192)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .