Executive Engineer MHCHD, Srinagar
Office of the Executive Engineer, MHCHD, Srinagar
Repairs, Maintenance and Servicing of VRV System installed at SPS Library, Srinagar.
2022_PWDJK_186764_1
MHCHD/TS /2022-23/91/e-tendering Dt02-09-2022
Open Tender
Repair and Maintenance Works
Item Wise
5 days
SPS Library MA Road Srinagar
As Detailed in NIT
4 documents required · 4 mandatory
₹500
Executive Engineer MHCHD, Srinagar
₹8,400
12 Sept 2022
2 Sept 2022
10 Sept 2022
2 Sept 2022
10 Sept 2022
3 Sept 2022
Amount
Wet Servicing of indoor units which invloves dismounting of PVC casing, filters etc followed by application of descaling compound on the evaporator coil to remove dirt debris entrappted in the said coil. The job further includes washing the evaporator coil with high speed water jet. The contractor will ensure that the flooring does not get damaged while carrying out the entire cleaning process.
Wet Servicing of oputdoor units of VRV Machines by way of applying descaling compound on the Condenser coil to remove dirt debris entrappted in the said coil. The job further includes washing the Condenser coil with high speed water jet. The entire cleaning process is to be carried out in such a way that no electric circuits/Compressor of the outdoor unit gets damaged.
Providing & Fitting of ELCB for VRV Outdoor units against the damaged ones
Providing & Fitting of New Compressor to 12 HP Outdoor unit by way of replacing old compressor of specification as recommendations of OEM.
Charging of R410 Refrigerant in the invidual refrigerant circuits for VRV system to ensure optimum performance of individual VRV outdoor units
Providing and Fitting of new PVC Drain pipe 32 mm dia from individual indoor units in each floor with proper slope and gradient to ensure hassle free discharge of condensate from indoor units to the nearest drain point.
NEW AHANGER ENGINEERING WORKS
ALPHA TECH ENGINEERS
M/S STAR NEOTECH ENGINEERS
AIRCON TRADERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .