Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 CrAccepted-AOC | ₹8.2 Cr | L1 | Accepted-AOC Being overall reasonable |
| 2 | L2₹8.3 Cr+₹3.1 L (0.38%)Rejected-Finance 20 SC BOSE COLONY GALL NO 2 DEFENCE LAB ROAD RATNADA JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹8.3 Cr+₹3.1 L (0.38%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹8.4 Cr+₹11.5 L (1.40%)Rejected-Finance 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹8.4 Cr+₹11.5 L (1.40%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹8.7 Cr+₹42.0 L (5.10%)Rejected-Finance 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹8.7 Cr+₹42.0 L (5.10%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹9.3 Cr+₹1.0 Cr (12.7%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹9.3 Cr+₹1.0 Cr (12.7%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹9.1 Cr
EMD Value
₹7.8 L
Closing Date
29 Nov 2024, 6:00 pmClosed
Chief Engineer Jabalpur Zone
HQ Chief Engineer Jabalpur Zone Ridge Road Jabalpur Cantt 482001
AUGMENTATION OF ELECTRIC SUPPLY UNDER GE WEST JABALPUR
2024_MES_681197_1
752930A
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
JABALPUR
AS PER NIT
8 documents required · 8 mandatory
₹3,000
GE WEST JABALPUR
₹7.8 L
Yes
7 Feb 2025
25 Oct 2024
6 Dec 2024
25 Oct 2024
29 Nov 2024
22 Nov 2024
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | SCHEDULE "A" : | - | - | - | - |
| 3 | Item No 1: Dismantling existing ACSR (any size) from over head line complete all as directed by Engr-in-Charge. | 22 | Per Qtl | - | - |
| 4 | Item No 2: Dismantling insulators any type and any size complete all as directed by Engr-in-Charge. | 360 | Each | - | - |
| 5 | Item No 3: Dismantling of cross arm(made of MS channels / angles etc.) or clamps etc.complete and stacking aside for re-use / replacement all as directed by Engr-in-Charge | 14 | Per Qtl | - | - |
| 6 | Item No 4: Dismantling of stay assembly embedded in concrete and removing materials from site of work complete all as directed by Engineer-in-Charge. | 30 | Per set | - | - |
| 7 | Item No 5: Dismantling of old unserviceable service connection cable with GI wire and reel insulator complete all as directed by Engr-in-Charge. | 1,500 | RM | - | - |
| 8 | Item No 6: Dismantling of existing GI earth wire any size complete all as specified and directed | 9 | Per Qtl | - | - |
| 9 | Item No 7: Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X6 MM mm strip by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : -
(a) Excavation and earth work for drilling hole for electrode in any type of Soil.
(b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter.
(c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed
(d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed.
(e) Requisite quantity of common salt and charcoal.
(f) Testing of earthing. | 110 | Each | - | - |
| 10 | Item No 8: Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : -
(a) Excavation and earth work for drilling hole for electrode in any type of Soil.
(b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter.
(c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed
(d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed.
(e) Requisite quantity of common salt and charcoal.
(f) Testing of earthing. | 20 | RM | - | - |
| 11 | Item No 9:Taking down of old unserviceable cable of any type upto and including 50 sqmm complete all as specified and directed | 1,000 | RM | - | - |
tech_bid_open
tech_eval
fin_bid_open
boq_comp_chart
xlsx
fin_eval
aoc
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
BOQ.xls
BOQ • 0.61 MB
Tenderdocument.pdf
Tender Documents • 1.68 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .