Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹19.2 LAccepted-AOC NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹21.3 L+₹81,175 (3.96%)Rejected-Finance KE 100 B KAVERI KUNJ PHASE I KAMLA NAGAR AGRA 282005 | AGRA | AGRA | UTTAR PRADESH | 282005 | L-2 | Rejected-Finance Being other than lowest. | |
| 3 | L-3₹22.1 L+₹1.6 L (7.60%)Rejected-Finance | L-3 | Rejected-Finance Being other than lowest. | |
| 4 | L-4₹22.1 L+₹1.6 L (7.83%)Rejected-Finance | L-4 | Rejected-Finance Being other than lowest. | |
| 5 | L-5₹23.4 L+₹2.9 L (14.3%)Rejected-Finance 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L-5 | Rejected-Finance Being other than lowest. |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
4 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GEADADMAREAAGRA
GEADADMAREAAGRA
REPAIR AND MAINT TO EXTERNAL SECURITY LIGHT BUS BAR BOXES AND OTHER CONNECTED WORKS IN 4 AREA UNDER GE AF ADM AREA AGRA
2020_MES_361126_1
8000-1812/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GEADADMAREAAGRA
Class D Cat b ( i ) and for un enlisted firms docs as per NIT
8 documents required · 8 mandatory
₹500
GEADADMAREAAGRA
₹60,000
Yes
8 Sept 2020
15 Jul 2020
6 Aug 2020
15 Jul 2020
4 Aug 2020
23 Jul 2020
60 days
Amount
Taking down street light fitting of any type, any wattage from street tubular/ PCC poles / High mast poles of any height including disconnection of electrical connections and repair the same complete in all respect, refixing and reconnection at existing/ new position all as directed. Note : All U/S parts/ accessories shall be replaced and paid under respective items of BOQ as "Supply only".
Supply only driver suitable for LED light fitting 15 to 30 Watt. Make : Crompton / Havells/ Philips.
Supply only driver suitable for LED light fitting 45/ 60 Watt. Make : Crompton / Havells / Philips.
Supply only driver suitable for LED light fitting 90/ 120 Watt. Make : Crompton / Havells / Philips.
Supply only PCB card suitable for LED light fitting 15 to 30 Watt. Make : Crompton / Havells / Philips.
Supply only PCB card suitable for LED light fitting 45/ 60 Watt. Make : Crompton / Havells / Philips.
Supply only PCB card suitable for LED light fitting 90/ 120 Watt. Make : Crompton / Havells / Philips.
M&Lfor replacement of existing U/S street light fitting with LED street light fitting 45 Watts, IP 66, having pressure die cast aluminium alloy housing with heat resistant toughned glass with individual LED lenses and driver shall be IP-67 for water protection, including surge protection device 5 KV including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 2.5 sqmm complete all as specified and directed. Make: Havells Cat Ref ENDURAPEARLNEOSL45WLED757PASYTOPC/ Philips Cat Ref BRP409 LED 040 CW HO MR FG S1 PSU GR/ Wipro Cat No: LR02-501-XXX-57-XX
M&L for replacement of existing U/S street light fitting with LED street light fitting 60 Watts, IP 66, having pressure die cast aluminium alloy housing with heat resistant toughned glass with individual LED lenses and driver shall be IP-67 for water protection, including surge protection device 5 KV including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 2.5 sqmm complete all as specified and directed. Make: Havells Cat Ref ENDURAPEARLNEOSL60WLED757PASYTOPC/ Philips Cat Ref BRP409 LED 060 CW HE NR PC S1 PSU GR/ Wipro Cat No :LR02-671-XXX-57 G2.
M&L for replacement of existing U/S street light fitting with LED street light fitting 90 Watts, IP 66, having pressure die cast aluminium alloy housing with heat resistant toughned glass with individual LED lenses and driver shall be IP-67 for water protection, having surge protection device 10 KV, including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 2.5 sqmm complete all as specified and directed. Make: Havells Cat Ref ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO/ Philips Cat Ref BRP410 LED 091 CW HE MR PC S2 PSU GR/ Wipro Cat No:LR02-102-XXX-57-G2.P
M&L in replacement U/S GI bracket made out of GI pipe 40 mm bore medium grade bent to required shape of 0.90 mtr long and fixing to pole/ wall with suitable size of nut, bolts and clamps complete all as specified and directed. Note :- Taking down and re-fixing of street light shall be the part of this item.
S&F in replacement post top lantern 35 Watts, 230 volts, 50 Hz with IP 65 protection, mushroom or oval shaped in opal/ prismatic finish made out of polycarbonate, suitable all accessories and prewired complete all as specified and directed. Make:- Havells Cat Ref RUBYPT35WLED830PSYMTOPC/ Wipro Cat Ref LP07-431-XXX-57-CL or equivalent in Philips.
S&F in replacement LED bollard of 9/ 10 watts, 230 volts, 50 Hz with IP 65 protection with robust design and efficient light distribution complete all as specified and directed. Make:- Havells Cat Ref MOUNTBL 10WLED857PSUMTOPMMA(0.6M)/ Wipro Cat Ref LB14-131-XXX-65-05/ Philips Cat Ref BCP400 LED09 D CW PSU GR S1
M&L for replacement of existing U/S street light fittings with LED flood light fitting 120 Watts, IP 66, having pressure die cast aluminium alloy housing with heat resistant toughned glass with individual LED lenses, having surge protection device 10 KV and driver shall be IP-67 for water protection, including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 2.5 sqmm complete all as specified and directed. Make: Havells Cat Ref JETAIRISFLS120WLED757APNBLTG/ Philips Cat Ref BVP192 LED110 CW HO NB FG GR PSU/ Wipro Cat Ref LF20-132-060-57-G2
M&L for replacement of existing U/S street light fitting with LED flood light fitting 150 Watts, IP 66, having pressure die cast aluminium alloy housing with heat resistant toughned glass with individual LED lenses, having surge protection device 10 KV and driver shall be IP-67 for water protection, including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 2.5 sqmm complete all as specified and directed. Make: Havells Cat Ref JETAIRISFLS150WLED757PSYMLTG/ Philips Cat Ref BVP122 LED150 CW HE NB FG XTFCL S4/ Wipro Cat Ref LF20-192-060-57-G2
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables including getting out in soft/ loose soil complete all as specified and directed.
Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm each layer with excavated soil complete all as specified and directed.
Removing surplus excavated soil from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for local sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable and punned down complete all as specified and directed. Note : Only punned thickness shall be measured for payment purpose.
M&L for old size brick well burnt, laid flat for cable protection complete all as specified and directed.
Re-laying of old serviceable bricks for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable complete all as specified and directed.
Taking out old unserviceable LT UG cables of size 10 to 70 sq mm, 2/ 3.5/ 4 core from trenches, poles/ walls and floor for removing of fault or re-laying (Necessary earth work shall be measured and paid under respective item of sch.) complete all as specified and directed.
Re-Laying XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 10 to 70 sqmm, 3.5/ 4 core laid in trenches or fixed on wall/ floor/ poles after removing fault complete all as specified and directed.
Supply and Laying of exsting U/S XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 50 sqmm, 3.5 core in trenches or fixed on wall/ floor/ poles complete all as specified and directed.
Supply and Laying of exsting U/S XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 35 sqmm, 3.5 core in trenches or fixed on wall/ floor/ poles complete all as specified and directed.
Supply and Laying of exsting U/S XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 25 sqmm, 3.5 core in trenches or fixed on wall/ floor/ poles complete all as specified and directed.
Supply and Laying of exsting U/S XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 16 sqmm, 4 core in trenches or fixed on wall/ floor/ poles complete all as specified and directed.
Supply and Laying of exsting U/S XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 10 sqmm, 2 core in trenches or fixed on wall/ floor/ poles complete all as specified and directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
M&L for replacement of old unserviceable/ under size ACSR conductor squirrel to dog (6/1/2.11 to 6/1/4.72) any size drawn straight horizontal on over head lines on existing poles including binding with insulators. Weight of conductor shall be measured straight horizontal distance between centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag, jointing jumpers, etc complete all as specified and directed.
M&L for galvanized iron steel wire drawn straight horizontal as continuous earth wire on existing LT poles of size 4.0 mm dia complete all as specified and directed.
M&L for replacement of shackle type porcelain vitreous, white brown or green insulator for working pressure 1.1 KV of size 100 mm height and 115 mm dia including galvanized mild steel straps of section 38 x 5 mm size, 20 mm dia bolt, nut and washers complete all as specified and directed.
S&F in replacement 1100 volts grade heavy duty PVC insulated aluminium conductor, served with inner sheathing of PVC in service connections suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire one twin core cable of size 16 sqmm multistrand complete all as specified and directed.
M&L for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor, along the wall or along the pole complete all as specified and directed.
M&L for replacement of GI tubing light grade 50 mm bore for passing through cables under the floor, along the wall or along the pole complete all as specified and directed.
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 31), 09 meter long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint including taking out old U/S pole complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 ( using 40mm graded stone aggregate) as in foundation ,filling and mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 ( using 40mm graded stone aggregate) as in foundation of stays or coping of poles complete all as specified and directed.
Trimming up of tree branches upto 3 mtr all around LT overhead lines, removing cut branches from site as directed. Note :- (i) The overhead lines will be kept clear from all trees by trimming of tree branches with 3 mtr all around the line. Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department.
M&L for cable end termination in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 50 sqmm to 95 sqmm 3½ core with working voltage 1100 volts complete all as specified and directed. Make:- Denson/ Raychem/ M-seal.
M&L for cable end termination in door/ out door, heat shrinkable type suitable for XLPE/ PVC cables of size 16 sqmm to 35 sqmm 3½ core with working voltage 1100 volts complete all as specified and directed. Make:- Denson/ Raychem/ M-seal.
M&L for cable end termination in door/ out door, heat shrinkable type suitable for XLPE/ PVC cables of size 10 sqmm, 2 core with working voltage 1100 volts complete all as specified and directed. Make:- Denson/ Raychem/ M-seal.
M&L for prepration of old painted surface of steel tubular poles of 9 mtr long including cross arms , cable protection pipe , bus bar box and painting of complete area with one coat of aluminum paint from 1.5 mtr above ground level to top of pole and a height of 1.5 mtr from the ground level synethetic enamel paint in alternate strips / layer (30 cm wide) with white and blue colour including writing the pole number in white letters on black background and cleaning/ cutting the grass/ bushes at a radius of 2 mtr surrounding the pole complete all as specified and directed.
M&L for stay assembly complete with all acessories using GI stay rod 20 mm dia complete with stay plate mild steel of size 300 mm x 300 mm x 6 mm thick, stay bow complete all as specified and shown in Electrical Plate No 1. including necessary earth work and stay strand, loop insulator and clamps.(PCC shall be measured and paid seperately) complete all as specified and directed.
M&L in replacement of existing U/S MCCB 160 Amps current carrying capacity 36 KA , AC 415 Volts four pole with magnetic/ thermal fixed setting complete all as specified and directed. Make Legrand/ Seimens/ Schenieder.
M&L in replacement of existing U/S MCCB 125 Amps current carrying capacity 36 KA , AC 415 Volts four pole with magnetic/ thermal fixed setting complete all as specified and directed. Make Legrand/ Seimens/ Schenieder.
Supply and fixing in replacement of existing old un-serviceable fixed type MCCB with MCCB 63 Amps, 4 pole, 415 volts, 16 KA complete all as specified and directed. Make : Legrand/ Seimens/ Schenieder.
Supply and fixing in replacment of nature switch complete with timer , contactor, relays and suitable rating MCBs for incoming and out going in built in suitable IP 66 enclosure (Hensel) of three phase integrated models of capacity 8 KW complete all as specified and directed. Make : Cat Part No. SWADEEP-66, 8KW 3P of Healer Enterprises or equivalent as approved by GE.
Supply and fixing in replacment of nature switch complete with timer , contactor, relays and suitable rating MCBs for incoming and out going in built in suitable IP 66 enclosure (Hensel) of single phase integrated models of capacity 8 KW complete all as specified and directed. Make : Cat Part No. SWADEEP-66, 8KW 1P of Healer Enterprises or equivalent as approved by GE.
Supply and fixing thermoplastic polystyrene/ polycarbonate enclosure bus bar chamber , shock proof , vermin proof and dust proof complete with 04 Nos aluminium strip of capacity 100 Amps including non metalic clapms and GI nut bolts and washers of suitable size and fixed on pole / wall complete all as specified and directed. Make:- Hensal/ Rittal/ ABB.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm tthick buried directly in ground (earth plate not less than 3.25 mtr deep below the normal ground level ) with top edge of plate not less than 2.5 mtr below the normal ground level connected to galvanized earth strip 32 mm X 6 mm thick by means of nuts bolts, washers, check nuts of iron or steel and welding full length of strip with earth plate including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) medium grade GI watering pipe 20 mm bore with funnel and wire mesh and 40 mm bore GI pipe light grade proection pipe up to test point etc including excavation and charcoal ,common salt surrounded with 15 cm all around the plate complete all as specified and directed.
M&L for galvanised iron round bracket made out of 40 mm bore GI tubing including making provision for fixing on 9/ 11 mtr steel tubular pole and fixing and connecting up of LED lights (LED light shall be measured seperately under respective item of BOQ) complete all as specified and directed.
M&L for making service connection from MCB DB to LED flood light fitting with PVC sheathed 2.5 sqmm twin core multi-stranded aluminium conductor cable of required length complete all as specified and directed.
M&L for drilling suitable dia horizontal bore holes for insertion / laying of up to 50 mm bore GI tubing of any description below/ under road surface/ floors etc with using mechanical or manual devices as required at site including making good disturbed surface to match with the existing streta after laying pipes complete all as specified and directed.
S&F MCB single pole 240 volts, 'B' curv of rating from 6 to 40 Amps, with rupturing capacity 10 KA,including providing thimble for out going cables complete all as specified and directed. Make:- Legrand / Schenieder/ Seimens
S&F MCB SPN 240 volts, 'B' curv of rating from 6 to 40 Amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. Make:- Legrand / Schenieder/ Seimens
M&L for painting of LT panels/ feeder pillar boxes outdoor/ indoor type of any sizes or rating installed at varoius location at 4 Area under GE (AF) Adm Area Agra with two coats of synthetic enamel paint of approved colour with spray machine after cleaning the surface and preparing the same for painting complete all as specied and directed.
M&L for welding work to LT panels/ feeder pillar box as per requirement at site to match with existing complete all as specified and directed.
M&L for MS sheet thickness 3.15 mm for repairing existing damaged panel doors due to corrison of different type and sizes complete with hinges, hot, cold welding work, fabricating, locking arrangement etc including painting with one coat of red oxide and two coats of synthetic enamel paint complete all as specified and directed.
M/s Sumer Associates
M/s S.M. Construction
Balaji Associate
GUPTA ENGINEERING WORKS
TRIVENI ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .