Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹45.7 L+₹3.8 L (8.95%)Rejected-Finance 00 HAIDARPUR JAMALPUR ROAD SADAR JAUNPUR UTTAR PRADESH 222001 | JAUNPUR | UTTAR PRADESH | 222001 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹47.2 L+₹5.3 L (12.6%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | M/S. R.K. ENTERPRISES L2 | M/S TRIVENI BUILDERS L1 | N.S.ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.00 | Surface dressing n exc 15 cm deep including site clearance of any type of soil complete all as specified and as directed. | 65 | Sqm | 105 ₹6,825 | 95 ₹6,175 Lowest | 155 ₹10,075 |
| 2.00 | Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, taking up/ laying of underground cable and getting out in any type of soil complete all as specified and as directed. | 385.66 | Cum | 918 ₹3,54,035.88 | 220 ₹84,845.2 Lowest | 250 ₹96,415 |
| 3.00 | Returning, filling in trenches of any type of soil including spreading, leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed. | 217.92 | Cum | 300 ₹65,376 | 95 ₹20,702.4 Lowest | 100 ₹21,792 |
| 4.00 | Removing of excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed. | 174.14 | Cum | 260 ₹45,276.4 | 90 ₹15,672.6 Lowest | 250 ₹43,535 |
| 5.00 | M&L for PCC (1:4:8), type D-2 using 40mm graded stone aggregates as in foundation, filling and mass concrete complete all as specified and directed. | 2.27 | Cum | 5,200 ₹11,804 | 4,800 ₹10,896 | 3,500 ₹7,945 Lowest |
| 6.00 | M&L for brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar (1:6) complete all as specified and directed. | 4.04 | Cum | 7,000 ₹28,280 | 6,500 ₹26,260 Lowest | 6,500 ₹26,260 Lowest |
| 7.00 | M&L for rendering 15 mm thick on concrete/brick surface on wall in cement mortar (1:6) other than fair face of brick work, finished even and smooth without using extra cement complete all as specified and directed. | 11.7 | Sqm | 260 ₹3,042 | 210 ₹2,457 Lowest | 250 ₹2,925 |
| 8.00 | M & L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. | 4.5 | Cum | 1,600 ₹7,200 | 950 ₹4,275 Lowest | 3,800 ₹17,100 |
| 9.00 | M&L for hard core of broken stone or boulders of gauge not exc 63mm deposited spread and leveled in layers not exceeding 15cm thick watered and rammed to a true surface complete all as specified and directed. | 4.2 | Cum | 1,700 ₹7,140 Lowest | 1,800 ₹7,560 | 4,500 ₹18,900 |
| 10.00 | M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. | 2.7 | Cum | 1,750 ₹4,725 | 700 ₹1,890 Lowest | 4,000 ₹10,800 |
Tender Value
Refer Docs
EMD Value
₹85,400
Closing Date
14 Jan 2026, 6:00 pmClosed
GE AF PANAGARH
GE AF PANAGARH MES AF STATION PANAGARH PO BIRUDIAH WEST BENGAL 713148
PROVISION OF STANDBY POWER SUPPLY TO CERTAIN BUILDINGS AND ALLIED SERVICES AT AIR FORCE STATION ARJAN SINGH UNDER GE(AF) PANAGARH
2025_MES_745371_1
C/8868/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STATION PANAGARH
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE AF PANAGARH
₹85,400
8 May 2026
22 Dec 2025
16 Jan 2026
22 Dec 2025
14 Jan 2026
6 Jan 2026
Surface dressing n exc 15 cm deep including site clearance of any type of soil complete all as specified and as directed.
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, taking up/ laying of underground cable and getting out in any type of soil complete all as specified and as directed.
Returning, filling in trenches of any type of soil including spreading, leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed.
M&L for PCC (1:4:8), type D-2 using 40mm graded stone aggregates as in foundation, filling and mass concrete complete all as specified and directed.
M&L for brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for rendering 15 mm thick on concrete/brick surface on wall in cement mortar (1:6) other than fair face of brick work, finished even and smooth without using extra cement complete all as specified and directed.
M & L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for hard core of broken stone or boulders of gauge not exc 63mm deposited spread and leveled in layers not exceeding 15cm thick watered and rammed to a true surface complete all as specified and directed.
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
S & F for polythene film, 150 micron thick, laid in floor complete all as specified and directed.
M&L for 100mm thick PCC (1:3:6), type C-2 (using 40mm graded stone aggregates) as in sub base of floors including necessary form work even and rough to receive the topping layer in DG shed complete all as specified and directed.
M&L for 75 mm thick PCC (1:2:4), type B-1 (using 20mm graded stone aggregates) as in path, hardstanding including necessary form work and even and smoth without using extra cement in DG shed complete all as specified and directed.
S & F for 3mm thick glass dividing strips and 38mm wide inserted in position and confirm to design complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu m, getting out in soft/ lose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, including watering and removing surplus soil to a distance not exc. 50m and making good the surface omplete all as specified and directed.
S &F for structural steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed.
M&L for plates Fe-410-W (Gde-E-250) quality-B (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zic chrome primer complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coated GI based plain steel sheet 0.50mm thick of approved colour having tensile strength 550 Mpa as in ridges, hips, valley gutters, fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
M & L for Hand rails, wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for ecuring wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work onforming to Fe-290 Gde E-165 complete all as specified and directed
M&L for applying two coats of cement based paint over a coat of cement primer on new wall surfaces complete all as specified and directed.
M&L for 75mm thick PCC type C-2 (1:3:6), (using 40 mm graded stone aggregates) as in sub base of path including necessary form work even and rough to receive the topping layer complete all as specified and directed.
M&L for chequered cement concrete tiles of size 30 cm x 30cmx22 mm thick set, jointed in neat cement slurry in floor and pointed in white or grey cement and no pigment of machine pressed to match the shade of tiles laid over and including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and as directed.
Design, fabrication,supply, insallation, testing and commissioning LT panel board (outdoor type floor mounted)of size1000mm x 800mm x 400mm suitable for working on 3 phase, 4 wire, 415 volts, AC, 50 Hz outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3.2mm thick CRCA sheet duly powder coated (seven tank process) and as approved by GE. The panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, botton cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequte size of MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, MCCBs shall have extended bus bar links and panel mounted on 50x50x5mm size MS angle iron frame duly painted in and including PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in foundation design subject to approval of GE as per as site requirement. Minimum claerance from ground level is 450 mm complete all as specified and comprising :- (a) MCCB, 160 Amps, FP, 25 KA, 415 volts, 50 Hz - 01 No (in coming) (b) MCCB, 125 Amps, FP, 16 KA, 415 volts, 50 Hz - 01 No (outgoing) (c) MCCB, 63 Amps, FP, 16 KA, 415 volts, 50 Hz - 02 Nos (outgoing) (d) Digital multi-fuctional meters for measuring current, voltage and frequency including CTs of suitable rating and class- 01 No (as out going) (e) Digital voltmeter (0-500V) with CTs and VSS-01 set, Digital Ammeter (0-100A), with CTs & ASS-01 set (f) LED phase indication lamps RYB-01 set (g) Aluminium bus bar TPN 400 Amps rating - 01 set (Note: LT panel drawing to be approved by GE duly recommended by Engr-in-Charge). ( Make: C&S/ L&T/Legrand/Siemens/Schneider)
Design, fabrication,supply, insallation, testing and commissioning LT panel board (outdoor type floor mounted)of size1000mm x 800mm x 400mm suitable for working on 3 phase, 4 wire, 415 volts, AC, 50 Hz outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3.2mm thick CRCA sheet duly powder coated (seven tank process) and as approved by GE. The panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, botton cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequte size of MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, MCCBs shall have extended bus bar links and panel mounted on 50x50x5mm size MS angle iron frame duly painted in and including PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in foundation design subject to approval of GE as per as site requirement. Minimum claerance from ground level is 450 mm complete all as specified and comprising :- (a) MCCB, 100 Amps, FP, 25 KA, 415 volts, 50 Hz - 01 No (in coming) (b) MCCB, 63 Amps, FP, 16 KA, 415 volts, 50 Hz - 01 No (outgoing) (c) MCCB, 16 Amps, FP, 16 KA, 415 volts, 50 Hz - 03 Nos (outgoing) (d) Change over switch, 125Amps, FP-01 Nos (e) Digital multi-fuctional meters for measuring current, voltage and frequency including CTs of suitable rating and class- 01 No (as out going) (f) Digital voltmeter (0-500V) with CTs and VSS-01 set, Digital Ammeter (0-100A), with CTs & ASS-01 set (g) LED phase indication lamps RYB-01 set (h) Aluminium bus bar TPN 400 Amps rating - 01 set (Note: LT panel drawing to be approved by GE duly recommended by Engr-in-Charge). ( Make: C&S/ L&T/Legrand/Siemens/Schneider)
Design, fabrication,supply, insallation, testing and commissioning LT panel board (outdoor type floor mounted)of size1200mm x 900mm x 400mm suitable for working on 3 phase, 4 wire, 415 volts, AC, 50 Hz outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3.2mm thick CRCA sheet duly powder coated (seven tank process) and as approved by GE. The panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, botton cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequte size of MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, MCCBs shall have extended bus bar links and panel mounted on 50x50x5mm size MS angle iron frame duly painted in and including PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in foundation design subject to approval of GE as per as site requirement. Minimum claerance from ground level is 450 mm complete all as specified and comprising :- (a) MCCB, 100 Amps, FP, 25 KA, 415 volts, 50 Hz - 01 No (in coming) (b) MCCB, 63 Amps, FP, 16 KA, 415 volts, 50 Hz - 01 No (outgoing) (c) MCCB, 16 Amps, FP, 16 KA, 415 volts, 50 Hz - 03 Nos (outgoing) (d) Digital multi-fuctional meters for measuring current, voltage and frequency including CTs of suitable rating and class- 01 No (as out going) (e) Digital voltmeter (0-500V) with CTs and VSS-01 set, Digital Ammeter (0-100A), with CTs & ASS-01 set (f) LED phase indication lamps RYB-01 set (g) Aluminium bus bar TPN 400 Amps rating - 01 set (Note: LT panel drawing to be approved by GE duly recommended by Engr-in-Charge). ( Make: C&S/ L&T/Legrand/Siemens/Schneider)
M & L for PCC 1:2:4 type C2 using 20mm graded for padestal coping incl necessary formwork finished fair using extra cement omplete all as specified and directed by Engineer-in-Charge
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 32/6mm thick galvanised iron strip as earthing lead by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 50mm bore GI pipe (light grade) for protection of earth strip and PCC (1:3:6) type C-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles made out of 8mm dia round mild steel bar, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion after dismantling of old unserviceable earthing with all material etc all as specified and directed. (Note:- (i) Earth strip and protection pipe upto board 7.5 m and others mentioned in above are included in this item (ii) The earthing pit shall be provide with proper earth pit and pit cover (iii) pit cover shall be painted with two coats of cement base paint of approved colour and pit number to be marked on a GI plate above 45 cm from GL as per colour code followed by AF authority (iv) Purchase voucher of GI plate and strip having GST number shall be provided before the payment claim (v) Earthing test certificate from users shall be provided before the payment claim)
M&L for earthing complete with copper earth plate electrode 600x600x3.15 mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 20x3mm thick copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 50mm bore GI pipe (light grade) for protection of earth strip and PCC (1:3:6) type C-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles made out of 8mm dia round mild steel bar, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion after dismantling of old unserviceable earthing with all material etc all as specified and directed. (Note:- (i) Earth strip and protection pipe upto board 7.5 m and others mentoned above are included in this item (ii) The earthing pit shall be provide with proper earth pit and pit cover (iii) pit cover shall be painted with two coats of cement base paint of approved colour and pit number to be marked on a GI plate above 45 cm from GL as per colour code followed by AF authority (iv) Purchase voucher of GI plate and strip having GST number shall be provided before the payment claim (v) Earthing test certificate from users shall be provided before the payment claim)
Material and labour for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.3 mm thick buried directly in ground( earth pit not less than 2.25 mtrs deep below normal ground level )with the top edges of plate not less than 1.5 mtrs below normal ground level connected to GI wire 4mm by means of GI nuts, bolts check nuts and washers earth lead protected by 15mm dia GI pipe light grade and connected to main distribution board/earthing test point all as shown in electrical plate No 3 of SSR part 1 and all as specified including taking down old unserviceable earthing and testing of earthing on completion. Notes:-The unit rate also including for excavation, earth work in any type of strata, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix , type B1 cover reinforced with 8mm dia TMT bars @150mm C/C both ways ,GI funnel with GI watering pipe 20mm dia medium grade, wire mesh, protection pipe 15mm dia GI pipe light grade for earth lead upto 7.50m long complete all specified and directed. (Note:- (i) Earth wire and protection pipe upto board 7.5 m and others mentoned above are included in this item (ii) The earthing pit shall be provide with proper earth pit and pit cover (iii) pit cover shall be painted with two coats of cement base paint of approved colour and pit number to be marked on a GI plate above 45 cm from GL as per colour code followed by AF authority (iv) Purchase voucher of GI plate and strip having GST number shall be provided before the payment claim (v) Earthing test certificate from users shall be provided before the payment claim)
Design, fabrication,supply, insallation, testing and commissioning LT Junction box (outdoor type floor mounted)of size 800mm x 600mm x 400mm suitable for working on 3 phase, 4 wire, 415 volts, AC, 50 Hz outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3.2mm thick CRCA sheet duly powder coated (seven tank process) and as approved by GE. The panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, botton cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequte size of MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, MCCBs shall have extended bus bar links and panel mounted on 50x50x5mm size MS angle iron frame duly painted in and including PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in foundation design subject to approval of GE as per as site requirement. Minimum claerance from ground level is 450 mm complete all as specified and comprising :- (a) MCCB, 320 Amps, FP, 36 KA, 415 volts, 50 Hz - 01 No (in coming) (b) Digital multi-fuctional meters for measuring current, voltage and frequency including CTs of suitable rating and class- 01 No (as out going) (c) Digital voltmeter (0-500V) with CTs and VSS-01 set, Digital Ammeter (0-100A), with CTs & ASS-01 set (d) LED phase indication lamps RYB-01 set (e) Aluminium bus bar TPN 600 Amps rating - 01 set (Note: LT Junction box drawing to be approved by GE duly recommended by Engr-in-Charge). ( Make: C&S/ L&T/Legrand/Siemens/Schneider)
Supply,laying, jointing and testing, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 300 sqmm 3.5 core laid in trenches/ on wall, ducts, pipes, on poles and connection with necessary cables lugs, glands, suitable for mild steel saddle clips (were cable laid in ceilings/wall without cable duct) nut bolts complete. all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointing and testing, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 150 sqmm 3.5 core laid in trenches/ on wall, ducts, pipes, on poles and connection with necessary cables lugs, glands, suitable for mild steel saddle clips (were cable laid in ceilings/wall without cable duct) nut bolts complete. all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointing and testing, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 95 sqmm 3.5 core laid in trenches/ on wall, ducts, pipes, on poles and connection with necessary cables lugs, glands, suitable for mild steel saddle clips (were cable laid in ceilings/wall without cable duct) nut bolts complete. all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointing and testing, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 70 sqmm 3.5 core laid in trenches/ on wall, ducts, pipes, on poles and connection with necessary cables lugs, glands, suitable for mild steel saddle clips (were cable laid in ceilings/wall without cable duct) nut bolts complete. all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointing and testing, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 sqmm 4.00 core laid in trenches/ on wall, ducts, pipes, on poles and connection with necessary cables lugs, glands, suitable for mild steel saddle clips (were cable laid in ceilings/wall without cable duct) nut bolts complete. all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed. (Note: Punned thickness of sand shall be measured and paid).
M&L for 50mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for cable protection complete all as specified and directed.
M&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified and as directed.
M&L for boring of holes under road, pavement, hard standing by trenchless technology/manual excavation as necessary including machine, tools etc as per site requirement complete all as specified and directed.
M&L for 80mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for cable protection complete all as specified and directed.
Taking down and carring the exisiting DG Set of capacity 63KVA from 31 Wg HQ and shifting it to SRE building and refixing the same at new said location within the Air force area complete all as specified and as directed by GE. (Note : (a) The cost of necessary taking down & carring of DG set through transportation of any mechanical method within the Air force area from one place to another place shall deemed to be included in the quoted rate. (b) Any damage of DG set during taking down, carring through transportation and fixing in new location shall be borne to tha contractor . Cost of damage recovered from the payment. (c) All the labour cost required in this work shall be included in this job .)
Taking down and carring the exisiting DG Set of capacity 63KVA from TMQ power house and shifting it to pump house No 02 and refixing the same at new said location within the Air force area complete all as specified and as directed by GE. (Note : (a) The cost of necessary taking down & carring of DG set through transportation of any mechanical method within the Air force area from one place to another place shall deemed to be included in the quoted rate. (b) Any damage of DG set during taking down, carring through transportation and fixing in new location shall be borne to tha contractor . Cost of damage recovered from the payment. (c) All the labour cost required in this work shall be included in this job .)
Taking down and carring the exisiting DG Set of capacity 63KVA from power house No 03 and shifting it to pump house No 04 and refixing the same at new said location within the Air force area complete all as specified and as directed by GE. (Note : (a) The cost of necessary taking down & carring of DG set through transportation of any mechanical method within the Air force area from one place to another place shall deemed to be included in the quoted rate. (b) Any damage of DG set during taking down, carring through transportation and fixing in new location shall be borne to tha contractor . Cost of damage recovered from the payment. (c) All the labour cost required in this work shall be included in this job .)
Taking down and carring the exisiting DG Set of capacity 750KVA from 87SQM and shifting it to HQ building CSS and refixing the same at new said location within the Air force areacomplete all as specified and as directed by GE. (Note : (a) The cost of necessary taking down & carring of DG set through transportation of any mechanical method within the Air force area from one place to another place shall deemed to be included in the quoted rate. (b) Any damage of DG set during taking down, carring through transportation and fixing in new location shall be borne to tha contractor . Cost of damage recovered from the payment. (c) All the labour cost required in this work shall be included in this job .)
S&F for BMS system of 750KVA DG set including control panel, control wiring, sensors, with all fixing accessories complete all as specified and as directed. Make Cummins (product No KIT3238752)
S & F for ATS panel of 62.5/63 KVA DG set incl control wiring, nuts and bolts, PCC foundation (1:2:4) of 20mm graded aggregate etccomplete all as specified and as directed. ( Make: C&S/ L&T/Legrand/Siemens/Schneider)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
Tender8868.pdf
Tender Documents • 0.92 MB
BOQ_834625.xls
BOQ • 1.20 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .