Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
22 Jul 2025, 12:00 pmClosed
EXECUTIVE ENGINEER M AND H DIVISIO DODA
KHELLANI DODA
Design Supply Erection and Commissioning of Controlled Conditioned Cropping Room of S for Cultivation of Mushroom along with packing room and other allied works on Turn Key Basis at Saffron Farm Berwar Kisht
2025_PWDJK_280776_1
MHDD/TS/2025-26/31
Open Tender
Civil Works - Others
Turn-key
75 days
BERWAR KISHTWAR
AS PER SBD
2 documents required · 2 mandatory
₹1,000
EXECUTIVE ENGINEER M AND H DIVISIO DODA
₹60,000
4 Aug 2025
8 Jul 2025
22 Jul 2025
8 Jul 2025
22 Jul 2025
8 Jul 2025
Amount
Clearing of site by employing labour, tool and tackle and leveling of ground by employing men and machinery for start of work. The job includes labour cost,hire charges of tools and tackles, machinery and taxes as applicable
Site Preparation Earthwork in excavation by manual means over area for leveling purpose including disposal of excavated earth up to 50m from cutting edge and should be disposed in near-by all kind of soil Foundation for plinth work = (134’-0” x 1’-6” x 0’-6’’) = 100.5 ft3 Floor area = (40’-0” x 18’-0” x 0’-6”) + (15-0” x 12’-0”x 0’-6”) = 450 ft3 Foundation for columns = 10 x (2’-6” x 2’-6” x 2’-6”) = 156.25 ft3 Total = 706.75ft3 = 20.01 m3 Area to be excavated keeping in view the earth quake resistance for which a ms mesh(10 mm) is to be provided in the base foundation of the plinth
Providing and laying of cement concrete (1:5:10) using 40mm nominal size nallah stone. Plinth work =134’-0”x1’-6”x0’-6’’= 100.5ft3 Floor area=40’-0”x18’-0”x6”+15’-0”x12’-0”x6”= 450ft3 Foundation for columns = 10(2’-6”x2’-6”x0’-6”) = 31.25ft3 Total = 581.75ft3 = 16.47m3
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level wit1:2:4 (one cement: Two coarse sand: Four Graded stone aggregate 20 mm nominal in size) Plinth work=134’-0”x1’-6”x1’-0’’= 201ft3 Foundation for Columns=10 x (1’-6”x1’-6”x2’-0”) =45ft3 Total = 246ft3 = 6.96m3
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Mild steel and medium tensile steel bars for flooring 10mm bar of length 1800’ = 548.64 mtr = @ 0.617 kg per metre = 338.51 kg 10 mm bar of length Tie beam 636’ = 193.85 mtr = @0.617 kg per metre = 119.60 kg 10 mm bar of length Column 160’[email protected] per metre = 30.08 kg 8mm bar of length Column 160’[email protected] per metre=19.26kg Total=507.45kg
Centering and shuttering including strutting, propping etc. and removal of form work for: 4.6.1 Foundations, footings, bases for columns Area=2x158’x1’+10x4x1’-6x2’+1’6”x6”=436.75ft2=40.57m2
12 mm cement plaster to plinth wall of mix 1 : 3 (1 cement : 3 fine sand) Area=2x158’x1’=316ft2=29.35m2 G. Total = 29.35 m2
Cement concrete flooring and foundation as per the site requirement 1:2:4(1 cement:2 sand:4 graded stone finished with a floating coat of neat cement including cement slurry but excluding the cost of noising of steps complete0 50mm thick 20mm size stone aggregate.) Floor area=40’x18’+15’x13’=915ft2= 85.00 m2
Steel work welded in built up section/ framed work including cutting, hosting, applying a priming coat using structural steel. In gratings, frames, guard bard, ladders, railings etc. 6 No. of trusses including primer and enamel paint including nut bolts, kingpost, struts etc. a. Column Square Hollow Pipe Section(100 x 100 x 3.6mm): 12 Columns of Height 16 feet = 192 ft 04 Columns of Height 12 feet = 48 ft Total Length = 240 feet i.e. 73.15 mtr @ 10.72Kg/mtr = 784.18 Kg b. MS Sq. Foundation Plate of size (150 x 150 x 10 mm) @ 1.77 Kg per plate for 16 plates = 28.32 Kg c. MS Sq. Connecting Plate of size (100 x 100 x 06 mm) @ 0.47 Kg per plate for 16 plates = 07.52 Kg d. MS Pipe for Truss of size 80 x 40 x 3.6 = 62 x 5 = 310 ft e. MS Pipe for Truss of size 80 x 40 x 3.6 = 44 x 2 = 88 ft Total Truss Pipe Length = 398 ft i.e. 121.31 @ 6.2Kg / mtr = 752.12 Kg f. MS Pipe for Purlins of size 50 x 50 x 3.6 = 52 x 10 = 520 ft i.e. 158.50 mtr @ 5.07 Kg/mtr = 803.60 Kg g. Bracing Top of size 40 x 40 x 3.2 = 198 ft i.e. 60.35 mtr @ 5.79 Kg/mtr = 349.42 Kg h. Bracing Side of size 40 x 40 x 3.2 = 264 ft i.e. 80.46 mtr @ 5.79 Kg/mtr = 465.91 Kg e. Side Rails (60 x 40 x 3.2 mm) 165’ = [email protected]/mtr = 187.59 kg Total Weight = 3378.66 kg
PCC Ramp, Pavement and other allied civil works Construction of drains, Providing and laying of 100 mm drain outlet for water in cropping room during cleaning, providing and fixing of printed vinyl sheet of size 4 ftx6ft x 3mm thick on outer wall of main shed as per the requirement of intending deptt. and shall be intimated separately.
MS Racks for Cultivation of Mushrooms:- Design, Supply, Fabrication and Installation at site of MS Racks for placing of Compost bags for cultivation of Mushrooms in the cropping and packing area. The racks shall be fabricated along the periphery of inner two walls of the shed as well as in the center area of the cultivated room. The height of each rack should be of 05 feet. In the packing room the racks shall be made along the periphery of three walls and is of height of 6 feet each. The Main structural frame shall be made out of MS Angle 40 x 40 x 6 mm and Racks shall be made out of MS Flats of size 40 x 5 mm along with MS Angle 40 x 40 x 6 mm for support brackets and MS Angle 40 x 40 x 6 mm and MS Flat 40 x 5 mm for racks of packing area. The Job also includes supply and Fabrication of moving type ladder made out of M.S. angle iron of size 40 x 40 x 6 mm having platform for standing on top and having castor wheels for movement. Complete job includes cost of material, skilled labour required, welding charges along with all the tools and tackles required for the execution of the job. The job also includes painting of complete structure with red oxide first and then two coats of black enamel paint of standard make
CLOSED STRUCTURE/PUF PANEL ROOM:- Supply and installation at site of Prefabricated PUF (Poly-Urethane Foam) Panels of size 60 mm thick Fire proof Panels for walls (PPGI finish on both sides and 70/100 mm thick PUF on the Roof Top of the Complete Structure) to make a closed structure on the outer framefor the Rooms of Size (40x18x16) and (15x12x12) feet. Prefabricated Sandwich PUF panels with Cam toggle type fasteners fitted and self-locking PVC gaskets fitted on all sides of wall and ceiling/roof including rivets, Silicones, Anchor fastener, self-drilling screw and all other allied accessories required for the installation/erection of PUF panels. a. Wall to wall cam locking system. Internal/External flashing to be provided. b. 60 mm flush type doors having size 3’x6’ for cultivation room and packing room with view port of double glass. c. 70/100 mm PUF on the Roof of the Complete Structure. d. Heavy duty cast alloy handles with heavy duty hinges with chrome finish. Air right heavy duty sealing gasket below door with double sweep, position seal closure cushions closing of door. e. Safety release knob to be provided from inside the door. f. Temperature required in the room is 13˚C to 25˚C.
MACHINES DESCRIPTION AND ALLIED ACCESSORIES Refrigeration Unit:- SITC of refrigerant unit of capacity 5.5 TR -02nos (One working + One standby) (420V/3Ph/50Hz) for maintaining a temperature of 13 ˚C to 25˚C (or as per requirement of end user) around the year. The unit shall comprise of two machines one working and one standby with following features. a. 02nos Indoor unit (1W + 1S) which designed in such a way that works separately with each outdoor unit and it should consists of minimum two number fan blowers and body to be made of GI powder coated. b. 02 nos Outdoor units (1W + 1S) to be sealed heavy duty air cooled with low noise level and minimal vibration. MOC should be GI powder coated. Filter dryer can be Internal/External. c. R407a/R22 refrigerant or any other equivalent as per OEM design. d. Control panel should have microprocessor based digital temperature controller/indicator for easy readability with following features. i.It should protect device from single phasing, voltage unbalance, phase reversal and under/over voltage. ii. It should also show real time voltage between phase and neutral including auto cascading so that only one unit shall remain operational at one time. iii. It should shut down the system in case of fault from pressure control/similar device. iv. It should have safety controls such as delay at start up and minimal disable time to protect compressor from close start. The job includes complete installation of refrigeration system with suitable MS Stands for Outdoor units, 30kVA Servo Voltage Stabilizer for operation of machines and fitment of 3 phase monitoring relay, along with copper pipes, tees/elbows/reducers brazing charges and tools and tackles required for the execution of the job.
Fresh air Damper /Blower/ Ducts/Plenum:- Supply and installation of air mixing chamber inside the cultivation room, Aluminum Damper for CO2 exhaust, fresh air damper system and return air as per site requirement. The Job includes SITC of blowers of requisite specifications as per OEM design along with all allied accessories. The job also includes providing/ fitting of Elbow Duct with Air filters for fresh air inlet and CO2 exhaust outside the plant along with installation of air plenum duct/air tight cloth duct with evaporator and poly duct inside the room for air distribution. It also includes fresh air dampers in the packing room along with pre filters for protection against insects and dust as and where required.
Split AC for Packing Area:- SITC Of 1 no. 1.5 ton split AC along with voltage stabilizer of capacity 05KVA of reputed make in the packing area. The job also includes P/F of Split AC along with all other allied accessories like cooper cable, MCB, Outdoor stand etc. required for the execution of the job.
Monoblock pump for fresh water supply: Providing and fitting of 0.5 Hp Monoblock Self Priming Pump of reputed make for supply of water inside the room as and when required. It also Includes providing, fitting and laying of pipes of requisite sizes along with minimum three nos taps along with one roll of rubber pipe with all kind of fittings required for the execution of job.
Electrical fittings: The job includes electric fittings along with embedding of PVC conduits in the walls with multi stranded electric cables with switch boxes and switch boards/Sockets/Switches/MCB’s of requisite amperage suitable for Refrigeration system/AC’s, Stabilizer, Blowers, Mono block pump, Vapor proof LED Lights, LED flood lights of suitable watts including chemical earthling of all electrical items. Complete job includes cost of material and labor charges for the execution of job.
CAMC Charges for one year after the completion of one year warranty period.
MOHD ASHRAF DEV (BID ID -2407254)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .