Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹1.6 Cr B 5 25 YAMUNA VIHAR NEW DELHI NORTH EAST DELHI DELHI 110053 | ₹1.6 Cr |
Tender Value
₹2.2 Cr
EMD Value
₹2.2 L
Closing Date
25 Jun 2026, 11:00 amClosed
Providing, fabricating and fixing barricading, including gate work with structural steel framework covered with precoated GI profile sheet at MEAs Plot in INA, MEA residential complex, New Delhi 110023
NBCC/SBGDELHIIII/NIT/MEAINA/2026/25
NBCC/SBGDELHIIII/NIT/MEAINA/2026/25
Open Tender-Domestic
Civil Works General
New Delhi, Delhi
₹11,800
₹2.2 L
21 Jul 2026
17 Jun 2026
25 Jun 2026
25 Jun 2026
Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level
6 4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) CUM 40.00 6812 6,826.92 2,73,076.80
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of
centering, shuttering, finishing and reinforcement - All work up to plinth level
8 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) CUM 4.00 9045.75 9,065.56 36,262.24
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced
cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland
Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS:
9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing
strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost
of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the
following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in
design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of
the specified minimum cement content, the contractor shall have discretion to either re-design the mix or
bear the cost of extra cement.
5.33.1 All works upto plinth level -
5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum CUM 217.50 9504.75 9,525.57 20,71,811.48
10 5.33.2 All works above plinth level upto floor V level -
Concrete of M25 grade with minimum cement
content of 330 kg /cum
11 5.35 Add for using extra cement in the items of design mix over and above the specified cement content therein QUINTAL 70.65 733.50 735.11 51,935.52
Centering and shuttering including strutting,
propping etc. and removal of form for all heights :
12 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete SQM 450.00 392.15 393.01 1,76,854.50
Walls (any thickness) including attached pilasters, butteresses,
plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access
platform Digitally signed by MAYANK
S.No. ITEM_NO ITEM_DESCRIPTION UNIT QTY CF - AMOUNT
15 5.9.5 For Lintels, beams, plinth beams, girders, bressumers and cantilevers SQM 444.00 736.40 738.01 3,27,676.44
16 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts SQM 900.00 961.30 963.41 8,67,069.00
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding
all complete upto plinth level.
5.22.6 Thermo-Mechanically Treated bars of grade Fe 500D or more. KG 21195.00 107.85 108.09 22,90,967.55
Brick work with common burnt clay F.P.S. (non modular) bricks of Class designation 7.5 in superstructure
above plinth level up to floor V level in all shapes and sizes in :
6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) CUM 12.00 9105.95 9,125.89 1,09,510.68
Providing and Applying 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1
cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
Providing and Finishing walls with water proofing cement paint of required shade on New work (Two or more
coats applied @ 3.84 kg/10 sqm) etc. complete and as per sa sfac on of Engineer-In Charge
Steel Works for Trusses of Barricading, Gates, Frames, Hinges, Supports, all works complete -
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting,
21 10.16 hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted -
with special shaped washers etc. complete..
10.16.3 Electric resistance or induction butt welded tubes KG 47997.723 194.40 194.83 93,51,396.37
22 13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade -
13.61.1 Two or more coats on new work SQM 1500.00 155.90 156.24 2,34,360.00
23 10.19 Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. KG 1110.00 97.20 97.41 1,08,125.10
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as
approved by Engineer-incharge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per
sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester
top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches
during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-
charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal,
complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and
trusses and including cutting to size and shape wherever required.
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of
specified diameter and length below the pile cap, to carry a safe working load not less than specified,
excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and
temporary casing of appropriate length for setting out and removal of same and the length of the pile to be
embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel
technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with
all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck
Mounted rotary/TMR/Tubewell boring machine shall not be used
Digitally signed by MAYANK
S.No. ITEM_NO ITEM_DESCRIPTION UNIT QTY CF - AMOUNT
Providing, Fabricating, Installing &Commissioning of Back Lit Signage Boards including fascia, signage cabinet,
electrical fitting, fixture & required structural steel work including cutting, hoisting, fixing in position and
applying a priming quote of approved steel primer all complete, with back support of GI sheet and 3 MM
sunboard neatly pasting on GI sheet, complete filling of module in box, complete with rain proof power
26 NDSR-1 supply to support various internal components of signage board etc. over the structural steel framework ; all SQM 18.00 12232.00 2,20,176.00
complete as per detailed specifications, design & instructions of Engineerin- charge. (The area of Board
excluding outer borders only will be measured for payment) The works also include costs of cladding with
25mm SHS steel members. The size of the hoardings shall be decided by the Engineer in Charge as per Site
conditions and requirements including led light and all accessories
Providing, Fabricating, Installing & Commissioning of Front Lit Signage Boards including fascia, signage
cabinet, electrical fitting, fixture & required structural steel work reveted bolted or welded in builtup
sections, and framed work, including cutting, hoisting, fixing in position and applying a priming quote of
approved steel primer all complete, with installation 3 MM ACP, neatly pasted Eco Solvent with matt or gloss
27 NDSR-2 lamination, frame to support various internal components of signage board etc. over barricading work all
complete as per detailed specifications, design & instructions of Engineer-in-charge. Structural steel work of
barricading upto its connection & support of complete signage board is exclusive of this item which shall be
provided by NBCC. The works also include costs of cladding with 25mm SHS steel members. The size of the
hoardings shall be decided by the Engineer in Charge as per Site conditions and requirements.
A With vinyl fascia SQM 18.00 1432.00 25,776.00
Electrical DSR 2025
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in
28 1.12 surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor METRE 350.00 373.00 1,30,550.00
single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper
conductor, single core cable in surface/ recessed steel conduit as required.
1.7.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire METRE 55.00 652.00 35,860.00
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on
30 2.3 surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections,
powder painted including earthing etc. as required. (But without MCB/ RCCB/Isolator)
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current
31 2.14 circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete
with connections, testing and commissioning etc. as required.
2.14.3 63Amps (100 milliamperes) EACH 8.00 2866.00 22,928.00
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for
33 2.1 inductive load of following poles in the existing MCB DB complete with connections, testing and
commissioning etc. as required
Digitally signed by MAYANK
S.No. ITEM_NO ITEM_DESCRIPTION UNIT QTY CF - AMOUNT
Installa on, tes ng and commissioning of pre wired, fluorescent fi ng / compact fluorescent fi ng of all
34 1.41 types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. EACH 8.00 259.00 2,072.00
mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry
35 5.2 enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as EACH 8.00 7658.00 61,264.00
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/
recessed conduit/ submain wiring/ cable as required.
LED Smart Street light fixture, powder coated pressure die cast aluminium (System. System lumen efficacy
≥105 and <120 lm/Watt) Supplying, installation, Testing & Commissioning of Smart Street light LED fixture,
powder coated pressure die cast aluminium body with built in or separate driver as per the requirement ( <
700ma), Input voltage: 140-270 Volt AC, frequency 50/60 Hz, Operating temp range -5 0C to 50 0C, internal
surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 ,
P. F.≥0.95, IP-66,IK-08, CRI ≥70 , under voltage and over voltage protection, EMI- EMC as per CISPR-15, lenses
for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to
fit in up to 65mm dia pipe, life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained
till life ends as per LM80 extrapolation IES TM-21-11
report , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , Maximum power consumption should not
more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c
external connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing
etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output .
8.18 LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures asper BIS shall be submitted.
Shape size and CCT shall be as approved
by Engineer-in-Charge as per requirement. (Thermal management:
heat sink of aluminium housing such that LED junction temperature
shall not rise above 90°C). Smart inbuilt controller shall have following features.
1.Control and monitor LED luminaries with bi directional control ( Status, Fault, Alarm, dimming level,
wattage, energy)
2. to measure voltage, current, power, power factor, apparent energy, active energy, operating hours.
3. Inbuilt ambient light sensor, motion sensor based on Passive Infra Red (PIR).
4. Wi-Fi LoRA/Zigbee/Powerline with ethernet network based IOT feature as per site requirement or engineer
5. should be controlled through auto/ manual
6. Programmable level of not less than 48 different light intensity Eachtings,
7. inbuilt repeater & relay signals function to other controllers
GRAND TOTAL 2,18,34,407.77
GRAND TOTAL 2,18,34,407.77
Digitally signed by MAYANK
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT MEA INA.pdf
Tender Document
GCC Contracting for Construction works 2026.pdf
Tender Document
SCC.pdf
Tender Document
LIST OF MAKE.pdf
Tender Document
Technical Specification.pdf
Tender Document
BOQ Barricading.pdf
Tender Document
Tender drawing.pdf
Tender Document
All Technical Circular.pdf
Tender Document
corrigendum-5249-Corregendum 03 MEA INA.pdf
pdf • 0.48 MB
corrigendum-5199-Corregendum 02 MEA INA.pdf
pdf • 0.49 MB
corrigendum-5178-Corregendum 01 MEA INA barricading.pdf
pdf • 1.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .