Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC 736 PARAGDAS MANDIR NIRMOCHAN GHAT AYODHYA 224123 | AYODHYA | AYODHYA | UTTAR PRADESH | 224123 | L1 | Accepted-AOC Tender Accepted | |
| 2 | L2₹29.5 L+₹1.2 L (4.12%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹30.5 L+₹2.2 L (7.85%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹35.4 L+₹7.1 L (25.0%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹35.9 L+₹7.6 L (26.9%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
23 Jun 2022, 6:00 pmClosed
GE Faizabad
GE MES Faizabad
REPAIR MAINT OF DG SETS PUMP MOTOR SUPPLY OF CHEMICALS AND ALLIED WORK UNDER AGE EM AT GE FAIZABAD
2022_MES_526561_1
8309/E8
Open Tender
Civil Works
Item Rate
180 days
Faizabad
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE Faizabad
₹84,000
Yes
5 Jul 2022
26 May 2022
24 Jun 2022
26 May 2022
23 Jun 2022
9 Jun 2022
Amount
Periodical maintenance for entire duration of contract including complete servicing of Diesel Engine Generator set of 160 KVA capacity at Military Hospital of make: Kirloskar or any other make as per site requirement and connected accessories including replacement of oil /lubricant filter to keep the plant in running condition including routine maintenance complete all as specified and as directed. [Note: (i) The Contractor need to get the job done through authorised service centre/ agency of Kirloskar Oil Engine Ltd or any other OEM (Original Equipment Manufacturer) located near Faizabad. The cost thereof deemed to be included in the quoted rate. (ii) All Spare parts for routine maintenence will be measured and paid separately under relevent items of this schedule as 'Supply Only' (iii) Labour charges for routine maintenance including properly dismantling of old parts deemed to be included in the quoted rate]
All as per item Ser No 1 here-in-before but of Diesel Engine Generator Set of 62.5/ 63 kVA capacity at Pump House No 1, 2, 3, 4, 5,6,7, 8, 9, 10, 11, 12, STP Himachal Niwas, STP Kandahar Line, Signal Centre, Amn Dump, Trolly Mounted
All as per item Ser No 1 here-in-before but of Diesel Engine Generator Set of 40 KVA capacity at Records
All as per item Ser No 1 here-in-before but of Diesel Engine Generator Set of 15 KVA capacity
Supply only Lubricant oil filter for routine maintenance of DG Set 160 KVA, complete all specified.
All as per item no.5 but Fuel filter (Pre)
All as per item no.5 but Fuel filter (Micro)
All as per item no.5 but Air filter outer
All as per item no.5 but Air filter inner
Supply only Lubricant oil filter for routine maintenance of 15-62.5 KVA DG Set complete all specified.
All as per item no.10 but Fuel filter (Pre)
All as per item no.10 but Fuel filter (Micro)
All as per item no.10 but Air filter outer
All as per item no.10 but Air filter inner
Supply only Coolant for DG Set
Supply only Lub Oil for DG Set of make Koel Care Premium Genuine
M&L for Head Gasket set (Cylinder head) of capacity 160 KVA DG set make: Kirloskar or equivalent all as specified and directed. [Labour charges for properly dismantling of old parts deemed to be included in the quoted rate]
All as per item no.17 but Valve Inlet-Exhaust
All as per item no.17 but Seat Inlet-Exhaust
All as per item no.17 but Valve Guide
All as per item no.17 but Valve Collet
All as per item no.17 but Valve Spring
All as per item no.17 but Piston Assembly
All as per item no.17 but Piston Ring set
All as per item no.17 but Cylinder linear
All as per item no.17 but O-Ring
All as per item no.17 but Tappet bush with packing
All as per item no.17 but Thermostat assembly
All as per item no.17 but Sealing ring set
All as per item no.17 but Rocker lever
All as per item no.17 but Rocker BRKT
All as per item no.17 but Push rod
All as per item no.17 but Push rod tube
All as per item no.17 but Alternator coupling
All as per item no.17 but Starter Ring
All as per item no.17 but Oil level pressure and level gauge/indicator
All as per item no.17 but Amp meter indicator for battery charging
All as per item no.17 but Digital panel board indicating volt,current,pf,kw
All as per item no.17 but CT 100/5
All as per item no.17 but ON/ Off push button set
All as per item no.17 but Cut out for charging alternator
All as per item no.17 but Ignition Switch for charging alternator
All as per item no.17 but Switch Plate for charging alternator
All as per item no.17 but Diode Plate forcharging alternator
All as per item no.17 but Carbon for charging alternator
All as per item no.17 but Bulb Holder for charging alternator
All as per item no.17 but Rectifier Assembly for charging alternator
All as per item no.17 but Brush Box Assembly for charging alternator
All as per item no.17 but Bearing for charging alternator
All as per item no.17 but Oil seal for charging alternator
All as per item no.17 but Field Coil for charging alternator
All as per item no.17 but Hose : Water Pump inlet to Radiator outlet
All as per item no.17 but Hose :Pipe to Water Pump
All as per item no.17 but Hose : Pipe to Diesal tank
All as per item no.17 but Hose pipe with 04 nos clip & nut
All as per item no.17 but Terminal block
All as per item no.17 but Fan Belt
All as per item no.17 but Automatic Voltage Regulator
All as per item no.17 but Water Pump Repair Kit
M&L for Head Gasket set (Cylinder head) of capacity 15-63 KVA DG set make: Kirloskar or equivalent all as specified and directed. [Labour charges for properly dismantling of old parts deemed to be included in the quoted rate]
All as per item no.60 but Valve Inlet-Exhaust
All as per item no.60 but Seat Inlet-Exhaust
All as per item no.60 but Valve Guide
All as per item no.60 but Valve Collet
All as per item no.60 but Valve Spring
All as per item no.60 but Piston Assembly
All as per item no.60 but Piston Ring set
All as per item no.60 but Cylinder linear
All as per item no.60 but O-Ring
All as per item no.60 but Tappet bush with packing
All as per item no.60 but Thermostat assembly
All as per item no.60 but Sealing Ring set
All as per item no.60 but Rocker lever
All as per item no.60 but Rocker BRKT
All as per item no.60 but Push rod
All as per item no.60 but Push rod tube
All as per item no.60 but Alternator coupling
All as per item no.60 but Starter Ring
All as per item no.60 but Expansion bellow
All as per item no.60 but Oil level pressure and level gauge/indicator
All as per item no.60 but Amp meter indicator for battery charging
All as per item no.60 but Digital panel board indicating volt,current,pf,kw
All as per item no.60 but CT 100/5
All as per item no.60 but ON/ Off push button set with wiring
All as per item no.60 but Cut out for charging alternator
All as per item no.60 but Ignition Switch for charging alternator
All as per item no.60 but Switch Plate for charging alternator
All as per item no.60 but Diode Plate forcharging alternator
All as per item no.60 but Carbon for charging alternator
All as per item no.60 but Bulb Holder for charging alternator
All as per item no.60 but Rectifier Assembly for charging alternator
All as per item no.60 but Brush Box Assembly for charging alternator
All as per item no.60 but Bearing for charging alternator
All as per item no.60 but Oil seal for charging alternator
All as per item no.60 but Field Coil for charging alternator
All as per item no.60 but Hose : Water Pump inlet to Radiator outlet
All as per item no.60 but Hose :Pipe to Water Pump
All as per item no.60 but Hose : Pipe to Diesal tank
All as per item no.60 but Hose pipe with 04 nos clip & nut
All as per item no.60 but Terminal block
All as per item no.60 but Fan Belt
All as per item no.60 but Automatic Voltage Regulator
All as per item no.60 but Water Pump Repair Kit
S&F stranded copper conductor battery lead 25 Sqmm for 24 volts DC grade red for (+)ve terminal and black for ( -)ve terminal i.e. 02 nos fitted with battery terminal at one end and battery lug at other end complete length 1.5 mtr, complete all as specified and directed.
M&L for Calibration of Fuel Injection Pump including properly dismantling and transporting to service center/workshop for over hauling/ calibration and refixing on DG Set after calibration for DG Sets of capacity 160 kVA including taking out of old one and with replacement of following items all as directed by Engr -in charge : a) Element - 06 Nos b) D.V - 06 Nos c) T.R.B - 06 Nos d) Bearing - 02 Nos e) C.R - 01 Nos f) C.R Bush - 02 Nos g) Ball Bearing - 01 Nos h) F.P.P - 01 Nos i) F.P Kit - 01 Nos j) Pressure Bolt - 06 Nos k)Nozzle seal - 02 Nos l) Nozzle setting - 06 Nos & with all other neessary items .
All as per item Ser No 105 above but for DG Sets of capacity 62.5/ 63 KVA
All as per item Ser No 105 above but for DG Sets of capacity 40 KVA
All as per item Ser No 105 above but for DG Sets of capacity 15 KVA
M&L for Banjo Bolt M 14 x 1.5 including taking out of old one.
M&L for Flexible fuel pipe type 7.5 14 x 14 B 700 PB of make: Kirloskar or equivalent including taking out of old one.
M&L for Fuel Pump mounted STOP solenoid switch suitable for 15 to 62.5-63 kVA DG set of make: Kirloskar or equivalent including taking out of old one.
M&L for servicing of radiator including cleaning and testing of leakages for DG set of capacity 160 KVA all as specified and as directedand [Note: - In case of leakages found during servicing, the same should be measured and paid separately ]
All as per item Ser No 112 above but for DG set capacity 15-63 KVA
Dismantling the radiator and transporting to workshop, repair of all leakage and transporting back and refitting in original position and testing for DG set of capacity 160 KVA all as specified and as directed
All as per item Ser No 114 above but for DG set capacity 15-63 KVA
M&L for Carefully dismantling the alternator of DG set capacity 160 KVA and transporting to workshop for repair and reffiting back the same in its original position after repair and testing complete all as specified and directed.
M&L for Carefully cutting out old burnt armature winding of alternator of DG set capacity 160 KVA, cleaning the slot of stator and rewinding the same with super enamelled copper winding wire of appropriate gauge complete with all insulating materials, nomex paper, copper tape, glass sleeve, soldering rod, grease etc. complete all as specified and directed.
All as per item Ser No 117 above but for field winding of alternator
All as per item Ser No 117 above but for exciter coil of alternator
M&L for Carefully dismantling the alternator of DG set capacity 40-63 KVA and transporting to workshop for repair and reffiting back the same in its original position after repair and testing complete all as specified and directed.
M&L for Carefully cutting out old burnt armature winding of alternator of DG set capacity 15-63 KVA, cleaning the slot of stator and rewinding the same with super enamelled copper winding wire of appropriate gauge complete with all insulating materials, nomex paper, copper tape, glass sleeve, soldering rod, grease etc. complete all as specified and directed.
All as per item Ser No 121 above but for field winding of alternator
All as per item Ser No 121 above but for exciter coil of alternator
All as per item Ser No 121 above but damaged ball bearing(S.K.F.)
M&L for Carefully dismantling the alternator of DG set capacity 15 KVA and transporting to workshop for repair and reffiting back the same in its original position after repair and testing complete all as specified and directed.
M&L for Carefully cutting out old burnt armature winding of alternator of DG set capacity 15 KVA, cleaning the slot of stator and rewinding the same with super enamelled copper winding wire of appropriate gauge complete with all insulating materials, nomex paper, copper tape, glass sleeve, soldering rod, grease etc. complete all as specified and directed.
All as per item Ser No 126 above but for field winding of alternator
All as per item Ser No 126 above but for exciter coil of alternator
All as per item Ser No 126 above but damaged ball bearing(S.K.F.)
M&L for Carefully dismantling the fuel tank and transporting to workshop, repair of all leakage, cleaning and transporting back and refitting in original position and testing after completion for DG set of capacity 160 KVA all as specified and as directed including taking out of old one.
All as per item Ser No 130 above but for DG set capacity 15-63 KVA
M&L for Carefully cleaning of fuel tank for DG set of capacity 160 KVA all as specified and as directed including taking out of old one.
All as per item Ser No 132 above but for DG set capacity 15-63 KVA
S&F self starter of DG set of capacity 160 KVA 12/24 volts of any make and model compatible with the existing one all as specified and directed .
All as per item Ser No 134 above but for DG Sets of capacity 62.5/ 63 KVA
All as per item Ser No 134 above but for DG Sets of capacity 40 KVA
All as per item Ser No 134 above but for DG Sets of capacity 15 KVA
M&L for Carefully dismantling the self starter of DG set capacity 62.5/63 KVA and transporting to workshop and reffiting back after repair with replacement / repair of following items :
Supply only Carbon bush with spring materials for repair of self starter of DG set capacity 15-160 KVA , complete all specified.
All as per item Ser No 139 but GM Bush set
All as per item Ser No 139 but Bendex Pinion
All as per item Ser No 139 but Solenoid Switch
All as per item Ser No 139 but Armature Rewinding
All as per item Ser No 139 but Field Coil set
Supply only lead acid battery 12 volt 180 Ah including initial charge of make: Exide or equivalent complete all as directed by Engr-In-Charge
M&L Earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6.0 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, connected with GI strip 25x4mm by means of bolts , nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI strip is connected to main switch board and protected by light grade GI pipe of 15 mm bore. provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horizontally to the equipment. Cement concrete chamber of PCC ( 1:3:6 ) type C-2 using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate, excavation in soft / loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009).
Supply only earth lead GI strip 25x4mm complete all as specified and directed
S & F MCCB 3 pole 100 Amp, 415 volt, 10-25 KA of make: L&T or equivalent in C&S, Scheinider,siemens in existing panel including taking out of old one all as specified and as directed
S & F MCCB 4 pole 100 Amp, 415 volt, 10-25 KA of make: L&T or equivalent in C&S, Scheinider,siemens in existing panel including taking out of old one all as specified and as directed
S & F On load Changeover 4 pole 100 Amp, 415 volt, in sheet steel enclosure type of make: L&T or equivalent including taking out of old one all as specified and as directed
S & F On load Changeover 4 pole 100 Amp, 415 volt, open execution type of make: L&T or equivalent in C&S, Scheinider,siemens in existing panel including taking out of old one all as specified and as directed
S & F Single phase Preventer Relay with adjustable time delay 30 sec to 5 min suitable for 415 volt AC, any type of make: L&T or equivalent including internal wiring from switchgear to relay in existing panel all as specified and as directed
M&L for fixing of DOL starter three phases 415 Volt for 2.5 HP electric motor including all fixing materials all as directed.
M&L for fixing of DOL starter three phases 415 Volt for 7.5 HP electric motor including all fixing materials all as directed.
M&L for fixing of DOL starter three phases 415 Volt for 10 HP electric motor including all fixing materials all as directed.
M&L for fixing of DOL starter three phases 415 Volt for 20 HP electric motor including all fixing materials all as directed.
Supply & Fixing of Flat three core submersible cable PVC insulated and sheathed multistranded copper conductor of cross sectional area 16 sqmm of make: Havells , Kalinga ,Polycab or equivalent .
S&F FR PVC Insulated Single core unsheathed Industrial Flexible cable of size 16 sqmm conforming to IS 694:2010 with bright annealed copper conductor in existing panel including taking out of old one all as specified and as directed . Make : Polycab or equivalent .
Supply only bleaching powder in 25 Kg bag (ISI marked) grade II all as specified and directed by Engr-In-Charge (Make: Punjab Alkalies/Modi Alkalies/Sriram as approved).
Supply only sodium hypochloride liquid (chlorine content 10%) duly packed in sealed drum of make: M/s Declibac/ M/s Rayalshima Enterprise/ Birla Chemicals or equivalent all as specified and as directed.
Supply only white crystal alum ferric of superior quality duly packed, complete all as specified.
Supply only copper sulphate blue crystal of superior quality duly packed complete all as specified.
Supply only soda ash of superior quality complete all as specified.
Repair and maintenance of suction sweeper comprising 600mm long MS/ CI fabricated suction head with PVC wheels, spring loaded brush and fibber squeezer including trolley mounted electric driven non clog self priming type centrifugal pumping set with 02 HP Motor 03 phase , 415 V electric driven DOL Push button starter along with repair to minor defects such as repair/ replacement to electric contact, kit-kat fuse, pumping set gland rope, coupling nuts & bolts, bush/ thrust bearing of existing size , push button, contactor block & relay of starter ,oiling/ greasing and testing etc complete including painting with two coat of synthetic enamel paint -of existing colour after removal of old paint / cleaning to rusted/ corrosive portion - 04 Sets [Note:- (i) All type of T&P main switch ,electric multi meter/ tong tester for fault detecting , etc required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate. (ii) If item of work is not got executed for any of the suction sweeper-machine , price adjustment shall be made based on the proportional rate worked out from unit quoted rate for the item of work. (iii) Supply of major items required for repair/replacement shall be measured and paid separately under relevant item of this schedule as 'supply only']
Supply only Nylon-Rope size (14 -20) mm dia suction sweeper , complete all specified.
Supply only PVC suction hose / pipe, green (1-2" ultra Light & flexible with PVC spiral ribbed for extra strength) with 2 male connector nipplesplus clamps (4 Nos.) complete all as specified and directed
S & F Spire Brush suitable for Cleaning of swimming pool, complete all specified.
S & F PVC wheel with bush and nut bolt set of 04 nos suitable for suction sweeper machine all as specified and directed by Engr-In-Charge
Supply and fixing PVC Floats suitable for Swimming pool including taking out of old one
Collection of water samples of bore wells located in deferent pockets of cantonment area in decontaminated sterilised bottles and testing of water samples for following essential parameters for drinking water as per IS:10500- 2012 from Govt Lab or NABL accredited laboratory: - (i) Colour (ii) odour (iii) taste (iv) pH value, (v) Turbidity (vi) TDS (vii) Total arsenic (viii) Silica (ix) Fluoride (x) Iron (xi) Magnesium (xii) Sulphate (xiii) Total Hardness (xiv) Total alkalinity (xv) Calcium (xvi) Conductivity (xvii) Chloride (xviii) Total Coliform and (xix) E Coli all as specified and as directed.
M&L for Rolled mild steel in Joist ,channel,angle, or tee sections, fixed independently, without connecting plates, etc. for repair to staircase,hand rails and back rest of over head reservoir or as otherwise directed. [Note: All T&P and labour charges for working on OH tanks upto 21 mtr high staging deemed to be included in the quoted rate]
Lifting of defective submersible pump set any make & model of capacity 25 HP to 45 HP from deep well 350mm housing along with connected accessories such as column pipe of 150mm dia appx 30 m submersible cable, steel pipe, spider, sleeve, line shaft, nut, bolts etc complete all as specified and directed by Engr-In-Charge. [Note:- (i) All type of T & P, chain pulley & tripod etc required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate (ii) The Contractor will start the lifting work with in minimum time after getting message verbally/telephonically by JE E/M/AGE E/M. (iii) A penalty of Rs. 500/- per day will be imposed on the Contractor for wilful delay by the Contractor will be imposed as per opinion of Engineer-in-Charge and amount will be deducted from the due payment of the Contractor]
Transportation including loading & unloading of defective submersible pump set 3 phase any make and capacity 25 to 45 HP from pump house to work shop for necessary repair and transporting back to the pump house including carefully loading & unloading of pump set after repair complete all as specified and directed by Engr-In-Charge.
Dismantling of defective submersible pump set any make & model of capacity 25 HP to 45 HP, repairing the same including replacing old unserviceable parts and re-assembling and testing after repair complete all as specified and directed by Engr-In-Charge. [Note: (i) All the spares required for repair will be measured and paid seperately as supply only. (ii) Greasing of moving parts deemed to be included in the quoted rate]
Supply only CI/ MS bowl (As per existing size) for submersible pump capacity 25 HP to 45 HP any make & model complete all as specified .
All per item no.175 but Stainless steel shaft with key
All per item no.175 but Gun Metal Bush
All per item no.175 but Stainless steel sleeve
All per item no.175 but Sand Guard
All per item no.175 but Impeller lock with key
All per item no.175 but Neck ring (as per existing size and type)
All per item no.175 but Turning & polishing of Pump shaft (lathe work)
Supply only Stainless Steel thrust bearing. parts for submersible motor of capacity 25 HP to 45 HP any make & model complete all as specified .
All per item no.183 but Carbon plate.
All per item no.183 but Rotor Gun Metal/steel bush
All per item no.183 but Rubber bush
All per item no.183 but Upper housing
All per item no.183 but Lower Housing
All per item no.183 but Turning, polishing of Rotor & shaft (Lathe work)
Rewinding of submersible motor capacity 25 HP to 45 HP any make & model with super enamelled copper wire of existing size including removal of existing burnt winding, cleaning of slots including packing material, connection and testing complete.
M&L for painting to pump set with two coat of synthetic enamel paint (grey colour) over a coat of red oxide primer after preparation of surface complete all as specified and directed by Engr-In-Charge.
Lowering, connecting, commissioning testing of repaired submersible set any make and capacity 25 HP to 45 HP 3 phase 415V into bore well 300/200mm with connected items such as column pipe approx 40 RM, properly connecting submersible cable etc complete all as specified and directed by Engr-In-Charge by Engineer-in-Charge. [Note:- (i) All type of T & P, chain pulley & tripod etc required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate (ii) The Contractor will start the lifting work with in minimum time after getting message verbally/ telephonically by JE E/M/ AGE E/M. (iii) A penalty of Rs. 500/- per day will be imposed on the Contractor for wilful delay by the Contractor will be imposed as per opinion of Engineer-in-Charge and amount will be deducted from the due payment of the Contractor]
Complete servicing of Fire fighting pump set any make & model of capacity 60 HP including replacement of minor spares and testing after servicing complete all as specified and directed by Engr-In-Charge. [Note: (i) Greasing of moving parts deemed to be included in the quoted rate (ii) All type of T&P main switch ,electric multi meter/ tong tester for fault detecting , etc required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate.
Supply only rubber packing 6mm thick consisting of 8/6" holes for 100mm to 150 mm dia column pipe complete all as specified and directed by Engr-In-Charge.
Repair and maintenance of defective Monoblock motor pump any make & model of capacity 20 HP including required repairing like motor rewinding, replacement of minor spares like Motor bearing, Gland packing, Fan motor blade, Packing paper, Water seal, Starting Coil, Motor housing, S.S . sleeve repairing on Lathe ,Impeller Brass, Gun Metal Bush, Rubber Coupling belt, Rubber bush, Rubber gasket, nut bolt & any other minor connected items and testing after repairing including painting complete all as specified and directed by Engr-In-Charge. [Note: All type of T&P including dismantling and fixing required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate.]
Repair and maintenance of defective Monoblock motor pump any make & model of capacity 10 HP including required repairing like motor rewinding, replacement of minor spares like Motor bearing, Gland packing, Fan motor blade, Packing paper, Water seal, Starting Coil, Motor housing, S.S . sleeve repairing on Lathe ,Impeller Brass, Gun Metal Bush, Rubber Coupling Set, Rubber bush, Rubber gasket, nut bolt & any other minor connected items and testing after repairing including painting complete all as specified and directed by Engr-In-Charge. [Note: All type of T&P including dismantling and fixing required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate.]
Repair and maintenance of defective Monoblock motor pump any make & model of capacity 7.5 HP including required repairing like motor rewinding, replacement of minor spares like Motor bearing, Gland packing, Fan motor blade, Packing paper, Water seal, Starting Coil, Motor housing, S.S . sleeve repairing on Lathe ,Impeller Brass, Gun Metal Bush, Rubber Coupling Set, Rubber bush, Rubber gasket, nut bolt & any other minor connected items and testing after repairing complete all as specified and directed by Engr-In-Charge. [Note: All type of T&P including dismantling and fixing required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate.]
Repair and maintenance of defective Monoblock motor pump any make & model of capacity upto 2.5 HP including required repairing like motor rewinding, replacement of minor spares like Motor bearing, Gland packing, Fan motor blade, Packing paper, Water seal, Starting Coil, Motor housing, S.S . sleeve repairing on Lathe ,Impeller Brass, Gun Metal Bush, Rubber Coupling Set, Rubber bush, Rubber gasket, nut bolt & any other minor connected items and testing after repairing including painting complete all as specified and directed by Engr-In-Charge. [Note: All type of T&P including dismantling and fixing required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate.]
Taking out steel water tubing/ UPVC for 20 mm bore size including fittings complete all as specified and directed.
S & F Unplasticised PVC pipes Sch 40 of fixed complete to walls, ceilings or in floors etc., any type of pipe for 15 mm bore sizes make: ISI Marked best quality etc complete all as specified and directed.
Complete servicing of servo voltage stabilizer of 50 KVA of make: Servostar / Vinitec or any other make as per site requirement and connected accessories including replacement of defected old parts, oil / lubricant to keep the plant in running condition including routine maintenance complete all as specified and as directed. [Note: (i) The Contractor need to get the job done through authorised service centre/ agency of OEM (Original Equipment Manufacturer).The cost thereof deemed to be included in the quoted rate. (ii) All Spare parts for routine maintenence will be measured and paid separately under relevent items of this schedule as 'Supply Only' (iii) Labour charges for routine maintenance including properly dismantling of old parts deemed to be included in the quoted rate]
Supply only Variac for routine maintenance of servo voltage stabilizer 50 KVA capacity complete all specified.
All as per item no.202 but servo motors (3 Kg)
All as per item no.202 but RC Network (3 Kg)
All as per item no.202 but Sensor Transformer 8/16V (Triggar)
All as per item no.202 but 2 K Pot
All as per item no.202 but PCB Digital Card (Double Display)
All as per item no.202 but Carbon Brush
All as per item no.202 but Voltmeter
All as per item no.202 but Micro Switch
All as per item no.202 but SPDT & DPDT Switches
All as per item no.202 but Buck Boost Transformer
All as per item no.202 but Motorised Plate
All as per item no.202 but Front Plate Variac
All as per item no.202 but Armer of Variac
All as per item no.202 but Variac Base
All as per item no.202 but Strip 30 Amp
All as per item no.202 but Spring
All as per item no.202 but Hexa
All as per item no.202 but Stopper
All as per item no.202 but Relay 5 Amp
All as per item no.202 but Push Button
All as per item no.202 LED (Green,Yellow,Red)
All as per item no.202 PCB Card (High & Low Cut Off)
All as per item no.202 Transformer Oil
Shree Kanth Technologies
His And Her Enterprises
Khan Brothers
PITAMBARI TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .