Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Techno-Commercially qualified |
| 2 | Accepted-Technical | Accepted-Technical Techno-commercially Qualified |
| 3 | Accepted-Technical | Accepted-Technical Techno-Commercially qualified |
| 4 | Rejected-Technical | Rejected-Technical Techno-Commercially disqualified |
| 5 | Rejected-Technical | Rejected-Technical Techno-Commercially disqualified |
Tender Value
₹19.7 L
EMD Value
₹39,000
Closing Date
3 Jan 2026, 4:30 pmClosed
Deputy General Manager, Contract and Procurement
Admin Building, Indira Sagar Power Station, Narmada Nagar, Distt. Khandwa, Pin code 450119
Development of existing Herbal Park near Project Hospital at Indira Sagar Power Station, Narmada Nagar, Distt. Khandwa (M.P.).
2025_NHDC_886777_1
NIT NO. 18/3659/2025-26 DATED 21-11-2025
Open Tender
Civil Works
Percentage
120 days
Indira Sagar Power Station, Narmada Nagar
As per tender documents
3 documents required · 3 mandatory
₹590
NHDC Limited
₹39,000
Yes
10 Mar 2026
22 Nov 2025
6 Jan 2026
22 Nov 2025
3 Jan 2026
22 Nov 2025
22 Nov 2025 - 6 Dec 2025
Surface dressing of the ground including removing vegetation and in equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. in all kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : With 20mm nominal size graded stone aggregate. M-10 Nominal (Mix-1 Cement : 3 sand : 6 graded stone aggregate )
Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for concrete upto plinth level
Centering and shuttering in cluding strutting, propping etc. and removal of form for: Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. Uptoplinthlevel.
Centering and shuttering in cluding strutting, propping etc. and removal of form for: Columns, Pillars , Piers, Abutments, Posts and Struts.
Centering and shuttering in cluding strutting, propping etc. and removal of form for: Small lintels not exceeding 1.5m clear span, mouldingas incornices, window, sills, courses, bands, copings, bed plates, anchor blocks and the like.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : M-15 – Grade concrete
Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : M-20 Grade Concrete
Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and upto floor two level excluding cost of centering, shuttering, finishing and reinforcement: M-20 Grade Concrete
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto floor two level, excluding the cost of centering, shuttering and finishing : With 20mm nominal size graded stone aggregate M 20 – Grade concrete
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS-456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . (Note:- 1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers. 3. Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”) Thermo-Mechanically Treated bars. FE 500 conforming to IS 1786
Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cm depth and dressing complete.
Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor two level in : Having 50 kg / cm2 average compressive strength. Cement mortar 1:6 (1 cement : 6 sand)
12 mm cement plaster of mix :1:4 (1 cement : 4 sand)
6 mm cement plaster of mix : 1:3 (1 cement : 3 sand)
Providing and laying factory made machine pressed precast cement concrete interlocking paver block of any shape and size conforming to IS:15658- 2006 and ISI marked of 60 mm thickness, M-30 grade with grey cement and pigment all as specified. Made by block making machine with strong vibratory compaction, laid in required colour andpattern over and including 50mm thick compacted bed of stone dust, filling the jointswith sand etc. all complete as per thedirection of Engineer-in- Charge.
Structural steel work using M.S. flats, angles, channels I-section, H-section etc. riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
Wall painting by any mechanical or manual means with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand andmanufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats
stage.html
html • 0.03 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.60 MB
18Tender3659.pdf
Tender Documents • 6.97 MB
BOQ_932103.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .