| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | ₹23.1 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹25.4 L+₹2.2 L (9.68%)Rejected-AOC 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | ₹25.4 L+₹2.2 L (9.68%) | L2 | Rejected-AOC Being L2 |
| 3 | L3₹37.8 L+₹14.6 L (63.2%)Rejected-AOC | ₹37.8 L+₹14.6 L (63.2%) | L3 | Rejected-AOC Being L3 |
| 4 | L4₹37.9 L+₹14.8 L (63.9%)Rejected-AOC C O M KHARKARANG LUMJINGSUK BLOCK A MADANRTING SHILLONG 793021 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793021 | ₹37.9 L+₹14.8 L (63.9%) | L4 | Rejected-AOC Being L4 |
| 5 | L5₹38.1 L+₹14.9 L (64.5%)Rejected-AOC | ₹38.1 L+₹14.9 L (64.5%) | L5 | Rejected-AOC Being L5 |
| Sl No | Description | Qty | Unit | R. S. Associates L1 | M/S TAPAN KUMAR RAY L8 | MS AFTAB LASKAR L3 | M/S Goutam Chakraborty L5 | M/S SANJIB DEB L10 | m/s builders and suppliers L9 | Bhuiya Construction L4 | Anup Kumar Paul Choudhury L11 | Vijaypower Generators Limited L2 | M/S LUIT CONSTRUCTION L6 | SHRI YOUNUS KHAN L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00E & M Division Items | ||||||||||||||
| 2.00 | Supply, installation, testing and commissiong of Retrofit Emission Control Device (RECD) having regenerative technology with a PPM 2.5 capturing and reduction ability of 80-94% in DG sets of capacity 125KVA any make, modal complete all as specified and directed | 4 | Each Job | 2,99,000 ₹11,96,000 Lowest | 5,20,000 ₹20,80,000 | 5,15,000 ₹20,60,000 | 4,90,000 ₹19,60,000 | 5,50,000 ₹22,00,000 | 5,45,000 ₹21,80,000 | 4,95,000 ₹19,80,000 | 5,56,000 ₹22,24,000 | 3,16,000 ₹12,64,000 | 4,95,000 ₹19,80,000 | 5,05,000 ₹20,20,000 |
| 3.00 | Supply, installation, testing and commissiong of Retrofit Emission Control Device (RECD) having regenerative technology with a PPM 2.5 capturing and reduction ability of 80-94% in DG sets of capacity 62.50KVA any make, modal complete all as specified and directed | 2 | Each Job | 2,28,000 ₹4,56,000 | 3,50,000 ₹7,00,000 | 3,25,000 ₹6,50,000 | 3,80,000 ₹7,60,000 | 3,35,000 ₹6,70,000 | 3,25,000 ₹6,50,000 | 3,35,000 ₹6,70,000 | 3,22,000 ₹6,44,000 | 2,25,000 ₹4,50,000 Lowest | 3,35,000 ₹6,70,000 | 3,50,000 ₹7,00,000 |
| 4.00 | Supply, installation, testing and commissiong of Retrofit Emission Control Device (RECD) having regenerative technology with a PPM 2.5 capturing and reduction ability of 80-94% in DG sets of capacity 40 KVA any make, modal complete all as specified and directed | 1 | Each Job | 1,90,000 ₹1,90,000 Lowest | 3,00,000 ₹3,00,000 | 2,90,000 ₹2,90,000 | 2,95,000 ₹2,95,000 | 3,00,000 ₹3,00,000 | 3,12,000 ₹3,12,000 | 3,25,000 ₹3,25,000 | 3,10,000 ₹3,10,000 | 2,15,000 ₹2,15,000 | 3,25,000 ₹3,25,000 | 3,15,000 ₹3,15,000 |
| 5.00 | Supply, installation, testing and commissiong of Retrofit Emission Control Device (RECD) having regenerative technology with a PPM 2.5 capturing and reduction ability of 80-94% in DG sets of capacity 30KVA any make, modal complete all as specified and directed | 2 | Each Job | 1,75,000 ₹3,50,000 Lowest | 2,85,000 ₹5,70,000 | 2,85,000 ₹5,70,000 | 2,90,000 ₹5,80,000 | 2,95,000 ₹5,90,000 | 3,05,000 ₹6,10,000 | 3,00,000 ₹6,00,000 | 3,04,000 ₹6,08,000 | 1,94,000 ₹3,88,000 | 3,10,000 ₹6,20,000 | 3,05,000 ₹6,10,000 |
| 6.00Note: The following parameter shall be applicable for the above mentioned items No 2 to 5:- | ||||||||||||||
| 6.10(i) Diesel Particulate Filter(DPF) (ii) Diesel Oxidation Catalyst(DOC) (iii) Selective Reducation Catalyst (SRC) (iv) the RECD must be equipped with auto bypass system for back pressure to ensure ZERO DOWN TIME of External Panel displaying temperature and pressure levels of RECD alongwith visible alarm system. the DG Set and also have an option cloud based data availability to effective monitor the effiency of the device remotely (v) Location of works are in Bhaga Pump house, Lailapur and CIJWS VAIRENGTE (vi) All arragement of like tools, transport, loading/unloading by the Contractor no extra will be pay | ||||||||||||||
| 6.20Application: - Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine. a) Min Particular Matter Reduction 85% b) Min Carbon Monoxide Reduction 90% c) Min Hydrocarbon Reduction 90% Application: - Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine. a) Min Particular Matter Reduction 85% b) Min Carbon Monoxide Reduction 90% c) Min Hydrocarbon Reduction 90% | ||||||||||||||
| 6.30Technology/Type: - ESP (Electrostatic Precipitator), Wet Scrubbing, Diesel Oxides Catalyst a) Guaranteed specified Particulate matter (PM 2.5) b) Carbon Monoxide, Hydrocarbon reduction efficiency c) Retrofit device is to be installed in place of existing silencer. d) No soot is to be collected in the retrofit device. e) The device including enclosure should include an Oxidation chamber and Passive Regeneration Trap. f) Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM (as per the capacity of the DG set) should be under limit and display panel to be provided for Back pressure and exhaust temperature limit. (g) The Retrofit emission control device shall be with corrosion resistive and heat resistance paint. (h) Standard set of tools consisting of a set of 3 spanners, one screw driver, one standard plier and one nose plier of appropriate size shall be provided along with each Retrofit Emission Control Device (RECD). (Note : Retrofit Emission Control Device (RECD) shall comply all norms as per latest applicable CPCB guideline. | ||||||||||||||
| 6.40TEST REPORTS Certification :- Device should be ‘Type Approved’ as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, wide Pollution Control Series PCLS/12/2021-22. Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the Central Pollution Control Board, Govt, of India, recognized/approved test agencies/laboratories as givenas per HQ E-in-C Br policy letter No. A/37696/Gen/Pol/E2W (PPC) date 29 jun 2024 and bidder will submit RECD tested report from following CPCB recognized approved labs:- (a) Automotive Research Association of India (ARAI, Pune Maharastra) (b) International centre for automotive Testing (ICAT, Manesar) (c) Indian Oil corporation research and development centre faridabad haryana (d) Indian Institute of petroleum dehradun (UK) (e) Vehicle Research Development Establishment (VRDE, Ahmednagar) NOTE: It is mandatory to the Type approval certificate for suitable KVA RATINGS (ENGINE FAMILY) with registration number & date (from one of the CPCB recognized approved lab shall be produce before commence of the work. | ||||||||||||||
Tender Value
₹34.1 L
EMD Value
₹68,200
Closing Date
23 Mar 2026, 6:00 pmClosed
GE SILCHAR
Office of the GE Silchar
SUPPLY INSTLN AND TESTING OF RETROFIT EMISSION CONTROL DEVICE (RECD) IN DG SETS OF AGE VAIRENGTE UNDER GE SILCHAR
2026_MES_754900_1
8126A/E8
Open Tender
Civil Works
Item Rate
180 days
Vairengte
Class D Category b i and other criteria as per NIT and Tender Doc
8 documents required · 8 mandatory
₹500
₹68,200
Yes
11 May 2026
2 Mar 2026
26 Mar 2026
2 Mar 2026
23 Mar 2026
16 Mar 2026
2 Mar 2026 - 9 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1E & M Division Items | |||||
| 2 | Supply, installation, testing and commissiong of Retrofit Emission Control Device (RECD) having regenerative technology with a PPM 2.5 capturing and reduction ability of 80-94% in DG sets of capacity 125KVA any make, modal complete all as specified and directed | 4 | Each Job | - | - |
| 3 | Supply, installation, testing and commissiong of Retrofit Emission Control Device (RECD) having regenerative technology with a PPM 2.5 capturing and reduction ability of 80-94% in DG sets of capacity 62.50KVA any make, modal complete all as specified and directed | 2 | Each Job | - | - |
| 4 | Supply, installation, testing and commissiong of Retrofit Emission Control Device (RECD) having regenerative technology with a PPM 2.5 capturing and reduction ability of 80-94% in DG sets of capacity 40 KVA any make, modal complete all as specified and directed | 1 | Each Job | - | - |
| 5 | Supply, installation, testing and commissiong of Retrofit Emission Control Device (RECD) having regenerative technology with a PPM 2.5 capturing and reduction ability of 80-94% in DG sets of capacity 30KVA any make, modal complete all as specified and directed | 2 | Each Job | - | - |
| 6.1 | (i) Diesel Particulate Filter(DPF)
(ii) Diesel Oxidation Catalyst(DOC)
(iii) Selective Reducation Catalyst (SRC)
(iv) the RECD must be equipped with auto bypass system for back pressure to ensure ZERO DOWN TIME of External Panel displaying temperature and pressure levels of RECD alongwith visible alarm system. the DG Set and also have an option cloud based data availability to effective monitor the effiency of the device remotely
(v) Location of works are in Bhaga Pump house, Lailapur and CIJWS VAIRENGTE
(vi) All arragement of like tools, transport, loading/unloading by the Contractor no extra will be pay | - | - | - | - |
| 6.2 | Application: - Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine.
a) Min Particular Matter Reduction 85%
b) Min Carbon Monoxide Reduction 90%
c) Min Hydrocarbon Reduction 90%
Application: - Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine.
a) Min Particular Matter Reduction 85%
b) Min Carbon Monoxide Reduction 90%
c) Min Hydrocarbon Reduction 90% | - | - | - | - |
| 6.3 | Technology/Type: - ESP (Electrostatic Precipitator), Wet Scrubbing, Diesel Oxides Catalyst
a) Guaranteed specified Particulate matter (PM 2.5)
b) Carbon Monoxide, Hydrocarbon reduction efficiency
c) Retrofit device is to be installed in place of existing silencer.
d) No soot is to be collected in the retrofit device.
e) The device including enclosure should include an Oxidation chamber and Passive Regeneration Trap.
f) Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM (as per the capacity of the DG set) should be under limit and display panel to be provided for Back pressure and exhaust temperature limit.
(g) The Retrofit emission control device shall be with corrosion resistive and heat resistance paint.
(h) Standard set of tools consisting of a set of 3 spanners, one screw driver, one standard plier and one nose plier of appropriate size shall be provided along with each Retrofit Emission Control Device (RECD).
(Note : Retrofit Emission Control Device (RECD) shall comply all norms as per latest applicable CPCB guideline. | - | - | - | - |
| 6.4 | TEST REPORTS Certification :-
Device should be ‘Type Approved’ as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, wide Pollution Control Series PCLS/12/2021-22. Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the Central Pollution Control Board, Govt, of India, recognized/approved test agencies/laboratories as givenas per HQ E-in-C Br policy letter No. A/37696/Gen/Pol/E2W (PPC) date 29 jun 2024 and bidder will submit RECD tested report from following CPCB recognized approved labs:-
(a) Automotive Research Association of India (ARAI, Pune Maharastra)
(b) International centre for automotive Testing (ICAT, Manesar)
(c) Indian Oil corporation research and development centre faridabad haryana
(d) Indian Institute of petroleum dehradun (UK)
(e) Vehicle Research Development Establishment (VRDE, Ahmednagar)
NOTE: It is mandatory to the Type approval certificate for suitable KVA RATINGS (ENGINE FAMILY) with registration number & date (from one of the CPCB recognized approved lab shall be produce before commence of the work. | - | - | - | - |
| 6.5 | General Technical Requirements (GTR) / Commissioning: -
a) Emission Control retrofit device shall be complete with safety precautions to ensure no damage should be done to the DG set operations under any circumstances. The Emission Control retrofit device should be closely coupled with the DG exhaust to ensure 100% of the exhaust passes through the Emission Control retrofit device.
b) Anti-Vibration mountings shall be provided for complete Emission Control retrofit device in case of flexible coupling with the diesel generator exhaust.
c) Emission Control retrofit device should have protection against under voltage, over voltage, under frequency, over frequency, low battery voltage, over current, earth-fault, short circuit, phase sequence change etc.
d) The Emission Control retrofit device shall be with corrosion resistive and HR paint.
e) Unloading and placement of the Emission Control retrofit device at the time of delivery is in the scope of buyer. The consignee shall ensure that the site is located along a motorable way.
f) The seller shall provide the trial run (Testing) of Emission Control retrofit device. The seller shall conduct trial run of the Emission Control retrofit device with the available electrical load at site. The trial run shall be for TWO hours. The electrical loading shall not be more than the rated capacity of the DG set.
g) Exhaust piping, extra civil work, distribution board shall be provided by the seller | - | - | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
8126A-TP.pdf
Tender Documents • 0.39 MB
BOQ_845503.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .