| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹27.1 LAccepted-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹38.5 L+₹9.6 L (33.2%)Rejected-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L-2 | Rejected-AOC L-2 |
Tender Value
₹42.5 L
EMD Value
₹85,100
Closing Date
26 Dec 2023, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR/MAINT OF EXTERNAL ELECTRIFICATION, MAINT OF TRANSFORMER, VCB AND LT UG CABLE AND ALLIED WORKS IN CFEES, RAC UNDER ZONE B AND REPAIR/MAINT OF FAN/METER/GEYSER AND OTHER CONNECTED WORKS AT ZONE A UNDER GE I RND DELHI
2023_MES_629639_1
GE/RND-78/DLI/2023-2024
Open Tender
Civil Works
Item Rate
240 days
DELHI
Class-D, Cat-b(i),b(ii)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹85,100
Yes
23 Feb 2024
23 Nov 2023
28 Dec 2023
23 Nov 2023
26 Dec 2023
7 Dec 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth in soft/loose soil for laying of cables, bricks pipe etc and getting out complete all as specified and directed.
All as per item Ser No 1.00 above but in hard/dense soil.
All as per item Ser No 1.00 above but in soft/disintegrated rock.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specified and directed.
Removal of excavated material (soil/disintegrated rock) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
M&L in replacement reinforced concrete pipes for cable protection, class NP2 of dia 100 mm, 2 nos half round (for bottom and top) complete all as specified and directed. Note :- Before laying of pipe the excavated portion shall be levelled to a true strata.
Material and Labour for earthing complete with iron earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 32x6 mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI strip of size 32mm x 6mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32x6 galvanized iron strip, complete all as specified and directed.
Supply and laying in trenches burnt brick sub class 'B' standard size for cable protection keeping width of the brick parallel to the length of the cable complete all as specified and directed.
Supply and laying un-reinforced factory made precast concrete cable cover, class HV, type 1, flat size-300x180x40 mm complete all as specified and directed.
Supply and spread clean dry river sand in trenches ,ducts including leveling, punning for cushioning of cables complete all as specified and directed. Note :- Punned thickness of sand cushioning shall be measured.
S&F MCCB 630 Amps 4 Pole breaking capacity 50 KA including taking down old burnt MCCB complete all as specified and directed.
S&F MCCB 400Amps 4 Pole breaking capacity 36KA including taking down old burnt MCCB complete all as specified and directed.
S&F MCCB 250Amps 4 Pole breaking capacity 36KA including taking down old burnt MCCB complete all as specified and directed.
S&F MCCB 160 Amps 4 Pole breaking capacity 25KA including taking down old burnt MCCB complete all as specified and directed.
S&F MCCB 125 Amps 3 Pole breaking capacity 16KA including taking down old burnt MCCB complete all as specified and directed.
S&F MCCB 63/100Amps 3 Pole breaking capacity 16KA including taking down old burnt MCCB complete all as specified and directed.
S&F in repair jointing kit for 11 KV ( earthed) grade cable indoor type for end termination, heat shrinkable of size 50 to 95 sq mm conforming to IS - 7098 part-II including thimbling, nut/bolts & washers, HV insulating tape etc, complete all as specified and directed.
S&F in repair jointing kit for 11 KV ( earthed) grade cable indoor type for end termination, heat shrinkable of size 95 to 185 sq mm conforming to IS - 7098 part-II including thimbling, nut/bolts & washers, HV insulating tape etc, complete all as specified and directed.
S&F in repair straight through joint 11 KV heat shrinkable of size upto 95 sq mm conforming to IS - 7098 part-II including thimbling, nut/bolts & washers, HV insulating tape etc, complete all as specified and directed.
S&F in repair straight through joint 11 KV heat shrinkable of size 120 to 185 sq mm conforming to IS - 7098 Part-II including thimbling, nut/bolts & washers, HV insulating tape etc, complete all as specified and directed.
Supply and laying in replacement XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 150 Sqmm 3 core complete all as specified and directed.
Supply and laying in replacement XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 120 Sqmm 3 core complete all as specified and directed.
Supply and laying in replacement XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 95 Sqmm 3 core complete completed all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregates) for repairing of LT pole/ panel foundation etc including filling in road cuts/hard standing etc complete all as specified and directed.
M&L for PCC 1:4:8 type D-1 (using 40 mm graded stone aggregates) for repairing of LT pole/ panel foundation etc including filling in road cuts/hard standing etc complete all as specified and directed.
Supply, laying, testing and commissionnig in replacement LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel / MCCB in bldg etc to suit the cable laid in trenches/fixed to poles/drawn through pipes of sizes 400 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, testing and commissionnig in replacement LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 Part-I, including cable glands, crimpimg type cable lugs in LT panel / MCCB in bldg etc to suit the cable laid in trenches/fixed to poles/drawn through pipes complete of sizes 300 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, testing and commissionnig in replacement LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel / MCCB in bldg etc to suit the cable laid in trenches/fixed to poles/drawn through pipes complete of sizes 240 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, testing and commissionnig in replacement LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel / MCCB in bldg etc to suit the cable laid in trenches/fixed to poles/drawn through pipes complete of sizes 185 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, testing and commissionnig in replacement LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel / MCCB in bldg etc to suit the cable laid in trenches/fixed to poles/drawn through pipes complete of sizes 120 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, testing and commissionnig in replacement LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel / MCCB in bldg etc to suit the cable laid in trenches/fixed to poles/drawn through pipes complete of sizes 50 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, testing and commissionnig in replacement LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel / MCCB in bldg etc to suit the cable laid in trenches/fixed to poles/drawn through pipes complete of sizes 16 Sqmm 4 core complete all as specified and directed.
Supply and laying 80mm bore light grade GI pipe fixed to walls / poles or laid in trenches, road crossing etc, for protection of under ground cable including sealing ends with hessian cloth impregnated with bituminous compound in ground and with suitable clamps, bolt/nuts etc for fixing on walls, poles etc including taking out old unserviceable GI pipe complete all as specified and directed.
Supply and laying 50mm bore light grade GI pipe fixed to walls / poles or laid in trenches, road crossing etc, for protection of under ground cable including sealing ends with hessian cloth impregnated with bituminous compound in ground and with suitable clamps, bolt/nuts etc for fixing on walls, poles etc including taking out old unserviceable GI pipe complete all as specified and directed.
Supplying and laying in replacement synthetic rubber insulated mats 3 mm thick for voltage upto 33 KV (size 2 m x 1 mtr) for electrical purpose as per IS 15652-2006 suitable for electrical shock safety complete all as specified and directed.
Supply, fixing, installation, testing and comissioning of free standing floor mounted, dust and vermin proof Panel of suitable size for out door installation factory made both front and rear side double door system, fabricated with 3.15 mm thick CRCA sheet for load bearing members and 2 mm thick for doors and covers and shall be painted witrh epoxy powder paint by means of electro static gun after rigorous pre treatment comprising of cold phosphating process on all internal and external surfaces after due preparation of surfaces. The panel shall consist of 600 ,Amps rating TPN bus bars of high conductivity aluminium alloy and shall be provided with colour coded heat shrinkaable sleeves,with 600 mm depth of the panel. The panel shall be modular/cubical trype with bus chamber cable allyand provided with separate fully compartments for each switch including instrumentation such as Ampere Meter, Volt meter, Phase indicating lamp with double stud hinged door , front and rear openable with locking arrangement and suitable for 1100 Volts grade , 3 phase 415 Volts , 50 cycles , AC Supply and to with stand short circuit fault level of not less than 10 KA and degree of protection shall be IP 54 . The panel shall be fixed with angle iron frame made of angles of size 50x50x6 mm , embedded 200 mm below ground level in PCC 1:2:4, Type B1 using 20 mm grade stone aggregate , 600 mm above ground level and comprising the following including taking out of old panels etc , removing of cables and connecting to new panels with all required material such as glands, lugs etc Note :- The design of LT panel shall be got approved by GE.
INCOMING :- (a) MCCB 4 pole 400 Amps capacity rup cap 36 KA at 415 volt 50 Hz AC fixed thermal magnetic release type and earth leakage protection ICS =100% ICU with rotary handle - 01 No incoming OUTGOING :- (a) MCCB 4 pole 250 Amps capacity rup cap 25 KA at 415 volt 50 Hz AC fixed thermal magnetic release typewith rotary handle - 01 Nos Out going (b) MCCB 4 pole125 Amps capacity rup cap 16 KA at 415 volt 50 Hz AC fixed thermal magnetic release type with rotary handle - 02 Nos Out going (c) MCCB 3 pole 63 Amps capacity rup cap 16 KA at 415 volt 50 Hz AC fixed thermal magnetic release type with rotary handle - 02 Nos Out going (d) LT Danger notice plate -01 No (e) Panel Control wiring complete with suitable size copper conductor cable and suitable size gland for LT cables
Repair to 250 KVA Compact Sub Station includes HT sides, LT sides and connected switchgears / spares required complete will be carried out by OEM only including replacement of unserviceable parts by new spares as per part list of OEM complete as specified and directed. Note : - 1. Spares required for above maintenance / repair deemed to be included in this item only and Servicing to be carried out as per manufacturer instruction.
Dehydration and Filteration of 11 KV grade Transformer oil through stream line filteration plant for extracting moisture content in the oil and carbon deposits and achieving the dielectric strength upto 40 KV for 1 minute with a spare gap of 2.5 mm and also checking the acidity of oil with acidity test kit and submitting the necessary test kit report /certificate, refilling the filtered oil into any KVA transformer etc complete all as specified and directed. Note:- The filtration includes taking necessary connection to filtration plant from the transformer to their hose pipe by opening the inlet and outlet of transformers and closing the same after filtration.
Taking out HT VCB/OCB ,11 KV grade 400 Amps rating from HT panel for servicing / repairs by dismantling the HT VCB operating mechanism, inspection of control wiring realignment of moving contacts with fixed contacts assembly, vaccum interrupter ,checking of relays for protection, greasing of all moving parts of mechanics, checking and realignment of mechanism for its proper functioning and operation, re-assembling of HT VCB , fixed in its original position , testing for functions, and commissioning complete all as specified and directed
S&F of push button suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in repair HT bushing spout of fibre or as per existing for 11 KV HT VCB 400 Amp rating and removing the unserviceable spout complete all as specified and directed
Calibration of 11 KV grade HT VCB /OCB relays of various types / Make by OEM through primary & Secondary injection method by bringing relay test kit, software PC system and other required measuring equipments to the site, after testing refixing to VCB/OCB 11 KV panel complete all as specified and directed Note:- Certificate of this test will be provided by the contractor.
Testing of HT current transformer (set of three) through primary current injection method and checking the connected panel wiring by brining required test kit and other required testing equipment and also checking tripping and closing operation complete all as specified and directed
Supply, installation, testing and commissioning in repair of 11 KV grade HT VCB/OCB current transformer CT of 11 KV grade with CT ratio 300/150/5-5 fixed with HT VCB 11 KV including necessary cable connection etc suitable for fixing in HT panel board of any make including modification required at site to be carried to fix CT upto recess/coils including removing the burnt CTs complete all as specified and directed
M&L for checking of Potential Transformer by conducting ratio test/meggering for IR values, provided in VCBs/OCBs 11 KV feeders checking of control wiring meters, relay and tripping system complete all as specified and directed
S&F in repair Potential Transformer for HT OCB/VCB 11/110 volts/3, 100 VA resin cast epoxy moulded with metal enclosure as per site requirement and connecting bus bar including providing bus bar, testing for functionality complete all as specified and directed
S&F in repair HT Voltmeter, range 0 to 15 KV auxillary supply 110 Volts suitable for fixing with existing HT VCB 11 KV panel complete all as specified and directed
S&F in repair ammeter suitable for fixing with existing HT VCB / OCB 11 KV panel ratio like 300/5,200/5,100/5 complete all as specified and directed
Supply only hand gloves HT for operating / handling sub station 22 to 33 KV ISI Marked complete all as specified and directed
S&F breather assembly suitable for existing transformer upto 500 KVA capacity including taking out old unserviceable assembly complete all as specified and directed
Repair to transformer to arrest oil leakage by removing transformer oil , dismantling the top cover alongwith conservator tank/ OLTC, replacing the top gasket washer etc replacement of HT/LT bushes including dismantling the cooling fins and welding where leakage to arrest oil leakage and reassembling the transformer, refilling filtered oil testing complete for transformer capacity upto 500 KVA complete all as specified and directed Note:- Filteration of oil and all other spare/Material will be measured and paid separately as supply only.
Repair to the exsisting Transformer upto 500 KVA transformer by disconnecting incoming and outgoing HT/LT cables/bus duct connection, shifting to workshop by arranging suitable vehicle and crane and removing tank top cover /lid of 11 KV grade at workshop , draining out the transformer oil and keeping in safe custody in clean and dry containers for reuse and carrying out the maintenance work by experienced and qualified Engineer , dismantling the OLTC/ conservator tank , dismantling HT/LT bushings from core winding and lifting the core assembly carefully without damaging by using the tripod/ chainpully/crane etc, cleaning / removing the sludge from the transformer tank, cleaning the OLTC/ conservator tank and checking the serviceability of the coil / core winding , checking the condition of the body , cleaning the coil/ core assembly, refixing of core , core assembly, OLTC/ conservator tank, HT/LT winding connection, connection of protective devices like buckholz relay connection,winding temperature indication ,oil temperature indication including fixing new gaskets to transformer top and all other places gaskets/washer , terminal studs of HT/LT sides and reassembling of transformer after repairs, refitting the transformer coil incl improvement of insulation resistance value within desired level by heating or any other method to required level and re assembling at the site, connection of LT/HT sides, testing and charging the transformer complete all as specified and directed Note:- Filteration of oil and all other spare parts/unserviceable material will be measured and paid separately .
Supply only silica gel in the transformer breather assembly complete all as specified and directed
Supply only HV Bushing suitable for upto 500 KVA transformer including connection complete all as specified and directed
Supply only LV Bushing suitable for upto 500 KVA transformer including connection complete all as specified and directed
Supply only copper terminal stud , both end threaded complete with double nuts and washers with heat resistant gasket suitable for upto 500 KVA transformer LV side 415 volts including connection complete all as specified and directed
Supply and flling transformer oil duly filtered and tested confirming to IS 335 1963 as amended including testing complete all as specified and directed
Supply only (HV side) copper winding coil of existing type size and guage 11000 volts complete with insulating material for transformers of upto 500 KVA complete all as directed.
All as per item Ser No 59.00 above but LT side, 415 volts.
S&F in repair of limit switch suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in repair AC/DC controling unit suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in repair tripping and closing coil 24 v DC suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in repair bushing suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in repair bushing rod suitable for 400 amps VCB/OCB complete all as specified and directed.
Supply and fixing of CT with ratio 100/50/5+1 suitable for 400 amps VCB/OCB complete all as specified and directed.
Supply and fixing of 11KV OCB spout contact suitable for 400 amps VCB/OCB complete all as specified and directed.
Supply and fixing of panel wiring complete suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in repair earth fault over current relay IDMT relay suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in repair 5 way RMU CT 400/200/1-1 complete suitable for RMU complete all as specified and directed.
Taking proper shutdown & Isolate the HT electric supply and HT 11KV outdoor upto 5 way RMU of any make and type and servicing of all minor/major parts of the RMU by cleaning isolating contact moving parts,removing dust particle from the bus bar chamber spout gear mechanism, repair to motor charge spring mechanism,tightening of all nut & bolts and testing the complete HT electric supply and putting on supply on load complete all as directed.
S&F in replacement HRC/MCB fuse link clip type on fuse link 2 to 20 amps operating voltage 415 Volt complete all as specified and directed.
S&F in replacement fuse base suitable for cylindrical/DIN type HRC fuse of capacity 2-32 Amps complete all specified and directed.
S&F in replacement of closing spring assembly complete all as specified and directed.
S&F in replacement of tripping spring assembly complete all as specified and directed.
S&F in replacement of charging motor cut off limit switch complete all as specified and directed.
S&F in replacement of spring charging handle motorized mechanism of VCB complete all as specified and directed.
S&F in replacement of push button bracket assembly complete all as specified and directed.
S&F in replacement of bus bar support insulator 75 mm dia including all fixing accessories complete suitable for VCB/HT bus bar chamber complete all as specified and directed.
S&F in replacement of bus bar barrier as per existing (set of three) with nuts bolts complete all as specified and directed.
S&F in replacement of toggle switch for space heater with all accessories complete all as specified and directed.
S&F in replacement of charged/ discharged indication assembly complete all as specified and directed.
S&F in replacement of 11 pin anti pumping relay 110 volt DC complete all as specified and directed.
S&F in replacement of bottom terminal with jaw contact complete all as specified and directed.
S&F in replacement of top terminal with jaw contact complete all as specified and directed.
S&F in replacement of PT epoxy female bushing suitale for R Y B phase complete all as specified and directed.
S&F in replacement of PT epoxy male bushing suitale for R Y B phase complete all as specified and directed.
S&F in replacement of PT fuse 11 KV complete all as specified and directed.
S&F in repair HT bushing 11 KV suitable for upto 500 KVA transformer including brass rod complete with gasket as per matching to existing all as specified and directed.
S&F in repair LT bushing 11 KV suitable for upto 500 KVA transformer including brass rod complete with gasket as per matching to existing all as specified and directed.
S&F in repair head gasket sheet 6 mm thick suitable for transformer upto 500 KVA capacity including replacement of nuts bolts washers including necessary T&P required at site complete all as specified and directed.
S&F in repair temparature gauge analog type complete with all accessories as per matching to existing complete all as specified and directed.
S&F in repair three phase over current earth fault relay MC-61 as per matching to existing including all accessories and wiring complete all as specified and directed.
S&F in repair three phase over current earth fault relay MC-61A as per matching to existing including all accessories and wiring complete all as specified and directed.
S&F in repair LED type indication lamp of voltage AC/DC set of RYB as per matching to existing complete all as specified and directed.
S&F in repair battery charger of capacity 12 volts for AMF panel complete all as specified and directed.
S&F in repair battery charger of capacity 24 volts for AMF panel complete all as specified and directed.
S&F in repair HT three phase digital multifunctional meter suitable for measure all electricl qualities like voltmeter, current, power, Frequency & power factor complete all as specified and directed.
S&F in repair LT three phase digital multifunctional meter suitable for measure all electricl qualities like voltmeter, current, power, Frequency & power factor complete all as specified and directed.
S&F in repair VCB power pack unit 24 volt DC 7 AH with battery bank for backup for panel as per existing matching complete all as specified and directed.
S&F in replacement of RMU protection relay model No- CSDPR-V2 type CSDR-V2-300-D-L-P, Frequence-50Hz, UN-in-1A, UV-18-60 volt DC and control rating-5A @ 220 volt AC and making as per existing make (C&S) with all connected accessories complete all as specified and directed.
M&L for painting of LT panel indoor/outdoor type all over area of front face of panel exc 1.5 sqm but n. exc 2.5 sqm each with spray gun with two coats of synthetic enamel heat resistant grey paint including preparation of old painted surface/ removing old faded/rust/cemeted material of surface of complete LT panel , complete all as specified and directed.
S&F in repair angle iron work and fixing/fabrication of angle iron frame 40x40x5/50x50x6 mm thick as required at site for LT panel complete including welding work at site complete all as specified and directed.
S&F in repair LT panel body of any size/make incl cutting, welding of front panel back cover and top cover made of CRCA steel sheet of size not less than 2/3.15 mm thick as per site requirement including colour matching with existing including hinges and locking device complete all as specified and directed.
S&F in repair of aluminium bus bar PVC insulated in red,yellow, blue & black colours of rating 400 amps complete all as specified and directed.
S&F in repair of aluminium bus bar PVC insulated in red,yellow, blue & black colours of rating 800 amps complete all as specified and directed.
S&F in repair of aluminium bus bar PVC insulated in red,yellow, blue & black colours of rating 1500 amps complete all as specified and directed.
S&F in repair of APFC relay for upto 225 KVAR 10 stages including wiring CTs and all connected item complete all as specified and directed.
S&F in repair of LED type indicating lamp type of voltage AC/DC set of RYB as per matching to existing complete all as specified and directed.
S&F in repair of capacitor bank MP-05 KVAR capacity rated 440 volts AC, 3 phase, 50 Hz delta connection round type complete all as specified and directed.
S&F in repair of capacitor bank MP-10 KVAR capacity rated 440 volts AC, 3 phase, 50 Hz delta connection round type complete all as specified and directed.
S&F in repair of capacitor, contractor MO C5 to C25 complete all as specified and directed.
S&F in repair ON load change over switch 440 volts 4 pole of rating 400 amps with encloser fixed on wall/ panel including nut/bolts/washers complete all as specified and directed.
Servicing /Caliberation / Repairs to Air Circuit Breaker 800 to 1600 Amps by OEM of ACB only for EDO ( Electrically Draw Out) type/ MDO type(Mannually Draw out type)/ Fixed type. Taking out any type of ACB for servicing / repair and checking / caliberation of microprocessor release,Earth fault protection of 4 pole, 50 KA breaking capacity 415 volts with all draw out type mechanism, advanced self powered electronic protection units, neutral overload protection, automatic earth fault relay / over current relay , automatic safety shutter, inbuilt temperature protection, icu=ics=icw(1s)=50 KA fixed in panel complete including relay wiring checking, LT UG cable connection with main incoming ACB complete connection for its healthy functioning complete all as specified and directed. Note:- Certificate of Servicing /Caliberation will be provided by the contractor.
S&F in repair protection releases for air circuit breakers microprocessor based type suitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and directed (Make- L&T-8538 or equivalent in Legrand/ABB/Schenider).
S&F in repair earth fault realease for air circuit breakers microprocessor based type suitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and directed (Make- L&T-8538 or equivalent in Legrand/ABB/Schenider).
S&F in repair shunt realease for air circuit breakers microprocessor based type suitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and directed (Make- L&T-8538 or equivalent in Legrand/ABB/Schenider).
S&F in repair under voltage realease for air circuit breakers microprocessor based type suitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and directed (Make- L&T-8538 or equivalent in Legrand/ABB/Schenider).
S&F in repair lockable trip push button for air circuit breakers microprocessor based type suitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and directed (Make- L&T-8301 or equivalent in Legrand/ABB/Schenider).
M&L for bringing Cable testing van (Fault Finder) for detecting the location of fault in the LT UG cable 1.1 KV and HT UG cable 11 KV grade of any size complete all as specified and directed
M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 120 to 400 Sqmm 3.5 core including all accessories required complete all as specified and directed.
Taking down of Old unserviceable point wiring any type for light, fan, power etc including unserviceable switch,socket, regulator and ceiling rose etc of any make complete including making good disturbed surfaces of walls, floors roof etc complete all as specified and directed.
M&L for Point wiring with 1.5 Sqmm multistranded copper conductor cable multistranded, FRLSH PVC insulated and unsheathed in PVC concealed conduit including cutting chasing for conduits and terminal boxes with all fittings /accessories and including FRLSH 1.5 Sqmm PVC insulated copper earth wire connected common earth with terminal boxes 2mm thick GI sheet for Modular fittings including acessories as modular surface cover plate with frame, for one light/Fan/Exhaust Fan/bell point complete all as specified and as directed.
All as per srl item No 123.00 above but for 1 No. 05 Amps Socket outlet point on independent board.
All as per srl item No 123.00 above but using cable size 2.5 Sqmm for 15 Amps Socket outlet, terminal boxes for Modular switches with 2.5 sqmm earth wire.
M&L for Point wiring with 1.5 Sqmm multistranded copper conductor cable , FRLSH PVC insulated and unsheathed in PVC casing & caping double lock including fixtures and terminal boxes with all fittings /accessories and including FRLSH 1.5 Sqmm PVC insulated copper earth wire connected common earth with terminal boxes 2mm thick GI sheet for Modular fittings including acessories as modular surface cover plate with frame, for one light/Fan/Exhaust Fan/bell point complete all as specified and as directed.
All as per ser item No. 126.00 above but for 05 Amps Socket outlet point on independent board, complete all as specified and directed.
All as per ser item No. 126.00 above but using cable size 2.5 Sqmm for 15 Amps Socket outlet, complete all as specified and directed.
M&L for Point wiring with 1.5 Sqmm multistranded copper conductor cable , FRLSH PVC insulated and unsheathed in existing PVC conduit including fixtures and terminal boxes with all fittings /accessories and including FRLSH 1.5 Sqmm PVC insulated copper earth wire connected common earth with terminal boxes 2mm thick GI sheet for Modular fittings including accessories as modular surface cover plate with frame, for one light/Fan/Exhaust Fan/bell point including taking out old unserviceable point wiring except conduit complete all as specified and as directed.
All as per ser item No. 129.00 above but using cable size 1.5 Sqmm for 05 Amps Socket outlet point on independent board, complete all as specified and directed.
All as per ser item No. 129.00 but using cable size 2.5 Sqmm for 15 Amps Socket outlet with 2.5 sqmm earth wire, complete all as specified and directed.
S&F in repair of Plug Top 05 Amps, complete all as specified and directed.
S&F in repair of Plug Top 16 Amps, complete all as specified and directed.
S&F modular switch 6 Amp single module one way, complete all as specified and directed.
S&F modular switch 16 Amp double module one way complete all as specified and directed
S&F modular socket 5 Pin outlet shuttered of 6A 2 Module, complete all as specified and directed.
S&F modular socket 5 Pin outlet shuttered of 6Amp/16Amp 2 Module, complete all as specified and directed.
S&F Fan step regulator 1 module, complete all as specified and directed.
S&F in repair capacitor 2.5 mfd including connection complete all as specified and directed.
S&F in repair capacitor 3.15 mfd including connection complete all as specified and directed.
M&L in replacement sub main wiring 2x4 sqmm and 1x4 Sqmm earth wire PVC insulated FRLSH multistranded copper conductor ISI marked 1100 V grade cable PVC in existing concealed conduit or fixed in wall/floor, passing through wall/ceiling complete.
M&L in replacement sub main wiring 2x6 sqmm and 1x6 Sqmm earth wire PVC insulated FRLSH multistranded copper conductor ISI marked 1100 V grade cable in existing PVC concealed conduit or fixed in wall/floor, passing through wall/ceiling, complete all as specified and directed. Note for ser item No. 141 & 142 :- Two run of main wire and one run of earth wire shall be measured as one unit.
S&F in repair MCB single pole & Neutral 32 Amps, complete all as specified and directed.
S&F in repair MCB single pole & Neutral 20 Amps, complete all as specified and directed.
S&F in repair MCB single pole 6-32 Amps 240 Volt, complete all as specified and directed.
S&F ceiling rose 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed.
S&F in repair PVC Sheathed copper conductor cable 2.5 Sqmm 3 core, complete all as specified & directed.
S&F in repair of heating element 1.5KW for 25Ltr ISI marked hot water heater complete including connection, complete all as specified and directed.
S&F in repair of heating element 2.00KW for 50Ltr ISI marked hot water heater complete including connection, complete all as specified and directed.
S&F in repair of inlet/outlet assembly to matching the existing 25/50 Ltr capacity geyser inclding fixing and testing complete all as specified and directed.
S&F in repair of stainless steel water tank suitable for 25 Ltr geyser complete including proper fixing and testing after repair complete all as specified and directed.
S&F in repair of stainless steel water tank suitable for 50 Ltr geyser complete including proper fixing and testing after repair complete all as specified and directed.
S&F in repalcement of thermostat switch for 25/50 Ltr geyser including LED indicator lamp complete all as specified and directed.
S&F in repair of switch piano type flush type single pole one way 5 Amps, complete all as specified and directed.
S&F in replacement of socket outlet 2 in 1, 3 Pin 5 Amps, complete all as specified and directed.
S&F in repair of switch piano type flush type single pole one way 15 Amps, complete all as specified and directed.
S&F in repair of socket outlet 2 in 1, 3 Pin 5 & 15 Amps, complete all as specified and directed.
S&F in repair of PVC connection 600mm long with brass Nut with rubber washer suitable hot/cold water, complete all as specified and directed.
M&L for rewinding of Exhaust fan with super enamelled copper winding wire of suitable gauge, varnishing material including cleaning and removing all dust etc, fixing, connecting with 3 core 1.5 Sqmm copper conductor flexible cable complete and testing after repair complete.
S&F in repair of Ceiling fan 1200mm sweep copper wound of BLDC type BEE 5.00 star rated in white colour and connection with 1.5 sqmm 3 core copper conductor cable complete all as specified and directed. Note: Old unserviceable Ceiling fan shall be deposited to MES store.
S&F in repair of Ceiling fan 1400 mm sweep copper wound of BLDC type BEE 5.00 star rated in white colour and connection with 1.5 sqmm 3 core copper conductor cable complete all as specified and directed. Note: Old unserviceable Ceiling fan shall be deposited to MES store.
S&F in replacement geyser 25 litres capacity, BEE 5 star rating and 8 bar pressure rated, with ferroglass coated inner container energy saving, high density PUF insulation vertical, adjustable knob for setting the temperature, shock safe plug to prevent electric shocks, including grouting of four Nos hold fasteners and 02 Nos PVC connection 600 mm long complete all as specified and directed. Note : Old unserviceable geyser shall be deposited to MES store.
S&F in replacement geyser 50 litres capacity, BEE 5 star rating and 8 bar pressure rated, with ferroglass coated inner container energy saving, high density PUF insulation vertical, adjustable knob for setting the temperature, shock safe plug to prevent electric shocks, including grouting of four Nos hold fasteners and 02 Nos PVC connection 600 mm long complete all as specified and directed. Note : Old unserviceable geyser shall be deposited to MES store.
S&F in repair of Pedestal Fan fan PVC body 400 mm dia having 03 Blade complete all as specified and directed. Note : Old unserviceable Pedestal fan shall be deposited to MES store.
S&F in repair of exhaust fan steel iron body 450 mm dia having 05 Blade including connection and fixing on wall with nuts bolts washers etc, complete all as specified and directed. Note : Old unserviceable exhaust fan shall be deposited to MES store.
S&F in repair of exhaust fan steel iron body 300 mm dia having 05 Blade including connection and fixing on wall with nuts bolts washers etc, complete all as specified and directed. Note : Old unserviceable exhaust fan shall be deposited to MES store.
S&F in repair of exhaust fan PVC body 250 mm dia having 05 Blade including connection and fixing on wall with nuts bolts washers etc, complete all as specified and directed. Note : Old unserviceable exhaust fan shall be deposited to MES store.
S&F in repair of exhaust fan PVC body 200 mm dia having 05 Blade including connection and fixing on wall with nuts bolts washers etc, complete all as specified and directed. Note : Old unserviceable exhaust fan shall be deposited to MES store.
S&F in repair of wall mounting fan 400 mm dia including connection and fixing on wall with nuts bolts washers etc, complete all as specified and directed. Note : Old unserviceable wall mounting fan shall be deposited to MES store.
Taking down Ceiling Fan and deposit in safe custudy and refixing the same after Painting with synthetic enamel white paint by spraying machine and provide MES No using synthetic enamel paint in black tint, greasing, oiling,minor repairing on the completion of the work complete all as specified and as directed.
Taking down old unserviceable ceiling fan and rewinding with super enamelled copper winding wire of existing gauge including varnish material and replacement of capacitor 2.5 mfd and painting of ceiling fan including fan blade and fixing the same in exising position and connecting with 1.5 Sqmm 3 core copper conductor cable complete all as specified and directed.
S&F in repair of capacitor 4 mfd including connection complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F Fan step regulator 2 module complete all as specified and directed.
Pradeep Bros
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .