Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 CrAccepted-AOC 8 ELECTRONICS COMPLEX CHAMBAGHAT SOLAN HIMACHAL PRADESH 173213 | SOLAN | HIMACHAL PRADESH | 173213 | ₹9.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹11.3 Cr+₹2.2 Cr (23.8%)Rejected-Finance | ₹11.3 Cr+₹2.2 Cr (23.8%) | L2 | Rejected-Finance L2 |
Tender Value
Refer Docs
EMD Value
₹9.9 L
Closing Date
8 Aug 2019, 2:30 pmClosed
DGM PJ CONTARCTS
Indian Oil Corporation Limited Pipelines Division A 1, Udyog Marg, Sector 1, NOIDA UP 201 301
Design, Supply, Installation and Commissioning of DC power system comprising Battery Charger, Solar System, Battery bank and Electronic Power Fence for Solar System
2019_PLHO_98936_1
PLCC/ETBPNMTPL/TI/19050
Open Tender
Instrumentation - All
Works
365 days
ETBPNMTPL
As per tender terms and condition
5 documents required · 5 mandatory
₹9.9 L
Yes
PLHO, NOIDA
3 Dec 2020
11 Jun 2019
9 Aug 2019
11 Jun 2019
8 Aug 2019
2 Jul 2019
19 Jun 2019
Amount
Part A-DC Power System_1 Tamil Nadu
A Supply
Battery Charger, 230V AC/ 48V DC, 125 A + 25 A (SMPS based) in n+1 configuration i.e. 5+1 = 6 nos, 25A modules as per specifications. The system includes Surge & Lightning Protection at 230 V AC input & -48 V DC output as per specifications.(At RCP & unattended IP)
Battery Charger, 230V AC/ 48V DC, 75 A + 25 A (SMPS based) in n+1 configuration i.e. 3+1 = 4 nos, 25A modules as per specifications. The system includes Surge & Lightning Protection at 230 V AC input & -48 V DC output as per specifications.(AT Attended /RWS locations & SV )
"Set of spares for Battery Charger as per specifications comprising - i) SMR Module (4 Sets) ii) Monitoring, Controller Module (2 Sets) iii) Display Module (2 Sets) iv) Any other OEM specific Electronic Card (2 Sets) v) All types of Contactors & Fuses (4 Sets) (At Ennore & Palliyagram)"
Resistive DC load ( 48V/100A) as per tender specifications (At Attended /RWS locations)
Portable gravity fed emergency eye washer system as per tender specifications (At RCP, unattended IP & SV locations)
Tubular Lead Acid OPzS type Battery 48V DC, 800 AH along with battery stand & accessories, as per specifications(At RCP & unattended IP)
Tubular Lead Acid OPzS type Battery 48V DC, 400 AH along with battery stand & accessories, as per specifications.(At attended/RWS lcoations)
Tubular Lead Acid OPzS type Battery 48V DC, 500 AH along with battery stand & accessories, as per specifications(At SV)
Electronic Perimeter Security System (Power Fencing) for Solar Panels at RCP/ CP+MOV/MOV locations as per tender specifications(At RCP, unattended IP & SV locations)
Installation Materials for DC power system, charger,battrey bank, solar panel, elelctric power fencing , AC/ DC Distribution Boxes (ACDBs/ DCDBs), MCBs/ Isolator Switches, Power Distribution Boards, power cables for input power supply to Battery Charger, required cables for taking power supply from Owner's ACDB/distribution / Battery Charger to equipments, required cable from Solar panel to Array junction box to battery charger, all required Installation Material including PVC/GI conduits, casing pipes, clamps, screws etc. as per specifications(At all attended & unattended locations)
B Services
Erection, Installation, Testing and Commissioning including local testing of the complete DC power system including solar panel, power fencing DCDB, cabling etc at Independent SV/ MOV Stations, CP+SV/ RCP station as per scope and specifications of tender
Erection, Installation, Testing and Commissioning including local testing of the complete DC power system including DCDB, cabling etc attended Stations as per scope and specifications of tender
Part A-DC Power System- 2 Tamil Nadu
A Supply
Solar System for RCP Locations (Capacity 6 KWp) as per specifications(At RCP & unattended IP)
Solar System for Independent SV Locations (Capacity 3 KWp) as per specifications(At SV locations)
"Set of spares for Solar Charge Controller as per specifications comprising - i) Solar Charge Controller Module (4 Sets) ii) Any other OEM specific Electronic Card (2 Sets) (At Ennore & Palliyagram)"
Part A-DC Power System_1 Andhra Pradesh
A Supply
Battery Charger, 230V AC/ 48V DC, 125 A + 25 A (SMPS based) in n+1 configuration i.e. 5+1 = 6 nos, 25A modules as per specifications. The system includes Surge & Lightning Protection at 230 V AC input & -48 V DC output as per specifications.(At RCP)
Battery Charger, 230V AC/ 48V DC, 75 A + 25 A (SMPS based) in n+1 configuration i.e. 3+1 = 4 nos, 25A modules as per specifications. The system includes Surge & Lightning Protection at 230 V AC input & -48 V DC output as per specifications.(At RWS & SV locations)
"Set of spares for Battery Charger as per specifications comprising - i) SMR Module (4 Sets) ii) Monitoring, Controller Module (2 Sets) iii) Display Module (2 Sets) iv) Any other OEM specific Electronic Card (2 Sets) v) All types of Contactors & Fuses (4 Sets) (At RWS location)"
Resistive DC load ( 48V/100A) as per tender specifications (At RWS location)
portable gravity fed emergency eye washer system as per tender specifications (At RCP & SV locations)
Tubular Lead Acid OPzS type Battery 48V DC, 800 AH along with battery stand & accessories, as per specifications(At RCP)
Tubular Lead Acid OPzS type Battery 48V DC, 400 AH along with battery stand & accessories, as per specifications.(At RWS)
Tubular Lead Acid OPzS type Battery 48V DC, 500 AH along with battery stand & accessories, as per specifications(At SV)
Electronic Perimeter Security System (Power Fencing) for Solar Panels at RCP/ CP+MOV/MOV locations as per tender specifications(At RCP & SV locations)
Installation Materials for DC power system, charger,battrey bank, solar panel, elelctric power fencing , AC/ DC Distribution Boxes (ACDBs/ DCDBs), MCBs/ Isolator Switches, Power Distribution Boards, power cables for input power supply to Battery Charger, required cables for taking power supply from Owner's ACDB/distribution / Battery Charger to equipments, required cable from Solar panel to Array junction box to battery charger, all required Installation Material including PVC/GI conduits, casing pipes, clamps, screws etc. as per specifications(At all attended & unattended locations)
B Services
Erection, Installation, Testing and Commissioning including local testing of the complete DC power system including solar panel, power fencing DCDB, cabling etc at Independent SV/ MOV Stations, CP+SV/ RCP station as per scope and specifications of tender
Erection, Installation, Testing and Commissioning including local testing of the complete DC power system including DCDB, cabling etc attended Stations as per scope and specifications of tender
Part A-DC Power System-_2 Andhra Pradesh
A Supply
Solar System for RCP Locations (Capacity 6 KWp) as per specifications(At RCP)
Solar System for Independent SV Locations (Capacity 3 KWp) as per specifications(At SV)
"Set of spares for Solar Charge Controller as per specifications comprising - i) Solar Charge Controller Module (4 Sets) ii) Any other OEM specific Electronic Card (2 Sets) (At RWS)"
Part A-DC Power System_1 Karnataka
A Supply
Battery Charger, 230V AC/ 48V DC, 125 A + 25 A (SMPS based) in n+1 configuration i.e. 5+1 = 6 nos, 25A modules as per specifications. The system includes Surge & Lightning Protection at 230 V AC input & -48 V DC output as per specifications.(At RCP)
Battery Charger, 230V AC/ 48V DC, 75 A + 25 A (SMPS based) in n+1 configuration i.e. 3+1 = 4 nos, 25A modules as per specifications. The system includes Surge & Lightning Protection at 230 V AC input & -48 V DC output as per specifications.(At Bengaluru & SV)
"Set of spares for Battery Charger as per specifications comprising - i) SMR Module (4 Sets) ii) Monitoring, Controller Module (2 Sets) iii) Display Module (2 Sets) iv) Any other OEM specific Electronic Card (2 Sets) v) All types of Contactors & Fuses (4 Sets) (At Bengaluru)"
Resistive DC load ( 48V/100A) as per tender specifications ( At Bengaluru)
portable gravity fed emergency eye washer system as per tender specifications (At RCP & SV)
Tubular Lead Acid OPzS type Battery 48V DC, 800 AH along with battery stand & accessories, as per specifications(At RCP)
Tubular Lead Acid OPzS type Battery 48V DC, 400 AH along with battery stand & accessories, as per specifications.(At Bengaluru)
Tubular Lead Acid OPzS type Battery 48V DC, 500 AH along with battery stand & accessories, as per specifications(At SV)
Electronic Perimeter Security System (Power Fencing) for Solar Panels at RCP/ CP+MOV/MOV locations as per tender specifications(At RCP & SV)
Installation Materials for DC power system, charger,battrey bank, solar panel, elelctric power fencing , AC/ DC Distribution Boxes (ACDBs/ DCDBs), MCBs/ Isolator Switches, Power Distribution Boards, power cables for input power supply to Battery Charger, required cables for taking power supply from Owner's ACDB/distribution / Battery Charger to equipments, required cable from Solar panel to Array junction box to battery charger, all required Installation Material including PVC/GI conduits, casing pipes, clamps, screws etc. as per specifications(At all attended & unattended locations)
B Services
Erection, Installation, Testing and Commissioning including local testing of the complete DC power system including solar panel, power fencing DCDB, cabling etc at Independent SV/ MOV Stations, CP+SV/ RCP station as per scope and specifications of tender
Erection, Installation, Testing and Commissioning including local testing of the complete DC power system including DCDB, cabling etc attended Stations as per scope and specifications of tender
Part A-DC Power System_2-Karnataka
A Supply
Solar System for RCP Locations (Capacity 6 KWp) as per specifications(At RCP)
Solar System for Independent SV Locations (Capacity 3 KWp) as per specifications(At SV)
"Set of spares for Solar Charge Controller as per specifications comprising - i) Solar Charge Controller Module (4 Sets) ii) Any other OEM specific Electronic Card (2 Sets) (At Bengaluru)"
Part A-DC Power System_1_Puducherry
A Supply
Battery Charger, 230V AC/ 48V DC, 125 A + 25 A (SMPS based) in n+1 configuration i.e. 5+1 = 6 nos, 25A modules as per specifications. The system includes Surge & Lightning Protection at 230 V AC input & -48 V DC output as per specifications.(At RCP)
portable gravity fed emergency eye washer system as per tender specifications (At RCP)
Tubular Lead Acid OPzS type Battery 48V DC, 800 AH along with battery stand & accessories, as per specifications(At RCP)
Electronic Perimeter Security System (Power Fencing) for Solar Panels at RCP/ CP+MOV/MOV locations as per tender specifications(At RCP)
Installation Materials for DC power system, charger,battrey bank, solar panel, elelctric power fencing , AC/ DC Distribution Boxes (ACDBs/ DCDBs), MCBs/ Isolator Switches, Power Distribution Boards, power cables for input power supply to Battery Charger, required cables for taking power supply from Owner's ACDB/distribution / Battery Charger to equipments, required cable from Solar panel to Array junction box to battery charger, all required Installation Material including PVC/GI conduits, casing pipes, clamps, screws etc. as per specifications(At RCP)
B Services
Erection, Installation, Testing and Commissioning including local testing of the complete DC power system including solar panel, power fencing DCDB, cabling etc at Independent SV/ MOV Stations, CP+SV/ RCP station as per scope and specifications of tender
Part A-DC Power System-2_Puducherry
A Supply
Solar System for RCP Locations (Capacity 6 KWp) as per specifications(At RCP)
Part A-AMC-Tamil Nadu
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 1st Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 2nd Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 3rd Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 4th Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 5th Year
Part A-AMC-Andhra Pradesh
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 1st Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 2nd Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 3rd Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 4th Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 5th Year
Part A-AMC-Karnataka
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 1st Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 2nd Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 3rd Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 4th Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 5th Year
Part A-AMC-Puducherry
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 1st Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 2nd Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 3rd Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 4th Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 5th Year
Part B-DC Power System_Tamil Nadu
A Supply
Battery Charger, 230V AC/ 48V DC, 125 A + 25 A (SMPS based) in n+1 configuration i.e. 5+1 = 6 nos, 25A modules as per specifications. The system includes Surge & Lightning Protection at 230 V AC input & -48 V DC output as per specifications.(RT-08 nos. & RT(future)-02 nos.)
Portable gravity fed emergency eye washer system as per tender specifications (RT-08 nos. & RT(future)-02 nos.)
Tubular Lead Acid OPzS type Battery 48V DC, 800 AH along with battery stand & accessories, as per specifications(RT-08 nos. & RT(future)-02 nos.)
Installation Materials for DC power system, charger,battrey bank, solar panel, elelctric power fencing , AC/ DC Distribution Boxes (ACDBs/ DCDBs), MCBs/ Isolator Switches, Power Distribution Boards, power cables for input power supply to Battery Charger, required cables for taking power supply from Owner's ACDB/distribution / Battery Charger to equipments, required cable from Solar panel to Array junction box to battery charger, all required Installation Material including PVC/GI conduits, casing pipes, clamps, screws etc. as per specifications(RT-08 nos. & RT(future)-02 nos.)
B Services
Erection, Installation, Testing and Commissioning including local testing of the complete DC power system including solar panel, power fencing DCDB, cabling etc at Customer location stations as per scope and specifications of tender (RT-08 nos. & RT(future)-02 nos.)
Part B-DC Power System_Andhra Pradesh
A Supply
Battery Charger, 230V AC/ 48V DC, 125 A + 25 A (SMPS based) in n+1 configuration i.e. 5+1 = 6 nos, 25A modules as per specifications. The system includes Surge & Lightning Protection at 230 V AC input & -48 V DC output as per specifications.(RT(future)-02 nos.)
Portable gravity fed emergency eye washer system as per tender specifications (RT(future)-02 nos.)
Tubular Lead Acid OPzS type Battery 48V DC, 800 AH along with battery stand & accessories, as per specifications(RT(future)-02 nos.)
Installation Materials for DC power system, charger,battrey bank, solar panel, elelctric power fencing , AC/ DC Distribution Boxes (ACDBs/ DCDBs), MCBs/ Isolator Switches, Power Distribution Boards, power cables for input power supply to Battery Charger, required cables for taking power supply from Owner's ACDB/distribution / Battery Charger to equipments, required cable from Solar panel to Array junction box to battery charger, all required Installation Material including PVC/GI conduits, casing pipes, clamps, screws etc. as per specifications(RT(future)-02 nos.)
B Services
Erection, Installation, Testing and Commissioning including local testing of the complete DC power system including solar panel, power fencing DCDB, cabling etc at Customer location stations as per scope and specifications of tender (RT(future)-02 nos.)
Part B-DC Power System_ Karnataka
A Supply
Battery Charger, 230V AC/ 48V DC, 125 A + 25 A (SMPS based) in n+1 configuration i.e. 5+1 = 6 nos, 25A modules as per specifications. The system includes Surge & Lightning Protection at 230 V AC input & -48 V DC output as per specifications.(RT(future)-02 nos.)
Portable gravity fed emergency eye washer system as per tender specifications (RT(future)-02 nos.)
Tubular Lead Acid OPzS type Battery 48V DC, 800 AH along with battery stand & accessories, as per specifications(RT(future)-02 nos.)
Installation Materials for DC power system, charger,battrey bank, solar panel, elelctric power fencing , AC/ DC Distribution Boxes (ACDBs/ DCDBs), MCBs/ Isolator Switches, Power Distribution Boards, power cables for input power supply to Battery Charger, required cables for taking power supply from Owner's ACDB/distribution / Battery Charger to equipments, required cable from Solar panel to Array junction box to battery charger, all required Installation Material including PVC/GI conduits, casing pipes, clamps, screws etc. as per specifications(RT(future)-02 nos.)
B Services
Erection, Installation, Testing and Commissioning including local testing of the complete DC power system including solar panel, power fencing DCDB, cabling etc at Customer location stations as per scope and specifications of tender (RT(future)-02 nos.)
Part B-DC power System_Puducherry
A Supply
Battery Charger, 230V AC/ 48V DC, 125 A + 25 A (SMPS based) in n+1 configuration i.e. 5+1 = 6 nos, 25A modules as per specifications. The system includes Surge & Lightning Protection at 230 V AC input & -48 V DC output as per specifications.(RT-03 nos. & RT(future)-02 nos.)
Portable gravity fed emergency eye washer system as per tender specifications (RT-03 nos. & RT(future)-02 nos.)
Tubular Lead Acid OPzS type Battery 48V DC, 800 AH along with battery stand & accessories, as per specifications(RT-03 nos. & RT(future)-02 nos.)
Installation Materials for DC power system, charger,battrey bank, solar panel, elelctric power fencing , AC/ DC Distribution Boxes (ACDBs/ DCDBs), MCBs/ Isolator Switches, Power Distribution Boards, power cables for input power supply to Battery Charger, required cables for taking power supply from Owner's ACDB/distribution / Battery Charger to equipments, required cable from Solar panel to Array junction box to battery charger, all required Installation Material including PVC/GI conduits, casing pipes, clamps, screws etc. as per specifications(RT-03 nos. & RT(future)-02 nos.)
B Services
Erection, Installation, Testing and Commissioning including local testing of the complete DC power system including solar panel, power fencing DCDB, cabling etc at Customer location stations as per scope and specifications of tender (RT-03 nos. & RT(future)-02 nos.)
Part B-AMC-Tamil Nadu
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 1st Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 2nd Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 3rd Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 4th Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 5th Year
Part B-AMC Andhra Pradesh
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 1st Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 2nd Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 3rd Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 4th Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 5th Year
Part B-AMC Karnataka
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 1st Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 2nd Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 3rd Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 4th Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 5th Year
Part B-AMC Puducherry
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 1st Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 2nd Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 3rd Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 4th Year
Comprehensive Annual Maintenance Contract for a period of 5 years (after completion of defect liability period) for the complete DC power sysetm, for specified SOR items as per tender requirement, specifications and scope of work for 5th Year
Eltek SGS Private Limited
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .