Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹32.0 L+₹97,358 (3.14%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹38 L
EMD Value
₹38,000
Closing Date
7 Apr 2025, 3:00 pmClosed
COMMISSIONER, KADAYANALLUR MUNICIPALITY
MUNICIPAL OFFICE, KADAYANALLUR
NNT 2023-24 Construction of Community Hall at Karuppanathi Dam Paliayar Kudiyiruppu (Kalaimannagar)
2025_MAWS_536591_1
25/2024/E1
Open Tender
Civil Works - Buildings
Works
120 days
KADAYANALLUR MUNICIPALITY
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹38,000
Yes
18 Jun 2025
29 Mar 2025
7 Apr 2025
29 Mar 2025
7 Apr 2025
29 Mar 2025
Amount
Earthwork excavating and depositing on bank with initial lead of 10 metres and lift of 2 metres in all kinds of soil except medium rock, dense medium rock and hard rock requiring blasting including refilling the sides of foundation with excavated earth in layers of 15 cm thick, watering and consolidation and depositing the surplus earth with in the compound in places as shown by the departmental officers with initial lead and lift, cleaning, leveling the site etc., complete complying with standard specifications
Supplying and filling in foundation and basement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.
Plain cement concrete 1:4:8 (One cement four sand and eight aggregate) using 40 mm ISS Hard Broken granite stone jelly for foundation and basement including watering if found necessary and laid in layers of 15 cm thick, and consolidated including curing, cost and conveyance of all metarials to work site, all labour and incidental charges etc., complete complying with standard specifications
Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9"X43/8"X 2 3/4" including curing, cost and conveyance of all metarials to work site, all labour and incidental charges etc., complete complying with standard specifications
Collection, Supply and filling with well morambu from approved quarry including cost and conveyance to site and stacking them at road sides to Departmental gauge for premeasuremnt including all labour charges for filling and all other incidental charges therefore etc complete of all materials and all labour charges etc,.,
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 (A)Slab and beam
For Plinth beam
Square column
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS staandards. (No separate payment will be made by the Department for the excess usage of materials)
Supplying, fabricating and placing in position of Steel Reinforcement using Mild steel or Ribbed tor steel rods, for all RCC works as per the design given by the departmental officers including cost of steel cutting, bending,placing in position and binding with binding wire and all labour charges for cutting, bending, tying and placing in position etc, complete as per SS
Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being '32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.
Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
Plastering with CM 1:3 mix, 10mm thick and including cost and conveyance of all materials to site and all labour charges and all other incidental charges etc., complete as per standard specification.
Plastering with CM 1:5 mix, 12mm thick and including cost and conveyance of all materials to site and all labour charges and all other incidental charges etc., complete as per standard specification.
Plain cement concrete 1:2:4 ( one cement, two sand, and four coarse aggregate ) M30 using 20 mm ISS hard broken granite stone jelly for all plain cement concrete works excluding cost of shuttering, and centering including all labour charges and incidental charges for cost and conveyance of all materials to work site, mixing and laying concrete, finishing the surface nearly rough, compacting using vibrators, curing etc., complete complying with standard specification
Paving the floor with Vitrified Marbonite tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3(one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
Dadooing walls with Glazed tiles of sizes 305mm X 200mm X 6mm size of approved make and quality and colour Set in cement mortar 1:2 (One part of Cement and two part of Plastering Sand (P- Sand)) over 10 mm base layer plastering and pointing with white cement neatly as directed.
Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification.
Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coat including the cost all materials etc.,complete, in all floors.
Supply and fixing of MS Grills for windows including cost of all materials and all labour charges for fixing in position including providing necessary locking arrangement and all other incidental charges there fore etc complete as per standard specifications
Providing & fixing PVC RAIN WATER DOWNFALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes,Bemds, other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of "U" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm]
Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (one cement and three sand ) 20mm thick laid in-situ and pointed with same coloured cement
Supplying and fixing in position Indian water closet of size 580 X 440mm, white glazed earthen ware of approved quality with 'P' trap or 'S' trap confirming to IS:2556 - Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers.
Supply and delivery and Fixing of Hdpe tank as per Is 12701/1996 including loading ,unloading transportation and labourcharges for fixing of the GI pipes connection works including cutting ,threading and fixing charges etc.,
Supplying and fixing in position best quality P.V.C soil/ waste pipes (6KSC) of various sizes having ISI mark and providing leakproof joints including fixing to the wall with P.V.C/ M.S clamps etc., and making connection to all sanitary fittings, dismandling masonry/R.C.C. works wherever necessary and making good the dismandled portion to the original condition, complying with standard specifications.110mm dia
Internal Water Supply - P.V.C. Pipes (6Kg/SqCm) Supplying laying and jointing P.V.C pipes (6Kg/SqCm) of approved quality and best variety conforming to I.S.S & with I.S.I mark, of the following sizes including cutting , Fixing to PVC specials using Adhesive but excluding cost of such specials and fixing to wall with necessary teak - Wood Plugs,PVC Clamps and screws,making holes on the wall or drilling holes in roof and making good the dismantled portions to original condition with necessary brick work and plastering wherever necessary with necessary scaffolding charges. (A)20mm dia
25mm dia
Wiring with 2 X 1.5 Sq.mm (22 / 0.3) PVC insulated SC unsheathed Copper conducutor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3 mm thick Hylum sheet cover with TW box And 5 A FT switch with continuous earth connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed Light point / fan point (For electronic Regulator) SD 25
Wiring with 2 X 1.5 Sq.mm (22 / 0.3) PVC insulated SC unsheathed Copper conducutor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 mm X 100 mm X 113 mm TW switch box with 3 mm thick Hylum sheet cover for 5 A 3 pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for concealed PVC plug point SD 38
Supply and run of 2 of 4.00 sqmm sqmm (22/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade in 25mm dia GI Pipe(Class B) suitably bent at both ends with necessary angle iron upright and end supports for mains on 3/20 GI bearer wire for Service connection mains(SD. NO 70)
Supply and fixing of WT bulk head fitting with guard suitable with 7W / 9W LED bulb -SD 84
Supply and fixing of tube light fitting including cost and conveyance of all materials to site and all labour charges etc complete SD 87
Supply and fixing of TNEB meter board suitable for 32A single phase service connection with 32A fuse unit (500V) 32A neutral link and earth link (1"x1/8" copper flat) on TW plank of size 375mmx300mmx19mm with supporting TWreepers of 1" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit with 1No 40Amp 30MA Double Pole RCD / RCCB (Higher End) with suitable necessary connection-SD125
Supply and fixing of 1200mm (48") AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp- SD 110
SHEIK UDUMAN HAKKIM (BID ID -1285451)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .