Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC | L1 | Accepted-AOC FIRST LOWEST BIDDER | |
| 2 | L2₹33.4 L+₹4.8 L (16.6%)Rejected-AOC | L2 | Rejected-AOC SECOND LOWEST BIDDER | |
| 3 | L3₹37.3 L+₹8.7 L (30.3%)Rejected-AOC 82 6 82 6 TRANSPORT NAGAR NARWAL NARWAL JAMMU JAMMU AND KASHMIR 180010 | JAMMU | JAMMU AND KASHMIR | 180010 | L3 | Rejected-AOC THIRD LOWEST BIDDER |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
12 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Nagrota
Garrison Engineer Nagrota Pin 901208 c/o 56 APO
REPAIRS REPLACEMENT OF MOTORS VOLTAGE STABLIZER PANELS ALONGS WITH DAY TO DAY COMPLAINTS AND CONNECTED ITEMS UNDER GE NAGROTA
2023_MES_596129_1
GEN-8522/2023-24
Open Tender
Civil Works
Works
270 days
Nagrota
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
₹92,000
Yes
1 Jul 2023
17 May 2023
19 Jun 2023
17 May 2023
12 Jun 2023
31 May 2023
Amount
Disconnecting the all electrical connection for taking out unserviceable centrifugal pump of any size from the foundation including other accessories , transporting to workshop & back to site for repair & re-installing he same after repair & testing complete all as specified and directed. Note: Spare parts shall be measured and paid under relivent items.
M & L for Replacement the following defactive part of centrifugel pumps Set are as under capacity 5 to 125 HP:-
Replacement of implers of existing size as directed by Engr-in-Charge
Replacement of gland bush including gland packing of existing size as directed by Engr-in-Charge
Replacement of pump shaft of existing sizeas directed by Engr-in-Charge
Replacement of neck ring of any size as directed by Engr-in-Charge
M& L for Remetaling, grinding, polishing and balancing of shaft for induction motor of capacity 5 to 10 HP. Note: (i) The rate for replacement of bushes, shaft sleeves etc required for making the shaft functional shall be included in the quoted rate).
All as per item No 3 above but of capacity 10 to 20 HP
All as per item No 3 above but of capacity 20 to 30 HP
All as per item No 3 above but of capacity 40 to 60 HP
All as per item No 3 above but of capacity 75 to 125 HP
Supply and fixing in replacement of ball bearing of induction motor/pump of cap 5 to 15 HP as per existing size complete all as specified and directed
Supply and fixing in replacement of ball bearing of induction motor/pump of cap 20 to 30 HP as per existing size complete all as specified and directed
Supply and fixing in replacement of ball bearing of induction motor/pump of cap 40 to 60 HP as per existing size complete all as specified and directed
Supply and fixing in replacement of ball bearing of induction motor/pump of cap 75 to 125 HP as per existing size complete all as specified and directed
Supply and fixing in replacement of star coupling suitable for connecting centrifugal motor and pump of capacity upto 125 HP complete all as specified and directed.
Supply and fixing in replacement of Tyre coupling suitable for connecting centrifugal motor and pump of capacity upto 125 HP complete all as specified and directed.
Material and labour for rewinding of centrifugal motor Upto 5HP capacity of any description, dismantling and strip opening of the motor, removing the old existing burnt windings, cleaning the slots and rewinding of the electric motor of 3 phase, 415 Volts, 50 Hz AC supply with existing gauge copper wire including insulating material such as illumines paper, etherized paper, cotton waste, glass sleeves insulating varnish etc, refixing on existing platform and connected all the electric connections and mechanical connections and testing the complete pumping set up to the entire satisfaction of the Engr-in-Charge complete all as specified and directed.
All as per item No. 14 above but capacity 5 HP to 15 HP
All as per item No. 14 above but capacity 15 HP to 20 HP
All as per item No.14 above but capacity 25HP to 30 HP
All as per item No. 14 above but capacity 35 HP to 40 HP
All as per item No. 14 above but capacity 50 HP to 60 HP
All as per item No. 14 above but capacity 60 HP to 75 HP
All as per item No. 14 above but capacity 125 HP.
Disconnecting the electrical connection for taking out unserviceable submersible pump set any size from the bore well including column pipe and other accessories carrying to workshop for repair complete all as specified and directed. Note:- (i) The T&P required for lifting and lowering for submersible pump set column pipe (any number) shall be provided by the contractor. (ii) Necessary safety precautions for workmen shall be the responsibility of the contractor. (iii) The cost of transportation to workshop is deemed to be included in the quoted rate.
M & L for Lowering the servicable submersible pump set any size after repair shifted to in its orignal location joint with column pipe and other accessories connecting to all electrical connection testing and commissioning the same complete all as specified and directed. Note: The cost of transportation from workshop is deemed to be included in the quoted rate.Necessary safety precautions for workmen shall be the responsibility of the contractor.
M & L for Replacement the defactive part of submersible pump sets are as under complete all as specified and directed.
Thrust plate of submersible motor 5 HP to 40 HP
Thrust bearing of submersible motor 5 HP to 40 HP
Gun metal bushes for submersible motor 5 HP to 40 HP
Remetaling,grinding,polishing and balancing of shaft for submersible motor 5 HP to 40 HP
Coupling arrangement with key of submersible motor of cap 5 HP to 40 HP
Stainless steel shaft of submersible pump of cap 5 HP to 40 HP
Impellers for submersible pump set 5 HP to 40 HP
Bowl bush for submersible pump set 5 HP to 40 HP
Neck ring for submersible pump set 5 HP to 40HP
M & L for removing old existing burnt winding of the submersible motor , cleaning the slots for rewinding, and rewinding the motor with super enamelled copper winding wire superior quality ( 99.99 % copper purity) as per exisitng gauge and size, varnishing, drying, replacement of bearings and assembling the motor of Capacity up to 12.5 HP complete all as specified and directed.
M & L for removing old existing burnt winding of the submersible motor , cleaning the slots for rewinding, and rewinding the motor with super enamelled copper winding wire superior quality ( 99.99 % copper purity) as per exisitng gauge and size, varnishing, drying, replacement of bearings and assembling the motor of Capacity 15 HP to 40 HP complete all as specified and directed.
Replacement of following body part of submersible pump set complete all as specified and directed.
M & L in replacement of sand guard assembely of 5 HP to 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of bush housing set including bush of 5 HP to 40 HP submersible Motor as existing make and size complete all as specified and directed.
M & L in replacement of upper housing set of 5 HP to 40 HP submersible Motor as existing make and size complete all as specified and directed.
M & L in replacement of lower housing set of 5 HP to 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of mechanical seal of 5 HP to 40 HP submersible Motor as existing make and size complete all as specified and directed.
M & L in replacement of seal guide sleeve of 5 HP to 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of startor assembly along with winding wire of 5 HP to 40 HP submersible Motor as existing make and size complete all as specified and directed.
M & L in replacement of roter assembly of 5 HP to 40 HP submersible Motor as existing make and size complete all as specified and directed.
M & L in replacement of cable connector sleeve and spring guide plate of 5 HP to 40 HP submersible Motor as existing make and size complete all as specified and directed.
M & L in replacement of tie rod/tie bolt of 40 HP submersible Motor as existing make and size complete all as specified and directed.
M & L in replacement of diaphragm along with diaphargm spring of 5 HP to 40 HP submersible Motor as existing make and size complete all as specified and directed.
M & L in replacement of doom nut and "O" ring of 5 HP to 40 HP submersible Motor as existing make and size complete all as specified and directed.
Disconnecting the electrical connection for taking out unserviceable VT Motor any size from the foundation of bore well and other accessories , transporting to workshop for repair, & transporting back to site as directd , reinstllaing the VT motor and making all electrical connection incl testing and commissioning complete all as specified and directed. Note: Spare parts shall be measured and paid under relevent items.
M & L for removing the burnt winding wire of the VT motor, cleaning the slots for rewinding, and rewinding the motor with super enamelled copper winding wire superior quality as per exisitng gauge and size, varnishing, drying, of Cap 30 to 40 HP complete all as specified and directed.
M & L for Lowering the VT pump any size after repair shifted to in its orignal location joint with column pipe,motor and other accessories connecting to all electrical connection testing and commissioning the same complete all as specified and directed.Note: The cost of transportation from workshop is deemed to be included in the quoted rate.
M & L for Replacement the following defactive parts of VT pump sets up to 40 HP Vertical turbine Motor complete all as specified and directed :-
Gun metal impeller
Neck Ring
Gland plate
Studs
Stainless steel line shaft 3 metre long
Top shaft 1.5 metre long
Guide spider 6"
Guide spider bush
Stainless steel sleeve
Shaft coupler
Stuffing box
Thrust bearing
B Kulf bush
Split Ring
Opening and checking and repair of fully automatic solid state CC-4A,CB-4SA,CC-4P,CC-4A models fault analyzer cum control system with (a) Low voltage cut off 350 Volt AC (b) High Voltage Cut off 450 Volt AC (c) Pick up volt 360 Volt AC (d) Cut off time- Fraction of time (e) Unbalanced volt cut off- a deference of 35Volt to 45 Volt between any two phase with 3 phase over load protection (f) Relay contact rating 5 Amps resistence at 230 V AC or 1 Amp at 415V AC (e) 4 LED fault indicators (Make: Guardian) once in a month to make it functional at all the times for smooth operation of pumping set installed at various location of water supply installations. Note : Minor parts of the system will be replaced during checking and the cost of the same is deemed to be included in the quoted rate.
Disconnecting the all electrical connections , taking out unserviceable votage stablizer of any size opening for repair automatic voltage stabilizer for automatic operation air natural/oil cooled servo controlled type input voltage 260-440V and output voltage 420 V capacity 25 to 400 KVA , transporting to workshop for repairs & transporting back to site as directed after repair , reinstalling the same incl commissioning & testing complete all as specified and as specified and as directed (Note :- (i) Cost of transportation of voltage stabilizer to workshop and back complete is deemed to be included in the quoted rate. (ii) Replacement of the parts if any found worn out/defective shall be measured and paid for separately.
Supply and fixing in replacement of dimmer coil with super enameled copper winding wire of existing make and size complete in all respect including varnishing tapping and insulating material to get same capacity of 25 to 400 KVA complete all as specified and directed.
Dismantling of primary and secondary coils carefully taking out winding wire preparing for rewinding with super enameled copper winding wire of appropriate guage with allied insulating material varnish the winding with air drying insulating varnish heat treatment etc of 25 KVA to 400 KVA complete all as specified and directed.
Supply and fixing in replacement of electronic circuit plate complete with DC transformers and shape (PCB cold) upto 400 KVA complete all as specified and directed.
Dismantling of old servo motor and supply and fix new servo motor of capacity upto 150 KVA Voltaze Stablizer and shape along with all connected accessories and cap complete all as specified and directed.
Dismantling of old carbon bush with carbon holder & S & F new carbon bush with carbon holder of capacity upto 400 KVA Voltaze Stablizer size and shape complete all as specified and directed.
Supply and fixing in replacement of brass studs fixed for upto 400 KVA Voltaze Stablizer input and output of stabilizer with brass nuts along with all necessary connection complete all as specified for any capacity of Voltage Stablizer complete all as specified and directed.
Supply heating and filling of transformer oil EHV grade having dielectric strength not less than 40 KV (Rms) with a 4 mm gap with high viscosity in transformer as per IS-335 of 1983complete all as specified and directed.
Painting to voltage stabilizer old painted surface of steel after cleaning scrapping and preparing and filling cavities and providing two coat of synthetic enameled cream paint with spray gun process to voltage stabilizer of cap upto 400 KVA complete all as specified and directed.
Supply and fixing in replacement, of power contractors 3 phase, 3 pole, 415 Volts, 50 Hz suitable for operation of a load of capacity of 70 Amps.complete all as specified and directed.
Supply and fixing in replacement, of power contractors 3 phase, 3 pole, 415 Volts, 50 Hz suitable for operation of a load of capacity of 110 Amps. complete all as specified and directed.
Supply and fixing in replacement, of power contractors 3 phase, 3 pole, 415 Volts, 50 Hz suitable for operation of a load of capacity of 185 Amps.complete all as specified and directed.
Taking down of manually operated oil immersed star delta starter of any capacity from its existing position, removing the transformer oil in a suitable container for reuse, replace the old unserviceable fixed and moving contract, over load coils, no volt coil complete and refixing the starter assembly in its existing position connecting the complete system and making the starter functional complete all as specified and directed.
Dismantling of reduction gear floculators/pre sedimentation tank type V 400 ratio 1:60 Make Radicon with replacement of V belts, gear oil repair to gears and shaft with greasing of the flocculator, alingnment complete all as specified and directed
M&L for making good and smooth postion of floculators track and wheel,dismantling the wheel and repair and greasing complete ,check the whole track and replace broken and unallined part of track complete for smooth functioning of flocculators complete all as specified and directed
M&L for repair for making good and functional of aluminium mixing plant including mixing drum , motor ,panel and other connecting items required to fully and smooth functioning of alum mixing plant complete all as specified and directed Note : All the repair & replacement of spare parts like bearing , gasket , gland packing , nuts bolts & washers , gear oil of motor etc & rewinnding of motor with super enemelled copper wire incl all labour cost is included in the quoted rates
Servicing / Maintenance of Air Blowers of adequate capacity (not less than 250 cfm) coupled with electric driven AC induction Motor of cap 20 HP three phase including carrying out maintenace check along with following repairs (a) Dismantling of Twin lobe commpressor in presence of MES representative and display all the parts without damage any portion for inspection of Engr in Charge to ascertain the serviceability of existing parts and assembling the same after filling compressor oil No 320 or as existing, upto indicated level. (b)Heating, varnishing to stator, rotor with super qualityvarnish and drying out properly. (c) Cleaning, washing and greasing of ball bearing complete. (d) Assembling of motor with old serviceable parts and replacement of UNSV parts with new as ordered where necessary. (e) Installation of motor by making connections as per existing and testing on load complete all as specified and directed. . Note:- Any minor repair and replacement of parts like bearing,gasket, gland packing, Nuts bolts washers, Gear oil of compressor etc and labour cost to be included in the quoted rates. (ii) Rewinding of motor if required shall be measured and paid to be included in the quoted rates
Supply and fix Flat three core PVC insulated & PVC sheathed industrial cable of size 6 Sqmm for submersible pump motors / centrifugal pumping set complete all as specified and directed.
Supply and fix Flat three core PVC insulated & PVC sheathed industrial cable of size 10 Sqmm for submersible pump motors / centrifugal pumping set complete all as specified and directed.
Supply and fix Flat three core PVC insulated & PVC sheathed industrial cable of size 25 Sqmm for submersible pump motors / centrifugal pumping set complete all as specified and directed.
Supply and fix Flat three core PVC insulated & PVC sheathed industrial cable for of size 35 Sqmmsubmersible pump motors complete all as specified and directed.
Supply and fixing in replacement of MCCB 400 Amps 4 pole 415 Volts 36 KA with adjustable thermal and adjustable magnetic settings fixed in repair as per existing at site complete all as specified and directed.
Supply and fixing in replacement of MCCB 250 Amps 3 pole 415 Volts 36 KA with adjustable thermal and adjustable magnetic settings fixed in repair as per existing at site complete all as specified and directed.
Supply and fixing in replacement of MCCB 200 Amps 3 pole 415 Volts 36 KA with adjustable thermal and adjustable magnetic settings fixed in repair as per existing at sitecomplete all as specified and directed.
Supply and fixing in replacement of MCCB 100 Amps 3 pole 415 Volts 16 KA fixed type as per existing at site complete all as specified and directed.
Supply and fixing in replacement of volt meter as per existing size complete all as specified and directed.
Supply and fixing in replacement of Amp meter with CT as per existing size complete all as specified and directed.
Supply, installation and commissioning and testing of LT panel cubical type CPRI Approved certified suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, floor mounted, outdoor type factory fabricated duly powder coated inside and out side, outer cover made out of 3.15mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6mm covered from all side with front and back openable, weather proof including suitable rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embeded in brickwork in CM 1:4 not less than 60cm above ground level with suitable foundation for fixing panel of required size in ground with nuts, bolts and washer etc. complete comprising of following including taking out the old unserviceable panel complete all as specified and directed.
Supply, installation and commissioning and testing of LT panel cubical type CPRI Approved certified suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, floor mounted, outdoor type factory fabricated duly powder coated inside and out side, outer cover made out of 3.15mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6mm covered from all side with front and back openable, weather proof including suitable rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embeded in brickwork in CM 1:4 not less than 60cm above ground level with suitable foundation for fixing panel of required size in ground with nuts, bolts and washer etc. complete comprising of following including taking out the old unserviceable panel complete all as specified and directed
Supply and fixing in replacement of indicator lamp assembly complete LED type suitable for the existing system supply voltage for the existing system supply voltage 230V / 440 V AC including taking down old lamp assembly complete all as specified and directed.
Supply and fixing flex sun board for Water supply installation of size 80x80 cm with ecosolvent print of thickness 5 mm complete all as specified and directed.
Supply and fixing copper thimble of following sizes complete all as specified and directed.
35 sqmm Heavy duty
50 sqmm Heavy duty
70 sqmm Heavy duty
90 sqmm Heavy duty
M&L for repair/rectification of leakage to water supply distribution lines 15 mm dia to 25 mm bore GI tubing by necessary excavation, returning/filling as required, tightening of loose joints of union, elbow, socket etc, threading if required including replacement of GI union/socket/nipple as required all as specified & directed by Engr in Charge Notes : (i) The complaints for the above works shall be registered by contractor at the water supply complaint cell of AGE E/M (ii) Stationary required such as complaint book, Complain slip etc shall be arranged by the contractor and proper record shall be maintained by the contractor. (iii) Tools and Transport with driver for attending of above complaints shall be arranged by contractor. (iv) The rate quoted by the contractor for above jobs under item No 68 to 71 shall be inclusive of cost of works under note (i) to (iii) above. (v) The above complaints shall be completed within 12 Hrs of the registration of the complaints. (vi) The stores required for the works under item No 68 to 71 shall be issued and measured separately under relevant item. (vii) Excavation, returning/ filling shall be measured and paid separately. (viii) Amount of 300 per complain will be panalised if complain is not attended with in 24 Hours
All as per Srl item No.68 above but for GI tubing of 40 mm bore to 50 mm bore
All as per Srl item No.68 above but for GI tubing of 80 mm bore to 150 mm bore
All as per Srl item No.68 above but for GI tubing of 150 mm bore to 300 mm bore
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep and getting out in hard/dense soil complete all as specified and directed
Returning /filling including watering , leveling , spreading and well ramming in layers not exceeding 25cm thick complete all as specified and directed at site.
Removing excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 50 metre above the starting point complete all as specified and directed at site.
M&L for Refixing/relaying of old steel tubing/UPVC pipe in new or old position with and including new fittings (Connections) and as per site requirement of following sizes complete all as specified and directed (Note : Excavation & earth work will be measured & paid separately )
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Taking down unserviceable GI tubing/ UPVC pipe complete with all fittings & connections of following sizes complete all as specified and directed (Note : Excavation & earth work will be measured & paid for separately )
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply, laying,testing and commissioning of GI tubing medium grade ISI Marked with all fittings such as elbow, bends, sockets, nipples,Tee,Flange, nut bolts ,Rubber gasket and union etc complete laid in trenches for following size complete all as specified and directed Note :- (i) Excavation and earth work shall be measured and paid seperately under relevant item of Sch A (ii) The rates quoted inclusive of cutting, jointing and testing of the pipe.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply & Fixing galvanised steel water tubing of medium grade with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc and fixed complete to walls and ceilings or laid in floors for the following sizes complete all as specified and directed Note:- (i) The rates quoted inclusive of cutting, jointing and testing of the pipe.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply and laying UPVC Pipe tubings medium grade pressure rating 10 Kgf/cm2 ISI Mark with all fittings such as elbow, bends, sockets, nipples and union etc and fixed complete laid in trench for different size as under complete all as specified and directed
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply only GI fittings, medium grade, ISI marked of following sizes complete all as specified and directed Note:- Rate of fixing of these items shall deemed to be included in item No. 68 to 69 above
Union 15 mm bore
Union 20mm bore
Union 25mm bore
Union 40mm bore
Union 50mm bore
Socket 15 mm bore
Socket 20 mm dia
Socket 25 mm bore
Socket 40 mm bore
Socket 50 mm bore
Elbow 15mm bore
Elbow 20mm bore
Elbow 25mm bore
Elbow 40mm bore
Elbow 50mm bore
Nipple 15 mm bore 50 mm long
Nipple 15 mm bore 100 mm long
Nipple 15 mm bore 150 mm long
Nipple 20 mm bore 50 mm long
Nipple 20 mm bore 100 mm long
Nipple 20 mmbore 150 mm long
Nipple 25 mm bore 50 mm long
Nipple 25 mm bore 100 mm long
Nipple 25 mm bore 150 mm long
Plug for 15mm bore
Plug for 20mm bore
Plug for 25 mm bore
Plug for 40 mm bore
Tee 15 x 15x 15 mm bore
Tee 20 x 20 x 20 mm bore
Tee 25 x 25 x 25 mm bore
Tee 40 x 40 x40 mm
Gland Paking 8 mm thick
Gland Paking 10 mm thick
Gland Paking 12mm thick
Reducer Socket 40mmX50mm thick
Reducer Socket 15mmX20mm thick
Reducer Socket 20mmX25mm bore
Union 32mm bore
Reducer Elbow 40mmX50mm bore
Reducer Elbow 20mmX25mm bore
Reducer Elbow 15mmX20mm bore
S&F gun metal gate valves with iron wheel head screwed at both ends for iron pipes complete including dismantling of old unserviceable gate valve fixed at any location all as directed for the all as directed for the following sizes:-
15 mm bore
20 mm bore
25 mm bore
32 mm bore
40 mm bore
50 mm bore
Supply in replacement for Repacking stuffing box of sluice valve, spindle including taking apart and reassembling valves and Taking out sluice valves refacing, regrinding and refixing of following sizes :-
80 mm bore
100 mm bore
150 mm bore
200mm bore
250 mm bore
300 mm bore
M&L for Servicing of sluice valves cast iron body by greasing/oiling using T&P as required as per manufacturer’s instructions & providing gland rope of superior quality to stop any leakage of sluice valves of size 80 mm to 150 mm diameter including replacement of defective brass check nuts complete all as specified and direceted.
All as per Srl item No. 83 above but 200 to 300 mm bore
M&L for attending breakdown of water supply pipe line and Repairs to CI water mains of size 80 mm to 200 mm bore at a given notice including necessary excavation in mud by using special T&P such as JCB, etc., dewatering from the trenches by using pumps, rectification of leakages, fixing of CI specials such as collars/bends/tails pieces and making joints complete all as specified and direceted. Note:-(i)The CI specials and lead joints shall be measured and paid separately (ii) The cost of necessary earth work and repair to damaged road shall deemed to be included in the quoted rates by the contractor and no extra payment shall paid on this account.
All as per item No. 85 above but for CI water mains of size 250mm to 300 mm boe
Supply only CI specials such as bends(any type , radius or angle) tappers any type, (straight, bend, increasing ,decreasing or double sockets etc) Tee Pieces, single Y branch,double branch cross( all sockets or socket or spigot) collars , caps , plugs etc upto 150 mm bore complete all as specified and directed at site. Note :- Fixing will be paid under item No. 70 & 71 above
All as per Srl item No. 87 above but 200 to 300 mm bore -ditto-
Supply only Connecting pieces one end flanged and other socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth of dia upto 150 mm bore complete all as specified and directed at site. Note :- Fixing will be paid under item No. 70 & 71 above
All as per Srl item No. 89 above but 200 to 300 mm bore
Supply and fix rubber gasket joint of following sizes of CI pipes complete all as per specified and directed
300 mm bore
250 mm bore
200mm bore
150 mm bore
100 mm bore
80 mm bore
Note:- Rate of fixing for item No. 91.01 to 91.06 shall deemed to be included in item No. 70 to 71 above
M&L for run lead joint for CI pipes of following sizes:-
300 mm bore
250 mm bore
200mm bore
150 mm bore
100 mm bore
80 mm bore
S&F spare parts for Dosing cum feeding pump of chloronome plant, gear type. .
Rotor assembly with bearing brackets and tollerance rings
coil assembly 250V 50 Hz.
Single head feed rate control with shaft
Pump Head ( Ferrules 1/4'' and duckbill included)
Roller assembly (Set of four)
Pump Tube (Set of Five)
Injection Check Valve 3/8" (Set of Five)
Pump Tube (Set of Five)
Weighted suction line strainer 3/8"
Ferrule 1/4" (set of 24)
Check valve for Duckbill (Set of 5)
Connecting nut 3/8" with adapter (set of 5)
Connecting nut 3/8"
Supply and fix in replacement,high pressure transparent type Suction/Discharge PVC pipe 3/8 '' bore outer of chloronome plant and shall be procured from OEM/ authorised dealer of OEM complete all as specified and as directed.
Taking down defective electric motor of dosing motor 1 HP cap and supply and fix in replacement of dosing motor 1 HP cap squirrel cage type single phase 230 volt 50 Hz cap re-installation at site complete and testing complete all as specified and as directed. Note The work to be carried out by OEM/ authorised dealer of OEM.only & the Contractor has to submit documentry proof for the same to GE while claiming payment.
M/S DC CONSTRUCTIONS
Balbir Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .