Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹7.0 LAdmitted-Finance 638 GROUND FLOOR WEST GURU ANGAD NAGAR LAXMI NAGAR LAXMI NAGAR EAST DELHI DELHI 110092 UDYAM DL 02 0031392 | EAST DELHI | DELHI | 110092 | -23.96% | ₹7.0 L | L1 | Admitted-Finance |
| 2 | L2₹7.1 L+₹8,838.42 (1.26%)Admitted-Finance DELHI EAST DELHI 110092 INDIA UDYAM DL 02 0018735 | EAST DELHI | DELHI | 110092 | -23.00% | ₹7.1 L+₹8,838.42 (1.26%) | L2 | Admitted-Finance |
| 3 | L3₹7.5 L+₹50,268.53 (7.18%)Admitted-Finance | -18.50% | ₹7.5 L+₹50,268.53 (7.18%) | L3 | Admitted-Finance |
Tender Value
₹9.2 L
EMD Value
₹18,500
Closing Date
8 Sept 2026, 11:00 amClosed
Puran Dass Kabeer
MUNICIPAL CORPORATION OF DELHI Office of the Executive Engineer E and M Central Zone Under Sewa Nagar Flyover , Lodhi Road , Delhi -03
Repair of pump set, LT panel and allied E and M equipment at Okhla, Siddarth, IP and SKK rub pumping station under SEZ
2026_MCD_289584_1
EE(EandM)/MCD/2026-27/37
Open Tender
Electrical Works
Percentage
15 days
Lodhi Road
Please refer Tender documents
3 documents required · 3 mandatory
₹590
₹18,500
10 Sept 2026
2 Sept 2026
9 Sept 2026
2 Sept 2026
8 Sept 2026
2 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Repairing of the following dia/models of storm water pump i/c dismantling of pump set from base frame by cutting of nut bolts of suction side and delivery side and holding of delivery line by dead flange and thrust support and suction line by holding with tripod arrangement i/c loading/unloading by skilled labour, to & fro cartage along with replacement of its parts/accessories i/c gland plate/spilt gland, MS Lock nut with Lock washer, Keys of impeller & coupling, stud of Gland plate and all packings i/c oiling, greasing, replacement of required body studs & nuts, coupling tyre, required machining works for proper balancing of complete pump unit and minor repair works and dynamic balancing with existing motor i/c installation, testing and commissioning on full load etc. as required complete in all respects. (Make: Kirloskar) Having suction of 200 mm (Model no. SHM 200/32) | 1 | Each | 64,154 | ₹64,154 |
| 2 | Replacement of Impeller of following dia/models of storm water pump etc. as required. (Make: Kirloskar) Having suction of 200 mm (Model no. SHM 200/32) | 1 | Each | 10,758 | ₹10,758 |
| 3 | Repairing of following rating Electrical Motor by rewinding, varnishing including dismentaling of motor from pump by heavy labour i/c loading , unloading, to and fro cartage , complete with repairing of connection plate,fan,fan cover and required balancing ,making connection,installation ,testing & commissioning on full load etc. as required complete in all respects.(old material will be retained by contractor). 125 HP | 1 | Each | 1,92,015 | ₹1,92,015 |
| 4 | Supplying and fixing of full stainless steel body self-contained drinking water cooler with cooling capacity 150ltr per hr, storage capacity 150 ltr and suitable for 230V supply as required. | 1 | Each | 62,000 | ₹62,000 |
| 5 | Supplying AND Installation of Reverse Osmosis (RO) water purifier of capacity 50 ltr/hr complete as required. | 1 | Each | 43,823 | ₹43,823 |
| 6 | S/I/T/C of 4 KVA Voltage Stabilizer having input voltage 150V-270V and output voltage 195-245V | - | Each | 3,361 | - |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) | - | Cumt | 7,294.7 | - |
| 8 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. | - | Each | 315 | - |
| 9 | Supplying and laying of following size of C PVC pipe in along with all accessories like socket, bend, couplers etc. conforming to IS :4985:2000, Part II complete with fitting and cutting, jointing etc. direct in ground ( 50 cm below ground level ) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. 25 mm dia | 30 | Metre | 156 | ₹4,680 |
| 10 | Supply and fabrication of pole protection system made up of 8 SWG steel wire mesh of size 25mm x 75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh i/c MV danger plate and grounding the protection system in suitable quality of CC etc as reqd. | - | sqm | 1,108 | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
NewGCC.pdf
Tender Documents • 22.34 MB
TandC.pdf
Other Document • 0.07 MB
BOQ_337839.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .