Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC 119 MONOHAR PUKUR ROAD KOLKATA 700 026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L1 | Accepted-AOC Lowest bid quoted | |
| 2 | L2₹23.5 L+₹62,659 (2.74%)Rejected-Finance 90 E BECHARAM CHATTERJEE ROAD KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | L2 | Rejected-Finance higher rate quoted | |
| 3 | L3₹24.5 L+₹1.6 L (6.90%)Rejected-Finance 230 S N ROY ROAD SAHAPUR COLONY KOLKATA WEST BENGAL 700038 | KOLKATA | WEST BENGAL | 700038 | L3 | Rejected-Finance highest rate quoted |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
11 Feb 2020, 3:00 pmClosed
EE II CKHED
P12 CIT Road 1st floor Kolkata 700014
Supply and installation of UPS at different Labs Eye Bank Emergency BMT Complex Radio Therapy Vaccination Oxygen Manifold etc at NRS Medical College n Hospital Modification of Existing Electrical Installation to Feed UPS source
2020_WBPWD_268196_1
WBPWD/EE-II/CKHED/NIT-54/19-20
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
NRSMCH
as per NIT
4 documents required · 4 mandatory
₹50,000
EE CKHED P12 CIT Road 1st floor Kolkata 700014
3 Sept 2020
24 Jan 2020
13 Feb 2020
24 Jan 2020
11 Feb 2020
30 Jan 2020
28 Jan 2020
Amount
SITC of wall mounted compartmentalised L. T. Cubicle type panel board made out of 2mm thick CRCA sheet with dust & vermin proof gasketted front door with mechanical locking arrangement and to be fixed on wall b y means of 4nos. heavy duty M.S. bullet fastner. The board to be painted by power coated paint including incorporating the following electrical accessories and making all necy. connections as per direction of E.I.C. (Approx. size :900mm. X400mm. X 250mm) : - i) Supplying and fixing 415 V 100A Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting and necessary connection [Make: Legrand] ............ 01 no. ii) Supplying and fixing 415V. 200A. 4-pole on load change over switch of open execute tion type[Make: L & T / ABB / HPL ]. .....................01 No. iii) Supplying and fixing 415 V 100A MCB of Breaking capacity 10kA & C characteristics on din rail [ make: Legrand]..................01 No. iv) inter connection between I/C MCCB to Change over to be done by 20mm X 5mm solid copper flat. This flats should have holes in convinent place for out going connection to MCB by 16Sq mm Copper wire incl socketting both ends. [ For 30KVA UPS]
SITC of wall mounted compartmentalised L. T. Cubicle type panel board made out of 2mm thick CRCA sheet with dust & vermin proof gasketted front door with mechanical locking arrangement and to be fixed on wall by means of 4nos. heavy duty M.S. bullet fastner. The board to be painted by power coated paint including incorporating the following electrical accessories and making all necy. connections as per direction of E.I.C. (Approx. size :900mm. X400mm. X 250mm) : - i) Supplying and fixing 415 V 63A Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting and necessary connection [Make: Legrand] ............ 01 no. ii) Supplying and fixing 415V. 125A. 4-pole on load change over switch of open executetion type with 3nos phase shorted by minimum 20mm X 3mm solid copper bar for UPS I/C source [Make: L & T / ABB / HPL ]. .......................01 No. iii) Supplying and fixing 415 V 32/25A MCB of Breaking capacity 10kA & C characteristics on din rail [ make: Legrand]..................01 No. iv) inter connection between I/C MCCB to Change over to be done by 20mm X 5mm solid copper flat. This flats should have holes in convinent place for out going connection to MCB by 16Sq mm Copper wire incl socketting both ends. [ For 20 & 10 KVA UPS]
Supplying and fixing 415V,16-32A per way , double door Horizontal TPN MCB Distribution board with IP-42/43 protection, with 4 pole isolator as incomer and SPMCB's ('C' curve,10kA) as outgoing with both side cable end boxes flushed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand / Siemens / Schneider / L&T)
6 way, 100A FP isolator as incomer &18 nos. SPMCBs as outgoing
4way, 63A FP isolator as incomer &12 nos. SPMCBs as outgoing
Supply & Fixing 240 V, 16 A -2no, 3 pin Modular type plug socket (Make- Legrand, Arteor/ Myrius) with 16 A -2no Modular type switch, without plug top on 6 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc, as to GS.
Distribution wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex / Polycab/ Havells /RR Kable) in 20mm/ 32mm/ 40mm size PVC rigid conduit 'FR' (Precision/ Polycab make) incl. necy. fittings as required
1x396/.4 (50sqmm) +3x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
1x 276/.4 (35Sqmm) +3x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
1x126/0.4 (16 sqmm)+3x84/0.3 (6 sqmm)+2 x 56/0.3 (4 sqmm) as ECC
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
1x396/.4 (50sqmm) +3x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
1x 276/.4 (35Sqmm) +3x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
1x126/0.4 (16 sqmm)+3x84/0.3 (6 sqmm)+2 x 56/0.3 (4 sqmm) as ECC
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Dismantling the Existing old UPS batteries after disconnection of all incoming & outgoing line etc. also carry this battery and dumped in to the store room, as directed by EIC.
Supply & replacement of 42 AH, 12V Mono Block batteries, as directed by EIC. [Make-Exide, Model no-EP42-12 or Amar Raja(Quanta)].
Supply & replacement of 65 AH, 12V Mono Block batteries, as directed by EIC. [Make-Exide, Model no-EP65-12 or Amar Raja(Quanta)].
Supply & replacement of 100 AH, 12V Mono Block batteries, as directed by EIC. [Make-Exide, Model no-EP100-12 or Amar Raja(Quanta)].
Supply & replacement of 120 AH, 12V Mono Block batteries, as directed by EIC. [Make-Exide, Model no-EP120-12 or Amar Raja(Quanta)].
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
SIMPSON AND FERRIS PVT LTD
switching avo Electro Power Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .