| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC | L1 | Accepted-AOC AOC awarded to M/s Shiv Enterprises | |
| 2 | L2₹20.5 L+₹2.3 L (12.4%)Rejected-Finance 46 HUSENI LAKDA BAZAAR 242 BELLASIS ROAD MUMBAI 400008 | MUMBAI | MAHARASHTRA | 400008 | L2 | Rejected-Finance Being not lowest |
| Sl No | Description | Qty | Unit | SHIV ENTERPRISE L1 | Unitech Enterprises L2 |
|---|---|---|---|---|---|
| 1.00 | Dismantling roof (corrugated, semi corrugated etc) sheets in roof coverings including ridges, complete all as specified and directed. | 70 | Sqm | 25 ₹1,750 Lowest | 25 ₹1,750 Lowest |
| 2.00 | S & F Pre- painted galvalumealuminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified including scafoldings of any hieght, complete all as specified and directed. | 60 | Sqm | 545 ₹32,700 Lowest | 650 ₹39,000 |
| 3.00 | S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr in charge. | 10 | Sqm | 545 ₹5,450 Lowest | 700 ₹7,000 |
| 4.00 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. | 3.9 | Qtl | 410 ₹1,599 | 300 ₹1,170 Lowest |
| 5.00 | Supply & fix joist, channel, angle, tee sections, & MS flats fixed independently, with/without connection plate, etc. (cut to ordinary lenghts i.e. within 20mm of the length indicated) use for single stanchions, purlins,rafter incl plate,nut boltand necessary fixing arrangemenr fixed to wooden rafters and all other similar works conforming to Fe 410-W (Gde-E-250), complete all as specified and directed by Engr in Charge. | 600 | Kg | 60 ₹36,000 Lowest | 100 ₹60,000 |
| 6.00 | Demolition of cement concrete in sunken portion unreinforced, complete all as specified and directed. | 1.2 | Cum | 1,000 ₹1,200 | 800 ₹960 Lowest |
| 7.00 | Material and labour for PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation filling, mass concrete and sunken floor treatments, complete all as specified and directed. | 1.2 | Cum | 3,550 ₹4,260 Lowest | 5,000 ₹6,000 |
| 8.00 | M & L for Water proofing treatment to sunken slab /floors/walls etc and shall be carried out as specified below and as directed. (a) Cleaning the sunken portion of Toilet/bath/WC/Kitchen throughly to remove the laitance, dirt etc and thrown out side the MD land. (b) Form angle fillet of size 50 mm x 50 mm along the junction of wall and floor using polymer modified mortar, Apply one coat of polymer coating on all angle fillets by brush and cover it with 100 mm open glass fibre / geotextile fibre mesh when it is still wet. Apply second coat of the same coating on the angle fillet and allow it to dry completely. Make PIDILITE (Dr fixit Pidicrete URP)/ASIAN (smarcare repair polymer)/ FOROC/BASF/SIKA/Equivalent. (c) Sanitary pipe entering through walls and floor shall be sealed with bitumin based seal tape / epoxy bonding agent and gaps to be grouted with non shrink cementitious grout. Nahani traps etc to be fitted securely and gaps around it to be grouted in the same manner. Make : PIDILITE(Dr fixit epoxy bonding agent or bathseal tape )/ AISAN (Smartcare apcorap epoxy bonding agent)//Equivalent. | 8 | Sqm | 570 ₹4,560 Lowest | 750 ₹6,000 |
| 8.01(d) In the remaining area in dry substrate condition brush apply first coat of the acrylic cementitious coating and further apply second coat in perpendicular direcion after 6-8 hours when first coat is dry, and sprinkling quartz sand for shearkey purpose on secon coat in wet condition and allow to dry it completely, Extend the coating up to 1.2 mm above the FFL. Coverage of cementitiou coating to be maintained of min 1.8 kg per sqm for two coats. Make : PIDILITE(Dr fixit fastflex)/ASIAN (ultrablock 2K)/BASF/FOSROCK/SIKA/Equivalent. (e) Sunken portion to be tested for 72 hours for water tightness after only flooring work can be started. Cost for the same shall be deemed to be included in quoted rate. (f) After 2 to 3 days sunken portion must be overlaid with a 50 mm thick concrete screed 1:3:6 type B0 mixed with integral WPC liquid laid to slope 1:60 towards outer face of wall. Provide 40 mm OD CPVC pipe at the lowest point with 600 mm projection beyond the outer face of the wall, then filled up the sunken portion with lean concrete 1:4:8 type D-2. (Note : lean concrete 1:4:8 paid saperatly). Note : All the material involved in sunken treatment shall be deemed to be included in quoted rate and only floor area will be measured for the payment purpose. | |||||
| 9.00 | M & L rendering 10mm thick on fair faces of brick work or concrete surfaces in Cm 1:4, complete all as specified and directed. | 8 | Sqm | 145 ₹1,160 Lowest | 200 ₹1,600 |
Tender Value
₹24.7 L
EMD Value
₹49,420
Closing Date
11 Dec 2025, 6:00 pmClosed
Kameshwar Prasad, IDSE, EE
GE(West), Colaba, Mumbai - 400 005
SPECIAL REPAIRS TO TOILET, SUNKEN TREATMENT AND EXTERNAL FACIA OF GE (W) COLABA UNDER AGE B/R CENTRAL OF GE (W) COLABA, MUMBAI
2025_MES_740635_1
8142/E8
Open Tender
Civil Works
Item Rate
180 days
GE(West), Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (W) Colaba, Mumbai
₹49,420
Yes
15 Jan 2026
20 Nov 2025
13 Dec 2025
20 Nov 2025
11 Dec 2025
4 Dec 2025
Amount
Dismantling roof (corrugated, semi corrugated etc) sheets in roof coverings including ridges, complete all as specified and directed.
S & F Pre- painted galvalumealuminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified including scafoldings of any hieght, complete all as specified and directed.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr in charge.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
Supply & fix joist, channel, angle, tee sections, & MS flats fixed independently, with/without connection plate, etc. (cut to ordinary lenghts i.e. within 20mm of the length indicated) use for single stanchions, purlins,rafter incl plate,nut boltand necessary fixing arrangemenr fixed to wooden rafters and all other similar works conforming to Fe 410-W (Gde-E-250), complete all as specified and directed by Engr in Charge.
Demolition of cement concrete in sunken portion unreinforced, complete all as specified and directed.
Material and labour for PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation filling, mass concrete and sunken floor treatments, complete all as specified and directed.
M & L for Water proofing treatment to sunken slab /floors/walls etc and shall be carried out as specified below and as directed. (a) Cleaning the sunken portion of Toilet/bath/WC/Kitchen throughly to remove the laitance, dirt etc and thrown out side the MD land. (b) Form angle fillet of size 50 mm x 50 mm along the junction of wall and floor using polymer modified mortar, Apply one coat of polymer coating on all angle fillets by brush and cover it with 100 mm open glass fibre / geotextile fibre mesh when it is still wet. Apply second coat of the same coating on the angle fillet and allow it to dry completely. Make PIDILITE (Dr fixit Pidicrete URP)/ASIAN (smarcare repair polymer)/ FOROC/BASF/SIKA/Equivalent. (c) Sanitary pipe entering through walls and floor shall be sealed with bitumin based seal tape / epoxy bonding agent and gaps to be grouted with non shrink cementitious grout. Nahani traps etc to be fitted securely and gaps around it to be grouted in the same manner. Make : PIDILITE(Dr fixit epoxy bonding agent or bathseal tape )/ AISAN (Smartcare apcorap epoxy bonding agent)//Equivalent.
(d) In the remaining area in dry substrate condition brush apply first coat of the acrylic cementitious coating and further apply second coat in perpendicular direcion after 6-8 hours when first coat is dry, and sprinkling quartz sand for shearkey purpose on secon coat in wet condition and allow to dry it completely, Extend the coating up to 1.2 mm above the FFL. Coverage of cementitiou coating to be maintained of min 1.8 kg per sqm for two coats. Make : PIDILITE(Dr fixit fastflex)/ASIAN (ultrablock 2K)/BASF/FOSROCK/SIKA/Equivalent. (e) Sunken portion to be tested for 72 hours for water tightness after only flooring work can be started. Cost for the same shall be deemed to be included in quoted rate. (f) After 2 to 3 days sunken portion must be overlaid with a 50 mm thick concrete screed 1:3:6 type B0 mixed with integral WPC liquid laid to slope 1:60 towards outer face of wall. Provide 40 mm OD CPVC pipe at the lowest point with 600 mm projection beyond the outer face of the wall, then filled up the sunken portion with lean concrete 1:4:8 type D-2. (Note : lean concrete 1:4:8 paid saperatly). Note : All the material involved in sunken treatment shall be deemed to be included in quoted rate and only floor area will be measured for the payment purpose.
M & L rendering 10mm thick on fair faces of brick work or concrete surfaces in Cm 1:4, complete all as specified and directed.
Demolition of brick work built in CM including all quoins arches pillars etc and precast articles includings disposal of demolished material as directed by Engr-in-Charge.
Material and Labour for Brick work with sub class 'B' brick straight or curved on plan exc 6 mtr mean raddius built in CM 1:6, ccomplete all as specified and directed by Engr in Charge.
Dismantling of floor hearth/wall tiles including cement mortar bedding (but not backing) and removing serviceable tiles, complete all as specified and directed.
M&L for Virified Ceramic tiles 8-10 mm thick (square/ rectangular)polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match Coloured in floor including 15mm thick screed bed or bedding layer in CM 1:6, complete all as specified and directed.
M&L for Coloured vitrified tiles of 8-10 mm thick ,area of each tiles 0.42 sqm but not exceeding 1.00 sqm as in skirting and dados etc including 10 mm thick rendering coat in CM (1:4) set and jointed in neat cement slurry and pointed in coloured cement to match, complete all as specified and directed.
M&L for Non skid coloured ceramic tiles 7 to 8 mm thick, area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors including 15mm thick screed bed or bedding layer in CM (1:6) set and jointed in neat cement slurry and pointed in coloured cement to match, complete all as specified and directed.
M&L Glazed ceramic tiles in vertical surface size 600 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade including 10mm thick rendering coat in CM 1:4, complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc., complete all as specified and directed.
M&L Granite (of any type and size) 18-20 mm thick machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over 15mm thick screed bed in CM 1:4 on kitchen platform, Cill of Window/Ventilator/ flooring/border etc including rubbing, grinding and polishing, complete all as specified and directed.
Taking down cement plaster on brick /stone walls/ ceiling etc incl racking out of joints hacking for key scrubbing down with water to receive plaster, including complete and disposal of rubbish out of the MD land. Note Height of the bldgs five & above upto eight stories, including use of scaffolding, complete all as specified and directed.
M & L for applying average 15-20mm thick plaster in two coats with readymix prepacked proportioned dry mix mortar, blended with PP fibers, mixed with liquid water proofing compound on other than fair faces/fair faces of brick wall or concrete surfaces additives, on external surfaces including transporting of material, mixing, curing, scaffolding etc., complete all as specified and directed. Note :- Liquid water proofing compound will be measured and paid seperately as supply only.
Supply only integral water proofing compound, complete all as specified and directed.
M & L for Providing and applying average 12-15 mm thick plaster in two coats in cement mortar 1:4 for with readymix prepacked proportioned dry mix mortar, blended with PP fibers, on internal surfaces including transporting of material, mixing, curing, scaffolding etc., complete all as specified and directed.
Material and Labour for applying one coat of wall care putty 1 mm Average thickness (after finishiing or rubbing) on wall/ceiling surface incl rubbing through authorised applicators, complete all as specified and directed.
M&L for preparing new plastered surfaces of walls /ceiling and applying two coats of oil bound distemper over a coat of alkali resistant primer complete incl scaffolding, complete all as specified and directed.
Material and Labour for complete removal of existing treatment of old surface of wall/ceiling and applying two coats of oil emulsion distemper incl a coat of putty 1 mm thick after finishing through authorised applicators of paint manufacturers only of approved shade, complete all as specified and directed.
Material and Labour for preparing newly plastered surfaces of walls / ceilings for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, through authorized applicator only including use of scaffoldings, complete all as specified and directed.
Taking down chowkat with shutters (without taking off shutters from the frames) area exc 1.5 sqm but nexc 4 sqm, complete all as specified and directed.
Taking down chowkat with shutters (without taking off shutters from the frames ) area nexc 1.5 sqm each, complete all as specified and directed.
Supplying and fixing factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat comprising of 50 x 100mm size applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length, complete all as specified and directed.
S & F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 28-30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed.
SS & F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both s factory made 30 mm thick flush shutter solid core construction with Particle board core and plywood face panells commercials type on both sides, complete all as specified and directed.
S & F Powder coated (any shade approved by GE) aluminium frame/shutter for door, window, ventilator,partions of any type including sliding/hunge type all as directed with one more rebates including fabrication of frame/shutters and fixing to wall with necessary lugs, cleat etc including all accessories such as glazing clips and rubber beading for fixing of glass panes, hinges locks, etc, complete all as specified and directed. (i) Glass panes/Wire cloth will be measured and paid seperately. (ii) The quoted rate rate shall be inclisive of cost of rubber beading,glazing clips and locking arrangement. (iii) Joint shall be completed using silicon gun is incl in quoted rate.
S&F sheet glass 4 mm thick ordinary quality in square exc 0.5 sqm in each pane and fixed with rubber beads, complete all as specified and directed.
S&F sheet glass 4 mm thick ordinary quality in square n.exc 0.5 sqm in each pane and fixed with rubber beads, complete all as specified and directed.
S&F Door closer, aluminium body (extruded section) hydraulically regulated designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg, complete all as specified and directed by Engr in charge.
S&F in repair Door closer, aluminium body (extruded section) hydraulically regulated designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg, complete all as specified and directed by Engr in charge.
S&F aluminium anodised barrel tower bolt 200 mm long of extruded section, complete all as specified and directed by Engr in charge.
S&F aluminium alloy anodized sliding door bolt 300mm long with hasp and staple fixing clips etc, complete all as specified and directed.
S&F Anodised aluminium alloy handles cast type, each 150mm long, complete all as specified and directed by Engr in charge.
S & F Mild steel butt hinges medium weight cold rolled 100 mm long, complete all as specified and directed by Engr in charge.
M&L for preparation of new steel surfaces of any description not otherwise described over 10cm in widht or girth and applying two coats of synthetic enamel paint, complete all as specified and directed by Engr in charge.
M&L for preparation of old painted steel surfaces of any description not otherwise described over 10cm in widht or girth and applying one coat of synthetic enamel paint, complete all as specified and directed by Engr in charge.
M&L preparing old wooden surfaces of any description not otherwise described over 10cm in width or girth and applyingone coat of synthetic enamel painting, complete all as specified and directed.
M&L preparing new wooden surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel painting over a coat of pink primer, complete all as specified and directed.
Supply and fixing Aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperature 1.40mm and fixed with aluminium wire staples, complete all as specified and directed.
Supply and fixing in repair Aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperature 1.40mm and fixed with aluminium wire staples, complete all as specified and directed.
Supply & fixing in repair single piece vitreous china Wall Hung WC Rimless Bowl With Cistern and PP Soft Close Seat cover, Hinges, Dual Flush Cistern Fitting, Accessories Set, Size: 380x650x730 mm brown or any colour as decide by Engr in charge including making connection to trap and to flushing pipe etc complete and making good to floor, complete all as specified and directed. Make : Jaguar Model no FLS-WHT-5353PPZ or equivalent.
Supply & fixing in repair Health foucet including PVC pipe 1.50m long with brass nuts for EWC, fixed complete all as specified and directed Make : Jaguar Model No ALD577
Supply & fixing in repairs vitreous china cream Countertop wash basin size 425 x 340 x 175 mm excluding taps, waste, chain, and plug but including brackets & cutting for and pinning in end of brackets or erecting stand or neccessay fixing accessories, complete all as Specified and directed. Make : Jaguar Model No CNS WHT 903 or equivalent.
S&F 40mm Low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sqcm, complete all as specified and directed.
S&F in repairs PVC connection 15mm size with PTMT nuts of length 450 mm, complete all as specified and directed.
S&F in repairs brass chromium plated tubular towel rail 20 mm dia, D type 60 cm long, between flanges complete fixed, complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed.
S&F PVC (SWR) 110mm bore pipes single socketed in any length with rubber ring joints fixed to wall/floor complete in repair all as specified and directed.
S&F PVC (SWR) 75mm bore pipes single socketed in any length with rubber ring joints fixed to wall/floor complete in repair all as specified and directed.
S&F PVC (SWR) 75mm bore bends any radius, complete all as specified and directed.
S&F PVC (SWR) 110mm bore bends any radius, complete all as specified and directed.
Material and labour for PVC nahani trap with grating 75mm dia outlet jointed to waste pipe fixed in cement concrete type B-1 (1:2:4) in repairs, complete all as specified and directed.
Taking up or down steel tubing and connections 15 mm bore, including cleaning for refixing or removal, complete all as specified and directed.
Supply and fix GI tubing medium grade 15mm bore laid to walls and ceiling or laid in floors, complete all as specified and directed.
Supply & fix in repairs, stop cock, (Consealed type) cast copper alloy screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union of size 15mm, complete all as specified and directed.
S&F in repair toilet coloured paper holder, vitreous China, box typer all as per specifications, complete all as specified and directed.
S&F Grating round 140 mm size of PTMT. (Minimum weight 50gms), complete all as specified and directed.
S&F in repairs angle cock chromium plated 15 mm bore dia, complete all as specified and directed.
S&F in repair 15 mm Pillar taps, fancy type with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, complete all as specified and directed.
S&F in repair 15 mm dia bib taps cast copper alloy with Chromium plated cruch or butterfly handle scrwed, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
Supply and fixing in repair Shower arm 15 mm size, 195mm long withbend of 45degree with flange of PTMT any colour. (Minimum weight 40gm), complete all as specified and directed.
S & F in repair of 18 mm thick Both Side pre laminated HDHMR Board of any colour, Matt surface finish, grade I as per IS 14587, for frame and shutter with 18mm wide pvc strrips lipping for kitchen cabinets complete including dismentling any type board, complete all as specified and directed by Engr-in-charge.
M &L for Drilling Holes of 12mm dia, upto 100mm deep holes in structural members at the intervals of 300 to 500mm in staggered manner or along the crack as directed by the Engr-in-charge in RC structural element including Cleaning of the holes by air blower and Inserting 12mm dia. Teflon nozzles compatible with epoxy injector and having machined external end to receive outlet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing and allow to cure the system for min.8 hrs before grouting including removing nozzle projections, excess putty if any over concrete element grinding, levelling and finishing the external surface, after completion of the work, etc, complete all as specified and directed. Note : Grouting material will be paid seperately. Drilling of hole shall be done by authorized applicator and the work shall be executed in the presence of company representative.
Injection Grouting to arrest Porosity: supply only Injection grouting material to arrest porosity, Injection resin shall be hydroswelling, water based, low-viscous, thermo-setting resin based on vinyl metha-acrylate chemistry. The Injection resin shall have re-swelling capacity up to 2.5 times by volume in potable water. The injection resin shall contain accelerator to regulate the setting times and shall not of expanding foaming type product or non-swelling formulation. The injection resin shall be effective in saline water by exhibiting positive expansion. Typical Material Properties: Chemical base : Acrylate polymer Mixed Density : 1.065 kg/litre Viscosity : < 40 cps at 20oC Application temperatures : +5 degree C to 40 degree C Pot life : 20 – 60 Minutes at 20 degree C Setting time : 1 – 2 Hours, complete all as specified and directed. Note :- Method of application and material for grouting may be adopted as per manufacturers insturctions of slecected Make complete all as specified and directed.
Examining concrete by tapping with light hammer and marking of the loose concrete areas of structural elements in straight line geometrical forms, grooving the edges same with grinder up to 5 - 10 mm depth without damaging existing rebars, carefully removing carbonated concrete around the rebars up to 10 mm depth by low impact high frequency hammer/chipper without damaging the sound concrete, in detailed methodology, daily cleaning and stacking of debris at prescribed location, complete all as specified and as directed.
M & L for Cleaning of existing reinforcement with wire brush/ rotary wire brush to make surface free from rust scales, loose material, dirt etc. complete with rust remover and Treat all the rusted reinforcement using single component, water based, rust converter before treating with anti-corrosive primer. The rust converter shall be capable of forming tough protective layer of iron phosphate Typical Properties of Rust Cleaner: Aspect : Pale yellow/brown, liquid Mixed density : 1.2 to 1.45 kg/litre, complete all as specified and directed. Note : Method of application and Material for rust remover may be adopted as per manufacturers insturctions of slecected Make complete all as specified and directed.
M & L for the Anti-corrosive Primer for Rebars, primer shall be a two component, epoxy zinc rich. It shall be formulated to meet the requirement of BS 4652 Type 2. The primer shall be an active type having zinc content of greater then 90% in dry film state which is capable of negating the generation of incipient anodes in the areas surrounding the repairs. The product shall have mix density not less than 2.25 kg/litre. It shall be fully compatible with wide range of repair mortars. Typical Properties of Primer: Aspect : Thick grey suspension, Mixed density : 2.3 kg/litre, Volume Solids, % : 50 ± 3, Mixing Ratio, by weight : 96(B): 04(H), Pot Life : >2 Hours at 25°C, Tack free time : 20 Minutes at 25°C 5 Minutes at 40°C Recoat time : 5 Hours at 25°C 2 Hours at 40°C D.F.T. per coat : > 50 microns Application temperature : Minimum 10°C Maximum 40°C, Note :- Method of application and material for anticorrosive primer may be adopted as per manufacturers insturctions complete all as specified and directed.
Providing and application of hitech concrete penetrating, water based, organic, Bi-polar, calcium nitrite free, migratory corrosion inhibitor on concrete surface having Ph 9.5 hich migrates to a virtual extent of 100 mm inside concrete through pores, to inhibit the corrosion process on embedded steel at both anodic and cathodic ends by depassivating the Electro-chemical reaction in that region thereby protecting rebar on all sides. Note :- Method of application and material for anticorrosive primer may be adopted as per manufacturers insturctions complete all as specified and directed.
Identifying and marking carefully the damaged reinforced concrete by tapping with light hammer and chipping of unsound weak concrete and plaster material from slab/beams/columns etc. with power/hand driven chisel as directed by the engineer-in-charge upto 25 mm average depth (for PMM) including saw-cutting of all edges making square shoulders of the cavities including, complete all as specified and as directed. Note:- 1. All loose unsound and cracked concrete shall be removed out side MD land cost for the same deemed to be included in the quoted rate. 2. thickness shall be measured excluding plaster.
Identifying and marking carefully the damaged reinforced concrete by tapping with light hammer and chipping of unsound weak concrete and plaster material from slab/beams/columns etc. with power/hand driven chisel as directed by the engineer-in-charge upto 40 mm average depth including saw-cutting of all edges making square shoulders of the cavities including complete all as specified and as directed. Note:- 1. All loose unsound and cracked concrete shall be removed out side MD land cost for the same deemed to be included in the quoted rate. 2. thickness shall be measured excluding plaster).
Identifying and marking carefully the damaged reinforced concrete by tapping with light hammer and chipping of unsound weak concrete and plaster material from slab/beams/columns etc. with power/hand driven chisel as directed by the engineer-in-charge upto 40 to 150 (avg depth) mm average depth including saw-cutting of all edges making square shoulders of the cavities including complete all as specified and as directed. Note:- 1. All loose unsound and cracked concrete shall be removed out side MD land cost for the same deemed to be included in the quoted rate. 2. thickness shall be measured excluding plaster).
M & L for Rebuilding the section of damaged RCC elements to its original size or as per consultants recommandations in average thicknesses of 40-100 mm by providing and casting with microconcrete of grade M-40 and above including providing and fixing of watertight form finish shuttering of minimun 18 mm thick with supporting formwork, shear connector, hilti rebars, all lead, lift, mixing, placing, deshuttering,curingand levelling the surface by grinding off cementitious slurry or construction joint differences if any to satisfaction of Engr-in-Charge, complete all as specified and as directed. Note:- Formwork incluing Steel Props required for rebuilding of damaged RCC elements deemed to be included in the quoted rate. for repair beyond 100 mm it may be necessary to mix properly graded 5 mm to 12 mm saturated surface dry aggregate, it can added 20 to 25 % by weight of micro concrete.)
M & L for Rebuilding the section of damaged RCC elements to its original size or as per consultants recommandations in average thicknesses of upto 40 mm by providing and casting with microconcrete of grade M-40 and above including providing and fixing of watertight form finish shuttering of minimun 18 mm thick with supporting formwork, shear connector, hilti rebars, all lead, lift, mixing, placing, deshuttering,curingand levelling the surface by grinding off cementitious slurry or construction joint differences if any to satisfaction of Engr-in-Charge, complete all as specified and as directed. Note :- Formwork incluing Steel Props required for rebuilding of damaged RCC elements deemed to be included in the quoted rate. for repair beyond 100 mm it may be necessary to mix properly graded 5 mm to 12 mm saturated surface dry aggregate, it can added 20 to 25 % by weight of micro concrete.)
S & F for TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height, complete all as specified and as directed.
S & F for TMT bars 5 mm dia and over up to 10 mm, in stirrups, spaces and binders, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and as directed.
Demolition of re-inforced cement concrete at Roofs, floors (other than ground floors), beams, staircases, landing,chajjas and similar suspended work (Reinforcment cut as required to facilitate demolition) in any position, complete all as specified and directed.
Dismantling wall and ceiling boards or insulation boards, any thickness, any description, including cover fillets, complete all as specified and directed.
S&F Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions, complete all as specified and directed.
M&L Aluminium anodised snap grid frame work for false ceiling size 600x600mm complete including GI suspenders, expansion hold fasteners etc, fixed as directed by Engr-in-Charge, complete all as specified and directed.
Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling, complete all as specified and directed.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitable modular or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light point controlled by one switch. Note:- Switch, socket and fan regulators to be measured and paid for separately. PVC Conduit confirming to IS 9537 part I & III Note (All chases will be cut by chase cutter only).
Description all as per Srl item No. 89 here in before but for one light point contolled by two way switches, with cable 1.50 sqmm.
Description all as per Srl item No. 89 here in before but for socket outlet point 5 Amp on same board.
Description all as per Srl item No. 89 here in before but for socket outlet point 5 Amp on Independent board.
Description all as per serial item No. 89 above but with 4 sqmm cable for 3 pin 15 Amps switch socket outlet (Power point).
Supply and fixing modular switch 1 way 6 A module 230/250 volt, AC supply, ISI Marked, with white cover plate with frame, complete all as specified and directed.
Supply and fixing modular switch 2 way 6 A module 230/250 volt, AC supply, ISI Marked, with white cover plate with frame, complete all as specified and directed.
Supply and fixing modular switch 1 way 16 A module 230/250 volt, AC supply, ISI Marked, with white cover plate with frame, complete all as specified and directed.
Supply and fixing modular sockets 6A 2/3 pin combined 2 module 230/250 Volts, 50 Hz, AC supply, ISI Marked, with cover plate, complete all as specified and directed.
Supply and fixing modular sockets 6A/16A 2/3 pin combined 2 module 230/250 Volts, 50 Hz, AC supply, ISI Marked, with white cover plate with frame, complete all as specified and directed.
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal, complete all as specified and directed.
Supply and fixing in repair LED lights fitting 1x 20W, 220V, AC decorative box type, warm white / white type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete pre wired fixed to wall with 2 nos PVC block of suitable size, complete all as specified and directed.
Wall bracket decorative light fancy kight fitting warm white/white type with lamp 12 Watt complete with necessary connection, complete all as specified and directed.
S & F LED down lighter square/round light fitting warm white /white type with lamp 12 Watt complete with necessary connection, complete all as specified and directed.
S & F Exhaust fan 230 volts, 250mm, plastic body including making all electric connection complete all as specified and as directed including cutting of hole on wall and makng good disturbed surface of wall and outer wooden box for fan fix on wall, complete all as specified and directed.
S&F in MCB Distribution board, 240 volts single pole and neutral, double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, including taking down old, complete all as specified and as directed.
S&F in repairs MCB DP, 240 Volts, 40 Amps, 10 kA rupturing capacity 'C' series, complete all as specified and as directed.
S&F in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB's, complete all as specified and as directed.
Supply and fix in repairs MCCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting, complete all as specified and directed. (Note : MCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule. Note : Copper thimble shall be used for connection of cable .
Supply and fix MCCB TPN, 240 Volts, 63 to 100 Amps, 10 kA rupturing capacity 415 Volts, complete all as specified and directed including taking down old one.
Supply and fixing of hot water Geysers of 25 ltrs capacity 5 star rated vertical type includng fixing of bolts, nuts grouted into the wall and necessary cement work, making good of disturbed surface of wall, giving electric, hot and cold water pipe, tab etc and water connection and testing after installation. Make : Havells cat part no - GHWASEIBO25 /LG/Ronald.
Supply & laying galvanized steel tubing, medium grade laid in trenches/floor/wall and joined including necessary fittings such as bends, elbow, tees, sockets, etc for 15mm dia pipe, complete all as specified and directed.
Material & Labour for Sub main wiring, with two run of 10 sqmm stranded copper conductor PVC unseathed FRLSH wire along with 10 sqmm green colour wire as earth contuinity conductor connected to common earth dolly including PVC FR heavy duty conduite of adequate size (not less than 32 mm dia) for housing the wires for from Pannel / Main DB to house SPN DB including taking down old Unsv submain with all associated fixtures complete all as specified & as directed by engr-in-charge. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Note: Mode of measurement two runs of 10 sqmm cable and one run of 10 sqmm cable with PVC conduite shall be measured as one length.
M & L Sub main wiring with two run single core 4 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia Cassing capping ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc complete all as directed. Note: (i) Two runs of 4 sqmm and one run of 4 sqmm cable and one run of PVC conduit shall be measured as one RM.
M & L Sub main wiring with two run single core 1.50 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia Cassing capping ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 1.50 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc complete all as directed. Note: (i) Two runs of 1.50 sqmm and one run of 1.50 sqmm cable and one run of PVC conduit shall be measured as one RM.
Material and labour for earthing complete with galvanised steel earth plate electrode 60 cm X 60 cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I.
M & L for galvanised iron strip 25x3mm earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or or buried in ground or drawn in conduit/pipe or fixed to poles in roof of high rise bldg and as required by saddles not more than distatance of 50 cm between two saddles with jointing nuts, bolts /washers to wall/surface or recess of high rised buildings or burried in ground or any situation for loop, complete all as specified and directed by the Engineer-in-Charge.
Supply, lay in trenches, floors, fix on wall/pole, passing through pipes etc., LT UG cable, 1100 volts grade, PVC/ XLPE insulated, with multistranded aluminium conductors, armoured with galvanised steel wire or tape, gland, lugs etc, of size 25 Sqmm 3.5 core, confirming to IS specifications, complete all as specified and directed.
Unitech Enterprises (BID ID -3494933)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
8142TenderPages.pdf
Tender Documents • 1.61 MB
BOQ_829343.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .