Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹47.0 L
EMD Value
₹93,974
Closing Date
24 Oct 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE AF
KANGAYAMPALAYAM
PROVISION OF ADDITIONAL AC AND ALLIED E/M WORKS FOR CERTAIN LABS/TECH STORES AT 5 BRD AND PROVISION OF WATER SOFTENERS AT VARIOUS LOCATIONS AT AFS SULUR
2026_MES_792297_1
8927/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF SULUR
PLEASE REF TO TENDER DOCUMENT
6 documents required · 6 mandatory
₹500
GE AF SULUR
₹93,974
Yes
3 Oct 2026
3 Oct 2026
26 Oct 2026
3 Oct 2026
24 Oct 2026
17 Oct 2026
3 Oct 2026 - 9 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, testing and commissioning of inverter type split Air conditioner of capacity 2.0TR, 5star rated, indoor and outdoor units complete with non-CFC refrigerent gas R-32 / R407c / R410a etc, minmum inverter type, turbo cooling, rotary compressor BLDC type, wide air flow blade, wide powerful air throw, with minmum filters as required, adjustable temperature settings, active dehumidifier, auto restart 24 hrs timer, auto cooling fan mode with adustable variable speed settings, operating on 230 Volt single phase AC supply, 50Hz and also compitable for wide range of voltage variations (i.e 170V -260V) with cordless remote control unit, display, adjustable swing, noise level less than 45db for indoor unit and filter configuration complete including necessary all electrical and mechanical connections as required for complete operation of AC unit and necessary fixing arrangement as per relevant IS (indoor unit at suitable place and height inside the room and out door unit at suitable place and as directed) including metallic bracket with fixing place suitable size and length bolts for outdoor unit and including necessary insulated copper piping and drain pipe etc complete all as specified and as directed. | 41 | Each | 100 | ₹4,100 |
| 2 | S&F 5 KVA capacity Voltage stabilizer for automatic operation, single phase naturally air cooled , copper wound, indoor type & designed for input variation between 170V - 250V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as per manufacturers instructions complete all as specified and as directed. | 41 | Each | 100 | ₹4,100 |
| 3 | S&F Factory made powder coated Distribution board TPN 4 way, double door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and directed. | 3 | Each | 100 | ₹300 |
| 4 | S&F Factory made powder coated distribution board SPN 8 way, single door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and directed | 6 | Each | 100 | ₹600 |
| 5 | S&F Single pole and neutral MCB 40 to 63 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and directed | 6 | Each | 100 | ₹600 |
| 6 | S&F Triple pole and neutral MCB 40 to 100 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and directed | 3 | Each | 100 | ₹300 |
| 7 | S&F Sub main wiring with 4 runs of 6.00 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cable drawn through and including PVC conduit and conduit accessories concealed in wall, ceiling etc. ISI marked 32mm dia(external) with conduit accessories fixed on wall / roof and one run of 6 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cable as earth conductor complete as specified and directed. | 84 | RM | 100 | ₹8,400 |
| 8 | S&F Sub main wiring with 2 runs of 4.00 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cable drawn through and including PVC conduit and conduit accessories concealed in wall, ceiling etc. ISI marked 32mm dia(external) with conduit accessories fixed on wall / roof and one run of 4 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cable as earth conductor complete as specified and directed. | 200 | RM | 100 | ₹20,000 |
| 9 | S&F Sub main wiring with 2 runs of 6 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cable drawn through and including PVC conduit and conduit accessories concealed in wall, ceiling etc. ISI marked 32mm dia(external) with conduit accessories fixed on wall / roof and one run of 6 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cable as earth conductor complete as specified and directed. | 90 | RM | 100 | ₹9,000 |
| 10 | S&F SP 6 To 32 Amps rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning, 10 KA breaking capacity confirming to IS 8828 of 1996 complete as specified and directed. | 60 | Each | 100 | ₹6,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
TENDER_8927.pdf
Tender Documents • 0.74 MB
BOQ_888356.xls
BOQ • 0.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .