Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC NO 229 ANGAPPAN STREET MITTANAMALAI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L1 | Accepted-AOC BeingL1 | |
| 2 | L2₹15.8 L+₹36,290 (2.34%)Rejected-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹21.1 L+₹5.6 L (36.2%)Rejected-AOC | L3 | Rejected-AOC Not being L1 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
18 Aug 2022, 6:00 pmClosed
Garrison Engineer, Avadi
Garrison Engineer, Muthapudupet, Avadi, Chennai 600 055
REPAIR AND MAINTENANCE OF CEILING FAN, EXHAUST FAN, AIR CIRCULATORS, CABIN FAN INCLUDING CONNECTED WORKS AND WELCOME MAINTENANCE OF INTERNAL ELECTRIFICATION INCLUDING MISC REPAIRS IN MARRIED ACCN OF ARMY AREA UNDER GE AVADI
2022_MES_539482_1
8945
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer, Muthapudupet, Avadi, Chennai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer, Avadi
₹50,000
Yes
21 Oct 2022
20 Jul 2022
25 Aug 2022
20 Jul 2022
18 Aug 2022
4 Aug 2022
Amount
Taking down carefully the Ceiling fan of any size/ make after disconnecting the electric connections for necessary servicing and replacing the spares, rewinding etc., all as specified and directed. Note : Servicing, Spares, Refixing and Rewinding shall be measured and paid for separately.
Taking down carefully the Exhaust fan of any size/ make after disconnecting the electric connections for necessary servicing and replacing the spares, rewinding etc., all as specified and directed. Note : Servicing, Spares, Refixing and Rewinding shall be measured and paid for separately.
Taking down carefully the Wall-mounted/ Air-circulator fans of any size/ make after disconnecting the electric connections for necessary servicing and replacing the spares, rewinding etc., all as specified and directed. Note : Servicing, Spares, Refixing and Rewinding shall be measured and paid for separately.
Labour only for servicing the ceiling of any size/ make including greasing/ oiling/ repairs and replacing the spares such as cater pin unserviceable/rusted nut bolts, split pins rubber wheel bearing washers, bush , and connected items all as specified and directed
Hanging only ceiling fan any sweep any make, 230 V single phase and connecting up with PVC insulated cable size 1.50 sqmm three core copper conductor round cable complete all as specified. Note:- The refixed fan shall be tested after fixing the blades.
Fixing only Exhaust fans along with louver any description any make, 230 V single phase and connecting up with PVC insulated cable size 1.50 sqmm three core copper conductor round cable including grouting of nut, bolt on existing location and complete all as specified and directed. Note : The refixed fan shall be tested after fixing the blades.
Fixing only Wall-mounted/ Air-circulator fans of any description any make, 230 V single phase and connecting up with PVC insulated cable size 1.50 sqmm three core copper conductor round cable including necesary fixing arrangements if existing fixing arrangements found unserviceable, on existing location etc., complete all as specified and as directed. Note : The refixed fan shall be tested after fixing the blades.
Material and Labour for painting of ceiling fans of any sweep to obtain even, smooth & glossy finish, with synthetic enamel paint of approved colour by using paint spraying devices after filling cavities with filler after cleaning all dust etc., over fan surfaces; complete including writing SM/MES No. in synthetic enamel paint (Black colour) over the same surface where the existing No. was written etc., all as specified and as directed.
Material and Labour for painting of Exhaust/ Pedestal/ Wall-mounted/ Air-circulator fans of any sweep to obtain even, smooth & glossy finish, with synthetic enamel paint of approved colour by using paint spraying devices after filling cavities with filler after cleaning all dust etc., over fan surfaces; complete including writing SM/MES No. in synthetic enamel paint (colour as approved) over the same surface where the existing No. was written etc., all as specified and as directed.
Material and Labour for rewinding of fan motor with super enameled copper winding wire of same gauge and weight after cutting and removing the existing burnt/heated up windings, including cleaning of rotor, stator and varnishing, heating and providing fresh insulating materials for Ceiling fan of 1200/1400 mm sweep including dismantling and reassembling.
All as per Item No.10 herein before but for Exhaust fan 225 to 300mm sweep
All as per Item No.10 herein before but for Pedestal fan 400 to 600mm sweep
All as per Item No.10 herein before but for Wall mounted fan 400 sweep
Supply only ball bearing suitable for ceiling fan of size 1200/1400mm sweep
Supply only ball bearing suitable for exhaust fan of any size and make
Replacement of old/unserviceable capacitor of capacity 2.5 µfd for the fans in position as directed.
Replacement of old/unserviceable capacitor of capacity 4 µfd for the fans in position as directed.
Supply and fix PVC canopy/Ceiling fan cap with fixing screws etc suitable for ceiling fan 1200/1400mm sweep etc., complete; all as specified and as directed
Supply and fix ceiling fan blade with fixing accesories etc suitable for ceiling fan 1200/1400mm sweep etc., complete; all as specified and as directed
Supply and fix exhuast fan blade (metal body) with fixing accessories etc suitable for exhaust fan 300mm sweep etc., complete; all as specified and as directed
Supply and fix exhuast fan louver (shutter) metal body with fixing accessories etc suitable for exhaust fan 300mm sweep etc., complete; all as specified and as directed
Taking down down rods of ceiling fans (1200/1400 mm sweep) fixed by means of check nut and split pin, 'U' clamp bolts, nuts, washers, rubber split pin check nut etc., complete; all as specified and as directed.
Supply and Fix ceiling fans down rods fabricated out of 15 mm dia GI pipe medium grade duly cutting/ threading/ drilling etc. Suitable for ceiling fans (1200/1400 mm sweep) fixed by means of check nut and split pin, 'U' clamp bolts, nuts, washers, rubber split pin check nut etc., complete; all as specified and as directed.
Taking down existing un serviceable check nut and split pin including 'U' clamp bolts, nuts, washers, rubber split pin check nut etc., complete; from ceiling fan 1200/1400 mm sweep etc., all as specified and as directed.
Supply and Fix check nut and split pin including 'U' clamp bolts, nuts, washers, rubber split pin check nut etc suitable for ceiling fan 1200/1400 mm sweep etc., complete; all as specified and as directed. Note for item No. 1 to 24:- Repairs/ painting shall be carried out only to the fans where SM No. is available over the fans and the contractor shall ensure the same before carrying out such repairs/ painting.
Supply and Fix ceiling fan hook made out of 40 x 6 mm MS flat iron and 10 dia MS round bar bend to shape for hanging ceiling fans including taking down existing unserviceable fan hook complete; all as specified and as directed.
Rectifying faults by attending faults of point/sub main wiring complaints (excluding fittings and fixtures) any rating/ make/ model/ type in position including testing of serviceability of point wiring, finding of fault/ defect and repairing, jointing of wires/ cables properly with required jointing materials and making wiring functional etc., complete; all as specified and directed. Note:- (i) The rate quoted is deemed to be inclusive of cost of the required materials like insulation tape etc where required. (ii) Provn of point/sub main wiring including taking down of the same will be paid under relavent items. (iii) Contractor or his accredited Engineer/ representative shall collect the list of daily complaints from Complaint Cell. (iv) Contractor shall submit the daily list of all rectified/ non-rectified complaints to the Engineer-in-charge at the end of the day's work on each working day of unit/ AGE's office.
Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets, light fittings, fans etc., removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc., complete all as specified and as directed.
M & L for point wiring with 1.5 Sqmm (nominal area) PVC insulated,FRLSH unsheathed, multistrand, 1100 volts grade copper conductor cable single core, drawn through with and including non metallic PVC conduit 20mm dia and its accessories fixing on wall/ceiling/trusses with suitable clamps , screws etc including one run of 1.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, 1.6 mm thick MS terminal box finished to wall with 3 mm thick laminated hylam sheet top cover all as specified for :-
One light point controlled by one switch.
One Ceiling fan point controlled by one switch.
One exhaust fan/wall mounted fan point controlled by one switch.
One 3 pin 5 amps socket point on independent board
One 3 pin 5 amps socket point on same board
One bell / buzzer point controlled by one bell push
M & L for point wiring with 4 Sqmm (nominal area) PVC insulated,FRLSH unsheathed, multistrand, 1100 volts grade copper conductor cable single core, drawn through with and including non metallic PVC conduit 20mm dia and its accessories fixing on wall/ ceiling/ trusses with suitable clamps , screws etc including one run of 4 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, 1.6 mm thick MS terminal box finished to wall with 3 mm thick laminated hylam sheet top cover all as specified for One 5 pin 5/15 amps socket point on independent board complete all as specified
Point wiring on stone / brick masonry wall complete with two 1.5 sqmm single core PVC insulated FRLSH ,1100 volts grade unsheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc., and including provision of one 1.5 sqmm PVC insulated single core multistranded copper conductor FRLSH green in colour as earth continuity conductor and connected to common earth dolly, including 1.6 mm thick MS terminal box finished to wall with 3 mm thick laminated hylam sheet top cover all as specified for following:-
One light point controlled by one switch.
One Ceiling fan point controlled by one switch.
One exhaust fan/wall mounted fan point controlled by one switch.
One 3 pin 5 amps socket point on independent board
One 3 pin 5 amps socket point on same board
One bell / buzzer point controlled by one bell push
M & L for point wiring with 4 Sqmm (nominal area) PVC insulated,FRLSH unsheathed, multistrand, 1100 volts grade copper conductor cable single core, drawn through with and including non metallic PVC conduit 25mm dia and its accessories concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc including one run of 4 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, 1.6 mm thick MS terminal box finished to wall with 3 mm thick laminated hylam sheet top cover all as specified for One 5 pin 5/15 amps socket point on independent board complete all as specified
M&L Pointing wiring in Existing conduit with 1.5 Sqmm (nominal area) PVC insulated,(FRLSH) unsheathed, multistranded, 1100 volts grade copper conductor cable single core, drawn through existing PVC/ steel heavy duty conduit 20 mm dia conduit including one run of 1.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, 1.6 mm thick MS terminal box finished to wall with 3 mm thick laminated hylam sheet top cover for one light/fan/5 Amp socket all as specified and directed.
M&L Pointing wiring in Existing conduit with 4 Sqmm (nominal area) PVC insulated,(FRLSH) unsheathed, multistranded, 1100 volts grade copper conductor cable single core, drawn through existing PVC/ steel heavy duty conduit 20 mm dia (concealed) conduit including one run of 4 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, 1.6 mm thick MS terminal box finished to wall with 3 mm thick laminated hylam sheet top cover for 15 Amp socket all as specified and directed.
S&F Switch piano flush type, single pole,5 Amps, 240 volts complete all specified.
S&F Switch socket 3 pin 5 amps , multi pin , flush type,complete all specified.
S&F Switch socket 3 pin 15 Amps, multipurpose, flush type complete all specified.
S&F ceiling rose 65 X 50 mm , three terminals ,bakelite , surface complete all specified.
S&F electronic fan regulator, flush type phenolic laminated sheet etc complete all as specified.
S&F Bell , ding-dong type , AC, 215 volts, 50 HZ complete all as specified.
S&F Bell push, flush type, single pole, 5 Amps, 240 volts complete all specified.
S &F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified.
Supply and Fixing of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified.
Point wiring on stone / brick masonry wall complete with two 1.5 sqmm single core PVC insulated FRLSH ,1100 volts grade unsheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc., and including provision of one 1.5 sqmm PVC insulated single core multistranded copper conductor FRLSH green in colour as earth continuity conductor and connected to common earth dolly, including steel box of required module for modular switches/sockets and regulators all as specified complete for following:- Note : Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
one light point controlled by one switch.
One Exhaust fan point controlled by one switch.
One ceiling fan point controlled by one switch and regulator
One bell / buzzer point controlled by one bell push
One switch socket outlet 3 pin 5 Amps on same board along with other switches
One switch socket outlet 3 pin 5 Amps on independent board.
All as per item No 49 here-in-before but for point wiring with two 4.0 sqmm single core copper conductor multistranded FRLSH cable and one 4.0 sqmm PVC insulated single core multistranded cable as earth continuity conductor green in colour including steel box of required module for modular switches/sockets all as specified for one 3 pin switch socket outlet, 15 Amps, complete all as specified and as directed.
Supply and Fixing Modular switch 1 way 6A, 1 module complete all as specified.
Supply and Fixing Modular switch 1 way16A, 1 module complete all as specified.
Supply and Fixing Modular Bell push 6A, 1 module complete all as specified.
Supply and Fixing Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified.
Supply and Fixing Modular Socket, 6A/16A - 2/3 pin combined 2 module complete all as specified.
Supply and Fixing Modular fan step regulator , 120w, 2 module complete all as specified.
Supply and Fixing Modular White cover plate with frame,1 module complete all as specified.
All as per item No 57 here-in-before but 2 module complete all as specified.
All as per item No 57 here-in-before but 3 module complete all as specified.
All as per item No 57 here-in-before but 4 module complete all as specified.
All as per item No 57 here-in-before but 6 module complete all as specified.
All as per item No 57 here-in-before but 8 module complete all as specified.
Fixing only LED tube light fitting 20/22 watt connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all fixing accessoreis all as specified and directed. Note :- LED Tube light fittings with bulb shall be issued under Sch 'B' free for fixing only.
Fixing only LED tube light fitting 10 watt connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all fixing accessoreis all as specified and directed. Note :- LED Tube light fittings with bulb shall be issued under Sch 'B' free for fixing only.
Fixing only LED Bulb 9/12/15 watt, B-22 base suitable for operation on AC, single phase complete all as specified and directed. Note :- LED Bulb shall be issued under Sch 'B' free for fixing only.
Supply and fix Decorative ECO bulkhead luminaire capacity 10/12W, environmental friendly ultra modern energy saving surface mounted, LED luminaire comprising of high brightness and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ includint taking down fitting complete all as specified. Make :- Luker :- Eco Bulkhead (LBKOVSL12) /Crompton :- LBHP-10-CDL / Surya :-SLE BH 10W
Supply and fix LED building security light 25W, made up of pressure die cast housing with toughed glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 incuding drivers, connecter block etc complete pre wired & connecting up with suitable twin core flexble copper wire and suitable bracket all as per dirtected including taking down old light complete all as specified. Make :-C&S ( INDUS-i/25W) / Bajaj :- BCLST 25W LED I V2 /Crompton :- LSTS-25-CDL-M
Supply and Fixing of Rigid non-metallic PVC conduit for 25mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc with suitable TV socket box complete all as specified.
Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting to common earth dolly complete including taking down unserviceable submain wiring with accessories complete all as specified and as directed.
Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, four runs of single core 10 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 10 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor concealed in walls and fixed with suitable pvc conduit with clamps on ceiling / roof trusses etc. and connecting to common earth dolly complete including taking down unserviceable submain wiring with accessories all as specified and as directed.
Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor fixed on walls ceiling / roof trusses etc with fixing accessories complete and connecting to common earth dolly complete including taking down unserviceable submain wiring with accessories complete all as specified and as directed.
Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, four runs of single core 10 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 10 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor fixed on wall/ ceiling / roof trusses etc. and connecting to common earth dolly complete including taking down unserviceable submain wiring with accessories all as specified and as directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 40-63 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN and current carrying capacity 40-100 Amp in the DB complete with connection testing and commissioning complete all as specified.
S&F MCB DB SPN 8 way, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming and Outgoing MCB measured separately relevent items.
S&F MCB DB SPN 4 way, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming and Outgoing MCB measured separately relevent items.
S&F Vertical Load line DB TP&N 4 way, double door, powder coated, 415 volts, AC, 50Hz, IP 54 protected, fixed on wall semi flush with provision for FP MCCB 100 Amps as incomer and SP MCBs 40 / 63 Amps as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming MCCB and Outgoing MCB measured separately relevent items.
S&F MCB DB TPN 4 way, distribution DB double door, powder coated, 415 volts, AC, 50Hz, IP 54 protected, fixed on wall semi flush with provision for TPN MCB 63 Amps as incomer and SP MCBs 40 Amps as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming MCB and Outgoing MCB measured separately relevent items.
S&F MCCBs100 Amps 415V,16KA, 4 Pole complete all as specified .
Material and labour for earth continuity conductor or main earthing lead fixed to valve on batten or recess or chases or burried in ground or drawing in conduit or any other situation for loop earthing etc as reqd 4 mm dia galvanized steel wire all as specified and directed by Engr-in-Charge
Earthing complete with galvanised iron earth plate electrode 600mm X 600mm X 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
PSK Enterprises
RADHIKAGANESH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .