| 1 | L1₹15.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.6 L+₹93,410 (5.97%)Rejected-Finance 142 JAGJIVANRAM NAGAR GAROBA MAIDAN NAGPUR 440008 | NAGPUR | NAGPUR | MAHARASHTRA | 440008 | L2 | Rejected-Finance Being higher bidder | |
| 3 | L3₹17.2 L+₹1.5 L (9.81%)Rejected-Finance LOKMAT BHAWAN A WING 808 WARDHA ROAD RAMDASPETH NAGPUR 440010 | NAGPUR | MAHARASHTRA | 440010 | L3 | Rejected-Finance Being higher bidder |
Tender Value
₹19.7 L
EMD Value
₹39,350
Closing Date
9 Jun 2023, 6:00 pmClosed
CWE (AF) AGRA
HQ CWE (AF) AGRA PIN 282008
SPECIAL REPAIR TO TOILET AT VARIOUS LOCATION AT AF STN SONEGAON
2023_MES_595075_1
80022-33/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) (AF) Sonegaon
As per Tender Documents
9 documents required · 9 mandatory
₹500
AGE (I) (AF) Sonegaon, Nagpur
₹39,350
Yes
1 Aug 2023
12 May 2023
12 Jun 2023
12 May 2023
9 Jun 2023
26 May 2023
Amount
Demolition of plain cement concrete in ground floor and paving not exceeding 15cm thickness below or above ground level including removal of same to exceeding 1 KM but not exceeding 1.5 KM complete all as specified and directed.
Taking down cement plaster on brick wall or concrete surface etc including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
Taking down chowkhats or frame n.exc 1.50 Sqm each with shutter (without taking of shutter from framed) complete incl removing from site complete all as specified and directed.
Taking down chowkhats or frame exc 1.50 Sqm but n.exc 4 Sqm each with shutter (without taking of shutter from framed) complete incl removing from site complete all as specified and directed.
Taking up or down steel tubing and connection of 15 mm bore complete all as specified and directed.
Taking up or down steel tubing and connection of 20 mm bore complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittins,heads,shoes,bends,swan-necks,etc including removing from site complete all as specified and directed.
Demolition of brick work built in cement mortar complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling cast iron work of any description complete all as specified and directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick wall built in CM (1:4) complete all as specified and directed.
M&L for brick work using sub class B bricks straight of curved on plan exc 6m mean radius built in CM (1:4) complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:6) on wall finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:4) with using WPC (WPC shall be measured seperetly)on wall finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for 10 mm thick cement plaster in cement mortar 1:3 for ceiling, finished even & smooth without using extra cement complete all as specified and directed.
S&F in repair for 10 ltrs capacity flushing cistern PVC low level valve less, symphonic action type flushing cistern white with inlet, ball valve, float and handle including brackets and 32 mm flush pipe of polyethylene complete all as specified and directed.
S&F in repair 15mm dia angle stop valves cast copper alloy fancy type,chromium plated complete all as specified and directed.
S& F in repair Toilet paper holder of vitreous china fixed to walls with chromium plated (CP) brass screws complete all as specified and directed.
S&F in repair tubular towel rail 20mm dia brass chromium plated, D type, 60 cm long between flanges complete all as specified and direcetd.
S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 meter long flexible tube and abs wall hook including making connections and fixed in position complete all as specified and directed.
M&L for steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 410-W (Gde-E- 250) quality-A complete all as specified and directed.
S &F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410-W (Gde-E- 250) quality-A complete all as specified and directed.
S &F mild steel screw bolt,16 to 20mm dia machine made with hexagonal head at one and screwed the other or screwed bolts each screwed and to be filled with washer and one hexagonal or square nut exc 10cm and not exc.15cm long complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coated galvanised Iron based corrugated steel sheeting 0.5 mm thick, with side lap and end lap of any colour having tensile strength 550 MPA ridges, hips, valley gutters, drip and straight flashing or in roof covering fixed with self taping screws (length & girth as fixed) complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F 1000 ltr capacity Rotational moulded polyethylene water storage tank (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I,including 20 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod &highdensity plastic ball screwed for iron pipe including dismantalling of existing water tanks and removinging from site complete all as specified and directed.
Disconnecting existing tank of capacity exc. 500 & n.exc 1000 ltrs, setting aside lowering if required for repairs cleaning etc and hoisting if required reconnecting and refixing in position including cleaning and removing all scale and dirts from tank and from mouth of pipe etc complete all as specified and directed.
S&F in repair for PVC connection pipe of 15 mm dia and 45 cm long to WHB and flushing cistern complete all as specified and directed.
S&F steel tubing and connection tubing in new or old position to walls, ceiling, floors etc including all fitting as socket,elbow,nipple,union etc complete all as directed at site for 15 mm bore complete all as specified and directed.
S&F steel tubing and connection tubing in new or old position to walls, ceiling, floors etc including all fitting as socket,elbow,nipple,union etc complete all as directed at site for 20 mm bore complete all as specified and directed.
S&F in repair 20mm bore stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed.
S&F in repair, 15mm bore bib taps cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed.
S&F in repair, 15mm bore stop valve cast copper alloy, fancy type chromium plated with long shank and cup (concealed) screwed down,high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed.
S & F in repair 15 mm dia pillar taps, fancy type , chromium plated, screwed down high pressure with long screwed shanks and fly nuts, serewed for iron pipe & fixed complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone agg as in coping, bed plate etc complete all as specified and directed.
S&F mild steel works as in small articles like hold fasts, conforming to Fe-290 or Fe E-165 complete all as specified and directed.
S&F frame work such as grills, grating etc with ends of bars shouldered and or rivetted or forged into spikes, framed guard bars, barred iron doors, ladders etc and similar wks conforming to Fe-290 Gd E-165 complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube S&F in opening all as shown on drawing complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30 mm thick style consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheets strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail and bottom rail on either side and as gap inside for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded/seated to the stiles and rail with suitable PVC sheet bending and jointed to gather with solvent cement supplying and fixing in the frame at site as per specification and drawing complete all as specified and directed.
S&F extruded aluminium alloy butt hinges 100mm size type B-21 complete all as specified and directed.
S&F 150 mm long aluminum anodized barrel tower bolt extruded section complete all as specified and directed.
S&F aluminum handles cast type anodize 150 mm long complete all as specified and directed.
S&F aluminium alloy anodized sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast alumionium alloy and fixed 300mm long complete all as specified and directed.
S&F in repairs for shower rose chromium plated with or without swivel joints 125 mm dia complete all as specified and directed.
M&L for applying three coats of white wash on newly plastered surfaces on wall after necessary preparation of the surface, complete all as specified and directed.
M&L for applying three coats of white wash on newly plastered surfaces of ceilings after necessary preparation of the surface, complete all as specified and directed.
M&L for preparation of old decorated surface of walls by brooming down and wire brushing etc and applying one coat of white wash on wall complete all as specified and directed.
M&L for Preparation of old plastered or unplastered surfaces of ceiling and applying one coat of white wash to ceiling complete all as specified and directed.
M&L for preparing the new plastered surfaces of wall and applying Two coat of cement based paint complete all as specified and directed.
M&L for preparing the old surfaces by complete removel of existing treatment and applying two coat of cement based paint on walls complete all as specified and directed.
Taking down existing roof treatment including cleaning and removal of deberis from the premises to a distance n. exc. 1.5 KM complete all as specified and directed.
Supply only liquid water proofing compound ISI marked complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 450 x 350 x 6-7 mm thick in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surface with & including rendering 10 mm thick in cement mortar 1:4 on other than fair faces of brick wall finished rough to fix tiles complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick joint less (square or rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, but without glazing bars complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S &F 4mm thick Figured glass, pin head type and glazing with oil putty in squares not exc 0.5 sqm in each pane complete all as specified and directed.
M&L 25 mm thick PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate for bedding layer of tiles/Kota stone complete all as specified and directed.
M&L for 110mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls complete all as specified and directed.
M&L for 75mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls complete all as specified and directed.
S&F PVC (SWR) bends 110 mm bore of any radius complete all as specified and directed.
S&F PVC (SWR) bends 75 mm bore of any radius complete all as specified and directed.
S&F PVC (SWR) junction single (singleT) equal or unequal 110mm bore provided with access door complete all as specified and directed.
S&F PVC (SWR) junction single (singleT) equal or unequal 75mm bore provided with access door complete all as specified and directed.
S&F 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F 75 mm dia outlet PVC (SWR) floor trap plain with steel grating including jointing with solvent cement complete all as specified and directed.
S&F 110mm dia PVC (SWR)WC connector with lip ring complete all as specified and directed.
S & F in repair vitreous china wash basin, white, flat back, size 550 x 400 mm including bracket fixed to wall complete all as specified and directed.
S & F in repair Vitreous china wash water closet pan ( Pedestal pattern) white fixed in floor including trap, connecting to drain ( or outgoing pipe ) and flush pipe, anti syphonage pipe, flush pipe to pedestal pan including all joints etc complete all as specified and directed.
S&F plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminized hinging device complete all as specified and directed.
S&F vitreous china squatting pan ORRISA Pattern of size 580x 440mm white with integral foot rest and 's'or 'p trap'complete (excluding cistern and flush pipe) with provn of lime concrete including backing joints complete all as specified and directed.
S&F in repair vitreous china urinal, half stall type white (excluding flushing cistern, flush pipe and waste pipe)including PVC waiste pipe 1 m long complete all as specified and directed.
M&L for repair and rendering 10mm thick in CM 1:3 on chajjas not exceeding 60cm width after removing cracked plaster and concrete including cleaning of visible reinforcement and treating with cement slurry also necessary repair to cracked concrete if any with cement concrete (1:2:4) Type B-0 using 12.5mm graded aggregate including necessary scafolding work for double/single storey bldgs complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 Type C-2 using 40mm graded aggregate as in plinth protection and path etc finished cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8 Type D-2 using 40mm graded aggregate as in sub base complete all as specified and directed.
M&L PVC(SWR) pipes 110mm dia single socketed, in any length with rubber ring joints,laid in trenches complete all as specified and directed.
M&L PVC(SWR) pipes 75mm dia single socketed, in any length with rubber ring joints,laid in trenches complete all as specified and directed.
M&L for 100mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for 100mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed.
Demolition of reinforced cement concrete in ground floor and paving not exceeding 15cm thickness below or above ground level including removal of same to exceeding 1 Km but not exceeding 1.5 Km complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams,lintels, chajja, cantilevers,etc complete all as specified and directed.
M&L for RCC Type B-1 (1:2:4) (using 20mm graded stone aggregate) as in Chajjas etc complete all as specified and directed.
M&L for RCC Type B-1 (1:2:4) (using 20mm graded stone aggregate) as in beams , lintels and roof beam etc. complete all as specified and directed.
S&F for TMT bars 10mm dia and over, cut to length, bent to shape required including craking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips quality conforming to IS complete all as specified and directed.
All as per item No 87 here in above but 5mm dia and over up to and including 10mm dia as in stirrups complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm in width or girth not other wise described and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc.Fe-410-W(Gde-E-250) quality-B complete all as specified and directed.
S&F in repairs Stack clamps made out of 75x 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S&F in repairs Stack clamps made out of 100 x 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
Demolation of cement concrete unreinforced on roof /terrace including plastering not exceeding 15 cm thick (below or above G.L) complete all as specified and directed.
M&L for plain cement concrete Type B-0, (1:2:4) (using 12.5 mm graded stone aggregate) in roof kerbs, mud stops, rounded or chamfered on edges complete all as specified and directed.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and directed.
Cutting grooves in brick wall, 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
M&L for water proofing treatment on roof including vertical surface with APP based polymeric membrane complete all as specified and directed as under:- (a) Screed bed 10 mm thick in cement mortar 1:3 on roof/terrace /parapet wall or concrete surfaces finish even and smooth without using extra cement with WPC @ 3% by weight of cement (b) Applying bitumenous primer @ 0.30 ltr per sq.m including cleaning roof surfaces by wire brush (c) Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg/sqm including cleaning surfaces (d) APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface of roof /terrace and parapet wall by torch application method and joint seald properly and location of drain pipe to be treated properly. Overlaping shall be 100 mm on length and width both side of APP membrane and as per manufacturers instruction (e) Applying two coat of solar reflective bitumenous aluminium paint on APP membrane fixed on roor including cleaning existing surfaces (Note: Water ponding test for 24 hours to be carried out after laying of APP membrane sheet).
S&F 75 mm bore PVC (SWR) vent cowl complete all as specified and directed.
Excavation in trenches not exc 1.5 mtr wide and not exc. 1.5 mtr deep for foundation in hard rock & getting out complete all as specified and directed.
Returning filling in trenches including spreading leveling and well ramming with water complete n.exc 25 cm thick in each layer in soft disintegrated rock complete all as specified and directed.
Removing exavated soild n.exc 50 mtr and depositing where directed at a leve n. exc 1.5 mtr above the starting point complete all as specified and directed.
Demolition and breaking up drain pipe 150 mm internal dia of pipe (salt glazed ware, AC or reinforced concrete) sat in cement mortor complete all as specified and directed.
M&L cement concrete 1:4:8 type D-2 concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in 200 mm complete all as specified and directed.
M&L 200 mm dia (internal) SGSW pipes grade ‘A’ quality laid in trenches jointed in CM 1:2 and tested after the pipes are laid jointed complete all as specified and directed
M&L PCC 1:3:6 type C-2 using 40 mm graded stone agg for concrete bed to drain pipes including , packing under and haunding against the sides of pipe, after they tested for 150 mm dia pipe.
M&L salt-glazed stoneware 150 mm dia drain pipes laid in trenchess and jointed complete all as specified and directed.
M&L precast cement concrete type B-1 (1:2:4) using 20mm graded aggregate as in cover slab, shelves, and similar work set in CM (1:4).complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in lean concrete for foundation in drain,manholes etc all as specified and directed.
M&L for on site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent Shaft, connection etc, complete for 20 users with UPFLOW FILTER INCLUDING MEDIA complete all as specified and directed.
M&L for Soakage wells of size 1.8 M dia X 3.0 M effective depth including necessary excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as specified and directed.
Taking down carefully copper/aluminium point wiring any type ,surface/concealed/ PVC capping or tubing ( including light,fan,s/socket, or power)complete including fixtures and fittings such as switches,ceiling rose,pendents,regulators,sockets etc complete all as specified and directed.
Taking down old unserviceable main switch board, DB of any type and capacity from its location with accessories MCCB's/MCB SP/SPN/TPN complete all as specified and directed.
Taking down old unserviceable tube light/cfl light/recessed mouted light or any type of light fittings complete all as specified and directed.
Taking down old unserviceable surface/air mounting fixed cable any capacity & refixing of cable any size any cap upto 70sqmm fixed on wall/trench with clamps & saddle properly complete all as specified and directed.
M &L for PVC concealed conduit point wiring with 1.5 square mm nominal area stranded copper conductor PVC insulated single core cable1100 Volts grade conforming to IS694 part-i draw in 20 mm size PVC conduit in concealed including 600volts grade 1.5square mm copper stranded single core cable green color PVC insulated for continuous earthing wire with complete chesscutting ,S/F of 20 mm dia PVC conduit with elbow,bends,couplers,tee, sunken boxes pressed steel boxes made out of not less than 1.6 mm thick sheet mounting fitting/junction boxes et. covered with 2.8 mm thick white laminated bakelite sheet (ISI marked), including painting outer side with one coat of bitumenus paint and inside a coat of red oxide primer covered the conduit with cement mortor after drawing of electric cables and making good of distrubed surfaces and match with existing shade of wall/roof complete all as specified and directed.
One light/exhaust fan point controlled by one switch complete all as specified and directed.
One three pin 5 Amps switch socket outlet on independent board complete all as specified and directed.
S&F switch piano, flush type single pole,5 Amps, 240 Volts Ac complete all as specified and directed.
S&F ceiling rose surface backlite, 65x50mm, three terminals, 5 Amps,240 Volts AC complete all as specified and directed.
S&F switch socket combination 3 Pin,5 Amps,240 Volts, flush type complete all as specified and directed.
S & Laying concealed sub main wiring with two single core cable of 6 sqmm PVC insulated , 1100 volt grade as per IS 694, with multistranded copper conductor in and including rigid PVC conduit (ISI Marked) including earthing wire of pvc insulated stranded 6 sq mm cable ,chess cutting including S/F of 20 mm dia PVC conduit with elbow,bends,couplers,tee, sucken boxes pressed steel box mounting fitting/junction boxes etc covered the conduit with cement mortor after drawing of electric cables and makig good of distrubed surfaces and match with existing shade of wall/roof including taking down old unserviceable sub main wiring any type any capacity including conduits complete all as specified and directed.
Supply and fix LED tube light fitting capacity 20 watt fixed on wall/surface / ceiling with all accessories tube,driver,with surge protector completerewired with multistranded copper cable & connecting to ceiling rose with 3 core ,multistranded flexible copper cableMake CGCta No-LDL-20-NW/wipro/CG/Havells/philips/Bajaj complete all as specified and directed.
Supply and fix LED light fitting mirror type with high output diffuser 2 feet capacity 10 watt fixed on wall/surface / ceiling with all accessories tube,driver,with surge protector completerewired with multistranded copper cable & connecting to ceiling rose with 3 core ,multistranded flexible copper cableMake CGCta No-LDL-20-NW/wipro/CG/Havells/philips/Bajaj complete all as specified and directed.
S & F 35 Watt LED Bldg security light with a nominal system l The luminaire shall have rated system lifetime of 50,000 burning hours at L70. The luminaire should have cool white colour temperature (CCT>5000K) and a CRI>70. The luminaire shall meet IP66 rating with THD<20% & pf>0.9. The luminaire housing should be made of pressure die cast aluminimum. The total power consumption should not exceed 25W (including driver) pre wired fitted on and including two Nos PVC block of suitable l size and connection up to tube light fitting with connecting up with copper 3 core flexible cord of minimum size 0.5 Sqmm size and testing complete including LED lamp, complete all as specified and as directed. Make : CG CAT No.LST-20-CDL-M or equivalent in , Wipro, Bajaj, Philips complete all as specified and directed.
S&F Sheet metal enclosure for 04 ways MCB DBs SPN 240 volts, single door type powder coated with 200 Amps rated bus bar, neutral link, earth rail & din rail, ISI marked including fixing of MCBs, Isolators, RCOBs, RCCBs, ELCBs, etc, complete all as specified and directed .
S & F MCBs of capacities SPN 32 Amp 240/415 volt complete all as specified and directed.
S & F MCBs of capacities SP 06 Amp 240 volt complete all as specified and directed.
karambir constructions
SRI JD CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .