| 1 | L1₹52.6 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹52.7 L+₹13,172.62 (0.25%)Admitted-Finance 257 KAILASH HILLS EAST OF KAILASH NEW DELHI 110065 | NEW DELHI | NEW DELHI | DELHI | 110065 | L2 | Admitted-Finance | |
| 3 | L3₹53.1 L+₹46,470.02 (0.88%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹57.3 L+₹4.6 L (8.84%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹68.5 L+₹15.9 L (30.1%)Admitted-Finance RZ 151 BLOCK Y NEW ROSHANPURA PAPRAWAT ROAD NAJAFGARH SOUTH WEST DELHI DELHI 110043 | WEST DELHI | DELHI | 110043 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | RAKESH DUTT SHARMA & SONS L1 | M/s. Leonine Constructions L3 | MODERN CONCEPT CONSTRUCTIONS L5 | AMRIT LAL BEHL AND SONS L2 | M/s S.K.Industries L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | 1) Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m- All kinds of soil. | 26.86 | Cum | 193 ₹5,183.98 | 250 ₹6,715 | 250 ₹6,715 | 150 ₹4,029 Lowest | 225 ₹6,043.5 |
| 2.00 | 2) Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 40.18 | cum | 147 ₹5,906.46 | 100 ₹4,018 Lowest | 210 ₹8,437.8 | 100 ₹4,018 Lowest | 150 ₹6,027 |
| 3.00 | 3) Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | 20.09 | Cum | 1,470 ₹29,532.3 Lowest | 1,700 ₹34,153 | 1,950 ₹39,175.5 | 1,500 ₹30,135 | 1,625 ₹32,646.25 |
| 4.00 | 4) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) | 4.06 | Cum | 4,800 ₹19,488 | 5,000 ₹20,300 | 6,000 ₹24,360 | 4,000 ₹16,240 Lowest | 5,200 ₹21,112 |
| 5.005) Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: | ||||||||
| 6.00 | 5.1) 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). | 11.7 | Cum | 7,500 ₹87,750 | 6,500 ₹76,050 | 8,500 ₹99,450 | 5,500 ₹64,350 Lowest | 6,800 ₹79,560 |
| 7.00 | 6) Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns | 81.93 | Sqm | 280 ₹22,940.4 | 200 ₹16,386 Lowest | 300 ₹24,579 | 200 ₹16,386 Lowest | 240 ₹19,663.2 |
| 8.007) Providing and laying in position ready mixed plain cement concrete, using fly ash and cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. | ||||||||
| 9.007.1) All works upto plinth level: | ||||||||
| 10.00 | 7.1.1) M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) | 20.25 | Cum | 7,050 ₹1,42,762.5 | 5,500 ₹1,11,375 Lowest | 8,200 ₹1,66,050 | 5,500 ₹1,11,375 Lowest | 6,500 ₹1,31,625 |
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
12 Aug 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
EE(CD-III), East Campus Maintenance (Residential Area Maintenance) , IIT D.
Name of work- Construction of temporary faculty room between block V and VI in academic area at IIT Delhi. Sub Head - Civil and Electrical Work
2020_IIT_575370_1
IITD/ WORKS(SP-3097)/2020
Open Tender
Civil Works
Works
180 days
IIT Delhi, Hauz Khas, New Delhi
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
Registrar IIT Delhi
₹1.4 L
27 Aug 2020
4 Aug 2020
13 Aug 2020
4 Aug 2020
12 Aug 2020
4 Aug 2020
90 days
Amount
1) Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m- All kinds of soil.
2) Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
3) Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
4) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
5) Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:
5.1) 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
6) Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns
7) Providing and laying in position ready mixed plain cement concrete, using fly ash and cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.
7.1) All works upto plinth level:
7.1.1) M-10 grade plain cement concrete (cement content considered @ 220 kg/cum)
8) Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
9) Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 12 mm mild steel U beading
10) Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
11) Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm
12) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
13) Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
14) Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
14.1) Twin rubber stopper
15) Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick
16) Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
16.1) Hot finished welded type tubes
17) Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
18) Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm
19) Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown,Cat Eye or equivalent.
20) Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
21) Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
21.1) Ridges plain (500 - 600mm)
21.2) Gutter (600 mm over all girth)
22) Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and
size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
23) Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183, having density 48 kg/m3,50 mm thick,wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing GI wire etc. complete as per directions of Engineer-inCharge.
24) 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
25) Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
25.1) New work (two or more coats) over and including water thinnable priming coat with cement primer
26) New work (two or more coats) over and including water thinnable priming coat with cement primer
27) Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
27.1) In cement mortar
28) Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
29) Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
29.1) For fixed portion
29.1.1) Powder coated aluminium (minimum thickness of powder coating 50 micron)
30) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
30.1) Powder coated aluminium (minimum thickness of powder coating 50 micron)
31) Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
31.1) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
32) Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete
32.1) Upto 5mm depth and 5 mm width
33) Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineerin-charge complete.
34) Providing & Fixing of stainless steel cylindrical lock with a pair of handles (Dorset - Model No. CETO) all complete as per direction of engineer-in-charge.
35) Providing and fixing factory made hot pressed both side laminated flush door ready made shutter with one mm thick decorative laminate on both side confirming to IS:2202 (Part) non decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veeneering with vertical grain or cross bands and face veneer on both face of shutters. 35mm thick including ISI marked stainless steel butt hinges with necessary screws.
35.1) 35mm thick including ISI marked stainless steel butt hinges with necessary screws.
36) Providing and fixing 10 mm thick non - asbestos multipurpose cement board rainforced with cellulose fiber manufactured through autoclaving process ( high pressure steam cured ) as per IS:14862 of Everest industries Ltd or equivalent make , over the exidting MS frame work ( to be paid in basic items ) with 25 mm counter sunk ribbed hard screws @200m center to center.
37) Providing and fixing 50 mm thick sandwich roof puff panel (factory made only) as per specification as follow. A) trapezoidal steel sheet having minimum 30mm crest depth, polyester top coat & alkyd backer. Zinc coating shall be 120g/sqm as per IS-277. Top coat polyester 15-18 microns over 5-7 micron epoxy primer. b) Insulation: High density puff insulation. c) Inner sheet: Colour coated galvanized slightly ribbed. Thickness 0.50mm (TCT) minimum 15-18 micron top coat polester coation, zinc coating 120g/sqm as per IS-277
38) Providing and fixing 18 mm thick WPC (wooden polymer composit) board inside shelves, sides, back portion or in drawer units etc. for specific size and 18 mm thickness, composed of wood dust (min 30% - 40% and remaining PVC, fungus/Acid/termite/water proof , fire retardent, formaldehyde free, virgin thermoplastic,single Extruded and screw-able/nail-able, having density of 680 - 720 kg/cum. and water absorption up to 1 % with approved make with necessary fixing arrangement and as per requirement complete as per direction of Engineer in charge.
39) Providing and fixing 6 mm thick WPC (wooden polymer composit) board for back portion of cupboard for specific size and 6 mm thickness, composed of wood dust (min 30% - 40% and remaining PVC, fungus/Acid/termite/water proof , fire retardent, formaldehyde free, virgin thermoplastic,single Extruded and screw-able/nail-able, having density of 680 - 720 kg/cum. and water absorption up to 1 % with approved make with necessary fixing arrangement and as per requirement complete as per direction of Engineer in charge.
40) Providing and fixing roller blinds, the febric should be screen openness of 5% and composition of 75% PVC 25% polyster with fabric weight of 465 GSM with fire resistance grade of NSPA 701, BS 586 part- II with anodized aluminium channel weight, bracket and hangers etc. the fabric will be approved colour and shed of approved manufacturer complete. Make (VISTA/MAC/Marvel
41) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
41.1) Group-C
42) Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
43) Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
44) Supplying and fixing of 25 mm of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
45) Supplying and drawing of 3 x 4 sqmm FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
46) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
46.1) 15/16 A Switch
46.2) 6 pin 15/16 A socket outlet
46.3) Telephone socket outlet
47) Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
47.1) 1 or 2 Module (75mmX75mm)
47.2) 12 Module (200mmX150mm)
48) Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
49) Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
50) Supply and installation of recess/surface mounting LED luminaire equipped with CRCA powder coating housing, anti glare polycarbonate diffuser with energy efficient electronic driver with following features:- Suitaible for operating voltage and frequency: 130-300 V AC, 50 Hz; wattage not more then 36 Watts, Output lumens not less then 3300lm; CCT not less then 6500K; Dimension in mm (595x595); Normal surge protection 2.5kV; Powe factor not less then 0.9; Minimum IP protection 20.
51) Supply and installation of recess/surface mounting round/square LED luminaire equipped with CRCA powder coating housing, anti glare polycarbonate diffuser with energy efficient electronic driver with following features:- Suitaible for operating voltage and frequency: 130-300 V AC, 50 Hz; wattage not more then 12 Watts, Output lumens not less then 650lm; CCT not less then 5700K; slim profile surface mounted down light square/round type; Normal surge protection 2.5kV; Powe factor not less then 0.9; Minimum IP protection 20.
52) Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
53) Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
54) Supplying, Installation, testing & commissioning of energy efficient LED compound light equipped with power coated PDC alluminium body & secondry optical lens for superior light distribution with energy efficient electronic driver with following features:- 130-300 Vac, 50Hz, wattage not more then 30 Watts, efficancy not less then 110 Lm/W, CCT 5700K, Nominal surge protection 2.5 kV, Power factor not less then 0.9, Minimum IP protection 66 etc. in suitable size GI pipe with reducer, GI saddle, bracket for proper fixing as required.
55) Supplying and fixing of 40 mm dia medium G.I. pipe of 1.5 meter long L type on surface of wall fitted with GI/MS bracket with reducer etc. complete as required.
56) Supply, Installation, Testing and Commissioning of 140 mm x 140 mm x 95 mm sixe FRPVC cable connection box complete with stud type connector, fixing on wall/ GI pole with 2 nos. suitable size MS clamp including connections, testing etc. as required.
57) Supplying and Laying of PVC insulated, PVC sheathed XLPE aluminum conductor armored cable of 3 x 6 sqmm size, 1.1 kV grade, on wall surface etc. as required.
58) Supplying and making end termination with brass compression gland and aluminium lugs for 3 X 6 sq. mm of PVC insulated and PVC sheathed copper conductor cable of 1.1 KV grade as required.
59) Supply and Installation of 250 mm sweep suitable for operation on 230V, 50 Hz, AC supply exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
60) Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
61) Providing and fixing 100 A,30KA,FP MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
62) Supplying and fixing of 12 way (4 + 36), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required. (DB Should have provision for installing four pole MCCB as incomer)
63) Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63.1) Single Pole
63.2) Double Pole
64) Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
65) Supplying and fixing Cable End Box (Loose Wire Box) suitable for 12/8 way, Double door TPN, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
66) Supply and fixing of 1X16 sq. mm FRLS PVC insulated flixible copper conductor single core cable from LT distribution panel to vertical TPDB in flixible PVC pipe.
67) Supplying and making end termination with brass compression gland and copper lugs for 4 X 16 sq. mm (28mm) of PVC insulated and PVC sheathed copper conductor cable of 1.1 KV grade as required.
68) Supplying and installing of 100 mm width X 50 mm depth X 1.6 mm thickness perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
69) Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
70) Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
71) Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
72) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
73) Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
74) Supplying and Laying of one number 3.5 Core Aluminium, PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 35 sq. mm size in the existing masonry open duct as required.
75) Supply and installation of SS enclosure for housing incomming MCCB 4P, of appropiate size with incomming and outgoing opening, suitable to accommodate upto 70sqmm, 3.5 core aluminium armoured cable,with louvers for heat dissipation and mounting hole for easy wall mounting.
76) Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
77) Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
77.1) 1 run of cable
77.2) 2 run of cable
77.3) 3 run of cable
FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)
78) Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
79) Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
80) Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.
81) Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
83) Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
AMRIT LAL BEHL AND SONS
M/s. Leonine Constructions
M/s S.K.Industries
MODERN CONCEPT CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .