Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹10 L
Closing Date
31 Jul 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
PR & CC
Digitally signed and encrypted bids under two bid systems are invited for Construction of Compound Wall
20000192-HD-10120
20000192-HD-10120
Open Tender
Two Bid
Budaun, Uttar Pradesh
₹0
₹10 L
31 Jul 2020
15 Jul 2020
31 Jul 2020
31 Jul 2020
15 Jul 2020 - 20 Jul 2020
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | Earthwork in excavation | Earthwork in excavation — EXCAVATION AND BACK-FILLING WITH DISPOSAL INSIDE, EXCAVATE THE SOIL, AS PER THE REQUIREMENT OR AS ADVISED BY ENGINEER IN CHARGE HPCL. TRANSPORT THE EXCAVATED SOIL TO A DESIGNATED LOCATION (CLOSE TO THE JOB EXECUTION SITE, AS ADVISED BY THE HPCL SUPERVISOR) AND BRING IT BACK FOR BACKFILLING. ALSO, CLEAR THE PIPELINE OF ANY SOIL, MUD, ETC. FOR INSPECTION PURPOSE. BARRICADE THE EXCAVATED TRENCH FROM ALL SIDES, USING METALLIC SCAFFOLDING PIPES. SCAFFOLDING MADE FOR BARRICADING WILL BE PAID SEPARATELY AS PER THE PO LINE. SUPPLY OF SCAFFOLDING PIPES REQUIRED FOR BARRICADING WILL BE IN VENDOR''S SCOPE. BACKFILL THE TRENCH, AFTER COMPLETION OF JOBS AND OBTAINING CLEARANCE FROM THE CONCERNED ENGINEER OF HPCL. CARRY OUT PROPER RAMMING IN ORDER TO COMPACT AND LEVEL TOP SURFACE OF THE EXCAVATED AREAS PROPERLY. EXCESS EARTH TO BE TRANSPORTED TO THE PLACE INSIDE THE PLANT AS ADVISED BY ENGINEER IN CHARGE HPCL. PAYMENT WILL BE MADE ON PER M3 BASIS OF EXCAVATED VOLUME. THIS LINE ITEM WOULD BE APPLICABLE ONLY IN CASE OF PLANNED UNIT SHUT DOWN(S/D) PERIOD. CONCERNED EIC WILL CERTIFY THE PLANNED S/D OF THE UNIT FOR THE PURPOSE OF APPLICABILITY OF THE S/D RATE. | - | Cubic Meters |
| 2 | PLAIN CEMENT CONCRETE | PLAIN CEMENT CONCRETE — SCOPE OF JOB INCLUDES PROVIDING AND LAYING PLAIN CEMENT CONCRETE AT ALL DEPTHS/HEIGHTS. THE CONCRETE GRADE SHALL BE 1:2:4 (CEMENT: SAND: COARSE AGGREGATE) BY VOLUME. JOB INCLUDES SUPPLY OF CEMENT, SAND, AGGREGATE, WATER, PROVISION FOR TEMPORARY SIDE SHUTTERING, RAMMING, TAMPING, VIBRATION, SUPPLY OF MANPOWER, TOOLS, TACKLES, CURING FOR THE PERIOD OF SIX DAYS ETC. JOB SHALL BE COMPLETED AS PER INSTRUCTION OF SITE ENGINEER. RATES QUOTED SHALL BE INCLUSIVE OF THE SAME. | - | Cubic Meters |
| 3 | PCC 1:2:4 | PCC 1:2:4 — PROVIDING AND LAYING PCC 1:2:4 USING 20 MM AND DOWN SIZE GRADED STONE AGGREGATES INCLUDING MIXING, PROVIDING FORMWORK IF REQUIRED, PLACING, COMPACTING BY HAND RAMMING, CURING ETC COMPLETE FOR DPC/COPING/GROUTING/FOOTING BASE AND OTHER JOBS. | - | Cubic Meters |
| 4 | RUBBLE SOLING | RUBBLE SOLING — PROVIDING AND LAYING RUBBLE SOLING OF REQUIRED THICKNESS INCLUDING HAND PACKING, FILLING THE INTERSTICES WITH CHIPS, SPALLS AND BINDING WITH GRIT/STONE DUST/MURRUM/USABLE SOIL AND WATERING, COMPACTING BY HAND RAMMING. | - | Cubic Meters |
| 5 | RCC M25 | RCC M25 — RCC 1:1.5:3:PROVIDING AND LAYING IN POSITION MACHINE BATCHED AND MACHINE MIXED RCC WITH 1(CEMENT):1.5(FINE AGGREGATE):3(COARSE AGGREGATE) RATIO OR READY MIXED MINIMUM M-20 GRADE CONCRETE FOR REINFORCED CEMENT CONCRETE WORK, USING CEMENT CONTENT AS PER APPROVED DESIGN MIX, MANUFACTURED IN FULLY AUTOMATIC BATCHING PLANT AND TRANSPORTED TO SITE OF WORK IN TRANSIT MIXER FOR ALL LEADS, HAVING CONTINUOUS AGITATED MIXER, MANUFACTURED AS PER MIX DESIGN OF SPECIFIED GRADE FOR REINFORCED CEMENT CONCRETE WORK, INCLUDING PUMPING OF R.M.C AS APPLICABLE, CENTERING, SHUTTERING, COST OF ADMIXTURES IN RECOMMENDED PROPORTIONS AS PER IS: 9103 TO ACCELERATE/RETARD SETTING OF CONCRETE, IMPROVE WORKABILITY WITHOUT IMPAIRING STRENGTH AND DURABILITY BUT EXCLUDING COST OF REINFORCEMENT AS PER DIRECTION OF ENGINEER-IN- CHARGE. MECHANICAL MIXERS WITH HOPPER ALONG WITH WEIGH BATCHER SHALL ALSO BE PERMITTED FOR USE AT SITE WITH THE APPROVAL OF ENGINEER-IN CHARGE TO PRODUCE DESIGN MIX CONCRETE OF M-20 GRADE. NOTE: RATE TO INCLUDE COST OF ALL LABOUR, TOOLS, TACKLES, EQUIPMENT, HIRE CHARGES, SUPPLY OF ALL MATERIALS (EXCEPT REINFORCEMENT) SUCH AS, MINIMUM 43 GRADE OPC CEMENT INCLUDING SULPHATE RESISTANT CEMENT FOR SUB-STRUCTURES IF REQUIRED, COARSE AND FINE AGGREGATES, ADMIXTURES, SHUTTERING AND OTHER MINOR CONSTRUCTION MATERIALS, TESTING OF CONCRETE, CURING ETC. WITH ALL BYE WORKS AND SUNDRY WORKS COMPLETE. | - | Cubic Meters |
| 6 | REINFORCEMENT STEEL | REINFORCEMENT STEEL — SUPPLY, FABRICATION AND LAYING IN POSITION STEEL REINFORCEMENT CONFORMING TO IS:1786 AT ALL DEPTHS INCLUDING CUTTING, COLD BENDING, TYING AND PLACING IN POSITION THE RODS, WITH NECESSARY 18 SWG BLACK ANNEALED BINDING WIRE INCLUDING COST OF BINDING WIRE AND ANY OTHER INCIDENTAL CHARGES ETC. COMPLETE AS PER STANDARD SPECIFICATION. LAPS, CHAIRS AND SPACER BARS SHALL NOT BE CONSIDERED FOR MEASUREMENT AND PAYMENT. THE JOB TO BE EXECUTED AS PER ATTACHED TECHNICAL SPECIFICATIONS, JOB PROCEDURES ETC COMPLETE AND AS DIRECTED BY HPCL EIC. | - | Metric Ton |
| 7 | Brick Masonry (CM 1:4) | Brick Masonry (CM 1:4) — SUPPLY AND CONSTRUCTING BRICK MASONRY IN CM 1:4 USING BRICKS OF MINIMUM COMPRESSIVE STRENGTH 50 KG/SQ.CM AND CONFORMING TO IS:1077-1986 INCLUDING PROVIDING ALL OPENINGS AND PROJECTIONS AS PER THE DRAWING, RAKING THE JOINTS TO 1 CM DEEP, SCAFFOLDING, SOAKING OF BRICKS PRIOR TO USE AND CURING ETC COMPLETE AS PER SPECIFICATIONS. MEASUREMENT OF MASONRY WILL BE BASED ON ACTUAL THICKNESS OF WALL CONSTRUCTED. (A) BRICK FOR MASONRY IN FOUNDATION, WALLS AND OTHER LOCATION SHALL BE HAND OR MACHINE MOULDED AND MADE FROM SUITABLE SOIL AND KILN BURNT. THEY SHALL HAVE REGULAR AND UNIFORM SIZE AND COLOUR, SHARP STRAIGHT AND RIGHT ANGELED EDGES AND DEEP CHERRY RED COLOUR, UNIFORMITY WELL BURNT THROUGHOUT BUT NOT OVER BURNT. THEY SHALL HAVE SMOOTH RECTANGULAR FACES WITH PALLET SIDES AND SHARP CORNERS. GENERALLY THEY SHALL CONFIRM TO IS:1077. (B)THEY SHALL BE FREE FROM CRACKS, FLAWS AND NODULES OF FREE TIME. (C)THEY SHALL BE MOULDED WITH THE FROG OF 100 X 40MM AND 10 TO 20 MM DEEP ON ONE OF ITS FLAT SIDES. (D) THEY SHALL GIVE A CLEAR METALLIC RINGING SOUND WHEN STRUCK BY A MALLET AND SHALL NOT BREAK WHEN DROPPED ON THE GROUND ON THEIR FLAT FACE IN A SATURATED CONDITION FROM THE HEIGHT OF 600MM. (E) THEY SHALL SHOW A FINE-GRAINED, UNIFORM, HOMOGENEOUS AND DENSE TEXTURE ON FRACTURE AND SHALL BE FREE FROM LUMPS OF LIME, LAMINATION, CRACKS, AIR HOLES, SOLUBLE SALTS CAUSING EFFLORESCENCE OR ANY OTHER DEFECTS WHICH MAY IMPAIR THEIR STRENGTH, DURABILITY, APPEARANCE AND USEFULNESS FOR THE PURPOSE INTENDED. THEY SHALL NOT HAVE ANY PART UNDER-BURNT. (F)THE SIZE OF THE CONVENTIONAL BRICKS SHALL BE 225X110X75MM. ONLY BRICKS OF ONE STANDARD SIZE SHALL BE USED IN ONE WORK UNLESS SPECIALLY PERMITTED BY THE CLIENT/CONSULTANT. THE FOLLOWING TOLERANCES ARE PERMITTED IN THE STANDARD CONVENTIONAL SIZE ADOPTED ON THE PARTICULAR WORK. (G) AFTER IMMERSION IN COLD WATER FOR 24 HOURS, ABSORPTION BY WEIGHT SHALL NOT EXCEED 15% OF THE DRY WEIGHT AS PER IS:3495 (PART-2) | - | Cubic Meters |
| 8 | EXT. SAND FACE FINISH | EXT. SAND FACE FINISH — PROVIDING AND APPLYING PLASTER TO WALL WITH 15 MM THICK CEMENT MORTAR 1:4 (1 CEMENT:4 COARSE SAND) ON EXTERNAL SURFACE WITH FINISHED SMOOTH, INCLUDING SCAFFOLDING, CURING, ETC. UPTO 10 M HEIGHT FROM GROUND LEVEL, ALL COMPLETE AS PER SPECIFICATION AND DIRECTION OF ENGINEER-IN-CHARGE. | - | Square Meters |
| 9 | EXTERNAL PAINTING | EXTERNAL PAINTING — PROVIDING AND APPLYING WATERPROOF CEMENT PAINT OF APPROVED MAKE AND SHADE WITH TEXTURED FINISH IN TWO COATS AT ALL LOCATIONS OVER AND INCLUDING A PRIMING COAT OVER WALL SURFACE, ETC., INCLUDING PREPARATION OF SURFACE COMPLETE WITH ALL BYE WORKS, SPECIFICATION AND DIRECTION OF THE ENGINEER.(ALL BUILDINGS EXCEPT ADMINISTRATION BUILDING) | - | Square Meters |
| 10 | Structural Steel | Structural Steel — SUPPLYING, STRUCTURAL STEEL WORK WITH STRUCTURAL/ TUBES OR APPROVED EQUIVALENT TUBULAR STEEL AND PIPES CONFIRMING TO IS 1161 FOR COLUMNS, PORTALS, BRACINGS, TRUSSES, PURLOINS, RAFTERS, ETC. INCLUDING GUSSET PLATES, HOLDING DOWN BOLTS, ANCHOR PLATES ETC, INCLUDING SITE AND SHOP FASTENERS, BOLTING, WELDING AT SHOP OR WORK SITE AT ALL HEIGHTS ETC. COMPLETE. NOTE: THE WEIGHT OF STEEL WORK FOR THE SAKE OF PAYMENT SHALL BE CALCULATED BY LINEAR MEASUREMENTS AND UNIT WEIGHTS TAKEN FROM THE RELEVANT BIS CODE, STANDARD STEEL TABLE BASED ON APPROVED STRUCTURAL DRAWINGS WITHOUT MAKING ANY DEDUCTIONS FOR HOLES, BEVEL ENDS, OR EDGE BEVELING OF PLATES. GUSSET PLATES SHALL BE PAID FOR THE MINIMUM RECTANGLE ENVELOPING THEIR ACTUAL PERIPHERY. PACKING CUT PIECES OF PLATES ETC. PROVIDED IN THE BASE PLATE OF COLUMN FOR LEVELING ETC. SHALL NOT BE MEASURED AND PAID SEPARATELY. STRUCTURAL, FABRICATION DRAWING TO BE SUBMITTED BY THE CONTRACTOR FOR APPROVAL OF CONSULTANT/ENGINEER IN-CHARGE. | - | Metric Ton |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
20000192-HD-10120.pdf
TENDER_DOCUMENT • 39.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .