Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹13.3 L+₹1.1 L (9.03%)Rejected-AOC B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-AOC L2 BIDDER |
Tender Value
₹14.8 L
EMD Value
₹29,600
Closing Date
10 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Amla
GE AF Amla, Betul Dist 460553 (MP)
REPAIR/ MAINTENANCE OF COOLING APPLIANCES AT AFS AMLA
2020_MES_345178_1
8369/E8 of 2020-21
Open Tender
Civil Works
Item Rate
270 days
GE AF Amla
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Amla
₹29,600
Yes
3 Oct 2020
15 May 2020
13 Jun 2020
15 May 2020
10 Jun 2020
22 May 2020
60 days
Amount
Taking down carefully Split AC/ Window AC of capacity 1 to 2 TR from any position, any condition from site after disconnecting electrical connection, pipe line etc.; making good the disturbed surface in cement mortar 1:4 (or) PCC 1:2:4; including transporting it to civil work shop for repairing/ overhauling/ servicing/ replacing unserviceable spare parts and shifting back to the location as directed by Engineer-in-Charge after repair complete all as specified and directed. Note:- (i) Cost of spare parts replaced/ refringent gas refilling shall be measured and paid separately as supply only under relevant items herein after. (ii) AC repaired at civil workshop to be get tested by the contractor before shifting back to the department. (iii) Labour charges for replacement of spares parts if any required during servicing of AC’s deemed to be included in the quoted rate.
Re-fixing split AC/ Window AC of capacity 1 to 2 TR in the same location (or) any other location as directed by Engineer-in-Charge including necessary civil works and electrical work such as grouting, cutting, brazing, connecting up, testing etc., complete all as specified and directed. Note:- (i) Test Report shall be submitted by the contractor after testing. (ii) Cost of minor spare parts such as flairnut, bolt etc., required for fixing shall be measured and paid separately as supply only under relevant items herein after.
Repair/ Servicing of Air Conditioner Window type of capacities 1.5 to 2.0 TR in existing location by dismantling the panel and component parts such as fan motor, blower, housing, filters etc., for cleaning and replacing worn out/ damaged parts including reassembling, connecting up and testing complete all as specified and directed.
Repair/ Servicing of Air Conditioner Split type of capacities 1.5 to 2.0 TR in existing location by dismantling the internal & external units and component parts such as fan motor, blower, housing, filters etc., for cleaning and replacing worn out/ damaged parts including reassembling, connecting up and testing complete all as specified and directed. Notes for item no 3 & 4 of above: - (i) Cost of spare parts replaced shall be measured and paid separately as supply only under relevant items herein after. (ii) Cost of refringent gas refilled shall be measured paid separately under relevant items herein after (iii) Labour charges for replacement of spares parts if any required during servicing of AC’s deemed to be included in the quoted rate. (iv) Any break down of AC’s will be attended by the contractor within 24 hrs on receipt of complaints from MES through telephonic/written message. (v) Test Report shall be submitted by the contractor after testing.
Supply and fixing in repair Indoor Unit 1.5 TR for Split AC comprising of the following Specification including taking down old unserviceable unit and depositing it to AGE E/M store yard, provision of drain pipe, connecting up etc., and testing complete all as specified and directed: - Specification of 1.5 TR Split AC Indoor unit only. (i) AC - 18K AUS-18C53F120D (ii) Nominal Capacity: 18K; Power supply: 1Ph- 220~240V- 50Hz; Indoor air flow (Turbo): 850/700/650 m3/h; Indoor noise level (Turbo/Hi/Mi/Lo): 43/40/37dB(A) (iii) Indoor fan motor: Model - YFNPG25-4, Ouput - 25 W, Speed (Turbo/Hi/Mi/Lo) - 1300/1150/1000 r/min
Supply and fixing in repair Indoor Unit 2.0 TR for Split AC comprising of the following Specification including taking down old unserviceable unit and depositing it to AGE E/M store yard, provision of drain pipe, connecting up etc., and testing complete all as specified and directed: - Specification of 2.0 TR Split AC Indoor unit only. (i) AC - 24K AUS-24C53F230G (ii) Nominal Capacity: 24K; Power supply: 208-240V; Indoor air flow (Turbo): 1100/980/880 m3/h; Indoor noise level (Turbo/Hi/Mi/Lo): 50/46/43 dB(A) (iii) Indoor fan motor: Model - GAL4P40A-KND, Ouput - 40 W, Speed (Turbo/Hi/Mi/Lo) - 1270/1150/1050 r/min
Supply only following spares required for replacement during the process of servicing/ repairing/ refixing of the AC’s 1.5 to 2 TR:-
Cooling coil filter set for Split A/C (1.5 to 2 ton) with necessary accessories
Fan blade for Window AC 1.5/ 2.0 ton
Capacitor of 2.5 mFD capacity suitable for Indoor blower motor of Split AC
Starting Capacitor 100/ 120 MFD 275 Volts 50 Hz
Starting capacitor 80/ 100 MFD 275 Volts 50 Hz
Running capacitor 45 MFD 440 Volts, 50 Hz
Running capacitor 36 MFD 440 Volts, 50 Hz
Dual Capacitor Starting & running 45/ 50 MFD capacity 25 / 085 / 21 MPP SH
Capacitor for Condensing Fan Motor 4 MFD
Capacitor for Condensing Fan Motor 6 MFD
Starting Relay 4/ 5 pin suitable for AC's 1.5 ton to 2.0 ton capacity.
ON/ OFF Knob 3/ 4 way
Thermostat with knob suitable for Window AC 1.5 to 2 TR
Filter Drier 1/4" x 1/4"
FR PVC Insulated Copper flexible cable 3 core 4 Sqmm 1100 Volts
3- way Bakelite connector of capacity 20 Amps
Brass flairnut of size 5/8 and 3/8 suitable for fixing Split AC
Brass dead nuts of size 1/4"
Brass flair nuts of size 1/4"
Supply and fix in repairs thermostat with knob for Window AC 1.5 to 2 TR with necessary accessories including taking down old unserviceable motor, connecting up, testing etc., complete all as specified and directed
Supply and fix in repairs swing motor for Split AC (1.5 to 2 ton) with necessary accessories including taking down old unserviceable motor, connecting up, testing etc., complete all as specified and directed.
Supply and fix in repairs fan Motor suitable for outdoor unit of Split AC 1.5/2 TR including taking down old unserviceable motor, connecting up, testing etc., complete all as specified and directed.
Supply and fix in repairs double ended fan motor for Window AC 1.5 ton with capacity 1/10 HP including taking down old unserviceable motor, connecting up, testing etc., complete all as specified and directed.
Supply and fix in repairs double ended fan motor for Window AC 2 ton with capacity 1/8 HP including taking down old unserviceable motor, connecting up, testing etc., complete all as specified and directed.
Supply and fix in repairs copper condensor coil set suitable for split/ window AC 1.5 ton with necessary brazing etc., and other accessories as required complete including taking down old unserviceable one, connecting up, testing etc., complete all as specified and directed.
Supply and fix in repairs Copper Condensor coil set suitable for split/window AC 2.0 ton with necessary brazing etc., and other accessories as required including taking down old unserviceable one, connecting up, testing etc., complete all as specified and directed.
Supply and fix in repairs multi PCB with display sensorboard including temperature sensor and wireless remote including taking down old unserviceable one, connecting up, testing etc., complete all as specified and directed.
Supply and fix in repairs PCB along with control relay and suitable for split window type AC's including taking down old unserviceable one, connecting up, testing etc., complete all as specified and directed.
Supply and fix in repairs indoor blower motor for 1.5 ton Split AC with necessary accessories including taking down old unserviceable one, connecting up, testing etc., complete all as specified and directed.
Supply and fix in repairs indoor blower motor for 2.0 ton Split AC with necessary accessories including taking down old unserviceable one, connecting up, testing etc., complete all as specified and directed.
Supply and fix in repairs Rotary Compressor Sealed Unit for split Air Conditioner of capacity 2.0 TR including taking down old unserviceable one, connecting up, testing etc., complete all as specified and directed.
Supply and fix in repairs Reciprocating Compressor Sealed Unit for window / split Air Conditioner of capacity 2.0 TR including taking down old unserviceable one, connecting up, testing etc., complete all as specified and directed.
Supply and fix in repairs Reciprocating Compressor Sealed Unit for window / split Air Conditioner of capacity 1.5 TR including taking down old unserviceable one, connecting up, testing etc., complete all as specified and directed.
Supply and fix in repairs copper refrigerant pipe of following sizes suitable for AC’s including necessary bending work as required to form a shape at site, gas welding etc., and testing complete all as specified and directed. Note: The wall thickeness and type of copper tube supplied by the contractor should conform to relevent IS standard.
Bore dia 1/4"
Bore dia 3/8"
Bore dia 1/2"
Bore dia 5/8"
Supply and fix in repairs 3mm thick thermo form black colour sheet insulation suitable for refrigerant pipe line of both discharge & suction including binding and rapping with insulation tape at both the ends complete all as specified and directed.
Repair/ Servicing of Water Cooler of any make having 40 to 150 Liters of cooling capacity per hour and storage capacity upto 150 Ltrs by disconnecting the water connection, inserting dead plug, dismantling the fan motor, taps, fan blades, condenser etc., including replacement of worn out/ damaged parts, accessories, checking wire connection, reassembling and testing complete all as specified and directed. Note: (i) Cost of spare parts replaced during the process of repair/servicing shall be measured and paid separately as supply only under relevant item herein after. (ii) Labour charges for replacement of spares parts if any required during repair/ servicing of water cooler deemed to be included in the quoted rate.
Supply only following spares required for replacement during the process of servicing/ repairing of Water Cooler herein before.
Thermostat switch with knob
Push tap inner thread chromimum plated D type of size 15 mm dia.
Push tap outer thread chromimum plated D type of size 15 mm dia.
PVC flexible drain water pipe of bore 32 mm suitable for water cooler drain water.
PVC connections 15mm size with PTMT nuts of length 450mm
Condenser fan motor 230 Volts, AC 50 Hz 1/35 Watt
Capacitor 10 Mfd
Capacitor 6 Mfd
Capacitor 4 Mfd
Relay for water cooler
Steel drain water tray suitable for water cooler size 40/60 ltr capacity
Flexible cord of size 3 Core 2.5 Sqmm 3 mtr length stranded copper conductor ISI Marked
Compressor Sealed unit for water cooler capacity 40/ 80 Ltrs.
Compressor Sealed unit for water cooler capacity 60/ 120 Ltrs
Compressor Sealed unit for water cooler capacity 120/ 150 Ltrs.
Copper Capillary tube-0.40 mm
Drier filter
Stainless steel chromium plated Lock with key set
Float valve (inner thread) 1/2 inch with aluminium rod
PVC flexible pipe for over flow 15 mm
Running capacitor 15 MFD
Fan blade Aluminium 40/60
Fan blade Aluminium 60/120
Copper Condensor coil for water cooler 40/60
Copper Condensor coil for water cooler 60/120
M&L for one coat of spray painting using synthetic enamel paint on outer area of water cooler of storage capacity upto 150 Ltrs including necessary preparation of surface complete all as specified and directed. Note: The choice of colour shall be as decided by Engineer-in-Charge.
M&L for cleaning of the water cooler; cold water tank of storage of capacity upto 150 Liters by using PVC wire scrubber to remove dirt, scales from tank and washing the tank with bleaching powder to make the tank bacteria free and disposing off the rubbish/dirty water safely in low lying areas of defence land, writing “TANK CLEANED ON…..”(date), “DUE DATE ON…..(date) with 5 cm height x 5cm breadth size white letters on black back ground by engaging skilled artist using best quality synthetic enamel paint complete all as specified and directed. Note: Contractor has to maintain a register for cleaning of tank duly obtaining signature from user and Engineer-in-Charge for record.
M&L for half yearly maintenance/ repair/ servicing of water purifier of any type and brand by taking down, dismantling, cleaning and replacing worn out/damaged parts such as carbon filter, UV lamp etc., including reassembling, refixing, connecting up and testing complete all as specified and directed. Note: (i) Cost of spare parts replaced during the process of repair/servicing shall be measured and paid separately as supply only under relevant item herein after. (ii) Labour charges for replacement of spares parts if any required during repair/ servicing deemed to be included in the quoted rate.
Supply only following spares required for replacement during the process of servicing/ repairing of water purifier herein before.
Carbon filter suitable for Aqua Guard/ Aqua Plus UV, RO, UF+
Carbon filter suitable for Kent UV, RO, UF+
UV Lamp Suitable fot Aqua guard/ Kent purifier
Repair/ Servicing of refrigerator of any capacity by dismantling, cleaning, replacing unserviceable parts & accessories, refilling of refringent gas etc., including reassembling, connecting up and testing complete all as specified and directed. Note :- (i) Cost of spare parts replaced during the process of repair/servicing shall be measured and paid separately as supply only under relevant item herein after. (ii) Labour charges for replacement of spares parts if any required during repair/ servicing deemed to be included in the quoted rate.
Supply only following spares required for replacement during the process of servicing/ repairing of refrigerator herein before.
Copper Capilary tube dia 0.33 mm
Copper Capilary tube dia 0.36 mm
Vegetable tray (as per sample at site)
Chiller tray (as per sample at site)
Door lamp Thread type 10/15 W
Door lamp Pin type 10/15 W
Door switch (push type)
Freezer box (180 ltrs)
Freezer box (210 ltrs)
Freezer box (320-ltrs)
Freezer box (250 ltrs)
Repair/ Servicing of Deep Freezer of any capacity by dismantling, cleaning, replacing unserviceable parts & accessories, refilling of refringent gas etc., including reassembling, connecting up and testing complete all as specified and directed. Note: - (i) Cost of spare parts replaced during the process of repair/servicing shall be measured and paid separately as supply only under relevant item herein after. (ii) Labour charges for replacement of spares parts if any required during repair/ servicing deemed to be included in the quoted rate.
Supply only following spares required for replacement during the process of servicing/ repairing of refrigerator of capacity upto 320 Ltrs / Deep Freezer of capacity upto 425 Ltrs herein before.
Starting capacitor 80/100 MFD
Running capacitor 10/15 MFD
Filter drier
Copper Capillarly tube dia - 0.25 mm
Thermostat Switch Defrost Type with Knob
Relay for Refrigerator
PVC Refrigerator stand
Filter Drier
Flexible cord with moulded plug 5 Amps of size 3 core 2.5 Sqmm PVC insulated copper 3 Mtr length with ISI Marked.
Handle
Chromium plated SS lock withkey set
Supply and fix in repairs the following items for refrigerator of capacity upto 320 Ltrs/ Deep Freezer of capacity upto 425 Ltrs
Compressor unit for deepfreezer of capacity 425 ltrs -1/2 HP
Compressor sealed unit 1/6 HP sealed unit for Refrigerator
Compressor sealed unit1/8 HP sealed unit for Refrigerator
Condenser Fan motor (Magnetic) - 220v AC
Repair/servicing of desert cooler of capacity upto 3000/4000 CFM by dismantling the fan, motor, pumps etc., including checking up/ rectification of wire connections, replacement unserviceable parts & accessories, cleaning of the water tank, replacement of piping system, khas pads, reassembling, connecting up and testing complete all as specified and directed. Note :- (i) Cost of spare parts replaced during the process of repair/servicing shall be measured and paid separately as supply only under relevant item herein after. (ii) Labour charges for replacement of spares parts if any required during repair/ servicing deemed to be included in the quoted rate.
Supply only following spares required for replacement during the process of servicing/ repairing of Desert Cooler herein before.
Khas pad for desert cooler 2.5' x 2'
Khas Pad of size 2' x 3'
Khas pad of size 1.5' x 3'
Desert Cooler fan motor 1/6 HP exhaust type, 1400 RPM, ISI marked
Desert Cooler Fan & motor bracket
Heavy duty metal Four wing fan blade
Pump Submersible type; 35 watts, 6 feet head suitable for desert cooler. ISI marked
Two Way piano switch 6 Amp
Rotary Knob
Flexible cord with moulded plug 5 Amps of size 3 Core 1.5 Sqmm, 3 Mtr Length PVC insulated copper with ISI Marked.
Capacitor 4/3.15 mfd for Desert cooler
Supplying only pre painted Desert Cooler body of size: 0.9m width, 1.21m height, 0.6 m length complete all as specified and directed. Note: The thickness of sheet metal, material of construction of the Desert Cooler body shall be as per sample model kept at AGE E/M Store yard. Contractor may visit the AGE E/M store yard to know the detailed specification before quoting.
Supplying only pre painted Desert Cooler body of size: 0.7m width, 0.9m height, 0.5 m length complete all as specified and directed. Note: The thickness of sheet metal, material of construction of the Desert Cooler body shall be as per sample model kept at AGE E/M Store yard. Contractor may visit the AGE E/M store yard to know the detailed specification before quoting.
M&L for gas welding/brazing of capillary connections in the refrigerant circuit using copper rod for refrigerator/ watercooler/ window type AC/ Split AC/ Deep Freezer complete all as directed by EIC at site. Note: Copper Tubing Required will be measured and paid separately under relevant item
Supply and fixing in repairs Sheet Metal enclosure with 2 pin and earth plug and socket 20 Amps complete all as specified and directed.
Supply and fixing in repairs MCB SP of Capacity upto 32 Amps 240 Volts complete all as specified and directed
Supply and fixing in repairs industrial top metal clad for AC box Capacity upto 20 Amps 240 Volts complete all as specified and directed.
Supply and fixing in repairs industrial socket metal clad for AC box Capacity upto 20 Amps 240 Volts complete all as specified and directed.
Supply and fixing in repairs 15mm bore tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified & directed.
Supply and fixing in repairs 20mm bore tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified & directed.
Supply and fixing in repairs 20 mm dia bore Stop cock, fancy type, chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of union and fixed complete all as specified and directed.
Supply and fixing in repairs 15 mm dia bore Stop cock, fancy type, chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of union and fixed complete all as specified and directed.
Supply and fixing in repairs 40mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
Supply and fix in repair PVC Insulated Copper flexible cable 3 Core of size 0.5 Sqmm 1100 Volts grade to be incorporated in repairs to fan
Supply and fix in repair flexible PVC pipe connections 15 mm dia with brass nuts of length 450 mm suitable for hot Water
M & L for servicing of air blast type electrically operated chimmey installed in cook houses by dismantling complete filter assemblies/ducts and connected items for descaling with suitable chemical solution/costic soda including reassembling and testing complete all as specified and directed.
M&L for rewinding blower motor 3 phase 415 volts 1400 RPM; 3 HP with suitable gauge winding wire, insulating papers, varnish etc., including taking down the blower motor from existing pillar and transporting it to civil work shop for winding, replacing ball bearing (2 Nos), shifting back to same location, refixing and testing complete all as specified and as directed.
Supply & Fix in repairs outdoor bracket suitable for Split AC upto 2 TR
M&L for re-filling refrigerant gas suitable for window AC/ Split type AC/ Refrigerator/ Deep freezer/ Water cooler etc., including testing the system for 8 hours each at a pressure not less than 10 Kg/Sqcm and vacuum complete all as specified and directed. Note: (i) Cost of refringent gas refilled shall be measured and paid separately as supply only under relevant items herein after. (ii) Contractor has to refill the gas without any addtional payment incase of any leakage/ shortage of gas/shortage of cooling effect.
Supply only following type refrigerant gas suitable for window AC/ Split type AC/ Refrigerator/ Deep freezer/ Water cooler etc., all as specified and directed.
S & F in repairs 3 pin plug top 16 AMP
S & F in repairs 3 pin plug top 5 AMP
S & F repairs fuse links with 74°C rating of fire dampers
M & L for submain wiring with approved colour coding as per IS with single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked drawn through through heavy duty ISI marked surface mounted PVC conduit, not less than 20mm dia with and including fittings all as per relevant IS all as specified complete for the following size:-
2 runs of 4 Sqmm size main cable and one run of 2.5 Sqmm size earth continuity conductor
S & F in repairs electronic voltage stabilizer single phase rating 16 Amps working range 170V -270V suitable for air conditioner of capacity 5 KVA
S & F in repairs eletronic voltage stabilizer sngle phase rating 12 Amps working range 170V - 270V suitable for airconditioner/ water coolers of capacity 4 KVA
Note:- (i) The amount against Schedule of Credit on Page No. shall be deducted from the total amount quoted against Sch 'A' while deriving the Contarct Sum for Acceptance.
Shri Sai Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .