Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L1 | Accepted-AOC L1 | |
| 2 | L2₹38.7 L+₹1.2 L (3.29%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹40.1 L+₹2.6 L (7.02%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
19 Aug 2023, 6:00 pmClosed
GE Bharatpur
GE Kanjoli line Bharatpur-321026
Repair maintenance of DG sets, pump sets cleaning of OH tanks UG sumps open well and repairs to MES installation at RMS Dholpur
2023_MES_606880_1
8305/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bharatpur
As per NIT
6 documents required · 6 mandatory
₹500
GE Bharatpur
₹80,000
Yes
18 Sept 2023
30 Jun 2023
21 Aug 2023
30 Jun 2023
19 Aug 2023
4 Aug 2023
1 Jul 2023 - 18 Jul 2023
Amount
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out/laying LT UG cable, Stay wire and LT pole/post holes etc and getting out in hard/disintegrated layer complete all specified/directed
Removing excavated soil at a distance not exc 50 m and deposited where directed complete all as directed
Returning,filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as directed
Supply & laying sub class B bricks, locally available un-burnt bricks suitable for LT cable protection cover all as specified and as directed by Engineer-in-Charge
M &L local river sand for bedding ang sand cushioning of all LT UG cable all as specified and directed by Engr-in-Charge. (Punned thickness of sand shall be measured.)
Supply, laying and testing cable XLPE insulated,screened, PVC bedded, galvanised steel strip or wire armoured,electric power cable (heavy duty) with stranded aluminium conductor 1100V grade , 3 1/2 core of size 70 Sqmm, rate including taking out of old UNSV cable from trench/floor etc all as specified and as directed by Engineer-in-Charge. Make: Polycab/Havells/Gloster
Supply, laying and testing cable XLPE insulated, screened PVC bedded, galvanised steel stripped or wire armoured electric cable heavy duty with stranded aluminium conductor , 1100Volts grade of size 16 Sqmm 4 core all as specified and directed by Engineer in Charge.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable of three core 95 Sqmm with stranded copper conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole from transformer to panel all as specified and directed
M&L for rewinding of 7.5/5 HP monoblock pumpset installed at Gundrai Sump and cdts hostel including taking out from mounting , disconnecting all electrical and water connections , transportation to workshop and installaing back after rewinding, replacing defective capacitor, impeller housing, bearing, GI fittings of 20mm all kind, lathe work if required, testing as per the Govt procedure after installation etc all as specified and as directed by Engineer-in-Charge.
M&L for painting of aluminium coat over Steel tubular pole and cross arms any size and height including preparration of metallic surface with sand papers and applying one coat of metallic primer before applying aluminium paint all as specified and as directed by Engineer-in-Charge. Make of paint: Berger/Asian Paints. Note: Location - Gundrai to Kesarbagh area. During school hours Shutdown shall be given after getting approval from the Stn I/C oficer and during holidays shutdown shall be given after consulting with Engineer-in-Charge. Continuous shutdown more than 4Hrs shall not be given in a single day because of water supply constraints. All kind of safety deivces, vehicles and ladders shall be arranged by the contractor at site.
S&F glow sign board of white polished transparent acrylic cover of minimum 2mm thick, unbreakable, heat resistive etc including M&L of steel fabrication of angles and supports of thickness not less than 2mm thick (thickness shall be variable upto 5mm as per site conditions) rectangular box type of size minimum 180cm x 90cm x 20cm thick, computerised letter of blue colour of size 30cm high and 3 to 5cm width or small as per site requirement having glue on backside to stick permanently, including all kind of securing, welding, assembling with proper allignment and height with fine look, including PCC, cement work, excavation if required, LED tube light fittings 1x 20Watt, including connecting wires and switch independent one way 5Amp with well finish of weather proof suitable for exposing at all weathers including taking down of old UNSV all as specified and as directed by Engineer-in-Charge.
S&F glow sign board of white polished transparent acrylic cover of minimum 2mm thick, unbreakable, heat resistive etc including M&L of steel fabrication of angles and supports of thickness not less than 2mm thick (thickness shall be variable upto 5mm as per site conditions) rectangular box type of size minimum 400cm x 60cm x 20cm thick, computerised letter of blue colour of size 30cm high and 3 to 5cm width or small as per site requirement having glue on backside to stick permanently, including all kind of securing, welding, assembling with proper allignment and height with fine look, PCC, cement work, excavation if required, LED tube light fittings 1x 20Watt, including connecting wires and switch independent one way 5Amp with well finish of weather proof suitable for exposing at all weathers including taking down of old UNSV all as specified and as directed by Engineer-in-Charge.
S&F in replacement LED street light fittings with excellent thermal management of 90 Watt Ip-65 with complete accessories on existing brackets fixed on MES installation bldgs at Gundrai and Kesarbagh palace including taking down the old UNSV one and connecting up the lights to the nearest point by using 1sqmm copper wire 2 run and replacing the brackets and clamps if required , drilling holes on stone masonry all as specified and as directed by Engineer-in-Charge. Make Havells, Cat part No LHETBXU7PN6J090
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete fittings such as switches, ceiling roses, pendents, regulators, sockets etc removing materials for taking credit and making good disturbed surfaces of wall, floor & ceiling etc.
Taking down old U/S rusted main switch/DB of any size capacity and description complete all as specified and directed.
Taking down old U/S sub main wiring of any size & description complete all as specified and directed.
M&L point wiring complete with 1.5 Sqmm 02 x single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in and including PVC casing and caping double locked box type with all PVC accessories such as Tee, bend, collar, elbow, square junction box etc fixed on the surface of wall/ceiling by means of PVCsleevel/dash fastners with cadmium plated screws including suitable size of PVC boards for mounting fittings like switches, sockets, fan regulator etc including 1.5 Sqmm insulated but unsheathed copper earth continuity conductor to common earth and connedcted to earth dolly complete all as specified and directed for the following :-
One light point controlled by one, one way switch.
One fan point controlled by one, one way switch.
One 3 pin 6 Amp socket point outlet on the same board with other switches
One 3 pin 6 Amp socket point outlet on the independent board
All as per item No 17 above but with multi stranded copper conductor cable 2.5 Sqmm size for 3 pin 16 Amps socket point outlet on independent board including 2.5 Sqmm copper cable PVC insulated FRLS unsheathed copper continuous earth wire including connecting to common earth dolly complete all as specified and directed.
S&F socket outlet 2 in 1, 5pin, 6 Amps multi purpose flush type 230 volt Make : Anchor code No 95015 penta or equivelent in Legrand/Havells/ SSK complete all as specified and directed.
S&F switch socket combination 2 in 1, 16 Amp flush type multi purpose 230 volt make : Anchor code No 4282 penta or equivelent in Legrand/Havells/ SSK complete all as specified and directed.
S&F switch piano flush button single pole one way 6 Amps 230 volt grade Make : Anchor Code No 95111 Penta or equivelent in Legrand/Havells/ SSK complete all as specified and directed.
S&F ceiling rose surface bakelite 50 x 40 mm three terminal ISI marked including suitable size of PVC board make : Anchor code No 3290 penta or equivelent in Legrand/Havells/ SSK complete all as specified and directed.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required complete all as specified and directed.
M&L submain wiring complete with 4 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 4 Sqmm copper cable for earth continuity conductor in and including drawn through PVC casing capping PVC conduit/sleeves with all PVC accessories fixed on wall, floor/ceiling etc. complete all as specified and directed.
M & L for Distribution board factory made and tested made of sheet metal enclosure powder coated suitable for mounting the MCB 240 volt of the following DBs :- Makes -L & T / Legrand/ Havells/HPL
8 way SPN with200 Amp rated busbar 240 volts (double door type).
4 Way SPN with 200Amp rated busbar 240V (Double door type)
S&F MCB 240 volts 10 KA, rupturing capacity fixed in DB's of the undermentioned type and rating. Make : L&T/ Legrand/ Havells/HPL
MCB SP 240 volts 10-40 Amps
MCB SPN 240 volts, 40 Amps
S&F tube light frame slim type with Photon Ultra LED glass crystal tube rod 20 Watt suitable for replacing 1200m length LED tube rod, prewired with complete accessories suitable for fixing on wall/ceiling complete ,both tube rod and fitting are seperate all as specified and as directed by Engineer-in-Charge. Make - Havells Cat Part No REGALBATTENT8UPTO1X22WSSBSWH or equivalent in Phillips/Bajaj/CG
M&L batten/angle holder insulated with back plate including suitable size of PVC round block make Anchor code No 51205/SSK/ Havells
Material and labour for renewal of Chemical Earthing complete with copper earth plate electrode of size 900x600x3mm thick buried directly in ground (earth pit should not less than 4 mtr deep below normal ground level ) with top edge of the plate not less than 2.95 mtr deep below normal ground connected to and included copper earth strip 32mmx 6mm by means of copper bolts nuts check nuts and washer returning and filling the pits with excaviated vsoil mixing with charcoal 250 kg crystal salt 200 kg magnisiun sulphate of 100 kg and vegitable soil all around the plate up to 350 mm above from top edge of plate and balence portion filling with excaviated soil in layers not exc 25 mm thick 25 mm bore galvanised iron medium grade watering pipe up to top of plate 50mm bore galvanised iron light grade pipe for earth strip protection including all excavation earth work in any type of soil pcc 1;3;6 type c1 ....for chamber of internal size 300mmx 300mmx300mm with 120mm thick wall and 700mmx700mmx150mm thick bed concreat RCC 1:2:4 ,type b1 for precast chamber cover 50mm thick reinforced with welded steel wire fabric orxPM jali (weight not less than 4.00 kg/sqmm) ,funnel,with wire mesh complete all as specied and directed. Note (i) Quoted rate shall be deemed to include for earth strip with protection pipe up to 7.5 M length
M&L for Cutting anxious green growth / vegetation growth from root for cleaning out the area around OH tank / pump house No-1&2&3 at Gundrai and kesharbagh sbustation , Kesarbagh sump house and at ground level by cutting up root, un- wanted plants / bushes and removal the same to a distance not less than 50 mtr directed by engineer -in -charge , Note: (i) Rate including Cutting T&P, transporting / disposal /dumping away from the site as per the laid down procedure of waste management system shall be considered with this item rate. (ii) Entire site shall not be given for one time. Area for cleaning shall be given to the contractor on requirement basis as per the site conditions and growth rate of bushes and grass etc. The area shall be divided into several parts and shall be directed to the contractor when cleaning is required at site.
Supply and fix on load change over switch 415 V in sheet metel enclouser 4 pole of capacity 160 amp all as specified and directed by engineer -in-charge
Supply and fix on load change over switch 415 v in sheet metel enclouser 4 pole of capacity 200 amp all as specified and directed by engineer -in-charge
Supply and fixing in replacement of sluice valves of cast iron body with forged brass spindle, class PN 1.6 and cast iron wheel head, both ends flanged, IS-1486 marked complete with neoprene rubber gasket joints, nuts, bolts (high tensile), and washers etc all as specified and directed (Make : Upadhyay/ Kejriwal iron and steel works/ Kirlosker/Bir/L&T) of following size:-
150mm bore flanged end.
100mm bore flanged end.
Supply and fixing in replacement of non return valve, flanged ends PN 1.0 ISI marked of 100mm bore (Make : Upadhyay/ Kejriwal Iron and steel work/ Kirloskar/ Bir/L&T).
Supply and fixing in replacement of non return valve, flanged ends PN 1.0 ISI marked of 80mm bore (Make : Upadhyay/ Kejriwal Iron and steel work/ Kirloskar/ Bir/L&T).
Supply and fixing in repair of GI water tubing IS-1239 marked, medium grade, in replacement including all necessary pipe fittings laid in trenches, on wall, under floor, under road on same or new route and making good the disturbed portion as existing and including taking down of old unserviciable pipe of the following sizes :- Note :-excavation earth work will be measured and paid saperatly. Make : Jindal/Prakash/Suraya
15mm bore
20mm bore
25mm bore
40mm bore
Taking out old Existing U/S MCCB from LT panels/ Feeder piller of following capacity and replace with new MCCBs without damaging the LT panel board or any assets associated with the installation. Make Havells/L&T/ABB/Schneider.
MCCB 4 pole TPN, 160Amps capacity, 36KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Ics = 50% of Icu,
MCCB 4 pole TPN, 200Amps capacity, 36KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Ics = 50% of Icu,
MCCB 4 pole TPN, 400 Amps capacity, 36KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Ics = 50% of Icu,
MCCB 3 pole TP, 63 Amps capacity, 16KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Ics = 50% of Icu,
MCCB 3 pole TP,100Amps capacity, 16KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Ics = 50% of Icu,
Material and labour for Rotational moulded polyethylene water storage tanks 1000Ltr (cylindrical vertical with closed top) hoisted and fixed in position with float valve all as specified in SSR Part I complete all as specified and directed.
supply and fix Rubber mat of 1 meter x 2 meter x 25 mm all as specified and directed by engineer-in-charge
Supply and fix electric rubber hand gloves (two glooves for each person)11KV all as specified and as directed
Supply,connect,fix and test submersible cables copper conductor PVC insulated over all sheathed flat flexible, ISI marked - Conforming to IS 694,1100 volts grade complete of sizes Note: Spares shall be measured & paid separately for dismantling of DG set partly or full shall be paid accordingly.
10 sqmm 3 core
16 sqmm 3 core
Servicing of industrial RO Plant installed at academic complex including back washing, cleansing the filter medium, resetting all TDS upto the recommended level by PHED, checking all valves, servicing the turbo jet motor for raw water, checking and tighting all mounting brackets, nuts. Bolts etc. removing fungus by cleaning of raw water and filtered water storage tank all as specified and as directed by Engineer-in-Charge. Note: Technician shall be hired from reputed company of the RO plant. No extra allowance shall be be given to the technician. Coneyance shall be arranged by the contractor, No vehicle shall be provided for the conveyance of the technician by MES.
S&F for replacement of the following spare parts of RO plant of capacity 40 to 200LPH installed at academic complex:
Primary sediment cartridge Filter
Secondary sediment cartridge Filter
RO membrane as per the existing make and model suitable for 200LPH capacity
Rewinding of raw water motor and servicing of pumpassembly of capacity 2HP
PCB control panel with LED display and mounting accessories and testing etc
supply and fix of ^lithium based Energy Efficient Integrated solar street light of 32 watt ^ in single FRP body with duly polyurethane coating(camouflage colour),encases with monocrystalline solar PV panel of 65-67 Wp ,lithium battery 11.1/12.8 v 33 AH with inbuilt BMS IP 65 high brightness W-LED (160/180 lm /watt) lamp with aluminium reflector for better light distrubtion CRI>70 colour temperature 5700-6500K . microcontroller basedcharge controller cum driver automatic diming function (frist four hour at full brightness and rest of the time at lower light level with PIR motion sensor dusk to dawn operation sutiable to working temperature -10 to 55 C .weight not more than 14-16 kg with adjustiable MS clamp sutiable for pole wall mounting etc complete as requirer protection-short circuit overload reverse polarity and battery protection firm should provide vital parameter test report from NABL accredited lab and should be made in india with CE and ROHS complaint Make-Axxon/BHEL/TATA/Havells
Taking out submersible pump set of capacity 40HP/20HP 3 Phase 415 volt AC supply alongwith column pipes from the bore well by disconnecting electric connection, disconnecting the motor from pump dismantling the motor & over hauling the same by repairing/ replacing defective part as ordered & re-assembling including M&L for replacing worn- out nuts bolts washers complete, connecting /coupling the motor with pump & with column pipes & lowering the same after repairing, making the connecion complete all as directed by Engr-in-Charge. Note: Spares shall be measured & paid separately for dismantling of pump set partly or full shall be paid accordingly.
Supply only following spare parts for above submersible pump at item No 45 of BOQ here-in-above.
Hook bolt
Motor Bush
Rubber Bush
SS Bush
Stud with nuts & bolts
Neck Ring
Impeller
Top/Bottom bearing bush
SS Rooter sleeves
Thrust Plate
SS shaft
Bowl Bush
Diffuser CI/Steel
M&L for rewinding the submersible Motor 40HP/20HP with super enamaled copper winding wire of suitable gauge & superior class of insulation including insulation paper sleeves thimbles etc & testing complete all as specified and directed.
Cleaning of RCC overhead reservoir of 75,000 GLN capacity of 18 Mtr staging including draining out water. Removing, Mud, Slit/dust from Tank. Washing & rubbing with gunny bags & cleaning with fresh water & Bleaching powder including writing the date of cleaning etc by synthetic enamal paint all as directed by Engr-in-Charge. Note :- (a) All necessary ladder and scaffolding arrangement shall be made by the contractor. (b) All kind of safety equipments shall be arranged at site by the contractor. (c) In case any outlet pipeline/control valves damaged during operation, shall be borne by the contractor (d) Disturbed portion if any shall be made good as per existing by the contractor
Cleaning of Masonry /RCC under ground sump of 50000 GLN capacity, Located at Gundrai pump house No 1, including the following works: - (i) draining out water with the help of monoblock pumpset (pumpset shall be managed by the contractor) (ii) Removing, Mud, Slit/dust from sump by manually & rubbing & cleaning with gunny bags etc (iii) washing with fresh water & Bleaching powder twon times (iv) writing the date of cleaning etc by synthetic enamel paint (v) applying two coat of light blue colour synthetic enamel wall paint internally upto 84SQM on inside of floor and all walls all as directed by Engr-in-Charge.
Cleaning of Masonry /RCC under ground sump of 25000 LTR capacity loacted at Cadets hostel area including the following works: (i) draining out water with the help of monoblock pumpset (pumpset shall be managed by the contractor) (ii) Removing, Mud, Slit/dust from sump by manually & rubbing & cleaning with gunny bags etc (iii) washing with fresh water & Bleaching powder twon times (iv) writing the date of cleaning etc by synthetic enamel paint (v) applying two coat of white wash.
Cleaning of Masonry /RCC under ground sump of 25000 GLN capacity loacted at Kesarbagh Sump House area including the following works: (i) draining out water with the help of monoblock pumpset (pumpset shall be managed by the contractor) (ii) Removing, Mud, Slit/dust from sump by manually & rubbing & cleaning with gunny bags etc (iii) washing with fresh water & Bleaching powder twon times (iv) writing the date of cleaning etc by synthetic enamel paint (v) applying two coat of white wash.
Dismantling electric motor of centrifugal pump 3 phase for 440 volt 30 HP and rewinding of motor with super enameled copper wire of same guage & turn including material, varnishing, re-assembling, testing & commissioning /complete all as directed by Engr-in-Charge Note: Spares parts shall be measured & paid separately. For dismantling of pump set partially or complete shall be paid accordingly.
Supply only spare parts for above Centrifugal Pump of 30 HP at item No 52 above
Ball bearing SKF/NBC (6309)
Pump shaft with Key
Coupling Key
Gland Plate (Set of two)
Suction/Discharge stud/Nuts/ Bolts
Gland Bush (Gun metal)
Coupling rubberised
Foot valve 80mm GI or CI heavy grade as per existing
M&L for rewinding the Submersible pump Motor 5HP/7.5HP with super enamaled copper winding wire of suitable guage & class of insulation including insulation paper sleeves thimbles etc & testing.
Servicing of DG set 82.5KVA and 63 KVA water/air cooled (Kirloskar) by unscrewing nuts, bolts and servicing of DG set with checking, draining and changing of Engine oil and Coolant, checking and changing of V-belts, greasing and oiling of all relevant parts and topping up, Cleaning the inner body of Fuel tank and Radiator etc by removing sludge etc and reassembling the DG set after repair and replacement of unserviceable parts of DG set including repair of control panel, opening of alternator, water pump, starter motor for cleaning, servicing and refixing. Checking and servicing of Battery and testing complete in all respect all as directed by Engr-in-charge. Note: Spares shall be measured & paid separately for dismantling of DG set partly or full shall be paid accordingly.
Supply only following spare parts for item above DG Set item No. 55 above :-
Air cleaner element
Water hoses including clamps complete all as specified.
Fuel filter element.
Lubrication oil filter
Fuel Pipe
Piston & Rings
Fan belt.
Head Gasket
RC Joint, Set of O Rings, Set of Joints
Valve Pair, Valve seal and Valve guide
Battery 150 AH (Type Flat Bed, Maintenance Free) Make :- Exide/ Amaron/ Luminous
Oil Pipes including clamps complete all as specified
coolant in one/two ltrs packing complete all as specified and directed by Engineer-in-Charge.
Supply only distilled water in one/two ltrs packing.
Supply & filling oil of recommended grade (DF-4, 15 W 40) Make Servo.(in 5 Litres Can) Required 20 Litres all as specified and directed by Engineer-in-Charge.
Supply and fixing of the following spare parts of FASD starters:
Contactor switch 25Amp capacity, with 380-415V coil, ML model of L&T or equivalent
Contactor switch 40Amp capacity, with 380-415V coil, ML model of L&T or equivalent
Contactor switch 70Amp capacity, with 380-415V coil, ML model of L&T or equivalent
Start/Stop push button toggle switch
Starter relay 415V, 40Amp or above upto existing capcity range
Multi controller/single phase preventer & timer switch relay in single box capacity ranging from 7.5HP to 40HP make L&T, cat part No CS94824D000
GI Foot valve 40mm heavy type
Copper lugs of size 16 to 25sqmm
Aluminium lugs of size 50 to 120sqmm
Supply and fixing in replacement of old unsv Direct Online Starter of capacity 7.5HP suitable for monoblock pumpsets installed at cadets hostel area complete all as specified and as directed by Engineer-in-Charge. Make L&T, cat part No SS96211 or equivalent approved Make
Replacement in Repair fully automatic star delta starter comprising of voltmeter 0-500 V and ammeter 0-100 Amps, single phase preventor, over load relay and timer housed in single MS sheet powder coated enclosure suitable for up to 40 HP and above 70 amp submersible motor pump including first filling of oil in oil chamber (If Required) and testing complete (Make : L&T, Cat Part no CS90908 or equivalent approved make)
Labour only for servicing APFC panel board and cochecking all the contact terminals and capacitors, repairing the terminal wire circuits, tightening all kind of nuta sn bolts, screws atc, cleaning inside the chamber, enclosure etc, checking the connection of CT coil from panel to main incoming source and repairing in case of any fault in connections all as specified and as directed by Engineer-in-Charge. Note: Replacement of Spares shall be measured and paid separately.
Supply and replacement and testing at site of the following accessories of APFC panel:-
Cylidrical series capacitors, KVAr rating 2, 440V, 3Ph, heavy duty, make L&T, Cta part No LTCOH or equivalent
Cylindrical series capacitors, KVAr rating 5, 440V, 3Ph, heavy duty, make L&T, Cta part No LTCOH or equivalent
Cylidrical series capacitors, KVAr rating 10, 440V, 3Ph, heavy duty, make L&T, Cta part No LTCOH or equivalent
VAF + PF meter accuracy class 1.0. 0.5, input voltage measurement range 50 - 520 VAC (P-P), Aux supply 80-300 VAC/DC, CT secondary side 1A/5A, Flush mounting 96x96, CT/PT programmable, Para meters VLL, VLN, A, F, PF, On Hrs, RPM, Apeak etc with RS485, Cl-1, Make L&T, Cat Part No WL4110110000 or equivalent approved make
Excavating in post holes (or similar holes) each n. exc. 0.5 cum, gettting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc. 25 cm, watering and removing surplus soil to a distance n exc. 50 mtr in soft disintigrated rock and making good surface complete all as specified and directed.
M &L PCC (1 :4:8) type D2 (using 40mm agg ) as in foundation filling and Mass concerete in post holes all as specified and directed by engineer-in-charrge
S&F Angle iron fencing post and struts including cutting tops to shape as directed drilling holes, notching for wire etc, flat iron fillets (for securing wire mess etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe 410-0 or Fe 310-0 including round bars etc complete all as specified and directed.
Fixing only chain link fencing including line wire any mesh size and type of standards raills, starining bolts ewtc including provisioning of binding wire complete all as spd & directed by EIC.
Supply only chain link MS galvanised fencing any size or type complete all as spd &directed .
S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strainging bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or stel pins, etc. as directed (each line wire to be measured) complete all as specified and directed.
Mild steel screw bots (machine made ) with hexagonal or square heads at one end and screwed the other each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 05 cm but not exc 10 cm and 10 mm dia complete all as spd &directed.
S&F for Mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
Preparation of new steel surfaces exc 10 cm width or girth and applying two coats of syntetic enamel paint over one coat of red oxide of zinc chrome primer complete all as spd &directed .
Excavation in tranches n. exc. 1.5m wide and n. exc. 1.5m depth for foundation etc. or for shafts ,well cesspits,manholes,pinholes etc. n. exc. 10 Sqm on plan and n. exc. 1.5m depth and getting out soft or loose soil complete all as specified and directed.
M&L for plain cement concrete in foundation filling type C-2 1:3:6 (Using 40mm grade aggreate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for formwork to sids of concerete foundations ,footing,base of colums raft and raft beams sides and softits (If any) of foundation and plinth beams and similar work,vertical or to better complete all as specified and directed.
M&L for framed work such as grills gratings etc wuth ends pf bars shouldered and /or riveted or foged into spikes framed barred iron doors ladders framed balusters ,walk way ,railling, framework of water tanks and similar works confirming to Fe.290,Gde-E-165 including portion framed and hung as gates including pintle hinges stopes, hand made slidinf bolts etc ornamental and intricate design complete all as specified and directed.
M&L for greasing on motor and pumpset nipples , replacing burnt gland packing of any size and of centrifugal/monoblock pumspset of any size and capacity including leakage and damiging testing and obtaining OK result all as specified and as directed by Engineer-in-Charge.
supply and fix Nuprine rubber / Leather gasket minimum thickness 8mm suitable for tightening the GI flange or any othe joints of 100mm dia with nuts and bolts,
M&L for PCC 1:3:6 type C-1 (using 20 mm gradewd stone aggregate) as in flooring for installation area, complete including form work etc all as specified and directed by Engineer in Charge
M & L for dismantling existing broken valve pit complete with corroded MS sheet cover including removal of all material and construction of valve pit chamber, brick masonry all as specified in drg No TD/2004/26 sheet 1/3 to 3/3 for sluice valve including plastering, PCC in foundation excavation and earth work, MS sheet cover (3mm thick) with locking arrangement, painted with two coats of anticorrosive paint over one coat of primer of following sizes:-
1000mmx 950mm x 1000mm
1200 mmx 1200mmx 1000mm
M/s Ranaji Construction Co
Asha Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .