| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC CHANDIGARH | ₹19.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹20.4 LRejected-Finance HOUSE NO 2246 SECTOR 15 C CHANDIGARH | NA | NA | 160001 | ₹20.4 L | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not qualified technical bid |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not qualified technical bid |
| 5 | Rejected-Technical 1128 SECTOR 22 B NEAR AROMA PETROL PUMP CHANDIGARH UT 160022 UDYAM CH 01 0016982 04AACCT5404E1ZV B R MII STATUS AS NOT VERIFIED | CHANDIGARH | CHANDIGARH | 160022 | - | - | Rejected-Technical Not qualified technical bid |
Tender Value
₹19.9 L
EMD Value
₹39,800
Closing Date
13 May 2026, 12:00 pmClosed
Er. Chander Shekhar
Office of the Executive Engineer, Electrical Division No. 3 Sector-4, Chandigarh.
PROVIDING ADDITIONAL FIRE DETECTOR, MCP, HOOTERS ETC. AND INTEGRATED WITH EXISTING SYSTEM IN THE VARIOUS OFFICES/ROOMS IN PUNJAB AND HARYANA HIGH COURT, SECTOR-1, CHANDIGARH. WHERE DETECTION SYSTEM NOT INSTALLED.
2026_CHD_92185_1
E3/47W/30
Open Tender
Electrical Works
90 days
Chandigarh
AS PER NIT
2 documents required · 2 mandatory
₹0
₹39,800
4 Jun 2026
7 May 2026
13 May 2026
7 May 2026
13 May 2026
7 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1DSR Item No.17.2.1 Supplying, installation, testing and commissioning of microprocessor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. | |||||
| 1.01 | Two Loop Panel. | 1 | Each | 2,49,990 | ₹2,49,990 |
| 2 | DSR 17.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required. | 29 | Each | 4,045 | ₹1,17,305 |
| 3 | DSR 17.2.15 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. | 29 | Each | 3,664 | ₹1,06,256 |
| 4 | DSR 17.2.4 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required | 174 | Each | 2,987 | ₹5,19,738 |
| 5 | Supply & erection of loop card compatible with existing system. The card should be of Edwards/Honeywell make and match able with the existing panel. The card operating voltage 24 Volt DC and current 139 mili amp. The cost of other petty items required to set right the panels are also included to complete the job to the entire satisfaction of the Engineer-in-Charge. | 2 | Each | 81,243 | ₹1,62,486 |
| 6 | DSR 17.5.2 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. | 3,510 | P.Mtr. | 181 | ₹6,35,310 |
| 7 | DSR 17.2.10. Supplying, installation, testing & commissioning of addressable fire control module complete as required. | 29 | Each | 3,138 | ₹91,002 |
| 8Supply installation testing & commissioning of LED exit signage: the signage should be made of laser etched acrylic sheet of approx. size 350 x170mm to suit 30m or as per standards, viewing with reflective LED light source of minimum 2 W having battery backup (minimum 2 hours) with battery charger. The assembly should have suitable surface /hanging arrangement including connectors with the help of clutch wire / studs/ Chain etc. for hanging the same. The size of text/ symbol and location for the signage to be approved by the engineer in charge before installation. The job includes all labour & petty material required to complete the job in entire satisfaction of EIC. Make Glowline/ Powertech/Agni make only. | |||||
| 8.01 | Double side | 31 | Each | 3,398 | ₹1,05,338 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 24.67 MB
BOQ_112809.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid