Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹30.9 L+₹1.5 L (5.20%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹31.8 L+₹2.4 L (8.33%)Rejected-Finance 11 1 7 P D KYDGANJ PRAYAGRAJ U P PIN 211003 | PRAYAGRAJ | UTTAR PRADESH | 211003 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹33.7 L+₹4.3 L (14.6%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹37.1 L+₹7.7 L (26.4%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹35.8 L
EMD Value
₹71,600
Closing Date
20 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (East) Prayagraj
Stanley Road, Teliyarganj, Prayagraj
Provision of pathway at 39 GTC, 01 X Toilet near X Ray department of MH, patient toilet, 04 X urinal point and wash hand basin at ITA of 39 GTC and 03 X B Veh open garage near ADM block at Varanasi under GE (East) Prayagraj.
2023_MES_615236_1
8664/E8
Open Tender
Civil Works
Item Rate
180 days
Varanasi
As Per NIT
7 documents required · 7 mandatory
₹500
GE (East) Prayagraj
₹71,600
Yes
25 Nov 2023
23 Aug 2023
22 Sept 2023
23 Aug 2023
20 Sept 2023
6 Sept 2023
Amount
Surface excavation in any type of soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and directed.
Excavating in trenches, in any type of soil not exceeding 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out complete all as specified and directed.
M&L for plain cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete including sub base of under floors complete all as specified and directed.
M&L for reinforced cement concrete design mix M-25 (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed.
M&L for reinforced cement concrete design mix M-25 (using 20 mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span in complete all as specified and directed.
M&L for mild steel TMT bars 10 mm dia & over cut to length bent to shape required including cranking bending, spirally for hooking for columns hooking and binding with including mild steel annealed wire not less than 0.9 mm dia securing with clips complete all as specified and directed.
M&L for mild steel TMT bars 8 mm dia cut to length bent to shape required including cranking bending, spirally for hooking for columns hooking and binding with including mild steel annealed wire not less than 0.9 mm dia securing with clips complete all as specified and directed.
M&L for mild steel TMT bars 8 mm dia cut to length bent to shape required including cranking bending, spirally for hooking as in stirrups and binding with including mild steel annealed wire not less than 0.9 mm dia securing with clips complete all as specified and directed.
M&L for use and waste form work in flat surfaces to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, complete all as specified and directed.
M&L for use and waste form work in flat surfaces to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L for 25mm thick PCC, 1:2:4 Type B-0 (using 12.5 mm graded crushed stone aggregate) as in damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed.
M&L for brick work with fly ash old size bricks, straight or curved on plan exceeding 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick wall in CM 1:6 finished even & fair complete all as specified and directed.
M&L for 15mm thick plastering on other than fair faces of brick wall in CM (1:4) surface finished, even and fair without using extra cement complete all as specified and directed.
M&L for 5mm thick plastering on ceiling in CM (1:3) surface finished, even and fair without using extra cement complete all as specified and directed.
S&F 30 mm thick factory made UPVC door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and jointed at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm ( + 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete all as specified and directed.
S^F factory made uPVC door frame made of uPVC. extruded sections having an overall dimension (extruded section profile) 42x50 mm (tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified and directed.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 150 mm size aluminium anodised handles, cast type complete all as specified and directed.
S&F 100 mm size butt hinges, medium weight extruded stainless steel hinge pin, bright complete all as specified and directed.
S&F Aluminium alloy, anodised, sliding door bolt 250 mm long, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed.
M&L for MS framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square n exc. 0.5 Sqm in each pane complete and all as specified and directed
M&L for plain cement concrete 1:3:6 type C-2 (using 40mm graded aggregate), 75mm thick as in plinth protection/path/hard standing without using extra cement complete all as specified and directed
M&L for plain cement concrete 1:3:6 type C-2, (using 40mm graded aggregate) as in surface channel and drain complete all as specified and directed
M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified and directed .
M&L for hard core broken stone of gauge not exceeding 63 mm, deposited spread and levelled in layers not exceeding 15 cm thick, levelling and rammed to a true surface complete all as specified & directed.
M&L for plain cement concrete 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete including sub base of under floors complete all as specified and directed.
M&L for non - skid joint free coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20mm thick screed bed or bedding layer in CM (1:6) complete all as specified & directed.
M&L for 1mm thick putty for preparation of newly plastered surface including necessary rubbing etc for receiving painting coat complete all as specified & directed.
M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 15mm thick rendering as bed or bedding layer in CM (1:6) complete all as specified & directed.
S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified & directed.
S&F 75 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified & directed.
S&F 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls and floor etc . Complete all as specified and directed.
S&F 15 mm bore galvanised steel water tubing medium grade for water supply pipes & connections with all fittings such as sockets, elbows, unions, Tees & short length etc, and fixed to walls with steel hooks or laid in floors in any length complete all as specified & directed.
S&F 20 mm bore galvanised steel water tubing medium grade for water supply pipes & connections with all fittings such as sockets, elbows, unions, Tees & short length etc, and fixed to walls with steel hooks or laid in floors in any length complete all as specified & directed.
S&F 25 mm bore galvanised steel water tubing medium grade for water supply pipes & connections with all fittings such as sockets, elbows, unions, Tees & short length etc, and fixed to walls with steel hooks or laid in floors in any length complete all as specified & directed.
S&F 500 Litre capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top)Marked double layered, ISI marked, hoisted and fixed in position including necessary connections to inlet / outlet & wash out pipes, complete all as specified & directed.
S&F in position 20 mm bore gun metal gate valve with iron wheel head screwed both ends complete all as specified & directed.
S&F 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod &high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 2 0 m m - 2 1 0 g m s ) complete all as specified & directed
S & F vitreous china, white, urinal, flat back, size of 465 x 355 x 265 mm white (minimum) including providing PTMT spreader and fixing plugs, bedding urinal against wall in cement mortar (1:2) securing urinal to plugs with and including 60mm long screws, pointing around urinal back in cement connecting water pipe and waste pipe complete all as specified & directed.
S&F vitreous China wash hand basin white flat back of size 550 mmx400mm fixed on and fixing of cantilever brackets of mild steel angle 35 mm x 35 mm x 5 mm, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe (rigid quality) including fixing of tap etc. complete all as specified and directed.
S&F vitreous china coloured wash down water closet pan (Pedestal Pattern), , including connection to flush pipe, 'P' or 'S' trap, with fixing PVC seat cover with chromium plated mild steel hinges device (excluding flushing cistern and flush pipe), complete all as specified and directed .
S&F plastic water closet seat cover, closed pattern with flat bottom, including mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
S&F 10 litre capacity PVC, low level, valve less, syphonic action type flushing cistern, inlet ball valve, float valve, handle and fixing arrangement, 32 mm dia PVC flushing pipe and 15mm dia 450mm long PVC connection with CP brass coupling nuts and PVC washer at both ends, complete all as specified and directed .
S&F brass CP mixture for mixing hot and cold water, single hole type as in WHB, screwed down for iron pipe for 15mm dia bore pipe, complete all as specified and directed.
S&F 15 m dia bib taps, chromium plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified & directed
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified & directed.
S&F tubular towel rail of brass chromium plated, 20 mm dia, 'D' type, 60 cm long between flanges including brackets fixed complete all as specified and directed.
S&F stainless steel soap dish of type, size and pattern as capt in AGE's office complete all as specified and directed.
S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed .
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of newly steel surfaces of any description over 10cm width or girth not otherwise described complete all as specified and directed.
M&L for applying two coats of white wash including preparation of newly plastered surfaces of wall complete all as specified and directed.
M&L for applying two coats of white wash including preparation of newly plastered surfaces of ceiling complete all as specified and directed.
M&L for applying two coats of cement base paint including preparation of newly plastered surfaces of wall complete all as specified and directed.
Supply only pillar tap cast copper alloy with capstan heads chromium plated fancy type screwed down high pressure with or without lettered hot or cold with long screwed shank and fly nuts, screwed for iron pipe 15 mm bore complete all as specified and directed.
M&L for reinforced cement concrete design M-25 (using 20 mm graded crushed stone aggregate) as in foundation beams, plinth beams, bases for columns complete all as specified and directed.
M&L for reinforced cement concrete design mix M-25 (using 20 mm graded crushed stone aggregate) as in columns, pillars, piers, posts and sturuts complete all as specified and directed.
M&L for use and waste form work in flat surfaces to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work complete all as specified and directed.
M&L for use and waste form work in flat surfaces to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
M&L for brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
M&L for 25-28 mm thick machine pressed designer [chequered] cement concrete paving tiles [of size 300x300 mm] having wear resistance coating or wear proof topping, tile fixed with @ 3 Kg cement slurry laid over and including 15 mm thick screed bed or bedding layer in cement sand mortar in 1:6 complete all as specified & directed.
S&F PVC (SWR) vent cowl 75 mm complete all as specified and directed.
S&F 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F Vitreous china urinal partition white of size 310mm X 700 mm and pattern as per sample capt in AGE's office complete all as specified and directed.
M&L for moorum/red bajri filling in floors or pavings laid in lays not exceeding 15 cm thick spread levelled and rammed including watering and ramming complete all as specified and directed.
M&L for 75mm thick Cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in levelling course, for floor benching etc, finished even & rough complete all as specified and directed .
M&L for 100 mm thick PCC 1:2:4 type B-1, (using 20 mm graded stone aggregate), finishing cement concrete surface even and smooth Without using extra cement in floors complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006, 80 mm thickness, M-40 Grade and with grey cement and pigment laid over and including 25mm thick sand cushing complete all as specified and directed.
S&F precast cement concrete, 1:2:4 type B-0 (using 12.5mm graded stone aggregate) factory made louvers and jallies, 45 mm thick (measured solid), including all mould- ings but excluding frame, set in cement mortar 1:4, complete all as specified and directed.
M&L for providing water proofing treatment over cleaned roof surface with APP modified bituminous membrane weight not less than 3 Kg per Sqm comprising of the following and testing:- [a] 10 mm thick rendering or screed bed or bedding layer in cement sand mortar 1:4 mixed with water proofing compound @ 3%by weight of cement and surface finished even & fair. [b] Applying one coat of bitumen primer @ 0.3 Litre per Sqm on plastered surface. [c] Applying one coat of hot blown bitumen 85/25 grade @ 1.2 Kg per Sqm. [d] laying APP modified polymeric water proofing membrane having weight not less than 3 Kg per Sqm with 100 mm wide side or end lap and joint sealed with flamed torched pasted over full length [e] Applying one coat of hot blown bitumen 85/25 grade @ 1.2 Kg per Sqm. [f] Spread coarse sand over entire bitumen surface and than topping with and including 40mm thick brick tiles laid bedded, in cement sand mortar 1:6 & jointed and pointed with CM 1:3 complete all as specified and directed.
Supply only integral water proofing compound (powder) complete all as specified and directed.
M&L for Point wiring complete with PVC insulated unsheathed 1100 volts grade cable 1.5 Sqmm(nominal area) FRLS having stranded copper conductor single core drawn in and including 20mm dia rigid PVC conduit medium grade ISI marked including all conduit accessories for concealed pressed steel terminal box of required size not less than 1.6mm thick factory made duly painted inside and outside with two coats of black bituminous paint over and including a coat of red oxide primer with 3mm thick top cover of plastic laminated sheet/required colour for mounting switch socket/fan regulator etc including 1.5 Sqmm PVC insulated unsheathed cable FRLS having copper conductor as earth wire and connected earth dolly as required at the site complete for the following:- (i) One light or fan point controlled by one way switch
All as per item No. 78 above but for 3pin 5 Amp socket outlet on independent board using 2.5 Sqmm size cable.
M&L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 2.5 Sqmm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20 mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories for concealed wiring for one light/fan/bell/buzzer / exhaust fan point controlled by one, one way switch, including concealed pressed steel/PVC terminal box of required size not less than 1.0 mm thick factory made duly painted inside & outside with two coats of black bituminous paint over & including a coat of red oxide primer, with 3 mm thick top cover of plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 2.5 Sqmm FR type PVC insulated unsheathed cable solid copper conductor as continuous earth wire and connected to earth dolly as required at site& including chases cutting & making good disturbed surface & applying finishes to match existing surface complete all as specified and directed.
S&F switch socket combination 2 in 1, 6 pin 16Amps multipurpose type 240 volts complete all as specified and directed.
S&F switch piano flush button single pole one way 6 Amps, 240 volts complete all as specified and directed.
S&F socket flush type 5 pin 5 Amps with shutter complete all as specified and directed.
S&F ceiling rose surface Bakelite 65x25mm three terminals 240 volts complete all as specified and directed.
M&L sub main wiring with three single core PVC insulated & unsheathed cable 4.0 Sqmm (nominal area) FRLS type having multi-stranded copper conductor (phase, Earth & Neutral) drawn in and including rigid PVC conduit 'medium grade' ISI marked (not less than 20 mm dia) including all conduit accessories for concealed wiring, earth wire connected to common earth as per IS & cutting chasing for conduit & sinking for boxes & making good to walls disturbed surface & applying finishes to match existing surface complete all as specified and directed. NOTE : Three runs of 4.0 Sqmm and PVC conduit shall be measured as a one unit length.
M&L for sheet metal enclosure (Distribution board), factory made, Double door,4ways, single pole and neutral (SPN) with 200 Amps rated bus bar for housing MCBs/isolators complete including provn of blanking plate for unused ways complete all as specified and directed.
S & F MCB SP, 6 to 40 Amps single pole 230 volts,10 KA complete all as specified and directed.
S&F MCB SPN 40 Amps, 230 volts complete all as specified and directed.
M&L for fixing of pendent holder/lamp holder, ordinary/ bracket/angular type with insulated body , cord grip pattern complete all as specified and directed.
S&F LED retrofit lamp of capacity 12/15 watt, suitable for B-22 type holder base, heat sink Day light white complete all as specified and directed.
S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size and required length from ceiling rose including connection complete all as specified and directed.
S&F building security/street LED light fitting 35 watt IP-65 protection pressure die cast alluminium body ,heat resistant glass ,including driver and making necessary electric connection with 2.5 sqmm twin core copper wire 1.5m long, fixed on including GI pipe medium grade of suitable size bracket complete all as specified and directed.
S&F heavy duty high speed copper wound exhaust fan,300mm sweep , single phase 240 Volts with louver shutters and all accessories complete all as specified and directed.
Supply, laying and testing XLPE cable, PVC Insulated ,screened, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 2 core complete all as specified and directed. Note: Excavation & earth work, sand cushioning & Bricks shall be measured & paid separately under respective item
All as per item No. 94 above but XLPE cable of size 10 Sqmm , 2 core
All as per item No. 94 above but XLPE cable of size 10 Sqmm , 4 core
All as per item No. 94 above but XLPE cable of size 25 Sqmm , 3.5 core
M&L for sand cushioning with dry local sand for cable protecting under ground cable (8 cm before laying the cable and 15 cm after laying the cable) in trenches including punning the sand up to 18 cm thick and consolidated complete all as specified and directed. Note : Punned thickness 18 cm shall be measured only.
Supply and laying dry well burnt locally available brick sub class 'B' old size bricks laid flat with width equal to the length of whole bricks over cable as cable protection complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below GL with top edge of plate not less than 1.50 m below normal ground level) connected to galvanised earth lead wire 4.0 mm dia (7.5m) as means of bolts, nuts, check nuts and washer besides brazing at all joints as shown on drawings and including excavation, earth work, GI pipe (ISI mark) light grade 15 mm bore for protection of GI wire from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt, PCC 1:3:6, type C-1(using 20 mm graded crushed stone aggregate ) chamber and mild steel angle iron frame 40 x 40 x 3 mm and 40 mm thick pre-cast RCC cover 1:2:4 , type B-1(using 20 mm graded crushed stone aggregate ) reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade(ISI marked) for watering all as shown in electrical plate No 3 of SSR Part-I and connected to earth test point including testing of earthing & dismantling /taking down existing old / unserviceable earthing complete all as specified and directed. (Note:- The rates quoted shall also deemed to include the cost of Earth test point and earth wire and protection pipe up to 7.5 meter beyond the earth plates electrode.)
M&L for boring hole for passing cable through / insertion of 40/50 mm dia GI pipe under PCC road/ taxi track/ runway/ hard standing up to the depth 450mm to 1200 mm complete all as specified and directed. NOTES :- (i) Cost of equipment, tools & plants, material required for boring shall be deemed to be included in unit quoted rates above. (ii) GI pipe shall be measured and paid separately.
S&F for 40 mm dia GI pipe 'light grade' ISI marked including fittings such as bends, tees, sockets etc fixed on wall/pole or laid in trenches under road crossing/hard standing complete all as specified and directed. NOTE : Excavation and earth work shall be measured & paid separately.
All as per item No. 102 above but 50 mm dia GI pipe
M&L for Bus bar box/feeder pillar box made out of 3 mm thick CRCA /powder coated steel sheet, having 4 Nos. aluminium bus bar of rating 200 Amp mounted on insulator, 01 x MCCB 4 pole 63 Amp 415 volts with thermal magnetic release, breaking capacity 25 KA, as incomer and suitable fixing arrangement like flat iron clamp of size 25mm x 3mm with hinged cover & locking arrangement including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron of size 40 X 40 X 6 mm welded on all the four corner embedded in PCC 1:2:4 (using 20 mm graded stone aggregate), painted with two coat of synthetic enamel paint over a coat of red oxide primer outdoor type, complete all as specified and directed.
M&L for sheet metal enclosure (DBs), factory made, Double door, 6 ways, single pole and neutral (SPN) with 200 Amps rated bus bar for housing MCBs/isolators complete including provn of blanking plate for unused ways complete all as specified and directed.
S&F LED bldg security light 45 Watt complete with and including Medium grade GI pipe 40mm dia as service bracket bend to shape with clamp/nut bolts as required complete all as specified and directed.
GAYDIN CONSTRUCTIONS
M/S Akhilesh Enterprises
M/S DEEKSHA CONSTRUCTION
GANGETIC DOLPHIN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .