Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹6.3 L+₹95,300 (17.8%)Rejected-Finance | L2 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | Rudra Construction L2 | SLB Enterprises L1 |
|---|---|---|---|---|---|
| 1.00 | Disconnecting electrical wire from ceiling rose, taking down ceiling fan of any type/size and make, removing substances from bearing, bush by using kerosene oil, carrying out fresh lubrication using grease and to make the ceiling fan noise free for smooth functioning (including replacement of worn-out / unserviceable like capacitor, connector, canopy, bearing, down road, PVC cable etc) assembling the repaired ceiling fan including testing hanging the ceiling fan as its own position, connection with point wiring complete all as directed by Engineer-in-Charge.
(NOTE : Spare parts to be replaced shall be measured and paid separately., as supply only items was labour element involves for replacement of spare parts shall deemed to be included in the unit rate quoted by the tenderer). | 400 | Each Job | 400 ₹1,60,000 | 300 ₹1,20,000 Lowest |
| 2.00 | All as per item No. 1 here in before but for exhaust fan 300 mm/380 mm sweep. | 70 | Each Job | 400 ₹28,000 | 300 ₹21,000 Lowest |
| 3.00 | All as per item No. 1 here in before but for exhaust fan 450 mm sweep. | 25 | Each Job | 400 ₹10,000 | 300 ₹7,500 Lowest |
| 4.00 | All as per item No. 1 here in before but for PVC Ventilating fan 200 mm sweep. | 60 | Each Job | 400 ₹24,000 | 300 ₹18,000 Lowest |
| 5.00 | Removing of burnt out fan winding and rewinding of the of starter with suitable size of copper enamelled wire,(weight of copper coil shall be same as dismantled fan) of ceiling Fan of any make and size 1200 / 1400 mm sweep of existing gauge to obtain the specified and satisfactory RPM as per manufacturers specification, including replacement of all insulation materials, varnishing heating, drying, assembling of stator & rotor etc testing complete all as directed by Engineer-in-Charge. | 280 | Each Job | 400 ₹1,12,000 | 300 ₹84,000 Lowest |
| 6.00 | All as per item No. 5 above but for exhaust fan of any make / type and size 300 mm/380mm sweep. | 40 | Each Job | 300 ₹12,000 Lowest | 300 ₹12,000 Lowest |
| 7.00 | All as per item No.5 above but for wall mounted fan of any make/type and of size up to 400 mm sweep. | 10 | Each Job | 300 ₹3,000 Lowest | 300 ₹3,000 Lowest |
| 8.00 | All as per item No. 5 here in before but for PVC Ventilating fan 200 mm sweep. | 40 | Each Job | 300 ₹12,000 Lowest | 300 ₹12,000 Lowest |
| 9.00 | Supply only shaft for ceiling fan of size 1200mm | 20 | Each | 150 ₹3,000 Lowest | 150 ₹3,000 Lowest |
| 10.00 | Supply only ball bearing of any size and type suitable for any type / make / size of ceiling fan . | 300 | Each | 100 ₹30,000 Lowest | 100 ₹30,000 Lowest |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
30 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
Garrison Engineer Panaji Opposite of Kala Academy St Inez Road Goa 403001
REPAIR AND SERVICING OF GEYSERS CEILINGS EXHAUST AND WALL FANS INCL REPLACEMENT OF FAN MOTOR AT ALTINHO BAMBOLIM AND OTHER MINOR UNITS UNDER GE PANAJI
2025_MES_709930_2
8220/E8
Open Tender
Civil Works
Item Rate
180 days
GE PANAJI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE PANAJI
₹10,000
Yes
4 Oct 2025
2 Jul 2025
6 Aug 2025
2 Jul 2025
30 Jul 2025
16 Jul 2025
2 Jul 2025 - 9 Jul 2025
Amount
Disconnecting electrical wire from ceiling rose, taking down ceiling fan of any type/size and make, removing substances from bearing, bush by using kerosene oil, carrying out fresh lubrication using grease and to make the ceiling fan noise free for smooth functioning (including replacement of worn-out / unserviceable like capacitor, connector, canopy, bearing, down road, PVC cable etc) assembling the repaired ceiling fan including testing hanging the ceiling fan as its own position, connection with point wiring complete all as directed by Engineer-in-Charge. (NOTE : Spare parts to be replaced shall be measured and paid separately., as supply only items was labour element involves for replacement of spare parts shall deemed to be included in the unit rate quoted by the tenderer).
All as per item No. 1 here in before but for exhaust fan 300 mm/380 mm sweep.
All as per item No. 1 here in before but for exhaust fan 450 mm sweep.
All as per item No. 1 here in before but for PVC Ventilating fan 200 mm sweep.
Removing of burnt out fan winding and rewinding of the of starter with suitable size of copper enamelled wire,(weight of copper coil shall be same as dismantled fan) of ceiling Fan of any make and size 1200 / 1400 mm sweep of existing gauge to obtain the specified and satisfactory RPM as per manufacturers specification, including replacement of all insulation materials, varnishing heating, drying, assembling of stator & rotor etc testing complete all as directed by Engineer-in-Charge.
All as per item No. 5 above but for exhaust fan of any make / type and size 300 mm/380mm sweep.
All as per item No.5 above but for wall mounted fan of any make/type and of size up to 400 mm sweep.
All as per item No. 5 here in before but for PVC Ventilating fan 200 mm sweep.
Supply only shaft for ceiling fan of size 1200mm
Supply only ball bearing of any size and type suitable for any type / make / size of ceiling fan .
All as per item No.10 above but for exhaust fan of any type/make and size (300 /380 mm sweep) .
Supply only capacitor 230 Volts AC 50 HZ and rated capacity 2.5 MFD for ceiling fan.
Supply only capacitor 230V AC 50 HZ and rated capacity 3.15 MFD for exhaust fan.
S&F in repairs MS down rod 'medium grade' 15mm bore of suitable size(upto 1.2 meter lenth as required at site) with making split holes, cut or thread at both end of pipe as required for hanging of ceiling fan including gromet/ reel type rubber pad with clamp & bolts, nuts and washers including two coats of synthetic enamel white paint over one coat of primer all as directed
Supply only 'U' shape shakle clamp asssembly incl checknut , bolt, screws, washer, lock nut, rubber, reel etc and connecting complete all as specified
S&F in repairs louvers shutter made of MS sheet metal 1.2mm thick for square base and 0.8mm thick for flaps confirming of mounting edges frames made of MS Flat of size 25mmx3mm including heavy duty rust proof passivated bolts, of size 50mm long 8mm dia to be fixed on wall after drilling and duly painted by two coats of synthetic enamelled paint (spray painting) over a coat of primer for exhaust fans up to size 380 mm sweep.
S&F in repairs louvers shutter made of MS sheet metal 1.2mm thick for square base and 0.8mm thick for flaps confirming of mounting edges frames made of MS Flat of size 25mmx3mm including heavy duty rust proof passivated bolts, of size 50mm long 8mm dia to be fixed on wall after drilling and duly painted by two coats of synthetic enamelled paint (spray painting) over a coat of primer for exhaust fans up to size 300 mm sweep.
Supply only Metallic Fan Blade suitable for Exhaust fan of size 300 mm sweep all as directed.
Supply only Metallic Fan Blade suitable for Exhaust fan of size 450 mm sweep all as directed.
S&F in repairs of Metallic Fan Blades suitable for Ceiling fans of size 1200 mm sweep all as directed.
Taking out unserviceable geyser of any make and capacity for necessary repair/replacement including refixing the same in original position after repair including one coat of white synthetic enamel paint including preparation of old surface complete all as specified. (NOTE : spare parts shall be paid separately under supply only rate)
Supply only 15 mm size CP Brass inlet and outlet assembly complete with rubber gasket, nuts, bolts and washers suitable for housing heating elements, thermostat etc. for 25 litre capacity storage type water heater complete all as specified and directed. Make - Dasspass, Ditz, Racold, Havells
Supply only PVC connection pipes inner wiremesh type 15mm size with PTMT nuts of length 450mm hot and cold with both ended brass flare nuts for geyser connection. (Make:Prayag/Marc/Jaquar)
Supply only Thermostat, suitable for any make & type of geyser 50/25 litres capacity horizontal or vertcal type comple all as specified and directed with auto cut for setting temperature 0- 90C.
Supply only gun metal safety valve all as per existing size and shape of geyser installed at Location.
Supply only Copper sheathed and nickel plated heating element of capacity 1.5 KW with gasket(ISI marked) round /cup type suitable for horizontal or vertical type water storage water heater(geysers) complete all as specified and directed make: Dasspass, ditz, recold, empire, Havells/veenus
All as per Item No.26 above but of capacity 2.0 KW.
S&F Anchor bolts of sizes 8.0 mmX100 mm for installations of Geyser of any make and capacity.
S&F Anchor bolts of sizes 10 mmx100 mm for installations of Geyser of any make and capacity.
Rudra Construction (BID ID -3369304)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .