Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC | ₹1.9 Cr | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹2.1 CrRejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹2.1 Cr | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹2.1 CrRejected-Finance | ₹2.1 Cr | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹2.3 CrRejected-Finance | ₹2.3 Cr | L4 | Rejected-Finance Other than lowest |
| 5 | Rejected-Technical HOUSE NO 49 SECTOR 28 FARIDABAD 121008 HR | FARIDABAD | FARIDABAD | HARYANA | 121008 | - | - | Rejected-Technical Not Recommended, Enlistment of firm valid upto 31 Dec 2025, no renewal document enclosed. |
| Sl No | Description | Qty | Unit | M/S ANIL KUMAR L2 | M/S MOHD KARIM L3 | M/S Chozang Namgial L1 | MS MOHD SHAREF L4 |
|---|---|---|---|---|---|---|---|
| 0.00NOTE: Schedule ‘A’ Part - I to Part -XIV are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. | |||||||
| 1.00 | Total amount of Sch 'A' Part - I (BUILDING Works) | 1 | LUMP SUM | 1,53,50,000 ₹1.5 Cr | 1,54,65,876 ₹1.5 Cr | 1,29,00,000 ₹1.3 Cr | 1,68,00,000 ₹1.7 Cr |
| 2.00 | Total amount of Sch 'A' Part - II (DEMOLITION OF BLDG) | 1 | LUMP SUM | 1,00,000 ₹1 L | 80,000 ₹80,000 | 80,000 ₹80,000 | 60,000 ₹60,000 |
| 3.00 | Total amount of Sch 'A' Part - III (SITE CLEARANCE & EART WORKS) | 1 | LUMP SUM | 2,50,000 ₹2.5 L | 3,00,000 ₹3 L | 3,20,000 ₹3.2 L | 2,00,000 ₹2 L |
| 4.00 | Total amount of Sch ‘A’ Part - IV (INTERNAL ELEC SUPPLY) | 1 | LUMP SUM | 3,00,000 ₹3 L | 5,14,880 ₹5.1 L | 3,50,000 ₹3.5 L | 4,20,000 ₹4.2 L |
| 5.00 | Total amount of Sch ‘A’ Part - V (INTERNAL WATER SUPPLY) | 1 | LUMP SUM | 1,50,000 ₹1.5 L | 1,52,136 ₹1.5 L | 90,000 ₹90,000 | 1,50,000 ₹1.5 L |
| 6.00 | Total amount of Sch ‘A’ Part - VI (ROAD,,PATH & HARD STANDING WORKS) | 1 | LUMP SUM | 1,50,000 ₹1.5 L | 1,46,447 ₹1.5 L | 85,000 ₹85,000 | 1,00,000 ₹1 L |
| 7.00 | Total amount of Sch ‘A’ Part - VII (SEWAGE DISPOSAL) | 1 | LUMP SUM | 50,000 ₹50,000 | 79,052 ₹79,052 | 38,000 ₹38,000 | 50,000 ₹50,000 |
| 8.00 | Total amount of Sch ‘A’ Part - VIII (HOT WATER SUPPLY) | 1 | LUMP SUM | 3,25,000 ₹3.3 L | 3,47,903 ₹3.5 L | 3,20,000 ₹3.2 L | 3,50,000 ₹3.5 L |
| 9.00 | Total amount of Sch ‘A’ Part - IX
( EXTRNAL WATER SUPPLY WORKS) | 1 | LUMP SUM | 2,00,000 ₹2 L | 2,14,963 ₹2.1 L | 1,40,000 ₹1.4 L | 2,50,000 ₹2.5 L |
Updated dates
Tender Value
₹2.0 Cr
EMD Value
₹2.7 L
Closing Date
11 Apr 2026, 6:00 pmClosed
Chief Engineer
HQ Chief Engineer PIN 194101 c/o56 APO
CONSTR OF COOK HOUSE WITH DINING HALL AT PARTAP PUR UNDER GE 873 EWS
2026_MES_753259_1
180138/E8
Open Tender
Civil Works
700 days
Partapur, leh
Please refer tender documents
8 documents required · 8 mandatory
₹1,000
GE 873 EWS
₹2.7 L
16 Jun 2026
18 Feb 2026
14 Apr 2026
18 Feb 2026
11 Apr 2026
28 Mar 2026
NOTE: Schedule ‘A’ Part - I to Part -XIV are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Total amount of Sch 'A' Part - I (BUILDING Works)
Total amount of Sch 'A' Part - II (DEMOLITION OF BLDG)
Total amount of Sch 'A' Part - III (SITE CLEARANCE & EART WORKS)
Total amount of Sch ‘A’ Part - IV (INTERNAL ELEC SUPPLY)
Total amount of Sch ‘A’ Part - V (INTERNAL WATER SUPPLY)
Total amount of Sch ‘A’ Part - VI (ROAD,,PATH & HARD STANDING WORKS)
Total amount of Sch ‘A’ Part - VII (SEWAGE DISPOSAL)
Total amount of Sch ‘A’ Part - VIII (HOT WATER SUPPLY)
Total amount of Sch ‘A’ Part - IX ( EXTRNAL WATER SUPPLY WORKS)
Total amount of Sch ‘A’ Part - X ( EXTRNAL ELECTRIC SUPPLY WORKS)
SCH 'A PART - XI (Miscellaneous B/R and E/M works for Sch 'A' Part-II to Part-XVI) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 5 signifies this fact only
S & F in of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting complete all as specified and directed.
S & F in of wall mounted LED Tube light fitting 1 x 10W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting complete all as specified and directed.
S & F MCB TPN 63 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity complete all as specified
S & F of MCB SPN, 240 volt, 32 Amps complete all as specified.
S & F of MCB SP, 240 volt, 6 to 32 Amps complete all as specified.
Supply & fixing LED street Light fitting 20 Watt made of pressure die cast housing, with toughened glass and high power LEDs with with IP65 protection complete with 40 mm GI pipe bracket not less than 1.2 mtr length and bent to a shape incl 02 Nos 25x6 mm flat clamps with nut bolt and washers complete with all fixing acessories as reqd at site for fixation on wall and connection with 3 core flexible copper suitable size wire as specified and directed
M&L for RCC septic tank designed to carry seage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M30 Design Mix in walls, Base Slab, Baffle walls and Roof slab including beams etc with vent shaft, manhole opening with cover connection etc, complete with effective depth of 1.5 mtr and overall of 3 mtr for 10 Users complete
Construction of soakage well 3.00m internal dia and 3.00m effective depth incl excavation in any type of soil , foundation in PCC 1:3:6 type C-1 ( using 20mm graded crushed stone aggregates ), PCC Block honeycomb/ solid masonry in cement mortar (1:4) RCC M-30 design Mix cover Slab filled with stone boulders including intersepting chamber screen chamber and disposal of soil complete all as specified and shown on drawings.
M&L for Elestometric Nytral rubber insulation to PP-R pipes suitable for 25mm outer dia 22/19mm thick with chiken wire mesh wire netting 25mm gauge, 20mm mesh with 3mm aluminium foil including jointing and fixing material such as solvent adhesive SR-998 complete all as specified and directed by Engr-in-Charge.
M&L for Elestometric Nytral rubber insulation to PP-R pipes suitable for 40mm outer dia 22/19mm thick with chiken wire mesh wire netting 25mm gauge, 20mm mesh with 3mm aluminium foil including jointing and fixing material such as solvent adhesive SR-998 complete all as specified and directed by Engr-in-Charge.
Supply ,Install Testing & Commissioning of self supporting totally enclosed double door at front, LT feeder piller compartmentalised design, dust and varmin proof of size 600 mm(Height) x 600 mm(Length) x 450 mm(Width) suitable for 440 Volt 3 phase 4 wire system made out of 3.15 mm thick CRCA sheet and built upon regid frame work having front and rear hinged doors with neoprence rubber gasket including danger plate, earthing strip point and, ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size of Zinc/Cromium plated and nuts, bolts ;and washers etc. The pannel shall be synthetic enamelled painted and the control circuit diagram shall be with colour code solid conductor copper 1.5 sqmm cable for easy identification including incomming/outgoing cable holes at the bottom, complete after taking down the old unserviceable one. The Panel shall be emmbeded with 75 x 6 mm MS Angle Iron frame and to be grouted with PCC foundation (1:2:4 ) type B2 upto a height of 50 cm from normal ground level complete all as specified and directed by Engr in charge and comprising of the following.
(a) Aluminium bus bar 200 amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. (b) MCCB of , 63 A with breaking capacity of 35 KA, OUT GOING:- (b) MCB of TPN, 63 A ,with breaking capacity of 25 KA, INDICATING DEVICES (a) LED Indicating lamps for Main Supply indicating R', Y' B' - 01 Set of 3 (b) Digital Voltmeter (Make AE/L&T) - 01 No (c)Current Transformer having Ratio 400/5, 15 VA - 01 Set of 3 (d) Digital Ammeter ( Make(AE/L&T) - 01 N0 (e) Front operated ON Load changeover switch 415V, 4 Pole of capacity 63 Amp - 01 Nos
Supply, install, test and commissioning of 40 KVA/ 32 KW DG set diesel engine driven Generating set with alternator out put Voltage 415 Volts +/- 1% at set value of 415 V at a frequency 50HZ +/- 0.5%, suitable for prime duty with STD control panel outdoor type IP-54 consisting of AMF feature to be erected, (NTP for suitable for installing at Minniebay Port Blair, all mounted in acoustic enclosure and Control panel as per manufacturer's design and specification confirming to latest norms of CPCB complete with the following and connected accessories and depositing to MES store yard with necessary T&P complete :-
(xiv) The details specifications appended below :- (I) ENGINE (a) General: Suitable four stroke compressed ignition, radiator water cooled,Turbocharged aspiration, continuous duty with 10% overload capacity for 1 hour in 12 hours continuous running, with 40 to 50°C intake air temperature, latest CPCB Euro emission engine ,turbocharged four stroke engine developing minimum 60 BHP @ 1500 RPM under NTP conditions, coupled to alternator mounted on Channel Iron base frame with external floor mounted fuel tank of minimum 500 Ltrs capacity with fuel gauge and connected fuel pipeline from main fuel tank to DG fuel tank complete .The prime mover provided should be as per IS specifications. (b) Air intake system : Should comprise of dry type intake air filter mounted on engine, one in number vacuum indicator mounted on intake piping. (c ) Exhaust System: Should comprise of one exhaust manifold, dry type, mounted on engine, one exhaust hospital type silencer which should be positioned in such a way that the exhaust gas is not sucked by the fan on the radiator/heat exchanger, thereby affecting the cooling system. The silencer should cater to the noise level tolerance prescribed in the relevant IS/BS. The silencer should be provided with flaps with a provision so that it will open only when the generator is running. The complete exhaust system shall be properly supported so that entire lot of the exhaust system shall not fall on the DG Set.
(d) Fuel System: Should comprise of disposal type element fuel filter, pressure type fuel pump mounted on engine, non return check valve in fuel supply and drain lines, wire braided hose between filter and pump, fuel system with suitable capacity electronic governor and engine mounted actuator. The fuel tank must have proper locking arrangement with level indicator and to be fixed seperately / externally. (e) Cooling System: Should comprise of radiator and connected pipeline complete, hospital type silencer and tested for 50°C ambient temperature with 7 PSI pressure cap mounted on base rail. The thermostat installed in the engine coolant outlet, fresh water pump mounted on engine, fan and fan hub mounted on engine. A reservoir of 50% of radiator capacity to replenish coolant by gravity (as and when required) is also to be provided. (f) Lubricating System: Should comprise of lubricating oil sump mounted on engine, gear driven lub oil pump mounted on engine, lubricating oil cooler-fresh water cooled integral with engine cool out circuit mounted on engine, oil filter lubricating with cap and lubricating oil dip stick for oil level check mounted on engine. The system should be capable of feeding lube oil to the main end & large end bearings, cam shaft, valve rocker gear and all moving parts. (g) Starting System: Should comprise of suitable voltage DC electrical starter mounted on engine, with suitable maintenance free battery of capacity 12 V DC - 02 Nos with suitable AH to be mounted in trays (having rubber insulation) on the main frame. It should have the provision to charge the battery from external sources during static condition and while running of the generator. (h) AC Generator : The generator shall be horizontal and foot mounted,40 KVA, 415 Volts, 3 phase, 4 wire, 0.8 PF, 50 HZ, self excited, self regulated, brushless AC generator, suitable for voltage regulation + 1% , an ambient temperature of 40 to 50° C as per OEM design with IP-23 enclosure class H insulation and temperature rise limited to class H as per following technical details:- (i) Type, Brush less AC Generators and space heater as per OEM design (ii) Output rating 40KVA (iii) Output Voltage: 415 ± 1% under all loading conditions and with maximum voltage Dip at full load 0.8 PF shall be < 19% as per OEM design. (iv) Output frequency 50Hz ±0.5% up to 0.8 lagging. (v) No of Phases: 3 phase with 01 Neutral (4 wire) (vi) Mounting : Horizontal foot mounted.
S&F for stand Alone Heater with heating capacity of 25000 Kcal/Hr with 2 HP blower motor and complete accessories.
(a) No of Passes - 04 Passes (b) Hot Air Temp-80 Degree C (c) Process Air Flow at STP (1.2 KG/Cum air density)-80 Degree C (d) Thermal Efficienty-90% (e) Fuel Type-Diesel/Kerosene (f) Max Fuel Consumption (HSD) -1.2 kg/hr(on full load however fuel consumption will vary depending on process temperature and air requirement) (g) Electricity Supply - 415+6%, 50Hz+3%, 3 Phase, 4 wire (h) Fuel filter and tank- Provided, 10 Ltr (j) Burner- burmer fitted with imported (k) Blower Fan- Double inlet backward curved centrifugal fan suitable for high pressure upto 80mmwc (l) Blower Motor-FHP, Standard make (ABB/Siemens/Equivalent) for up to 25000 Kacal/hrs size (m) Drive-Belt driven through taper lock pulleys and belt to adjust RPM as per process air flow and pressure requirements (n) Temperature control- Automatic through digital temperature controller. (o) Control Panel-Pre-wired powder coated control panel with user friendly audio-visual controls,safeties, interlocks, MCB, overload relays, timers and alarm hooter (p) Blower fan guard (q) Outer Body- Fabricated out of mild steel duly insulated from inside and 1 Mtr exhaust pipe of aluminium sheet 1.6 mm
S&F for stand Alone Heater with heating capacity of 50000 Kcal/Hr with 5 HP blower motor and complete accessories
(a) No of Passes - 04 Passes (b) Hot Air Temp-80 Degree C (c) Process Air Flow at STP (1.2 KG/Cum air density)-80 Degree C (d) Thermal Efficienty-90% (e) Fuel Type-Diesel/Kerosene (f) Max Fuel Consumption (HSD) -1.2 kg/hr(on full load however fuel consumption will vary depending on process temperature and air requirement) (g) Electricity Supply - 415+6%, 50Hz+3%, 3 Phase, 4 wire (h) Fuel filter and tank- Provided, 10 Ltr (j) Burner- burmer fitted with imported (k) Blower Fan- Double inlet backward curved centrifugal fan suitable for high pressure upto 80mmwc (l) Blower Motor-FHP, Standard make (ABB/Siemens/Equivalent) for up to 50000 Kacal/hrs size (m) Drive-Belt driven through taper lock pulleys and belt to adjust RPM as per process air flow and pressure requirement (n) Temperature control- Automatic through digital temperature controller. (o) Control Panel-Pre-wired powder coated control panel with user friendly audio-visual controls,safeties, interlocks, MCB, overload relays, timers and alarm hooter (p) Blower fan guard (q) Outer Body- Fabricated out of mild steel duly insulated from inside and 1 Mtr exhaust pipe of aluminium sheet 1.6 mm
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.89 MB
CompleteTender180138.pdf
Tender Documents • 3.34 MB
BOQ_843697.xls
BOQ • 0.37 MB
AllDrgs.pdf
Additional Documents • 11.08 MB
Download all tender documents and submit your bid