Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC | L1 | Accepted-AOC l1 | |
| 2 | L2₹41.7 L+₹1.3 L (3.19%)Rejected-Finance HOUSE NO 254P SECTOR 6 ROHTAK OPPOSITE RAJIV GANDHI STADIUM VPO MAKRUALI KALAN 124001 | ROHTAK | ROHTAK | HARYANA | 124001 | L2 | Rejected-Finance L2 |
Tender Value
₹35.1 L
EMD Value
₹71,000
Closing Date
18 Jul 2020, 1:00 pmClosed
Vishal Garg
EE-5
Construction of Sump along with Pumping machinery, Rising main, Reflex Valve etc. for disposal of Strom Water into existing SWD near Main Gate of Essal Tower at Meharauli road for the disposal of Strom Water coming towards Meharauli road near Ga
2020_HRY_134767_1
EE-V/MCG/2020/19980 dated 08.07.2020
Open Tender
Civil Works
Works
90 days
work
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Commissioner, MCG
₹71,000
16 Jul 2021
8 Jul 2020
20 Jul 2020
8 Jul 2020
18 Jul 2020
8 Jul 2020
Amount
Construction of Sump along with Pumping machinery, Rising main, Reflex Valve etc. for disposal of Strom Water into existing SWD near Main Gate of Essal Tower at Meharauli road for the disposal of Strom Water coming towards Meharauli road & near Gate at main road for Sushant Lok-1 at Meharauli road for the disposal of Strom Water coming from Blok -A Sushant Lok-1 towards Meharauli road. , under Municipal Corporation Gurugram
Providing at installation of . Non Clog sewerage Submersible pumping sets complete as given below at PS Supplying of Non Clog sewerage submersible pumps.Model JSE-6, single stage, side delivery volume casing type, Pump efficiency BKW, Motror efficiency , rating 25.00/18.6/1450 RPM, "f" CLASS , Air fiill, ball bearing with 40000 Hrs life,Grease lubricated,solid Handling , Pump delivery size 150-250 mm,Type of motor TEWC, pump casing C.I.F.G.260, Implar 3-3-16, S.S- 410 shaft,SS-316, 415 Volts, 50 Hr, A.C. suppply, Star Delta, Thrmister & moisture sencer,IP-68/DUTY:81, Cable 10 m of required size, Auto coupling with intergal C.I.bend & ss Hardware-1 set, 50 mm Galvanised guide pipe, M.S.Galvanised lifting chain with shackle 15 mtr length complete as per IS specification.( Non Clog Submersible sewage pumps of 185 m3/Hr (DWF) with Head 12.50 Mtr. all other accessories complete in all respects.2400LPM)150 m3/hr 12.50 m Head
Supplying and fixing following DI/C.I. D/F pipe, CI specials, sluice valves with wheel, non return valves with G.M. Flap including cost of jointing materials, excavation, laying refilling including making adequate supports of masonry / concrete / steel for delivery pipe from submersible pump set up to 1.5 meter outside the outer wall of pump chamber as per specification given in Schedule No II.The ACB, MCCB, contractors, ammeter etc. shall be of suitable rating as per the load requirement.All the power connections should be with solid copper bus bar of suitable rating. .A) Detail of pipe and specialsa) C.I. D/F Pipesiii) 200 mm i/d D/F Pipes
b) bell mouth i) 200 mm i/d
c) CI D/F bends, reducers, tapers, tees, tail piece, blank flange etc. up to 150 mm i/d and 300 mm i/d
Supply and fixing of SS 304 manual screens of size 600 mm x600 mm with 20mm opening Center to Center and size of each bar 10mm x 20mm thick including cost of fitting complete Construction of Humps on Two side entry of Essel Tower for to avoid entry of out side water. Gate No.1(30 Mtr wide) & Gate No.3(10 Mtr wide)
Providing, Laying and consolidation of stone metal,wearing coat, to water-bound-macadam specification, including making side dowles,carrying the metal from stacks and spreading to templates, screening and spreading the binding material, and consolidating the stone metal and blinding material, to proper camber, with road roller, excluding the cost of templates barriers and lighting arrangement(0.76/2=0.38)
Providing & laying bituminous macadam,(BM) on road with coarse aggregates and bitumen mixed andheated with a mechanical mixer, in the proportion as per design for criteria specified carriage of of the premixed material from plant site to site of work and laying the same, with paver and rolling it, with road roller to achieve specified value of compaction, strength and surface accuracy complete including the cost of establishment and setting up field laboratory, for quality control, plant transporation,lighting arrangements, sign boards and chowkidar etc. complete but excluding the cost of tack coat and seal coat (a) with lead upto 1 km.(0.150/2=0.075)
Providing and laying bituminous concrete (BC) with 100-120 TPH batch type HMP producing and average output of 75 tonne per hour using crushed aggregates of specified grading , premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tendom rollers to achieve the desired compaction as per MORTH & H specifications Clause - 509 complete in all respect.(0.150)
Bidder Name
Amount
ANIL KUMAR
AVL Engineering Services Pvt. Ltd.
ANIL KUMAR
ANIL KUMAR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .