| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹38.4 L+₹1.8 L (4.99%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹40.7 L+₹4.2 L (11.4%)Rejected-Finance GANDHI CHOWK MANIPURA JAISALMER RAJ 345001 | JAISALMER | JAISALMER | RAJASTHAN | 345001 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹41.5 L+₹4.9 L (13.5%)Rejected-Finance TOTA RAM KI DHANI BABAR MAGRA JAISALMER RAJ 345001 | JAISALMER | JAISALMER | RAJASTHAN | 345001 | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹47.3 L+₹10.7 L (29.3%)Rejected-Finance JAISALMER | BARMER | RAJASTHAN | 344001 | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹38.8 L
EMD Value
₹78,000
Closing Date
18 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (A) Jaisalmer
HQ CWE ARMY JAISALMER 345001 RAJASTHAN
PROVN OF 3 x SINGLE JCOs ACCOMMODATION FOR 199 PET PL ASC AT MIL STN JAISALMER UNDER GE(A) JAISALMER
2025_MES_708625_1
84314/C/E8
Open Tender
Civil Works
Item Rate
180 days
JAISALMER
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (A) Jaisalmer
₹78,000
Yes
30 Jul 2025
16 May 2025
20 Jun 2025
16 May 2025
18 Jun 2025
6 Jun 2025
16 May 2025 - 23 May 2025
Amount
B&R WORK Excavating in trenchs, n exc 1.5m wide and n exc 1.5m in depth; for foundation, laying of cable/pipe, or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Excavating in trenchs, n exc 1.5m wide and exc 1.5m but n exc 3.0m in depth; for foundation, laying of cable/pipe or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in in any type of soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil material to a distance n exc 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for hard core broken to stone or boulders gauge exc 63 mm and n. Exc. 100mm filling in under floors or pavings complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 (Type C2) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:4:8 (Type D2) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate) as in foundations, including rafts, footing foundation beams, plinth beam, base for coulm, etc basement slab under ream piles and mass complete all as specified and directed by Engineer-in-Charge.
M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate) as in Column, Pillars post and struts etc complete all as specified and directed by Engineer-in-Charge.
M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate) as in beams, cantilever, bressummers, lintel over 1.5m span etc complete all as specified and directed by Engineer-in-Charge.
M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate)e as on Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs andd in shelves and the like complete all as specified and directed by Engineer-in-Charge.
M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate) as for chajjas complete all as specified and directed by Engineer-in-Charge.
Formwork to sides of concrete foundation ,footing,base of column ,raft beams , sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter to rough finish surface of concrete flat complete all as specified and directed by Engineer-in-Charge.
Formwork to soffits of suspended slabs such as roof slabs ,floor slabs ,landing and similar work not exc 200mm thick (Horizontal or sloping) to rough finish surface of concrete flat. complete all as specified and directed by Engineer-in-Charge.
Formwork to soffits of floor or roof beams, beam haunching ,grider, bressumber, lintels,cantilever ,sleves including supports ,over hang etc also splay between floor and beams to rough finish surface of concrete flat. complete all as specified and directed by Engineer-in-Charge.
Formwork to sides of pillars, posts ,struts piers ,columns and stanchion to rough finish surface of concrete square ,rectangular or polygonal. complete all as specified and directed by Engineer-in-Charge.
Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed by Engineer-in-Charge.
Formwork to edges of finished surface of concrete flats ,treads, break in floors window cills, concrete railing , opening in concrete wall, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls , horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide to rough finish surface of concrete flat. complete all as specified and directed by Engineer-in-Charge.
M&L for TMT mild steel bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to complete all as specified and directed by Engineer-in-Charge.
M&L for TMT mild steel bars 6 to 8mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to complete all as specified and directed by Engineer-in-Charge.
All as per Item No. 20.00 here-in-before above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed by Engineer-in-Charge.
M&L for squared rubble walling Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with fly ash bricks modular brick size straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick cement plaster in CM 1:6 on fair faces of brick/concrete work surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5 mm tk on fair faces of concrete surface in ceiling in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick cement plaster in CM 1:4 on fair faces of brick/concrete work surfaces finished even and smooth without using extra cement including water proofing compound complete all as specified and directed. Note : water proofing compound will be measured and paid seperately under relevant item.
Supply only integral water proofing compound complete all as specified and directed by Engineer-in-Charge.
M&L for preparing of new plaster surface and applying three coat of white wash on newly plaster surface of wall complete all as specified and directed by Engineer-in-Charge.
M&L for preparing of newly plaster surface and applying three coat of white wash on newly plaster surface of ceiling complete all as specified and directed by Engineer-in-Charge.
M&L for preparing of newly plaster surfaces of wall and applying two coats of cement based paint over one coat of alkali resistant primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparing of newly plaster surfaces on wall and apppying of two coat of oil bound distemper over a coat of alkali primer over plastered surface of wall complete all as specified and directed by Engineer-in-Charge.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick PCC 1:3:6 type C2 using 20mm graded stone aggregate as in plinth protection, sub base of flooring and hard standing including providing contraction joints with wooden spacers complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in sub base of flooring and hard standing complete all as specified and directed by Engineer-in-Charge.
M&L for green marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and directed by Engineer-in-Charge.
M&L for non Skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15 mm thick in (1:6) for laying floor finishes like tiles etc complete all as specified and directed by Engineer-in-Charge.
M&L for non Skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm on vertical surfaces such as skirtings, dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing coat in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
M&L for non Skid coloured ceramic tiles 6 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15 mm thick in (1:6) for laying floor finishes like tiles etc complete all as specified and directed by Engineer-in-Charge.
M&L for Glazed coloured ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including Rendering 10 mm thick cement plaster in CM 1:4 for fixing vertical tiles complete all as specified and directed by Engineer-in-Charge.
M&L for Kota stone slab 16-22mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and backing coat 10mm thick in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for pressed steel frames of size 105x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. incl filling of hollow portion with complete all as specified and directed by Engineer-in-Charge.
M&L for pressed steel frames of size 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. incl filling of hollow portion with complete all as specified and directed by Engineer-in-Charge.
S&F Plain, framed, panelled shutters 35 mm thick in second class hard wood (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed by Engineer-in-Charge.
S&F glazed & skeleten shutters 35mm thick 2nd class Hardwood but divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, prepared to receive glass, gauze, etc, fitted with cut & mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part I Section 8 clause 8.24 (a) fitted to chowkhats complete all as specified and directed by Engineer-in-Charge.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet reinforced with M.S Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed by Engineer-in-Charge.
S&F Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C' channel heaving a PVC sheert strip of 20mm width suck inside with solvent cement for stiles and wood grain printed PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bbottom rail; Panelling of wood grain printed PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. complete all as specified and directed by Engineer-in-Charge.
S&F 150 mm aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge.
S&F 150mm Aluminium handles, cast type anodised complete all as specified and directed by Engineer-in-Charge.
S&F butt hinges, extruded alluminium,with mild steel hinge pin,bright polished and fixed, type 100mm size C-21 complete all as specified and directed by Engineer-in-Charge.
S&F Aluminium alloy, anodised, sliding door bolt 200mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed by Engineer-in-Charge.
S&F galvanized mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and directed by Engineer-in-Charge.
S&F Aluminium (Die cast) body Door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg and fixed complete all as specified and directed by Engineer-in-Charge.
S&F floor door stopper of aluminium alloy body 140mm long complete all as specified and directed by Engineer-in-Charge.
S&F steel windows with side hung shutters including projecting type hinge with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed by Engineer-in-Charge.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete with glazing bars, complete all as specified and directed by Engineer-in-Charge.
M&L for plain sheet glass plain 3mm thick ordinary quality and glazing with oil putty in square n. exc 0.5 Sqm in each pane complete all as specified and directed by Engineer-in-Charge.
M&L for pin headed/figured Sheet glass 4mm thick, ordinary quality and glazing with oil putty in square n.exc 0.5 sq. m in each pane, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of New or previously untreated wood and wood based surfaces of any description, .exc 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm dia medium grade galvanized water tubes with all fittings and fixed complete to wall & ceilings and laid in floor, roof top etc. complete all as specified and directed by Engineer-in-Charge.
All as per item No. 59.00 here-in-before above but 20mm dia bore
S&F vitreous china wash down water closet pedestal pattern including connecting to flush tank, including seat cover, flush down pipe of the same make as that of closet complete all as specified and directed by Engineer-in-Charge.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm bore Bib taps, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge.
S&F 10 ltrs capacity PVC low level flushing cistern with inlet, ball valve, float, handle including fitting and fixtures and providing connections to WC and flush pipe without any damage to the existing fittings, complete all as specified and directed by Engineer-in-Charge.
S&F Vitreous china wash basin pedestal type, white, flat back, size 550 X 400 mm excluding taps, chain and plug and porcelain stopper but including CP waste coupling & brackets and fixed complete all as specified and directed by Engineer-in-Charge.
S&F 600 mm long PVC connection pipe of 15mm bore with PTMT nut at both ends complete all as specified and directed by Engineer-in-Charge.
S&F soap dish, vitreous China white, approximate size 160x 160x90mm fixed to plugs with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge.
S&F swivel shower rose 125mm size with arm 195mm long with bend of 45 degree with flange of PTMT any colour complete all as specified and directed by Engineer-in-Charge.
S&F of harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed by Engineer-in-Charge.
S&F 20mm bore gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe with fittings and accessories, ISI marked and as per IS 14846 complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm dia Stop valves, cast copper alloy screwed presure, with crutch of butterfly handle, screwed both ends for iron pipe for unions and fixed but fancy type chromium plated with long shank and cup (concealed type) complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm dia Stop valves, cast copper alloy screwed presure, with crutch of butterfly handle, screwed both ends for iron pipe for unions and fixed but fancy type chromium plated complete all as specified and directed by Engineer-in-Charge.
S&F tubular towel rail, brass chromium plated 20 mm dia `D' type 60 cm long between flanges complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore PVC (SWR) single socketed in any length with rubber ring joints & fixed to walls or laid in floors complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore PVC (SWR) single socketed in any length with rubber ring joints & fixed to walls or laid in floors complete all as specified and directed by Engineer-in-Charge.
S&F 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) bends of 75mm bore setting & jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
All as per item No. 78.00 here-in-before above but 110mm bore.
S&F PVC (SWR) cowl of 75mm bore setting & jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) cowl of 110mm bore setting & jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
M&L for APP based polymeric membrane minmum weighing 3 Kg/Sqm and minmum 3 mm thick reinforced with polyster non wove fabric ( wt not less than 150 gms/sqm) including priming of surface by forced application including 15mm thick 1:3 CM screed bed with water proofing compound complete all as specified and directed by Engineer-in-Charge. Note : water proofing compound will be measured and paid seperately under relevant item.
M&L for Bitumen blown any grade, applied hot, two coats, to concrete surfaces at the rate of 1.5kg. per sq. m per coat complete all as specified and directed by Engineer-in-Charge.
M&L for rotational moulded polyethylene water storage tanks 500 litres capacity triple layered (White ) cylindrical vertical with closed top hoisted and 20mm ball valves high pressure with polythene float and flynut complete all as specified and directed by Engineer-in-Charge.
M&L for framed work as in doors or gates of angle Gde-Fe-290( Gde-E-165) or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
Surface dressing n exc 15 cm deep and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth for foundation, laying of cable/pipe, or for shafts, wells, cesspits, manholes pier holes etc not exceeding 10 sqm on plan and getting out in soft / disintegrated rock complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick as in soft/disintegrated rock complete all as specified and directed by Engineer-in-Charge.
Removing excavated material (rock) n. Exc. 50 mtr and depositibg where directed at a level n. Exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for Providing, cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating including necessary formwork complete all as specified and directed by Engineer-in-Charge.
M&L for 150 mm internal dia of reinforced cement concret drain pipe class NP-3 laid in tenches and jointedwith collarscomplete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate in concrete bedding to drain pipes including packing under, & haunching against the sides of pipes after they are laid & tested for 150 mm bore pipe complete all as specified and directed by Engineer-in-Charge.
M&L for On site Hume Pipe septic tank for 10 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for brick work in CM 1:4 plastering mixed with WPC incl RCC/CI manhole cover, cement pipe & Sludge chamber complete all as specified and directed by Engineer-in-Charge.
M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.20 M dia X 3.00 M deep complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in surface channels and drain complete all as specified and directed by Engineer-in-Charge.
Surface excavation not exc 30 cm deep and average 15 cm deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
M & L for 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded aggregate as in sub base to hardstanding/floor complete all as specified and directed by Engineer-in-Charge.
M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete including packing all around with PCC 1:2:4 complete all as specified and directed by Engineer-in-Charge.
M & L for 40 mm thick PCC 1:2:4 type B-1 using 20 mm graded aggregate as in damp proof coarse complete all as specified and directed by Engineer-in-Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc. complete all as specified and directed by Engineer-in-Charge.
M&L for providing precast cement concrete 1:2:4 type B-1 using 20 mm graded aggregate in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match but in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed by Engineer-in-Charge.
E&M WORK M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked with valid CML No. in and including medium grade, PVC concealed conduit of dia not less than 20mm and conduit accessories, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories) concealed in wall/roof/floor etc with mild steel/pressed steel sunken boxes (with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with modular cover and plate for fixing of modular switches, sockets etc including PVC insulated multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge for the following :- Note:- Modular switch and socket shall be measured and paid separately.
All as per Item No.103.00 here in before above but for One light point controlled by one way switch complete all as specified and directed by Engineer-in-Charge.
All as per Item No.103.00 here in before above but for One Ceiling Fan/Exhaust fan point controlled by one way switch complete all as specified and directed by Engineer-in-Charge.
All as per Item No.103.00 here in before above but for one socket outlet 3/2pin 5 amps point on the same board with other switches complete all as specified and directed by Engineer-in-Charge.
All as per Item No.103.00 here in before above but for point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed (FRLSH) cable 1100 volts grade and 2.5 Sqmm PVC insulated and unsheathed (FRLSH) cable 1100 volts grade with multi-stranded copper conductor as earth wire for 5/6 Amps multipurpose socket combination point on independent board complete all as specified and directed by Engineer-in-Charge.
All as per Item No.103.00 here in before above but for point wiring with 4.0 sqmm single core multi stranded copper conductor PVC insulated and unsheathed (FRLSH) cable 1100 volts grade and 4.0 Sqmm PVC insulated and unsheathed (FRLSH) cable 1100 volts grade with multi-stranded copper conductor as earth wire for 15/16 Amps multipurpose socket combination point on independent board complete all as specified and directed by Engineer-in-Charge.
S&F switch Modular switch 1 way 6A, 1 module single pole complete all as specified and directed by Engineer-in-charge.
S&F modular Socket, 6A - 2/3 pin combined 2 module, ISI Marked with valid CML No complete all as specified and directed by Engineer-in-charge.
S&F Modular Switch socket Combination 16A, 5 pin, 3 module ISI Marked with valid CML No complete all as specified and directed by Engineer-in-charge.
S&F ceiling rose surface bakelite 3 terminals 230 Volts AC with polycarbonate body complete all as specified and directed by Engineer-in-charge.
S&F Modular Fan step regulator, 120W - 2 module ISI Marked with valid CML No complete all as specified and directed by Engineer-in-charge.
S&F Vertical triple pole & neutral, 4 way 415 Vdouble door powder coated CRCA stel sheet constructed as per IS : 8623 degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 250 Amps tinned copper bus bar, neutral busbar, earth bar, din bar bar detachable gland plat, interconnection, earthing connection, blanking plates in unused spaces as required suitable for TP/FP MCCB as incomer including MCCB 63 Amp 16 KA 415 Volt complete all as specified and directed by Engineer-in-charge.
S&F for sheet metal enclosure MCB SPN DB 8 way made out of 1.5 mm thick sheet metal enclosure IP 43 with 200 Amps rated bus bar 240 volts double door with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCBs and isolators etc complete all as specified and directed by Engineer-in-charge.
S&F MCB SPN 240 volts, 63 Amps, 10 KA repturing capacity C curve complete all as specified and directed by Engineer-in-charge.
S&F MCB SP 240 volts, 10 to 32 Amps, 10 KA, repturing capacity C curve complete all as specified and directed by Engineer-in-charge.
M&L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) concealed conduit circuit with two runs of single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engineer-in-charge. Note :- Two runs of 6.00 Sqmm cable & one run of 6.00 Sqmm cable continuity earth and one run of PVC conduit with all necessary accessories shall be paid as one unit length
S&F of LED tube light fitting 10 Watt tube LED neutral white in colour 600 mm in length wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation & integrated electronic driver optic diffused type including all electric connections with white flexible cord 1.5 sqmm 3 core as required10 W surface / wall mounted decorative type LED batten capable of deliverin complete all as specified and directed by Engineer-in-charge.
S&F surface and wall mounted LED tube light along with fixture 4 feet 20 Watt extruded aluminium housing provided for efficient heat disspation with polycarbonate, operating voltage 240 volts, 50 Hz, AC supply and operating temperature 0 to 50 degree C, power factor > 0.90, lumen output > 2000 and provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white colour flexible pipe complete all as specified and directed by Engineer-in-charge.
S&F LED street light of capacity 36 Watt with inbuilt driver having pressure die cast aluminium housing IP-66 having efficiancy of > 100 Lumens/Watt, operating voltahe - 120 to 270 Volts, P.F > 0.95, T.H.D < 10%, both fixture/ luminarie & driver must have separate bis marked registration and it must be mentioned clearly on fixture & as well as on drive also. Suitable for 30 to 50 mm O.D mounting pipe and suitable for mounting on wall/pole including connection with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-charge.
S&F 1.2 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed by Engineer-in-charge.
S&F ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor including necessary connecting cable as recommended by manufacturer complete all as specified and directed by Engineer-in-charge.
S&F exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed by Engineer-in-charge.
Cutting of wall with mason for making window suitable for fixing of 300mm exhaust fan and making good as per existing surface of wall complete all as specified and directed by Engineer-in-charge.
S&F water heater, storage type (geyser) vertical type inner container of capacity 25 litres power 2.0 KW, BEE 5 Star rated pressure rating >8 bar electrically operated, AC 230 volts including as per site required Nos of fashner nuts required suitable size fixed in brick/stone wall complete all as specified and directed by Engineer-in-charge.
S&F PVC connector pipe heavy duty of length 450mm,15 mm dia suitable for hot and cold water complete all as specified and directed by Engineer-in-charge.
M&L for bore earthing not less than 250mm dia 16 feet deep filled with black soil upto 7 feet from bottom complete with galvanised iron pipe 40mm bore medium grade 3m long tapers at bottom & provided 12mm holes (staggered) at 75mm centre to centre upto 2.5m of length from bottom, burried directly in ground filled with 45cm alternate layer of magnisium sulphate, charcol & salt up to ground level & connected to galvanised iron wire 4.0 mm dia above ground level as earthing lead by means of bolt and nut, check nuts and washers of galvanised iron or steel including brazing work upto equipment and 40mm dia light grade GI pipe for earth lead protection and testing on completion complete all as specified and directed by Engineer-in-charge.
S&F 20mm bore galvanized steel, medium grade, with all fittings, laid in trenches fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F 40mm bore galvanized steel, medium grade, with all fittings, laid in trenches fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F 40mm bore gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe with fittings and accessories, ISI marked and as per IS 14846 complete all as specified and directed by Engineer-in-Charge.
Cutting the existing pipe & inserting Tee size of 50x50x40mm complete all as specified and directed by Engineer-in-charge.
Supplying, laying, testing and commissioning of LT UG, XLPE insulated, heavy duty, 1100V grade of size 16 Sqmm 4 core electric cable with aluminum conductor, served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required complete all as specified and directed by Engineer-in-charge. Note : - Earthwork excavation sand cushioning, Jodhpur Stone patti, GI protection pipe shall be measured and paid separately in their respective items
M&L for sand cushioning to underground cable with sand and punning to provide required cover complete all as specified and directed by Engineer-in-charge. Note :- Punned thickness of sand cushioning shall only measured for the purpose of payment.
Supply & laying 40 to 50 mm thick roughly hammer dressed Jodhpur stone patti cable cover 25 cm to 30 cm wide and n.exc 60 cm long each laid dry abutting with each other with maximum gap between adjacent slabs n.exc 10 mm complete all as specified and directed by Engineer-in-charge.
S&F MCCB 4 pole 63 Amps, breaking capacity 16 KA, thermal and magnetic adjsutable type, 415 Volts with extended copper terminals complete all as specified and directed by Engineer-in-charge.
M&L for road cutting for the existing bituminous road /Hard Standing to size not exceeding 45cm wide and length not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surfaces filled with excavated material and Top 200mm depth wih PCC 1:3:6 type C-1 using 20mm graded aggregate complete all as specified and directed by Engineer-in-charge.
Supply and laying 50mm dia pipe galvanized iron steel tubing, light grade, with all fittings for protection of cables laid in trenches/ road / floor etc complete all as specified and directed by Engineer-in-charge.
AMBEY MAA CONSTRUCTION COMPANY (BID ID -3328252)
BHAGWATI CONSTRUCTION (BID ID -3317465)
KHUSBU CONSTRUCTION COMPANY (BID ID -3319878)
M/s Shri Inder Construction Company (BID ID -3316657)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .