Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.1 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹18.5 L+₹20,690.02 (1.13%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹18.7 L+₹43,655.26 (2.39%)Rejected-Finance | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹18.8 L+₹50,217.54 (2.75%)Rejected-Finance | L4 | Rejected-Finance L1 being accepted | |
| 5 | L5₹18.8 L+₹56,788.27 (3.11%)Rejected-Finance | L5 | Rejected-Finance L1 being accepted |
Tender Value
₹16.8 L
EMD Value
₹33,600
Closing Date
18 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 867 EWS
GE 867 EWS C/O 99 APO PIN 913867
PROVISION OF STORE NEAR BLDG NO. D-34 AT DALAPCHAND, PROVN OF TOILET NEAR BLDG NO. T-257 AND SPL REPAIRS TO CHEQUERED TILE PATH AT TEESTA TCP UNDER GE 867 EWS
2021_MES_464073_1
CA NO GE / 867 / TOKEN / 33 OF 2021-2022
Open Tender
Construction Works
Item Rate
180 days
Pedong
Refer tender documents
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹33,600
Yes
24 Aug 2021
30 Jul 2021
19 Aug 2021
30 Jul 2021
18 Aug 2021
13 Aug 2021
30 Jul 2021 - 5 Aug 2021
60 days
Amount
Surface excavation not exceeding 30 Cm deep and averaging 15 Cm deep and getting out in soft/loose soil all as specified and directed by Engineer-in-charge.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, laying of pipe, cable etc., or for shafts, wells, cesspits, manholes, pier holes, etc., not exceeding 10 sqm on plan and getting out in soft/loose soil all as specified and directed by Engineer-in-charge.
M&L for Plain cement concrete 1:4:8 mix type D2 (using 40 mm graded stone aggregate) in foundations, filling and mass-concrete etc., all as specified and directed by Engineer-in-Charge.
M&L for factory made precast cement block masonry with solid blocks made of Plain cement concrete 1:3:6 mix type C1 (using 20 mm graded stone aggregate) exceeding 10cm width and setting in cement mortar 1:6 complete all as specified and directed by Engineer-in-charge. Make : Shankar Saw Mills/Sangam Prefeb Products or equivalent make as approved by GE.
M&L for 25 mm thick plain cement concrete 1:2:4 Type B0 (using 12.5 mm graded stone aggregate) as in damp proof cource to horizontal or vertical surfaces including necessary formwork, with and including integral waterprofing compound @ 3% by weight of cement complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removing surplus excavated soil to a distance not exceeing 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for Hardcore with Broken stone/boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface all as specified and directed by Engineer-in-charge.
M&L for 75 mm thick Plain Cement Concrete 1:4:8, type D2 (using 40mm graded stone aggregate) as in sub base and finishing even and rough to receive toping layer complete all as specified and directed by Engineer-in-charge.
M & L for 40 mm thick plain cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in floor and the like laid in alternative bays in panels, and finishing cement concrete surface even and smooth with using extra cement complete all as specified and directed by Engr-in-charge.
M & L for 3mm thick 38 mm wide glass dividing strips, inserted in position in concrete floors to confirm to design complete all as specified and directed by Engr-in-charge.
M&L for rendering 15 mm thick on brickwork or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.
M&L for rendering 15 mm thick on brickwork or concrete surfaces in cement mortar 1:4 finished fair and even including waterproofing compound @ 3% by weight of cement as per manufacturer's instructions complete all as specified and directed by Engr-in-charge.
M&L preparing new plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of primer over thin layer of wall care putty (Birla white/Berger/Asian) complete all as specified and as directed by Engineer-in-Charge. Make: ASIAN/SHALIMAR/BERGER/ JENSON & NICHOLSON/IEL
M&L for preparing new plastered surfaces of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces on external walls complete all as specified and directed by Engineer-in-Charge. Make: APEX of ASIAN or equivalent in JENSON & NICHOLSON/ BERGER/ SHALIMAR
M&L for Fe-410W (Grd E-250) structural steel work Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., complete all as specified and directed by Engineer-in-Charge.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated (Trepezium or tiled pattern etc.,) steel sheet 0.50 mm thick (with 0.45 mm BMT) of any colour having tensile strength of 550 Mpa (pitch of corrugation shall be 200mm to 250mm and crest shall be 28mm to 32mm) as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick (with 0.45 mm BMT) of any colour having tensile strength of 550 Mpa as in roof covering, eaves board, ridges, hips,valley gutters, drip and straight flashing cladding to wall etc, fixed with self tapping screws including complete all as specified and directed by Engineer-in-Charge. Make for Item No. 17&18: TATA BLUESLOPPE/ LLYODS /JMBS/ EVEREST INDUSTRIES LTD/CRIL/JSW STEEL or equivalent as approved by GE.
S&F 125x60 mm size pressed steel door frame for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including PCC 1:3:6 type C0 filling complete all as directed by Engr-in-Charge. Make: - DIWAN STEELS/AVA STEELS/AJANTA ISPAT or equivalent as approved by GE.
S&F 30mm thick flush door shutters , solid core construction with block board core and plywood face panels,commercial type on both face complete all as specified directed by Engr-in-charge. Make:- Green ply/Kitply/Century/National/Swastik/ Ecoboard/Alishan/ Marino/ Archid/Novapan or equivalent as approved by GE.
S&F 150 mm long Aluminium alloy handles cast type anodised all as specified and directed.
S&F 250mm long aluminium alloy anodised sliding door bolts with hasp & staple (bolt type) and fixing clip of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified and directed. Make for Item No. 21&22: - CROWN/ CLASSIC/ JYOTHI/ AMIT/ MOWJEE
S&F steel window with side hung shutters (glazed or wire mesh shutters) fitted with box type hinges with suitable MS handles, peg stays, with glazing bars for receiving glass / MS flat for receiving wire mesh complete all as directed by Engr-in-charge. Make: M/s Madhu industries / M/s.SEN Harvick / AVA STEELS /M/s. Shiv Mular / M/s. AGEW. / M/s. Multiwyn Industries Corpn/ M/s Ganesh rolling shutters/Ajanta Ispat or equvalent make as approved by GE.
S&F Mild steel works as in grills, framed guard bars, and similar works conforming to Fe-290, Gde E-165 all as specified and directed.
S & F 3mm thick sheet glass ordinary quality fixed with oil putty and necessary clips/nut bolts area not exceeding 0.5Sqm in each pane complete all as directed by Engr-in-Charge. Make:- TRIVENI/ SAINT GOBAIN/ MODIGUARD/ATUL/ HINDUSTAN or equivalent as approved by GE.
M&L Preparing new or previously un treated surfaces of wood and wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer all as specified and directed.
M&L preparing old painted steel and iron surfaces of any description over 10 cm width or girth including and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Make for Item No. 26&27: ASIAN/ SHALIMAR/ BERGER/JENSON&NICHOLSON/IEL
M&L for reinforced cement concrete 1:2:4 mix, type B1 (using 20 mm graded stone aggregate) as in slabs, shelves and the like supported on walls all as specified and directed by Engineer-in-Charge. Note: Formwork and reinforcement shall be measured and paid seperately.
M&L for reinforced cement concrete 1:2:4 mix, type B1 (using 20 mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels exceeding 1.5 m span, bands etc., all as specified and directed by Engineer-in-Charge. Note: Formwork and reinforcement shall be measured and paid seperately.
Use and removal of steel formwork to sides and soffits of floor or roof beams, bands, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., for rough finished surfaces of concrete flat all as specified and directed by Engineer-in-Charge.
M&L for Mild steel deformed TMT bars 10mm dia and above as in reinforcement to concrete cut to length bent to shape required including cranking bending and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as directed by Engr-in-charge.
M&Lfor Mild steel deformed TMT bars 5mm dia and over up to and including 10 mm dia as in stirrups, spacers and binders , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified.
M&L 75 mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) in plinth protection/path laid in alternative bays finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Forming 65 mm deep x 10 mm wide construction (Dummy) joint filled with sealing compound grade A complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as in surface channels, drains including fair finishing inner surface of drain or channel using extra cement, including forms, moulds, mitred/ stopped ends etc., complete all as specified and directed.
M&L for cement concrete polished coloured chequered tiles 300 x300x 25 mm thick with grey cement and pigment, set and jointed in neat cement slurry and pointed in coloured cement to match the surfaces as in floors over and including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. Make: NITCO/ULTRA/EUROCON/DECO/BHARAT or equivalent as approved by GE.
M&L for 20 mm thick cement mortar 1:2 as in damp proof cource to horizontal or vertical surfaces including necessary formwork, with and including integral waterprofing compound @ 3% by weight of cement complete all as specified and directed by Engineer-in-Charge.
M&L for 100 mm thick Plain Cement Concrete 1:4:8, type D2 (using 40mm graded stone aggregate) as in sub base and finishing even and rough to receive toping layer complete all as specified and directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed by Engineer-in-charge. Make: LOVELYCEM/ SURYACEM/ JANATHACEM / LUCKYCEM or equivalent make as approved by GE.
S&F Fe 410-W (Gde-E- 250) quality-A Rolled steel sections, joist, channel, angle, flat or Tee sections fixed independently with angle cleats or other connecting plates etc., including dismantling exing steel work complete all as specified and directed by Engineer-in-charge.
S&F steel ventilators with top hung shutters (glazed or wire mesh shutters) fitted with box type hinges with suitable MS handles, peg stays complete all as directed by Engr-in-charge. Make: M/s Madhu industries / M/s.SEN Harvick / AVA STEELS /M/s. Shiv Mular / M/s. AGEW. / M/s. Multiwyn Industries Corpn/ M/s Ganesh rolling shutters/Ajanta Ispat or equvalent make as approved by GE.
S & F 3mm thick figured glass pin head type fixed with oil putty and necessary clips/nut bolts area exceeding 0.5Sqm in each pane complete all as directed by Engr-in-Charge. Make:- TRIVENI/ SAINT GOBAIN/ MODIGUARD/ATUL/ HINDUSTAN or equivalent as approved by GE.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick square/rectangular area of each tile exceeding 0.06 Sqm but not exceeding 0.11Sqm, in floors etc., jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed by Engr-in-charge.
M&L for coloured glazed ceramic tiles of size 300x200x7mm thick on vertical surfaces such as skirting/dado, jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on and including 10mm thick rendering in cement mortar 1:4 backing coat complete all as specified and directed by Engr-in-charge. Make for Item No 43&44: NITCO/ SOMANY/ ASIAN / JOHNSON/ORIENT
S&F factory made PVC Solid Door frame of size 50mmx47mm made out of 5mm plain coloured PVC sheet reinforced with MS Square tube, fixed in opening as per specification and dawings.
S&F Factory made Solid panel PVC Door Shutter of 30mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail ; Panelling of plain clour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beeding and jointed together with solvent cement as per specification and drawing. Make for Item No. 45 & 46: - SINTEX / RAJSHRI PLASTIWOOD/ NANDI/ UNIVERSAL
S&F 100 mm size mild steel cold rolled medium weight butt hinges complete all as specified and directed.
S&F 150 mm long Aluminium anodised barrel tower bolts of extruded aluminium section all as specified and directed.
S&F 125 mm long Aluminium alloy handles cast type anodised all as specified and directed. Make for Item No. 47 to 49: - CROWN/ CLASSIC/ JYOTHI/ AMIT/ MOWJEE
S&F Orrissa pattern vitreous china squatting pan white colour of size 580x440mm with integral footrest (Excluding flushing cistern and flush pipes) but including cement concrete bedding and P or S trap as required including PVC pipe upto finished floor level to connect flush pipe, complete all as directed by Engineer-in-Charge. Make: HINDWARE / NEYCER/ PARRYWARE / CERA
S&F Vitreous China wash basin, white, flat back, of size 550x400 mm, excluding taps, waste chain and plug and porcelain stopper but including brackets and 40mm dia brass chromium plated waste fitting and 40mm dia 90cm long PVC waste pipe, all as specified and directed by Engr-in-Charge. Make: HINDWARE / NEYCER/ PARRYWARE / CERA
S&F PVC valveless, symphonic action type, flushing cistern 10ltr capacity, low level, white with inlet ball valve float and handle along with suitable flush pipe/bend including brackets complete all as directed by Engr-in-Charge. Make: PARRY WARE (SLIMLINE)/ COMMANDER/ HINDWARE
S&F Pillar taps fancy type 15 mm bore, cast copper alloy, chromium plated with crown or capstan head screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks & fly-nuts, screwed for iron pipe all as specified and directed by Engr-in-Charge. Make: SEIKO/RYBO/SPECTRUM/ NMC/L&K/ESSCO (DELUXE)
S&F soap dish, vitreous China White, approximate size 160 x 160 x 90mm fixed with plugs with chromium plated brass screws all as specified and directed by Engineer-in-Charge.
S&F bib taps 15 mm bore, cast copper alloy chromium plated screwed down high pressure, with crown or capstan head, screwed for iron pipe all as specified and directed by Engr-in-Charge. Make: SEIKO/RYBO/SPECTRUM/ NMC/L&K/ESSCO (DELUXE)
S&F Stop/angle valves 15 mm bore, cast copper alloy chromium plated screwed down high pressure, with crown or capstan head, concealed type with long shank ang cup screwed both ends for iron pipe or for unions all as specified and directed by Engr-in-Charge. Make: SEIKO/RYBO/SPECTRUM/ NMC/L&K/ESSCO (DELUXE)
S&F PVC connection pipe 15mm dia, 450mm long with PTMT check nuts and washer on both ends complete all as directed by Engr-in-Charge. Make:- PRAYAG/POLYTUFF or equivalent as approved by GE.
S&F PVC (SWR) pipes 110mm bore single socket in any length with rubber ring joints fixed to wall or laid in floors complete all as directed by Engr-in-Charge.
S&F PVC (SWR) pipes 75mm bore single socket in any length with rubber ring joints fixed to wall or laid in floors complete all as directed by Engr-in-Charge.
S&F PVC (SWR) bends (any radius) suitable for 110mm bore pipe complete all as directed by Engr-in-charge.
S&F PVC (SWR) bends (any radius) suitable for 75mm bore pipe complete all as directed by Engr-in-charge.
S&F PVC (SWR) vent cowl 110mm complete all as directed by Engr-in-charge.
M&L in repairs PVC (SWR) floor trap 75/110mm dia plain with grating including jointing with solvent cement complete all as specified and directed by Engr-in-Charge. Make for item No 59 to 64: PRINCE/ SUDHAKAR/ NANDI/ FINOLEX/ SWASTIK/SUPRIME
M&L for Cement concrete 1:4:8 type D2 (Using 40mm graded stone agg) as in Concrete bed to 110mm drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed byEngr-in-Charge..
S&F 15mm bore unplasticised PVC pipes of pressure rating 10Kgf/Sqcm fixed complete to walls, ceiling or in floors etc., complete all as specified and directed by Engr-in-Charge.
S&F 20mm bore unplasticised PVC pipes of pressure rating 10Kgf/Sqcm fixed complete to walls, ceiling or in floors etc., complete all as specified and directed by Engr-in-Charge.
Demolition of plain cement concrete including tiles in ground floors and pavings n exc 15 cm thickness (below or above ground level) including removing rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of suitable size with all necessary fittings, fixed on walls/ceilings etc., including 1.5 Sq mm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes concealed type/surface type for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover (Make: Hylem or equivalent ) for housing switches, socket outlet, regulator etc., for one light /fan point controlled by one switch/one bell / buzzer point controlled by one bell push/one 3 / 5 -pin switch socket outlet 5 amps on independent board including testing on completion complete all as specified and directed by Engineer-in-Charge.
All as per item No. 69 above but for One 3/5 pin switch socket outlet 5 amps on same board along with other switches complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 2.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping, medium grade of suitable size with all necessary fittings, fixed on walls/ceilings etc., including 2.5 Sqmm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes concealed type/surface type for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover (Make: Hylem or equivalent ) for housing switches, socket outlet, regulator etc., for one 5 / 6 -pin switch socket outlet 15 amps on independent board including testing on completion complete all as specified and directed by Engineer-in-Charge. Make for Item No. 69 to 71 Cable: (i) Finolex, (ii) Plaza, (iii) Havells, (iv) Polycab, (v) KEI, (vi) Anchor Casing&Caping: (i) Kinjal, (ii) Alwyn (iii) Harsh, (iv) Finolex (v) Berlia (vi) Plaza
S&F switch piano, flush button, single pole, 5 amps, one way complete all as specified and as directed by Engineer-in-Charge.
S&F switch socket combination 2 – in – one, 3 Pin / 5 Pin, 5 amps flush type complete all as specified and as directed by Engineer-in-Charge.
S&F switch socket combination 2 – in – one 6 Pin , 5 / 15 amps flush type complete all as specified and as directed by Engineer-in-Charge.
S&F lamp holder, PVC/Polycarbonate insulated body with back plate for batten fittings complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose 3 terminal PVC/Polycarnonate, isolated body complete all as specified and as directed by Engineer-in-Charge. Make for Item No. 72 to 76: (i) Anchor (ii) Plaza, (iii) Havells (Crabtree) (iv) ABB (v) Shalabh
S&F 5 W retro fit B-22 LED lamp complete all as specified and as directed by Engineer-in-Charge. Make: Philips/Crompton/Havells.
S&F Energy efficient LED Tube light fitting, 4', 1x22 watt, with LED tube rod 22 Watt with bipin holders, connector block etc., complete with all accessories internally prewired and including connecting up with three core pvc sheathed flexible copper conductor cable of size 0.5 sqmm and 2 Nos PVC mounting blocks complete all as specified and as directed by Engineer-in-Charge. Make: Philips Model TMC 501, TMC 501P 1xT-LED 22 W P3241 or equivalent in Crompton/Havells.
Supply, Fixing, Testing & Commsioning of IP66 & IK09 integral LED Bulk Head luminaire with housing made of Pressure Die Cast alumunium & Optical cover made of Opal Polycarbonate for glare free lighting . System Lumen Output of minimum 600 lumens. Power Consumption should not exceed 10W (Including Driver Loss). For Glare free lighting luminaire should be with Opal diffused Polycarbonate, Color temperature 6500 K, CRI >80, Housing - High pressure die cast aluminum, Mounting - Surface, THD < 20%, PF >0.9, Operating voltage range 120V-277V AC. Submission of LM80-08 for LED source & LM79-08 for Luminaire from third NABL Accredited Lab / UL mandatory including connecting up with 3.0 core, 0.5 sqmm copper conductor sheathed complete all as specified and as directed by Engineer-in-Charge. MAKE: Philips, Cat part No. "WT 202W LED 6S CW PSU S2 PC", or equivalent in Crompton /Havells
S&F sheet metal enclosure DB SPN 8 way 240 V with 200 Amp rated bus bar, powder coated, double door complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing of MCB SPN 40 Amps, 10 KA breaking capacity, 240 volts, 50 Hz complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing of MCB SP 6 to 32 Amps, 10 KA breaking capacity, 240 volts, 50 Hz complete all as specified and as directed by Engineer-in-Charge. Make for Item No. 80 to 82: Legrand/Siemens/Schindler
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6.3 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI medium grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1:3:6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, 15 mm GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I complete all as specified and as directed by Engineer-in-Charge. NOTE: Rate quoted shall be deemed to include for earth lead and protection pipe upto 7.5m.
Supply and fixing Water heater storage type (Geyser), electric driven single phase 230 volt, 50 Hz of capacity 25 litres BEE 5 star rated with 2 KW heating element complete in all respect including grouting to wall with suitable size of nut, bolt and connecting with necessary electrical system complete all as specified and directed by Engineer-in-Charge. Make: V Guard Cat No. KRYSTAL PLUS N 25 LTR or equivalent in Bajaj/Venus/Racold/Havells/Crompton
S&F 15mm bore GI water tubing medium grade with all fittings and fixed to wall, floor, ceiling complete including short lengths all as specified and as directed by Engr-in-charge. Make: TATA/JINDAL/ZENITH
S&F Hot water out let connection made of brass chromium plated with Union rubber washer suitable for 15 mm bore Gi pipe complete all as directed by Engr-in-Charge.
Supply and spreading of dry river sand in trenches for cable protection and punned down complete all as directed by Engineer-in-Charge. Note:- Punned thickness only shall be measured for payment purpose.
Supply and laying kiln burnt bricks sub class B of size 250mm x 125mm x 750mm laid in trenches for cable covers complete all as specified and directed by Engineer-in-charge.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 2 core and connecting with necessary lugs complete all as specified and directed by Engineer-in-Charge. Note:- Excavation, earth work, brick protection, protection pipe and sand coushioning shall be measured and paid separately. Make of cable shall be CCI / Gloster / ICC / Unistar / NICCO / Asian (RPG) / Havells / Polycab/PRG/Universal/Plaza/Crystal cables/Terracom/ Rallison/Mescab/Jeypore/KEI
Material and labour for 40 mm dia bore GI tubing Light grade, laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection complete all as specified and directed by Egineer-in-Charge. Make: TATA/ZENITH/JINDAL
SANJAY SAW MILL
SANJAY MITTAL
DEEP CHANDRA JOSHI
SANJAY KAUSHIK
G K SUTHAR
S K ENTERPRISES
MANOJ JINDAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .