| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC RZ 50D GALI NO 13 VASHISHT PARK PANKHA ROAD NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Accepted AOC | |
| 2 | L2₹32.8 L+₹2.9 L (9.80%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹32.9 L+₹2.9 L (9.81%)Rejected-AOC G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹33.1 L+₹3.2 L (10.5%)Rejected-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹36.1 L+₹6.1 L (20.5%)Rejected-AOC | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | S.R. Constructions L5 | Sumit Enterprises L3 | M/S Anand Enterprises L4 | M/S PARKASH ENTERPRISES L1 | YANSHIKA SECURITY SERVICES L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00Schedule-A | ||||||||
| 1.01 | Disconnecting / taking down carefully existing unserviceable LT panel board / feeder pillar box any type and capacity including all control switches, fitting and fixtures from different location including disconnection of existing electric incomming and outgoing cable and dismantling of PCC platform and make good with existing surface complete all as directed by the Engr-in-Charge. | 4 | Each Job | 2,000 ₹8,000 | 3,000 ₹12,000 | 6,000 ₹24,000 | 5,000 ₹20,000 | 500 ₹2,000 Lowest |
| 2.00 | Supply, install commissioning and testing cubical out door feeder LT panel board of suitable size platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC 1:2:4 foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables. (16 BRD pump house)
LT Panel comprising of the folowing items as per Electricfication Specification
INCOMING
(a) MCCB, four pole, 400 Amp, 36 KA at 415 Volts, adjustable thermal and magnetic setting- 01 No.
(b) 600 Amps rated copper bus bar suitable for 4 pole system - 01 Set.
(c) Phase indicating lamp RYB LED type (Set of three ) -01 Set
(d) Voltmeter Digital type 0-500 Volts capacity with integeral selector switch dully prewired.
(e) Ammeter Digital type 0-400 Amp capacity with integeral selector switch and CT coils of suitable capacity 400/5A dully prewired.
OUT GOING
(a) MCCB four pole 200 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting- 05 Nos .
(b) MCCB four pole 160 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting-02 Nos | 1 | Each Job | 2,30,000 ₹2,30,000 | 1,75,000 ₹1,75,000 | 1,65,000 ₹1,65,000 Lowest | 1,65,000 ₹1,65,000 Lowest | 2,65,000 ₹2,65,000 |
| 3.00 | Supply, installF17:F18n class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables (16 BRD Fire Fighting) :-
LT Panel comprising of the folowing items as per Electricfication Specification
INCOMING
(a) MCCB, four pole, 200 Amp, 25 KA at 415 Volts, adjustable thermal and magnetic setting- 01 No.
(c) 600 Amps rated copper bus bar suitable for 04 pole system - 01 set.
(d) Phase indicating lamp RYB LED type (Set of three ) -01 Set
(e) Voltmeter Digital type 0-500 Volts capacity with integeral selector switch dully prewired.
(f) Ammeter Digital type 0-400 Amp capacity with integeral selector switch and CT coils of suitable capacity 400/5A dully prewired.
OUT GOING
(a) MCCB, triple pole, 125 Amp, 18 KA at 415 Volts, adjustable thermal and magnetic setting- 0 2No.
(b) Isolator DP 32 Amps, 10KA-01 NOs ( security lighting )
(c) Fully automatic star delta starter panel mounted of cap 75 HP- (02 Nos)
(d) Digital hour meter-02 Nos | 1 | Each Job | 2,30,000 ₹2,30,000 | 1,55,000 ₹1,55,000 Lowest | 1,65,000 ₹1,65,000 | 1,60,000 ₹1,60,000 | 2,75,000 ₹2,75,000 |
| 4.00 | Supply, install commissioning and testing cubical out door feeder LT panel board of suitable size not less than 1800x1500x450mm, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC 1:2:4 foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables.
LT Panel comprising of the folowing items as per Electricfication Specification
INCOMING
(a) MCCB, four pole, 400 Amp, 36 KA at 415 Volts, adjustable thermal and magnetic setting- 01 No.
(b) 600 Amps rated copper bus bar suitable for 4 pole system - 01 Set.
(c) Phase indicating lamp RYB LED type (Set of three ) -01 Set
(d) Voltmeter Digital type 0-500 Volts capacity with integeral selector switch dully prewired.
(e) Ammeter Digital type 0-400 Amp capacity with integeral selector switch and CT coils of suitable capacity 400/5A dully prewired.
OUT GOING
(a) MCCB four pole 200 Amps, 36KA at 415 Volts, adjustable thermal and magnetic setting- 03 Nos .
(b) MCCB four pole 160 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting-02 Nos
(c) Spare space for MCCB four pole 200 Amps, g- 02 Nos . | 1 | Each | 2,30,000 ₹2,30,000 | 1,95,000 ₹1,95,000 | 1,75,000 ₹1,75,000 Lowest | 2,25,000 ₹2,25,000 | 2,75,000 ₹2,75,000 |
| 5.00 | Supply, install commissioning and testing cubical out door feeder LT panel board of suitable size not less than 1800x1500x450mm, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC 1:2:4 foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables.
LT Panel comprising of the folowing items as per Electricfication Specification
INCOMING
(a) MCCB, four pole, 400 Amp, 36 KA at 415 Volts, adjustable thermal and magnetic setting- 01 No.
(b) 525 Amps rated copper bus bar suitable for 4 pole system - 01 Set.
(c) Phase indicating lamp RYB LED type (Set of three ) -01 Set
(d) Voltmeter Digital type 0-500 Volts capacity with integeral selector switch dully prewired.
(e) Ammeter Digital type 0-400 Amp capacity with integeral selector switch and CT coils of suitable capacity 400/5A dully prewired.
OUT GOING
(a) MCCB four pole 200 Amps, 36KA at 415 Volts, adjustable thermal and magnetic setting- 03 Nos .
(b) MCCB four pole 160 Amps, 36KA at 415 Volts, adjustable thermal and magnetic setting- 02 Nos .
(c) MCCB four pole 100 Amps, 16KA at 415 Volts, adjustable thermal and magnetic setting- 01 Nos . | 1 | Each | 2,30,000 ₹2,30,000 | 1,75,000 ₹1,75,000 Lowest | 1,80,000 ₹1,80,000 | 2,55,000 ₹2,55,000 | 2,75,000 ₹2,75,000 |
| 6.00 | Repair to voltage stabilizer automatic oil cooled 3 phase 4 wire AC supply servo controlled 440 V, 450 KVA to 500 KVA unbalanced type by disconnecting incoming and outgoing connections, reconnecting with suitable cable lugs , replacement of worn out wiring with copper cable including soldering of joints and providing sleaves, opening the top cover and replacement of top rubber gasket, bushing, rubber gasket, seal etc including including replacement of defective / warnout parts such as gear assemble , replacement of servo motor , carbon roller assemble, pcb, toggle switch, control transformer, indicatiing lamp, voltmeter, preston type switch by new spares including testing and commissioning all as directed. including dismantling and disconnecting of LT cables and refixing after repairing of stabliziser13 BRD and testing commissioning of the stabilizer on full load to the entire satisfication of Engr-in-Charge). (Note- Spare parts will be measured and paid separatly in relavant item )
Supply the following in the repair for 450 to 500 KVA Stabilizer :- | 2 | Each Job | 28,500 ₹57,000 | 41,000 ₹82,000 | 45,000 ₹90,000 | 25,000 ₹50,000 | 4,500 ₹9,000 Lowest |
| 6.01 | (a) Gear Assembly | 6 | Nos | 150 ₹900 | 750 ₹4,500 | 1,000 ₹6,000 | 50 ₹300 Lowest | 500 ₹3,000 |
| 6.02 | (b) Replacement of servomotor (02 Nos) 10 KG/CM torque | 4 | Nos | 120 ₹480 | 750 ₹3,000 | 1,000 ₹4,000 | 50 ₹200 Lowest | 2,500 ₹10,000 |
| 6.03 | (c) Replacement of carbon roller assembly | 2 | Nos | 135 ₹270 | 750 ₹1,500 | 1,000 ₹2,000 | 50 ₹100 Lowest | 500 ₹1,000 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
4 Sept 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Gurgaon No 1
GE (AF) Gurgaon No 1 Near Atul Kataria Chowk Gurgaon-122005
CA NO. GE AF NO.1/GUR-57/2025-26 REPAIR MAINT OF VOLTAGE STABILIZER, EM EQPT AND MISC REAIR MAINT OF EXTERNAL ELECTRIC SERVICES IN 16 BRD OF TECH AREA AND OTHER ALLIED WORKS AT AF STN PALAM UNDER GE (AF) GURGAON NO-1.
2025_MES_726139_1
GE(AF) No 1/GUR-57/2025-26
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Gurgaon No 1
All as per NIT
10 documents required · 10 mandatory
₹500
GE (AF) Gurgaon No 1
₹60,000
Yes
7 Oct 2025
14 Aug 2025
6 Sept 2025
14 Aug 2025
4 Sept 2025
28 Aug 2025
Amount
Schedule-A
Disconnecting / taking down carefully existing unserviceable LT panel board / feeder pillar box any type and capacity including all control switches, fitting and fixtures from different location including disconnection of existing electric incomming and outgoing cable and dismantling of PCC platform and make good with existing surface complete all as directed by the Engr-in-Charge.
Repair to voltage stabilizer automatic oil cooled 3 phase 4 wire AC supply servo controlled 440 V, 450 KVA to 500 KVA unbalanced type by disconnecting incoming and outgoing connections, reconnecting with suitable cable lugs , replacement of worn out wiring with copper cable including soldering of joints and providing sleaves, opening the top cover and replacement of top rubber gasket, bushing, rubber gasket, seal etc including including replacement of defective / warnout parts such as gear assemble , replacement of servo motor , carbon roller assemble, pcb, toggle switch, control transformer, indicatiing lamp, voltmeter, preston type switch by new spares including testing and commissioning all as directed. including dismantling and disconnecting of LT cables and refixing after repairing of stabliziser13 BRD and testing commissioning of the stabilizer on full load to the entire satisfication of Engr-in-Charge). (Note- Spare parts will be measured and paid separatly in relavant item ) Supply the following in the repair for 450 to 500 KVA Stabilizer :-
(a) Gear Assembly
(b) Replacement of servomotor (02 Nos) 10 KG/CM torque
(c) Replacement of carbon roller assembly
(d) Replacement of PCB
(e) High low voltage cut off
(f) Toggle switch
(g) Control transformer
(h) Replacement of indicating lamps complete
(k) Preston type switch
(l) Voltmer
(m) Ampere meter with CT
Repair to voltage stabilizer automatic oil cooled 3 phase 4 wire AC supply servo controlled 440 V, 400 KVA to 500 KVA unbalanced type by disconnecting incoming and outgoing connections, reconnecting with suitable cable lugs , replacement of worn out wiring with copper cable including soldering of joints and providing sleaves, opening the top cover and replacement of top rubber gasket, bushing, rubber gasket, seal etc including including replacement of defective / warnout parts such as gear assemble , replacement of servo motor , carbon roller assemble, pcb, toggle switch, control transformer, indicatiing lamp, voltmeter, preston type switch by new spares including testing and commissioning all as directed. including dismantling and disconnecting of LT cables and refixing after repairing of stabliziser 13 & 16 BRD and testing commissioning of the stabilizer on full load to the entire satisfication of Engr-in-Charge). (Note- Spare parts will be measured and paid separatly in relavant item )
Supply the following in the repair for 400 KVA Stabilizer :- (a) Gear Assembly
(b) Replacement of servomotor (02 Nos) 10 KG/CM torque
(c) Replacement of carbon roller assembly
(d) Replacement of PCB
(e) High low voltage cut off
(f) Toggle switch
(g) Control transformer
(h) Replacement of indicating lamps complete
(k) Preston type switch
(l) Voltmer
(m) Ampere meter with CT
Repair to voltage stabilizer automatic oil cooled 3 phase 4 wire AC supply servo controlled 440 V, 300 KVA unbalanced type by disconnecting incoming and outgoing connections, reconnecting with suitable cable lugs , replacement of worn out wiring with copper cable including soldering of joints and providing sleaves, opening the top cover and replacement of top rubber gasket, bushing, rubber gasket, seal etc including including replacement of defective / warnout parts such as gear assemble , replacement of servo motor , carbon roller assemble, pcb, toggle switch, control transformer, indicatiing lamp, voltmeter, preston type switch by new spares including testing and commissioning all as directed. including dismantling and disconnecting of LT cables and refixing after repairing of stabliziser13 BRD and testing commissioning of the stabilizer on full load to the entire satisfication of Engr-in-Charge). (Note- Spare parts will be measured and paid separatly in relavant item )
Supply the following in the repair for 300 KVA Stabilizer :- (a) Gear Assembly
(b) Replacement of servomotor (02 Nos) 10 KG/CM torque
(c) Replacement of carbon roller assembly
(d) Replacement of PCB
(e) High low voltage cut off
(f) Toggle switch
(g) Control transformer
(h) Replacement of indicating lamps complete
(k) Preston type switch
(l) Voltmer
(m) Ampere meter with CT
Dehydration/filtration of stabilizer and other lt equipment oil by means of centrifugal filtration plant to achieve the specified dielectric strength of 40 KV at 2.5 mm gap in existing position of transformer/stabilizer of any capacity and transformer oil for topping up at various sub station complete all specified and as directed. NOTE: Transformer oil for TOP UP shall be measured and paid separately under respective item of this schedule
Supply only transformer oil of approved quality (Dielectric strength not less than 40 KV) ISI marked for filling in transformer for topping up all as directed by Engr-in-Charge. Note : Factory sealed container of transformer oil will be accepted.
M&L for rewinding of burnt out LT dimmerstate/coils of three phase servo stabilizer of capacity 15 KVA to 1500 KVA with super enamelled copper winding wire of existing gauge and proper number of turns alongwith insulating material i.e leatheroid, paper insulation, cotton tapes, empire tapes, wooden block packings, PVC sleeves, soldering and varnishing with insulating varnish , colding/drying etc complete all as specified and directed.
Taking down/dismantling and refixing of any capacity of stabilizer/LT equipments by using Hydra mechine/suitable crane complete and including tranportation shifting to approved manufacturer/Workshop including testing and commissioning all as directed. (Note- Dismantling and disconnecting HT cable and LT cables and refixing after rewinding and Transportation from 13 BRD to Workshop and workshop to 13 BRD will be paid as one job)
M&L for painting of servo stabilizer after cleaning the body surface of stabilizer by rubbing with emery Ppper to remove oil stains, dust etc and applying two coat of snthetic enamel paint by spray paint incl writing SM No/MES No , capacity of stabilizer of following capacity all as directed by Engr-in-Charge. The contractor has to arrange their own local generator for supply to the spray painting machine. (a) 300 KVA to 400 KVA
(b) 450 KVA to 500 KVA
Supply and laying of round boulders of gauge 63 mm graded as in bedding layer around electrical equipment or installation ,LT Panel etc complete all as specified and directed.
Supply and fixing of busbar in repair for giving common output including taking down old U/S busbars from panel of alluminium strap suitable for LT suppy 415 volts , 4 winding system including making necessary cable connection for making hole in busbar complete all as specified and directed by Engr-in-Charge.
Supply and fixing of busbar in repair for giving common output including taking down old U/S busbars from panel of copper strap of size 50x6mm duly insulated suitable for LT suppy 415 volts , 4 winding system including fixing on wall/panel complete with suitable clamp as required on sited including making necessary electrical and cable connection and making hole in busbar complete all as specified and directed by Engr-in-Charge.
S&F Sandwich type bus trunking system with Aluminium bus bar 3000 Amps, 50 KA breaking capacity for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes (One tap off box in one metre) and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos COPPER bus bars, necessary joints, connecting to earthing system etc. complete all as specified and directed. Makes : C&S/Legrand/L&T/ ABB/Schneider/Havell's.
S&F Sandwich type bus trunking system with copper bus bar 400 Amps, 25 KA breaking capacity for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes (One tap off box in one metre) and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos COPPER bus bars, necessary joints, connecting to earthing system etc. complete all as specified and directed. Makes : C&S/Legrand/L&T/ ABB/Schneider/Havell's.
Supply and fix in repair busbar insulator to insulating the bar from pillar box suitable for 415 volts AC supply insulation complete all as specified and directed
S&F in replacement of MCCB 3 pole, capacity 100 Amps with breaking capacity 16KA, overload setting adjustable and short circuit setting fixed complete all as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand
S&F in replacement of MCCB 3 pole, capacity 125 Amps with breaking capacity 16 KA, overload setting adjustable and short circuit setting fixed complete with necessary modifications in Panel Board for connection of MCCBs complete all as directed including disconnecting UNSV MCCBs Connecting and testing all as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand
S&F On /off load Change over switch with sheet enclosure type 1000 Amps 4 pole 415 Volts including taking out of unserviceable one complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised iron strips 32 x 6 mm by means of nuts both check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 40 mm bore medium grade upto ground level as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1 pre cast RCC cover slab 30 cm x 30 cm x 10 cm thick including reinforcement with 8 mm dia steel deformed bars at the rate of 10 cm both ways with one lifting handle made of 8 mm dia MS bar funnel, wire mesh 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal on coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Pt-I and testing on completion
Earth continuity conductor or main earthing lead fixed to wal on batten or recess or chasses or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation of 25x4 mm galvanised iron strip
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chasses or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation of 20X3 mm copper strip
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chasses or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation of 32X6 mm copper strip
Taking up old serviceable/unserviceable UG cable from trench for replacement , repair and re-laying or re-routing of size 70 Sqmm to 95 Sqmm
Supply , Laying , testing and commissioning XLPE insulated and PVC Sheathed , galvanized steel strip or wire armoured , heavy duty electric cable with multi stranded aluminium conductor , 1100 volts grade of size 95 sqmm 3.5 core complete all as specified & directed by Engineer - In - Charge.
Excavation in treanches in soft loose /soil not exc 1.5m wide and not exc 1.5m deep and getting out for taking out and laying cables foudation etc. Brick PCC cables protection cover shall be retrieved and kept in safe costody for reuse).
Returning filling in including spreading leveling waterning and well remmaning in layers not exc 25cm thick all as directed .
Removing of surplus spoil to a distnce not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point.
M&L for dry clean sand filling in trenches below and around under ground cable cushioning complete all as specified and directed. Note :- Thickness of sand cushioning shall be measured after punning.
M&L for brick protection with sub class 'B' Designation 75 old bricks laid dry flat 23cm in width over sand cushioning in trenches as perpendicular to the direction of underground cable complete all as specified and as directed.
M &L for demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level)
M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregates for filling in road cuts/hard standing etc all as specified and as directed.
Boring of holes under road, pavement, hard standing for more than 5 mtr in length by trenchless, technology using ultra sound technique and necessary machine, including HDPE pipe of 80 mm dia suitable for 0.4 mpa working pressure.
M&L for cutting the existing bitumen us road/payment/footpath upto 0.75 mtr in depth, 0.45 mtr in width and getting out excavated material and making good the damaged portion after laying the pipe, returning filling in mass concrete PCC 1:2:4 type B2 upto top of the road all as directed by Engr-in-Charge. Note :-(i) M&L for laying of pipe shall be measured and paid separately.
Cutting chases, pining in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed conduit wiring, etc and making good, cutting exceeding 10 cm but not exceeding 20 cm girth.
S & F GI tubing 80 mm dia light grade in protection of cable of difference dia laid in trench under road/foot path or fixed on pole with necessary clamps with bolts etc all as directed.
M&L for PVC/Accralyic type insulator of required size not less than 100cm x 75 cm long and 50 cm height with flat bootom climping the Lightening strip on top end for fixed open on roof top properly with required size nuts & bolts/screw if required for separated to lightining conductor or earthing stirp from building all as required at site & directed by engineer in charge. Note : The distance between two insulators fixed on the on roof on ground condition.
Supply & Fixing porcelain insulator of required size not less than 40 cm long with two nos hole each on both end for fixing properly with nuts & bolts on wall of buildings/pipe for separated to lightining conductor or earthing stirp from building all as required at site & directed by engineer in charge. Note : The distance between two insulators fixed on the wall not more than 1 mtr length.
M&L for sign board of coloured accrylic sheet , fixed in stainless steel frame of 50 mm dia of 304 grade, letter size as approved by GE , size of acrylic sheet not less than 90cm x 75 cm, height of board after embedding from ground level is 6 feet (top of frame), including grouting in PCC 1:2:4, 450mm below ground level, size of PCC (1:2:4), (30cmx30cmx45cm). Letter on the accryliic sheet should be rof reflected type complete all as specified and directed by engineer-in-charges
M&L for detecting of fault in HT/LT 1100/1000 volt cable of any size upto 400 sqmm x3.5 Core laid in trench by fault locating machine comprising of surge generating pulse, ECHO fault locator with high frequency distance calculator etc and exposing the cable fault, removing of deteriorated portion of cable, treating of cable and same ready for jointing work complete all as specified and directed by Engr- In- Charge.
M&L for heat shrinkable jointing kit including suitable size of connector complete all as per directed by Engr-in-charge:- Cost of necessary work and labour jointing kit complete fixing charges and T&P including removing of grass/shrubs nearby the fault location shall be deamed to be included in the quoted rate in the following sizes:- (i) XLPE Cable of size 25 to 50 sqmm 3.5/4 core
(ii) XLPE Cable of size 70 to 120 sqmm 3.5/4 core
(iii) XLPE Cable of size 150 to 400 sqmm 3.5/4 core
Note :- The amount of Rs 131056/- against Schedule of Credit on Srl Page 142 & 143 shall be deducted from the total amount quoted against Sch 'A'
YANSHIKA SECURITY SERVICES (BID ID -3414420)
Sumit Enterprises (BID ID -3415680)
M/S Anand Enterprises (BID ID -3415925)
S.R. Constructions (BID ID -3414927)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .