| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.3 LAccepted-AOC G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | ₹43.3 L Quoted ₹44.3 L | L1 | Accepted-AOC AOC |
| 2 | L2₹44.8 LRejected-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | ₹44.8 L | L2 | Rejected-AOC Rejected |
| 3 | L3₹46.1 LRejected-AOC RZ 50D GALI NO 13 VASHISHT PARK PANKHA ROAD NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | ₹46.1 L | L3 | Rejected-AOC Rejected |
| 4 | L4₹46.4 LRejected-AOC FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹46.4 L | L4 | Rejected-AOC Rejected |
| 5 | Rejected-Technical GROUND FLOOR F 11 PHASE II MAYAPURI WEST DELHI DELHI 110064 | DELHI | WEST DELHI | DELHI | 110064 | - | - | Rejected-Technical No not enlisted in cvi and c vii cat |
| Sl No | Description | Qty | Unit | Sumit Enterprises L1 | M/S Anand Enterprises L2 | M/S PARKASH ENTERPRISES L3 | BRIJ MOHAN LAL AND CO. L4 |
|---|---|---|---|---|---|---|---|
| 1.00Schedule-A (E/M Work) | |||||||
| 1.01 | Excavation in trenches in any type of soil i.e. loose/soft not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in width and getting out complete all as specified and as directed by Engineer-In-Charge. | 18 | Cum | 120 ₹2,160 | 150 ₹2,700 | 100 ₹1,800 | 164 ₹2,952 |
| 2.00 | Returning, filling and including spreading, leveling and watering and well ramming in layers not exceeding 25 cm to achieve desired compactness as directed by Engineer-In-Charge. | 16.2 | Cum | 40 ₹648 | 50 ₹810 | 20 ₹324 | 62 ₹1,004.40 |
| 3.00 | Removing of excavated material/soil to a distance not exceeding 50 Mtrs and depositing at a level not exceeding 1.5 Mtr above the starting point all as directed by Engineer-In-Charge. | 1.8 | Cum | 40 ₹72 | 50 ₹90 | 20 ₹36 | 57 ₹102.60 |
| 4.00 | M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregates) for repairing of valve chamber foundation etc including filling in road cuts/ hard standing etc complete all as specified and as directed. | 2 | Cum | 2,500 ₹5,000 | 2,500 ₹5,000 | 3,500 ₹7,000 | 2,576 ₹5,152 |
| 5.00 | Demolition of old brick work and M&L for brick work in cement mortar 1:6 using sub class 'B' brick straight or curved on plain not exceeding 6m mean radius complete all as specified and as directed. | 1 | Cum | 400 ₹400 | 500 ₹500 | 500 ₹500 | 532 ₹532 |
| 6.00 | M&L for 10 mm thick cement plaster in cement mortar 1:4 on brick/concrete surface etc finished even and smooth without using extra cement complete all as specified and directed. | 20 | Sqm | 200 ₹4,000 | 250 ₹5,000 | 500 ₹10,000 | 261 ₹5,220 |
| 7.00 | M&L for General overhauling & servicing of Jockey pump set of 15 HP motor complete with cleaning, change of gasket, greasing, coupling etc all as specified and as directed by engineer in charge Note cost of transportation, loading and lifting are deemed to be fit in quoted rates by the contractor. | 2 | Each job | 14,500 ₹29,000 | 18,000 ₹36,000 | 35,000 ₹70,000 | 18,210 ₹36,420 |
| 8.00 | Supply and fix in replacement of 200 ltr capacity MS diesel tank with level indicator complete all as specified and as directed by engineer in charge | 1 | Each | 12,000 ₹12,000 | 15,000 ₹15,000 | 7,500 ₹7,500 | 15,120 ₹15,120 |
| 9.00 | M&L for Hydraulic testing of air vessel with air release valve, ball valve complete all as specified and as directed by engineer in charge | 2 | Each Job | 4,000 ₹8,000 | 8,000 ₹16,000 | 3,000 ₹6,000 | 8,030 ₹16,060 |
Updated dates
Tender Value
₹44.9 Cr
EMD Value
₹89,880
Closing Date
17 Dec 2025, 6:00 pmClosed
GE (AF) Gurgaon No 1
GE (AF) Gurgaon No 1 Near Atul Kataria Chowk Gurgaon
CA NO. GE AF NO.1/GUR-65/2025-26 REPAIR /MAINT OF EXTERNAL WATER SUPPLY, FIRE FIGHTING SYSTEM, FIRE ALARM AND OTHER CONNECTED WORKS AND REPAIR/MAIN OF SEWAGE TREATMENT PLANT 800 KLD AND OTHER CONNECTED WKS AT SEKHON VIHAR UNDER GE (AF) GURGAON NO 1
2025_MES_740434_1
GE(AF) No 1/GUR-65/2025-26
Open Tender
Miscellaneous Works
180 days
GE (AF) Gurgaon No 1
All as per NIT
10 documents required · 10 mandatory
₹500
GE (AF) Gurgaon No 1
₹89,880
Yes
25 Jan 2026
19 Nov 2025
19 Dec 2025
19 Nov 2025
17 Dec 2025
3 Dec 2025
Amount
Schedule-A (E/M Work)
Excavation in trenches in any type of soil i.e. loose/soft not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in width and getting out complete all as specified and as directed by Engineer-In-Charge.
Returning, filling and including spreading, leveling and watering and well ramming in layers not exceeding 25 cm to achieve desired compactness as directed by Engineer-In-Charge.
Removing of excavated material/soil to a distance not exceeding 50 Mtrs and depositing at a level not exceeding 1.5 Mtr above the starting point all as directed by Engineer-In-Charge.
M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregates) for repairing of valve chamber foundation etc including filling in road cuts/ hard standing etc complete all as specified and as directed.
Demolition of old brick work and M&L for brick work in cement mortar 1:6 using sub class 'B' brick straight or curved on plain not exceeding 6m mean radius complete all as specified and as directed.
M&L for 10 mm thick cement plaster in cement mortar 1:4 on brick/concrete surface etc finished even and smooth without using extra cement complete all as specified and directed.
Supply and fix in replacement of 200 ltr capacity MS diesel tank with level indicator complete all as specified and as directed by engineer in charge
M&L for Hydraulic testing of air vessel with air release valve, ball valve complete all as specified and as directed by engineer in charge
Supply and fix in replacement of Y-strainer 200mm dia complete all as specified and as directed by engineer in charge.
Taking out sluice valves, & supply and Fix new Sluice valve IS 14846 PN 1.6 SS spindle flanged type of size 200mm bore including necy gaskets and nut bolts as reqd at site .
All as per item No.11 above but of size 150mm bore
All as per item No.11 above but of size 100mm bore
All as per item No.11 above but of size 80mm bore
Supply and fix in replacement of non return sluice valve of size 200 mm all as specified and as directed by engineer in charge.
Supply and fix in replacement of non return sluice valve of size 100 mm all as specified and as directed by engineer in charge
Supply and fix in replacement of Foot Valve conforming to IS 4038, 200 mm (8”) dia all as specified and as directed by engineer in charge .
Supply & fix in replacement of fire hydrant landing valve type A (single head outlet) of 63 mm dia conforming to IS 5290
Supply and fix in replacement of hose reel of 20 mm dia and 30 meter length conforming to IS 5132
Supply and fix in replacement of SS branch pipe with nozzle of 20 mm dia for hose reel conforming to IS 8090
Supply and fix in replacement of Fire brigade inlet connection 4 way all as specified and as directed by engineer in charge
Supply and fixing 63 mm brass coated male & female coupling in hose pipe of fire fighting hose box as specified and directed.
Supply and fix in replacement of Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard inside yard all as specified and as directed by engineer in charge
M&L for painting with spray gun with two coats of synthetic enameled red paint over a coat of red oxide primer including preparation of old painted surfaces/ removing old faded/ rust/ cemented material of surface for fire hose box of size 18 gauge MS Sheet of size 800mm X 600mm X 250mm on both sides complete all as specifed and as directed.
Taking out sluice valves for replacement of SS spindle flanged type of size 100mm bore including necy gaskets and nut bolts as reqd at site .
Detecting any type of fault in any type of stater panels by providing skilled tradesman & helper with necessary safety working equipments and other required tools and plants to rectified the defects on top priority basis as and when required including testing complete all as specified and directed.
Material & labour for replacement and welding of MS flange with 08 nos of holes for 100 mm bore MS pipe all as specified and as directed by engr in charge
Supply & Fix in replacement of Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short for hose reel all as specified and as directed by engr in charge
Supply and fix in replacement of pressure guage 4" , 0-21 Kg complete all as specified and as directed by engineer in charge
Supply and fix in replacement of Foot Valve conforming to IS 4038, 150 mm (6”) dia all as specified and as directed by engineer in charge .
Supply and fix in replacement of Y-strainer 100 mm dia complete all as specified and as directed by engineer in charge.
M&L for Servicing & cleaning of Y-strainer after dismantling from system 100/200 mm dia complete all as specified and as directed by engineer in charge
Supply and fix in replacement of Pressure switch Universal type complete all as specified and as directed by engineer in charge
Supply and fix in replacement of Y-strainer 80mm dia complete all as specified and as directed by engineer in charge.
M&L for painting with spray gun with two coats of synthetic enameled red paint over a coat of red oxide primer including preparation of old painted surfaces/ removing old faded/ rust/ cemented material of surface for the all items complete of approved shade for 100 mm dia MS pipe on roof of block and from top to bottom of fire line, hose drum and necy sluic valves of each block on both sides of G+10 floors pipe line complete all as specified and directed.
M&L for painting of fire door of 18 gauge sheet welded on angle iron frame with half glass portion and half MS sheet fof size 2.2 mtr x 1.2 Mtr duly painted red colour with synthetic enamaled paint on both side complete all as specified and as directed by Engineer-in-charge.
M&L for replacing of 6 mm thick glass of fire door of 18 gauge sheet welded on angle iron frame having half glass portion and half MS sheet complete as per existing size all as specified and as directed by Engineer-in-charge.
Disconnect the cable connection from Jocky pump set of capacity 15 HP from fire pump house LT Panel and repair of same by rewinding with super enameled copper wire as per existing gauge including varnishing, making it serviceable by replacement of all unserviceable spares like pump impeller- 01 No, inner and outer rotor - 01 set, complete gasket - 01 Set and bushing-02 Nos and testing the same. After tesitng lowering the submersible pump set and making connection of pipelines complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement of flexible coupling for 12.5 Hp motor pump set as per sample.
Supply and fixing in replacement of coupling hub suitable for single/multi stage centrifugal pump set of 12.5 HP capacity complete with all plates, nuts, bolts and connected accessories.
M&L for in replacement of unserviceable conventional 22 zone fire alarm panel with PA symtem .
M&L for repair/replacement of unserviceable wall mounted hooter with atleast 60 db sound.
Taking up or down from trenches/wall/floor any size CI pipe and fittings including for refixing or for schedule of credit complete all as directed (Note:- Earth work will be measured & paid separately.)
M&L of Cast iron pipes with flanged ends, centrifugally cast, class A tubing of size 80 mm bore complete all as specified and as directed by Engineer-in-charge.
M&L of Cast iron pipes with flanged ends, centrifugally cast, class A tubing of size 100 mm bore complete all as specified and as directed by Engineer-in-charge.
M&L of Cast iron pipes with flanged ends, centrifugally cast, class A tubing of size 150 mm bore complete all as specified and as directed by Engineer-in-charge.
M&L of Cast iron pipes with flanged ends, centrifugally cast, class A tubing of size 200 mm bore complete all as specified and as directed by Engineer-in-charge.
M&L for burning of lead joint for CI pipelines of size 80 mm bore complete all as specified and as directed By Engineer-in-charge.
M&L for burning of lead joint for CI pipelines of size 100 mm bore complete all as specified and as directed By Engineer-in-charge.
M&L for burning of lead joint for CI pipelines of size 150 mm bore complete all as specified and as directed By Engineer-in-charge.
M&L for burning of lead joint for CI pipelines of size 200 mm bore complete all as specified and as directed By Engineer-in-charge.
S&F in replacement of flexible coupling for 50 Hp motor pump set as per sample.
S&F in replacement of coupling hub suitable for single/multi stage centrifugal pump set of 50 HP capacity complete with all plates, nuts, bolts and connected accessories.
S&F in replacement of of bearing no 6309 suitable for 50 HP centrifugal pump set complete all as per matching to existing.
S&F in replacement of shaft for centrifugal pump set of 50 HP capacity complete as per matching to existing.
S&F in replacement of long & short bush for centrifugal pump set of 50 HP capacity complete as per matching to existing.
Supply & Fix in replacement of cast iron type closed impeller for centrifugal pump set of 50 HP capacity complete as per matching to existing.
Lifting of submersible pump set of capacity 10 HP with column pipe of size 50/80 mm bore dia ,40 Nos of each 3 meters long from 200/300 mm dia bore well, dismantling submersible pump and each pipe section with and including cleaning of pipes by using wire brush/non toxic solution etc. and washing thoroughly and connecting the column pipes after cleaning of threaded/flanged portions and replacement of worn out nuts, bolts attached and then coupling and lowering the submersible pump with column pipes carefully and put into operation complete all as specified and as directed. Note : Replaced of column pipe will be measured and paid under respective items here in after.
M&L dewatering, cleaning of water supply storage tanks of capacity 40000 Ltrs at SEKHON VIHAR 10 storey bldgs with high pressure jet complete all as directed as following:- (i) Dewatering the tank with portable submersible pump. (ii) Removal of left over dirty water and sludge with special sludge removal pump set. (iii) Cleaning of wall ceiling and floor by high pressure rotary water jet pump which create pressure of 80-120. (iv) Removing remaining sludge from the floor with the help of industrial vaccum cleaner. (v) Treatment of inside tank be exposing UV radiation kill the suspended or floating bacterial remaining in the tank. (vi) Fixing of tank lid/cover properly after cleaning with proper locking to avoid monkey menace.
Supply & Fix in replacement of PN 1.6 pressure CI Non return valve of size 150mm in suction / delivery pipeline complete all as specified and as directed by Engineer-in-charge.
Supply & Fix in replacement of PN 1.6 pressure CI air release valve with strainer of size 150mm in suction pipeline complete all as specified and as directed by Engineer-in-charge.
Supply & Fix in replacement of Gun-metal gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 80mm bore complete all as specifed and as directed by Engineer-in-charge.
Supply on CDD 5000 (two components chlorine di oxide powder) (CAS No 10049-04-4 confirming to ISO9001-2015) white in colour highly soluble in water, 99.9% effective against water bornemicro organisms disinfectant for chlorination of water complete all as specified and directed bi Engr-in-charge
Supply & Fix replacement of Power contactor MNX type MNX-25 as per site reqmt.
Supply & Fix replacement of Power contactor MNX type MNX-32 as per site reqmt. .
Supply & Fix replacement of Power contactor MNX type MNX-40 as per site reqmt. .
Supply & Fix replacement of Power contactor MNX type MNX-50 as per site reqmt. .
Supply & Fix replacement of Power contactor MNX type MNX-80 as per site reqmt..
Supply & Fix replacement of Overload Relays 06 to 10 Amps for power contactor MNX-25 type.
Supply & Fix replacement of Overload Relays 09 to 15 Amps for power contactor MNX-32 type.
Supply and Fix replacement of Overload Relays 20 to 23 Amps for power contactor MNX-40 type.
Supply & fixing in replacement of phase sequence corrector 3 phase 415 volts with time delay relay with and including input supply, reverse phase protection against single phasing, voltage unbalancing, low voltage, hnigh voltage etc with necessary copper connections all as specified and directed.
Supply and Fix in replacement of phase sequence relay.
Supply and Fix replacement of Single Phase Preventor .
Supply & fix replacement of indicating lamps with LED lamps in starter panel.
Supply and fix in replacement of DOL starter panel consisting of main ON/OFF switch, fuses, SPP water level controller, temp controller, ammeter, voltmeter with VSS, automanual switch, moisture sensor for pump of capacity 5.5 KW of make KSB model F100-215.
Supply & Fix in replacement of 3 core 6 sqmm copper conductor flat submersible cable complete all as specified and as directed by Engineer-in-charge.
Supply & Fix in replacement of single core 10 sqmm copper conductor flexible cable for connection of pumps at STP complete all as specified and as directed by Engineer-in-charge.
Supply & Fix in replacement of single core 25 sqmm copper conductor flexible cable for connection of 50 HP centrifugal pumps from stater panel at pump house complete all as specified and as directed by Engineer-in-charge.
Disconnecting the cable connection and removing unserviceable ammeter of size 96 mm x 96 mm and supply and fix in replacement of Digital ammeter of existing size and shape incliding necessary connections complete all as specified and directed
Disconnecting the cable connection and removing unserviceable voltmeter of size 96 mm x 96 mm and supply and fix in replacement of Digital voltmeter of existing size and shape incliding necessary connections complete all as specified and directed
M&L for filling gland doori of any size for arresting the water leakage for water pumps and sluice valves all as directed by Engg-In-Charge.
M&L for preparation of old painted surfaces at pump house like 50 Hp centrifugal pump with motor - 04 Nos, 150mm/200 mm CI pipe line - 48 RM incl removal of grease, spots, dust etc and applying of two coats of synthetic enamel paint on existing surfaces complete all as specified and directed.
M&L in replacement of cast iron fittings up to 150 mm bore ie bend, Tee pieces, Y junction, cross, collars, caps and plugs, connecting pieces etc including taking out/dismantling old unserviceable fittings, complete all as specified and directed.
Supply and fixing in replacement Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed of size 25 mm bore all as specified and directed.
Supply and fixing GI column pipes both ends flanged type of 50 mm bore dia heavy duty(each pipe of 3 meters) long as per site requirement complete all as specified and as directed.
Supply and fixing GI column pipes both ends flanged type of 80 mm bore dia heavy duty(each pipe of 3 meters) long as per site requirement complete all as specified and as directed.
Dismantling of damage/broken valve chamber and Construction of valve chamber in brick masonary built CM (1:4) with MS frame of size 45x45x6 mm thcik with MS plate cover 1.6 mm thick and locking arragement including excavation and earth work in any type of soil, PCC (1;3:6) type C1 in foundation PCC(1:2:4) type B1 for coping plastering on brick work 10 mm thick in CM(1:4) type Bq and painting with one coat of red oxide primer and two coats of bituminous black paint on all steel surfaces all as specified and as directed of size 1200 mm x 1200 mm x 1200 mm. Note : The rate quoted is deemed to be included the cost of excavation and earth work complete.
M&L for Audit of fire fighting system installed at Fire Pump House at Sekhon Vihar as under: Objective 1-To find out the drop in performance of main fire pumps 75 HP (02 nos) Jockey pump 15 HP (02 nos), MS pipe line of size 80 mm to 200 mm, Sluice valve of size from 80 mm to 200 mm, NRV of size from 80mm to 200 mm, yard hydrants, wet risers etc to ascertain the fire fighting capacity of hydrant 2- Fire Safety Audit -To audit the Fire safety arrangement. 3- Audit of Emergency Preparedness Methodology 1. Shut of the complete hydrant system and measure head of the pump. 2. Adjust head of the pump by existing valve of the hydrant, measure the flow of water by opening the hydrant accordingly. 3. Hydrant to be opened to be delivered 125% of the flow. 4. To check the rpm of pump at each operating point. 5. Draw performance curve to show actual verses original pump data. Note: Audit of fire fighting system shall be done by specialist approved agencies.
M&L for Hydraulic testing of air vessel with air release valve, ball valve complete all as specified and as directed by engineer in charge
Testing of Bore well water/UG sump to analysis the following parameter as per IS 10500:2000 through Govt. approved agency:- a) Physicochemical parameters of water / eflluent sample b) Bactoriological test of water sample. c) Metals (Expect Hg, As & Se). d) Pesticides. Note:- Water sample for testing shall be arranged by the contractor. 2. Testing shall be done at a span of every 3 months starting from the date of commencement.
M&L for rectification of leakage from 80 mm size bore GI pipe line by cutting and removing old lengh of pipe, supply & fix new new galvanised iron pipe 80 mm bore medium grade pipe for stopping the leakage by making welding/replacemnt of necessary fittings of the same after drain out water from pipeline including insertion of pipe length upto 01 RM complete all as specifed and as directed by Engineer-in-charge.
M&L for rectification of leakage from GI 50 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 50 mm bore medium grade pipe for stopping the leakage by making welding/replacemnt of necessary fittings of the same after drain out water from pipeline including insertion of pipe length upto 01 RM complete all as specifed and as directed by Engineer-in-charge.
M&L for rectification of leakage from GI 40 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 40 mm bore medium grade pipe for stopping the leakage by making welding/replacemnt of necessary fittings of the same after drain out water from pipeline including insertion of pipe length upto 01 RM complete all as specifed and as directed by Engineer-in-charge.
M&L for rectification of leakage from GI 25 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 25 mm bore medium grade pipe for stopping the leakage by making welding/replacemnt of necessary fittings of the same after drain out water from pipeline including insertion of pipe length upto 01 RM complete all as specifed and as directed by Engineer-in-charge.
M&L for rectification of leakage from 80 mm size bore CI pipe line by cutting and removing old lengh of pipe, supply & fix new cast iron pipe of size 80 mm bore pipe for stopping the leakage by making welding/replacemnt of necessary fittings of the same after drain out water from pipeline including insertion of pipe length upto 01 RM complete all as specifed and as directed by Engineer-in-charge.
M&L for rectification of leakage from 100 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new cast iron pipe 100 mm bore pipe for stopping the leakage by making welding/replacemnt of necessary fittings of the same after drain out water from pipeline including insertion of pipe length upto 01 RM complete all as specifed and as directed by Engineer-in-charge.
M&L for rectification of leakage from 150 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new cast iron pipe 150 mm bore pipe for stopping the leakage by making welding/replacemnt of necessary fittings of the same after drain out water from pipeline including insertion of pipe length upto 01 RM complete all as specifed and as directed by Engineer-in-charge.
Taking up or down from trenches/wall/floor/ceiling, steel tubing and connections including for refixing or for schedule of credit complete all as directed of the following size:-(Note:- Earth work will be measured & paid separately.)
50mm bore
40mm bore
25mm bore
20mm bore
M&L of GI tubing medium grade incluidng GI fittings like sockets, elbow, bends, tees , union, short pieces etc. laid in trench complete all as specified and as directed of size.
50 mm bore
40 mm bore
25 mm bore
20 mm bore
S&F in replacement of MCCB 3 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KAsuitable for fixing in in LT panels as per sample, complete all as specified and as directed by Engr-in-charge.
S&F in replacement of MCCB 3 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA suitable for fixing in in LT panels as per sample, complete all as specified and as directed by Engr-in-charge.
S&F in replacement of MCCB 3 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA suitable for fixing in in LT panels as per sample, complete all as specified and as directed by Engr-in-charge.
M&L for repairing of unserviceable conventional type fire alarm control panel system complete by replacement of burnt control wiring , and unserviceable electrical components and make the system serviceable and make necessary testings after completion of repair work complete all as specified and as directed.
M&L for in replacement of unserviceable Mike in fire alarm system . .
M&L for in replacement of unserviceable PA equipment mother board .
M&L for in replacement of unserviceable MCP as specified and directed .
Supply and fix Digital water level Indicator Device type -DDS -6 , digit display 150 mm size, direct display in digits , 230 volts Ac ,50 Hz suitable for upto 40 Mtrs , Over head tank , Alarm for upper and Lower Level Pre -adjustable , Temperature Range -5 degree C to 50 degree C , Humidity upto 95% RH , Reset push switch for silent the Alarm with ON/OFF Oper ation system including 4 core 0.5 sqmm copper cable all as directed by Engineer -in- charge . Note:- (i) As contract is maintenance nature the site can be handed over in pieces as per site availability from users.(ii) Contractor/ contractor rep shall take complaint from MES complaint cell on every day and these complaints shall be rectified with in 48 Hrs. As water supply/fire fighting is of vital nature, If any complaint/ work is not completed with in 48 Hrs that can be get executed from any other agency and cost of the same will be deducted from contractor's dues.
Cleaning of Bar screen chamber of size 1.7 x 2 x 2.5 mtr and grit chamber of size 1.7 x 2 x 2.5 mtr by operating suction machine of capacity 5000 ltr with air blowing compressor including required manpower to operate the same and handling all the cleaning process for dissolving slit with sewage water and taking out mixed slit, mud and sludge after scraping from surfaces and making necessary arrangement required for cleaning including replacement of broken/ blockage air blowing network complete all as specified and as directed by Engineer-in-Charge. Note :- 1. Cleaning shall be done at a span of every 3 months starting from the date of commencement. 2. Each time cleaning shall be counted as one Job. 3. Sludge/Mud should be dispose away from the station.
Cleaning of main sawage collection sump (of sizes 8.3 x 8.6 x 3 mtr) by operating suction machine of capacity 5000 ltr with air blowing compressor including required manpower to operate the same and handling all the cleaning process for dissolving slit with sewage water and taking out mixed slit and sludge after scraping from surfaces and making necessary arrangement required for cleaning including replacement of broken/ blockage air blowing network all as specified and as directed by Engineer-in-Charge. Note :- 1. Cleaning shall be done at a span of every 3 months starting from the date of commencement. 2. Each time cleaning shall be counted as one Job. 3. Sludge/Mud should be dispose away from the station.
Cleaning of aeration tank/treated water tank (of size 10.7 x 8.8 x 6.0 mtr) by operating suction machine of capacity 5000 ltr with air blowing compressor including required manpower to operate the same and handling all the cleaning process for dissolving slit with sewage water and taking out mixed slit mud and sludge after scraping from surfaces and making necessary arrangement required for cleaning including replacement of broken/ blockage air blowing network all as specified and as directed by Engineer-in-Charge. Note :- 1. Cleaning shall be done at a span of every 3 months starting from the date of commencement. 2. Each time cleaning shall be counted as one Job. 3. Sludge/Mud should be dispose away from the station. 4. Injection grouting with waterproofing chemicals in leakages surfaces above. 5. Exposed external surfaces to be finished with two coats of cement paints , where as decided by Engr-in-charge. 6. Internal surfaces to be coated with two coat of epoxy paint.
Cleaning of MBBR tank (of size 10.7 x 7.2 x 6.8 mtr) for cleaning of above ground sewage collection tanks by operating suction machine of capacity 5000 ltr with air blowing compressor including required manpower to operate the same and handling all the cleaning process for dissolving slit with sewage water and taking out mixed slit mud and sludge after scraping from surfaces and making necessary arrangement required for cleaning including replacement of broken/ blockage air blowing network all as specified and as directed by Engineer-in-Charge. Note :- 1. Cleaning shall be done at a span of every 3 months starting from the date of commencement. 2. Each time cleaning shall be counted as one Job. 3. Sludge/Mud should be dispose away from the station. 4. Injection grouting with waterproofing chemicals in leakages surfaces above. 5. Exposed external surfaces to be finished with two coats of cement paints , where as decided by Engr-in-charge.
Cleaning of tube settler tank ( of size 6.0x3.0x3.0 mtr) by operating suction machine of capacity 5000 ltr with air blowing compressor including required manpower to operate the same and handling all the cleaning process for dissolving slit with sewage water and taking out mixed slit, mud and sludge after scraping from surfaces and making necessary arrangement required for cleaning including replacement of broken/ blockage air blowing network all as specified and as directed by Engineer-in-Charge. Note :- 1. Cleaning shall be done at a span of every 3 months starting from the date of commencement. 2. Each time cleaning shall be counted as one Job. 3. Sludge/Mud should be dispose away from the station. 4. Injection grouting with waterproofing chemicals in leakages surfaces above. 5. Exposed external surfaces to be finished with two coats of cement paints , where as decided by Engr-in-charge.
Cleaning of Pre filtration tank( of size 6.0x3.0xx3.0 mtr) by operating suction machine of capacity 5000 ltr with air blowing compressor including required manpower to operate the same and handling all the cleaning process for dissolving slit with sewage water and taking out mixed slit, mud and sludge after scraping from surfaces and making necessary arrangement required for cleaning including replacement of broken/ blockage air blowing network all as specified and as directed by Engineer-in-Charge. Note :- 1. Cleaning shall be done at a span of every 3 months starting from the date of commencement. 2. Each time cleaning shall be counted as one Job. 3. Sludge/Mud should be dispose away from the station. 4. Injection grouting with waterproofing chemicals in leakages surfaces above. 5. Exposed external surfaces to be finished with two coats of cement paints , where as decided by Engr-in-charge.
M&L for taking out old quartz silica sand and pebbles from dual media filter tank of size 1.5 mtr dia and 1.8 height and shape and filling the new quartz silica sand in layers of different grades ( 4-8, 8-16, 16-32, 32-64) as per matching to existing size and shape as per requirement complete all as specified and as directed by Engineer-in-charge. Note : Washing and cleaning of pebbles and refilling the same is also included in this job.
M&L for taking out old activated carbon media and Pebbles from activated carbon filter tank of size 1.5 mtr dia and 1.8 height and filling the new actvated carbon media as per matching to existing size and shape as per requirement complete all as specified and as directed by Engineer-in-charge. Note : Washing and cleaning of pebbles and refilling the same is also included in this job.
M&L for taking out old UPVC filter biomedia from MBBR tank of size 10.7 x 7.20 x 6.8 mtr and filling the new filter media complete all as specified and as directed by Engineer-in-charge.
Disconnect the cable connection from centrifugal sewage pump set of 03 HP capacity sludge pump from foundation with the help of special tools, opening the motor and rewinding with super enameled copper wire as per existing gauge including varnishing, making it serviceable by replacement of all unserviceable spares and make motor serviceable complete all as specified and as directed by Engineer-in-charge.
Disconnect the cable connection from centrifugal pump set of capacity 5.0/7.5 HP from treated water system and repair the same by rewinding with super enameled copper wire as per existing gauge including varnishing, making it serviceable by replacement of all unserviceable spares like pump impeller- 01 No, inner and outer rotor - 01 set, complete gasket - 01 Set and bushing-02 Nos and testing the same after installation including necessary cable and pipelines connections complete all as specified and as directed by Engineer-in-charge. Note :- (i) Any parts require for replacement shall be measured and paid seperately. (ii) Rate for item required other than below mentioned items shall be included in rate quoted by the contractor for this item.
S&F in replacement of 'O' ring complete all as specifed and as directed by Engineer-in-charge.
S&F in replacement of mechanical seal complete all as specifed and as directed by Engineer-in-charge.
S&F in replacement of water seal complete all as specifed and as directed by Engineer-in-charge.
S&F in replacement of ball bearing for centrifugal pump set for 5.0/7.5 HP as per existing make and size complete all as specifed and as directed by Engineer-in-charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers , of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed by Engr-in-Charge.
M&L for taking out burnt unserviceable sewage submersible pump set of capacity 7.5/10.0 HP from main sewage collection sump and repair of same by rewinding with super enameled copper wire as per existing gauge including varnishing, making it serviceable by replacement of all unserviceable spares like pump impeller- 01 No, inner and outer rotor - 01 set, complete gasket - 01 Set and bushing-02 Nos and testing the same after installation including necessary cable and pipelines connections complete all as specified and as directed by Engineer-in-charge. Note :- (i) Any parts require for replacement shall be measured and paid seperately. (ii) Rate for item required other than below mentioned items shall be included in rate quoted by the contractor for this item.
S&F in replacement of 'O' ring complete all as specifed and as directed by Engineer-in-charge.
S&F in replacement of mechanical seal complete all as specifed and as directed by Engineer-in-charge.
S&F in replacement of water seal complete all as specifed and as directed by Engineer-in-charge.
S&F in replacement of ball bearing for sewage submersible pump set for 7.5/10.0 HP as per existing make and size complete all as specifed and as directed by Engineer-in-charge. Make : SKF/NBC/TATA.
M&L for repairing and servicing of fertilizer machine including re-winding of 15 HP capacity centrifugal pump motor with super enameled copper wire as per existing gauge including varnishing, and replacement of all unserviceable spares like bearing-02 Nos, gasket-01 Set and power supply connector plate -01 No etc making it serviceable and testing the same complete all as specified and as directed by Engineer-in-charge
Supply & Fix in replacement of 3/8" PVC flexible suction/ delivery pipe as per existing pipe for chlorination system complete all as specified and as directed by Engineer-in-charge
M&L for repair to unserviceable dosing pump for chlorination system and repair of same , including replacement of all unserviceable spares like pump tube - 01 No, pump head -010 No and injection check valve -01 No and making it serviceable by replacement of unsv parts and testing the same complete all as specified and as directed by Engineer-in-charge.
Supply & Fix in replacement of pre air filter for 25 HP Air compressor as per matching to existing type complete all as specified and as directed by Engineer-in-charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 25 x4 mm as earth strip by means of bolts, nuts, check nuts and washers , of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 50 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed by Engr-in-Charge.
M&L for replacement of 360 grade compressor oil suitable for air compressor.
Supply & Fix in replacement of motor belt B93 series ser No B2362 for driving the air compressor complete all as specified and as directed by Engineer-in- charge.
Supply & Fix in replacement of pulley for driving the air compressor as per existing type complete all as specified and as directed by Engineer-in- charge.
Taking out of old unserviceable cascading type areator from its original location by carefully taking down the entire steel structure by using gas cutters and preparing the cut surface to re fabrication purpose , scrubbing and cleaning complete all as specified and as directed.
Supply and Fix in replacement of SS stud nuts and bolts as per matching to existing and as directed by engr in charge
Taking shut down from main LT panel and making repair to any type of LT electric starter panel including welding of hanging/broken door, spary painting after scrapping old surfaces with synthetic enamel paint, dismantling of old wiring discipline inside the panel re-installation of wiring discipline according to the existing one complete with all relevant connection with cable glands, thimble and proper termination all as specifed and as directed by Engineer-in-charge.
Supply and fix in replacement of PVC junction box of size 140 x 140 x 95 mm having connector for LT cable as per matching to existing complete all as specified and as directed by engr in charge.
Testing of STP before treatment to analysis the following parameter as per IS 10500:2000 through Govt. approved agency:- a) Physicochemical parameters of water / eflluent sample b) Oil and grease, mg/l max. c) Total residual chlorine, mg/l max. d) Biochemical oxygen demand mg/l max. e) Chemical oxygen demand mg/l max. f) Suspended solids mg/l max. Note:- Water sample for testing shall be arranged by the contractor. 2. Testing shall be done at a span of every 3 months starting from the date of commencement.
Testing of STP after treatment to analysis the following parameter as per IS 10500:2000 through Govt. approved agency:- a) Physicochemical parameters of water / eflluent sample b) Oil and grease, mg/l max. c) Total residual chlorine, mg/l max. d) Biochemical oxygen demand mg/l max. e) Chemical oxygen demand mg/l max. f) Suspended solids mg/l max. Note:- Water sample for testing shall be arranged by the contractor. 2. Testing shall be done at a span of every 3 months starting from the date of commencement.
Supply & Fix in replacement of butterfly valve of size 40mm as per matching to existing shape.
Supply & Fix in replacement of butterfly valve of size 80mm.
Supply & Fix in replacement of butterfly valve of size 100mm.
Supply & Fix in replacement of butterfly valve of size 150mm .
Supply & Fix in replacement of MCB SP 6 amps 'C" series.
Supply & Fix in replacement of MCB DP 10 amps 'C" series.
Supply & Fix in replacement of MCB TP 16 to 32 amps 'C" series as per site requirement.
Supply & Fix in replacement of on off push button as per sample.
S&F in replacement of MCCB 3 pole 63A, Fixed Overload & fixed short circuit setting, breaking capacity 16KA fixed in in LT panels, complete all as specified and as directed by Engr-in-charge.
S&F in replacement of MCCB 3 pole 100A, Fixed Overload & fixed short circuit setting, breaking capacity 16KA fixed in in LT panels, complete all as specified and as directed by Engr-in-charge.
Material and labour for supply and laying of square or rectangular air grids for aeration in Aeration/ Equilization tank, MBBR Tank I and II to ensure fine bubbles dispersion with PVC/SS pipes of size 50mm dia, inter connected with necessary flange and difussers for pressurised air at every 2 mtr distance along the pipe all as required at site and directed by the Engineer-in-Charge. Note:- (i) As contract is maintenance nature the site can be handed over in pieces as per site availability from users.(ii) Contractor/ contractor rep shall take complaint from MES complaint cell on every day and these complaints shall be rectified with in 48 Hrs. As water supply/sewage system is of vital nature, If any complaint/ work is not completed with in 48 Hrs that can be get executed from any other agency and cost of the same will be deducted from contractor's dues.
Note :- The amount of Rs 107730.00 against Schedule of Credit on Srl Page 157 & 158 shall be deducted from the total amount quoted against Sch 'A'
M/S Anand Enterprises (BID ID -3493988)
M/S PARKASH ENTERPRISES (BID ID -3493883)
BRIJ MOHAN LAL AND CO. (BID ID -3500517)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
BOQ_829106.xls
BOQ • 0.73 MB
TenderDocument-65.pdf
Tender Documents • 1.57 MB
Download all tender documents and submit your bid